{"product_id":"abb-ot1600e03p-3-pole-1600a-switch-disconnector","title":"ABB OT1600E03P Switch-Disconnector 1SCA022860R6580","description":"\u003ch2\u003eABB OT1600E03P 3-Pole 1600A Switch Disconnector\u003c\/h2\u003e\n\u003cp\u003eThe OT1600E03P is a heavy-duty 3-pole switch disconnector rated at 1600A, complete with a black IP65-rated handle and shaft plus terminal bolt kit for straightforward installation. Built for main isolation duty in high-current distribution systems, it is well suited to large commercial and industrial switchboards, substations, and main incomer applications across the UAE.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3-pole switch disconnector rated 1600A (AC-21A\/AC-22A) with 1250A rating for AC-23A motor-type loads\u003c\/li\u003e\n\u003cli\u003eBlack IP65-rated handle and shaft included, along with terminal bolt kit for fast, complete installation\u003c\/li\u003e\n\u003cli\u003e110kA rated short-circuit making capacity (Icm) and 50kA short-time withstand current for demanding fault conditions\u003c\/li\u003e\n\u003cli\u003e1000V rated insulation voltage and 12kV rated impulse withstand voltage for high dielectric strength\u003c\/li\u003e\n\u003cli\u003eGenuine ABB quality — manufactured in Finland to IEC 60947-3 standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eOT1600E03P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Current (Ie) AC-21A\/AC-22A\u003c\/td\u003e\n\u003ctd\u003e1600A (380–690V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Current (Ie) AC-23A\u003c\/td\u003e\n\u003ctd\u003e1250A (380–690V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e1000V (main circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e12kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Short-Circuit Making Capacity (Icm)\u003c\/td\u003e\n\u003ctd\u003e110kA at 690V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Short-Time Withstand Current (Icw)\u003c\/td\u003e\n\u003ctd\u003e50kA for 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current\u003c\/td\u003e\n\u003ctd\u003e80kA (1250A fuse, 415V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eFront IP20 (handle IP65)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eBase mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Mode\u003c\/td\u003e\n\u003ctd\u003eFront operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eLug terminals, 50mm width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening Torque\u003c\/td\u003e\n\u003ctd\u003e50–75 N·m (acc. IEC 60947-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Durability\u003c\/td\u003e\n\u003ctd\u003e6,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e17.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e334.5 x 372 x 167 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNote\u003c\/td\u003e\n\u003ctd\u003eHandle, shaft, and terminal bolt kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain incomer isolation in large low voltage switchboards and substations\u003c\/li\u003e\n\u003cli\u003eHigh-current load isolation for major feeders in industrial facilities\u003c\/li\u003e\n\u003cli\u003eMain disconnect switching in generator and transformer-fed distribution systems\u003c\/li\u003e\n\u003cli\u003eSafe isolation point for maintenance on high-capacity electrical infrastructure in UAE facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this an MCB or an isolator?\u003c\/strong\u003e\u003cbr\u003eIt's an isolator (switch-disconnector), not an MCB. It has no overload or short-circuit protection — it only provides a manual on\/off disconnect, and should be paired with separate MCBs or RCCBs for circuit protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does 3-pole mean for this isolator?\u003c\/strong\u003e\u003cbr\u003e3-pole means it switches all three phases on a three-phase supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere should this isolator be installed?\u003c\/strong\u003e\u003cbr\u003eTypically as the main incoming switch or a local isolation point ahead of the MCBs\/RCCBs in a distribution board, so the whole board (or a section of it) can be isolated for maintenance without needing to trip individual breakers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is trade-only distribution board equipment and must be installed and connected by a licensed electrician in accordance with local wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this isolator be used to switch a live circuit under load?\u003c\/strong\u003e\u003cbr\u003eIsolators rated for on-load switching can do this within their utilisation category, but check the specific AC rating in the Technical Specifications table — an isolator is not a protective device and should not substitute for a circuit breaker.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44344137482339,"sku":"1SCA022860R6580","price":4537.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9IBA039694_400x400_1c13d36b-f0bd-4f7b-be02-b509a8eb5550.jpg?v=1787498339","url":"https:\/\/www.deluxeuae.com\/products\/abb-ot1600e03p-3-pole-1600a-switch-disconnector","provider":"Deluxe Electricals","version":"1.0","type":"link"}