{"product_id":"abb-mcb-s202-c63-2-pole-63a-6ka-type-c","title":"ABB MCB S202-C63 2-Pole 63A 6kA Type C","description":"\u003ch2\u003eABB MCB S202-C63 2-Pole 63A 6kA Type C\u003c\/h2\u003e\u003cp\u003eThe ABB S202-C63 is a 2-pole 63A Type C MCB with 6kA breaking capacity for protection of high-current single-phase circuits in UAE commercial distribution boards. Its 63A rating makes it suitable for large power circuits, sub-main protection, and DB incoming switches where double-pole switching is required.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2-pole 63A Type C MCB for high-current single-phase circuit protection\u003c\/li\u003e\n\u003cli\u003e6kA breaking capacity for standard UAE commercial installations\u003c\/li\u003e\n\u003cli\u003eType C curve suitable for motor and general power loads\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine ABB S200 series quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS202-C63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e2CDS252001R0634\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230\/400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-current single-phase power circuit protection\u003c\/li\u003e\n\u003cli\u003eDB sub-main and incoming circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial distribution board circuits\u003c\/li\u003e\n\u003cli\u003eAir conditioning and large appliance circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (2P) breaker switches both live and neutral together, giving full isolation on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140749226083,"sku":"2CDS252001R0634","price":75.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000184250_400x400_d0eed1d0-0b55-4fad-9b80-7878fb61bc25.jpg?v=1786966299","url":"https:\/\/www.deluxeuae.com\/products\/abb-mcb-s202-c63-2-pole-63a-6ka-type-c","provider":"Deluxe Electricals","version":"1.0","type":"link"}