Hager EHN010 Daily Time Switch 230V 1-Channel 1-Module
The Hager EHN010 is a compact 1-module daily time switch with a 24-hour programme cycle for automated switching of lighting, heating, ventilation, and general electrical loads in UAE residential, commercial, and industrial distribution boards. Its single DIN rail module width makes it one of the most space-efficient daily timers available, integrating neatly alongside MCBs and contactors in standard DBs.
Key Features
- 24-hour daily programme cycle with 15-minute minimum switching interval
- 1-channel, 1-module design — minimal panel space at just 17.5mm wide
- 230–240V AC supply, DIN rail mounting for standard panel installation
- NO (normally open) contact rated at 3A (cos φ 0.6)
- Supports loads up to 1000W incandescent, 900W halogen, 300W LED
- Screw terminal connection accepting 1–6mm² flexible and rigid conductors
- 50,000 operating cycles electrical durability
- REACh-SVHC free and RoHS compliant
- Genuine Hager product — trusted European quality
Technical Specifications
| Specification |
Details |
| Brand |
Hager |
| Model |
EHN010 |
| Type |
Daily time switch (24-hour cycle) |
| Channels |
1 |
| DIN Rail Modules |
1 (17.5mm wide) |
| Rated Voltage |
220–240V AC |
| Frequency |
50Hz |
| Contact Rating |
3A (cos φ 0.6) |
| Switch Mode |
NO (Normally Open) contact |
| Programme Cycle |
24 hours (daily) |
| Shortest Switching Time |
15 minutes |
| Max Load — Incandescent |
1000W |
| Max Load — Halogen (230V) |
900W |
| Max Load — LED |
300W |
| Connection |
Screw terminals, 1–6mm² (flexible & rigid) |
| Mounting |
DIN rail |
| Dimensions (H × W × D) |
90mm × 17.5mm × 60mm |
| Operating Temperature |
-20°C to +50°C |
| Electrical Durability |
50,000 operating cycles (AC1) |
| Power Consumption |
1W |
| RoHS Compliant |
Yes |
| REACh-SVHC Free |
Yes |
Applications
- Automated daily lighting control in residential and commercial buildings
- Heating, ventilation, and air conditioning scheduled switching
- Pump, signage, and display load time control
- Energy management and daily load scheduling in distribution boards
FAQ
-
Can I install this myself?
No — a DIN rail time switch is wired inside a distribution board, typically feeding a contactor for higher-current loads. Installation should go through a licensed electrician.
-
Does this need a contactor for lighting or HVAC circuits?
Yes, if the load exceeds the time switch's own contact rating — pair it with a Hager installation contactor (e.g. the ESC range) so the timer switches the contactor's control coil rather than the load directly.
-
What happens to the programme during a power cut?
The battery backup retains the time and programme settings through short power interruptions, so scheduled switching resumes automatically once power is restored.
-
Can the programme be changed after installation?
Yes — the programme is fully reprogrammable at any time via the front-panel controls, without needing to rewire anything.