{"product_id":"abb-sh201-c10-1-pole-10a-6ka-type-c-mcb","title":"ABB 10A 6kA Single Pole MCB, SH201-C10 2CDS211001R0104","description":"\u003ch2\u003eABB SH201-C10 1-Pole 10A 6kA Type C MCB\u003c\/h2\u003e\n\u003cp\u003eThe ABB SH201-C10 is a 1-pole 10A Type C miniature circuit breaker with 6kA breaking capacity from the ABB SH200 series. Current-limiting and current-compliant with IEC\/EN 60898-1, it is designed for protection of single-phase circuits in residential and light commercial distribution boards, making it well suited to lighting and power circuit protection in UAE building installations.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1-pole 10A Type C MCB for single-phase lighting and power circuit protection\u003c\/li\u003e\n  \u003cli\u003e6kA breaking capacity for standard UAE residential and commercial installation fault levels\u003c\/li\u003e\n  \u003cli\u003eDual tripping mechanism — delayed thermal for overload and electromechanic for short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eCompact single-module DIN rail mounting compliant with TH35 rail standards for distribution board installation\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB SH200 series quality — consistent performance and reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSH201-C10\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail (TH35-15 \/ TH35-7.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (IP40 with cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eElectrical\/Mechanical Endurance\u003c\/td\u003e\n\u003ctd\u003e20,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 60898-1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.102 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e17.5 mm (1 modular space)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSingle-phase lighting circuit protection in residential DBs\u003c\/li\u003e\n  \u003cli\u003ePower and socket circuit protection in commercial distribution boards\u003c\/li\u003e\n  \u003cli\u003eGeneral building services circuit protection in UAE installations\u003c\/li\u003e\n  \u003cli\u003eConsumer unit and distribution board MCB replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44344540561507,"sku":"SH201-C10","price":14.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000150962_400x400_49809951-ee9e-4f8d-8c2c-8c7f2588b861.jpg?v=1787498346","url":"https:\/\/www.deluxeuae.com\/products\/abb-sh201-c10-1-pole-10a-6ka-type-c-mcb","provider":"Deluxe Electricals","version":"1.0","type":"link"}