{"product_id":"abb-sh203-c32-32a-3p-mcb-type-c","title":"ABB SH203-C32 MCB 32A 3-Pole 6kA Type C","description":"\u003cdiv\u003e\n\u003ch2\u003eABB Miniature Circuit Breaker 32A 3-Pole Type C SH203-C32\u003c\/h2\u003e\n\u003cp\u003eSystem pro M compact S200 series three-pole MCB with dual trip mechanisms for reliable overload and short-circuit protection. Designed for domestic\/residential installations in defined markets, it features current limiting protection and a space-saving bottom-fixing auxiliary contact design.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree-pole (3P) MCB for multi-phase distribution protection\u003c\/li\u003e\n\u003cli\u003eRated current: 32 A with 6 kA breaking capacity at 230\/400 V AC\u003c\/li\u003e\n\u003cli\u003eType C tripping curve, suited for general electrical loads\u003c\/li\u003e\n\u003cli\u003eDual trip mechanism: delayed thermal (overload) and electromagnetic (short-circuit)\u003c\/li\u003e\n\u003cli\u003eComplies with IEC\/EN 60898-1\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting (TH35-7.5 \/ TH35-15 per IEC 60715)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eThree-pole, 32 A, Type C\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 6 kA\u003c\/li\u003e\n\u003cli\u003eDual trip: delayed thermal for overload and magnetic for short circuit\u003c\/li\u003e\n\u003cli\u003eSystem pro M compact S200 family\u003c\/li\u003e\n\u003cli\u003eBottom fixing auxiliary contact for space-saving installation\u003c\/li\u003e\n\u003cli\u003eStandards: IEC, UL, CSA\u003c\/li\u003e\n\u003cli\u003eMaterial: Durable plastic housing\u003c\/li\u003e\n\u003cli\u003eON-OFF operation mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSH203-C32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping characteristics\u003c\/td\u003e\n\u003ctd\u003eThermal (overload) + Magnetic (short-circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity\u003c\/td\u003e\n\u003ctd\u003e6 kA (Icn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSystem pro M compact S200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eBottom fixing auxiliary contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eDurable plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation\u003c\/td\u003e\n\u003ctd\u003eON-OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDomestic and residential circuits in defined UAE markets\u003c\/li\u003e\n\u003cli\u003eThree-pole protection for multi-wire distribution boards\u003c\/li\u003e\n\u003cli\u003eSmall-scale commercial installations requiring reliable overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 3-pole (3P) breaker switches all three phases on a three-phase circuit without a switched neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797520949347,"sku":"Sh203-C32","price":60.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-mcbs-default-title-abb-three-pole-miniature-circuit-breaker-32a-tp-mcb-6ka-type-c-sh203-c32-2cds213001r0324-31538365333603.jpg?v=1787498180","url":"https:\/\/www.deluxeuae.com\/products\/abb-sh203-c32-32a-3p-mcb-type-c","provider":"Deluxe Electricals","version":"1.0","type":"link"}