ABB F204 RCCB 100A 4-Pole 300mA Type AC — ELCB

Regular price AED 363.00 inc. VAT
In stock
Usually ships within 24 hours
Fast UAE delivery & easy returns

Order before 12 PM for same-day dispatch. Delivered in 1–2 business days across the UAE, free on orders over AED 200 (AED 15 below). Unused items in sealed packaging can be returned within 7 days.

Free UAE delivery over AED 200
100% secure payments
Genuine branded products

Ask an expert!

ABB ELCB/RCCB 100A 4P 300mA F204

ABB Earth Leakage Circuit Breaker (ELCB/RCCB) 4-pole, 100 A, 300 mA residual current rating. Built for durability and reliable protection in UAE electrical installations.

Key Features

  • Four-pole (4P) residual current circuit breaker (RCCB) for earth-leakage protection
  • Rated current: 100 A with 300 mA residual current sensitivity
  • Type AC sensitivity: detects sinusoidal AC residual fault currents
  • Conditional short-circuit rating: 10 kA
  • Complies with IEC 61008
  • DIN-rail mounting for standard distribution boards
  • Brand: ABB
  • Current rating: 100 A
  • Type: ELCB/RCCB, 4P
  • Residual current rating: 300 mA
  • Model: F204
  • Durable construction for long service life

Technical specifications

Specification Value
Brand ABB
Product type ELCB / RCCB
Current rating 100 A
Poles 4P
Residual current rating 300 mA
Model F204

Applications

  • Protection for distribution boards in commercial and residential UAE projects
  • Suitable for 4-pole protection in main and sub-distribution panels
  • Ideal for electrical rooms and control panels requiring reliable earth leakage protection

FAQ

  • What's the difference between an MCB and an RCCB/RCD?
    An MCB protects circuits and wiring against overload and short-circuit current. An RCCB like this one protects against earth leakage by monitoring current imbalance and disconnecting the circuit — the two are complementary and are normally installed together in a distribution board.
  • What does the 300mA sensitivity rating mean?
    300mA RCCBs are sized for fire and equipment protection on larger circuits and sub-mains, not personal shock protection — that requires a 30mA device. A 300mA unit is a common choice as a main incomer or sub-distribution protection device upstream of 30mA final-circuit RCDs.
  • How many poles do I need?
    A 4-pole (4P) RCCB switches all three phases plus neutral together. Use 4P for three-phase supplies or distribution boards where the neutral must also be isolated; 2-pole devices are used for single-phase circuits.
  • Can this be used alongside MCBs in the same board?
    Yes. This RCCB is typically installed upstream of the MCBs it protects, on the same DIN rail, so a leakage fault trips the RCCB while overloads/short circuits are still cleared by the individual MCBs.
  • Can I install this myself?
    No. RCCBs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.

Orders placed before 12 PM (UAE time) are dispatched the same business day and delivered in 1–2 business days across the UAE. Delivery is free on orders over AED 200; below that it costs AED 15. International shipping is charged by weight at checkout, and international orders cannot be returned. Read our Shipping Policy and Refund Policy.