{"product_id":"abb-mccb-xt1c-160-tmd-80-800-3-pole","title":"ABB MCCB XT1C 160 TMD 80-800 3-Pole","description":"\u003ch2\u003eABB MCCB XT1C 160 TMD 80-800 3-Pole\u003c\/h2\u003e\n\u003cp\u003eThe ABB MCCB XT1C 160 TMD 80-800 3P is a 3-pole MCCB from the Tmax XT1 series with an 80–800A adjustable TMD trip unit and 25kA breaking capacity at 415V. It provides reliable overcurrent and short-circuit protection for sub-main feeders and large power circuits in UAE commercial and industrial installations.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3-pole MCCB with adjustable TMD trip unit 80–800A\u003c\/li\u003e\n\u003cli\u003e25kA breaking capacity at 415V AC\u003c\/li\u003e\n\u003cli\u003eFixed front mounting for panel and switchgear installation\u003c\/li\u003e\n\u003cli\u003eCompact Tmax XT1 design\u003c\/li\u003e\n\u003cli\u003eGenuine ABB Tmax XT quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 99.915%; height: 156.818px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003cth style=\"width: 37.1141%; height: 19.6023px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"width: 60.3175%; height: 19.6023px;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 37.1141%; height: 19.6023px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 60.3175%; height: 19.6023px;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 37.1141%; height: 19.6023px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 60.3175%; height: 19.6023px;\"\u003eXT1C 160 TMD 80-800 3p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 37.1141%; height: 19.6023px;\"\u003eArticle Number\u003c\/td\u003e\n\u003ctd style=\"width: 60.3175%; height: 19.6023px;\"\u003e1SDA067396R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 37.1141%; height: 19.6023px;\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"width: 60.3175%; height: 19.6023px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 37.1141%; height: 19.6023px;\"\u003eTrip Unit\u003c\/td\u003e\n\u003ctd style=\"width: 60.3175%; height: 19.6023px;\"\u003eTMD 80–800A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 37.1141%; height: 19.6023px;\"\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd style=\"width: 60.3175%; height: 19.6023px;\"\u003e25kA @ 415V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 37.1141%; height: 19.6023px;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"width: 60.3175%; height: 19.6023px;\"\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree-phase sub-main feeder protection\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial distribution board incoming\u003c\/li\u003e\n\u003cli\u003eMCC and switchgear circuit protection\u003c\/li\u003e\n\u003cli\u003eHigh-current circuit protection in large buildings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole device, sized for the corresponding single or three-phase supply arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140749488227,"sku":"1SDA067396R1","price":250.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9IBA248846_400x400_b38b808f-b32a-4484-8bd2-968f0e4fd772.png?v=1786966375","url":"https:\/\/www.deluxeuae.com\/products\/abb-mccb-xt1c-160-tmd-80-800-3-pole","provider":"Deluxe Electricals","version":"1.0","type":"link"}