{"product_id":"abb-kse380tpn-3-pole-75a-enclosed-isolator","title":"Abb KSE380TPN Enclosed Switch Disconnector","description":"\u003ch2\u003eABB KSE380TPN Enclosed Switch Disconnector\u003c\/h2\u003e\n\u003cp\u003eThe KSE380TPN is a 3-pole enclosed switch disconnector rated at 75A, housed in a rigid die-cast aluminium (silumin) enclosure with IP65 protection and polyester coating for corrosion resistance. Built for harsh environments, it offers reliable local isolation with a padlockable round handle and interlocked cover, well suited to outdoor and industrial installations across the UAE.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3-pole switch disconnector rated 75A (AC-23A) with fixed neutral and PE terminal included\u003c\/li\u003e\n  \u003cli\u003eIP65-rated die-cast aluminium enclosure with polyester coating, well protected from corrosion in harsh environments\u003c\/li\u003e\n  \u003cli\u003ePadlockable round handle with two padlocks, interlocked cover, and option to padlock in the On position\u003c\/li\u003e\n  \u003cli\u003eGrommet-type cable glands included for IP54 sealing, with EMC compatibility when used with EMC cable glands\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB quality — impact-resistant housing rated IK08\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKSE380TPN\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Current (Ie) AC-23A\u003c\/td\u003e\n\u003ctd\u003e75A (380–415V)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e750V (main circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e750V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Power AC-23A (400V)\u003c\/td\u003e\n\u003ctd\u003e37kW\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current\u003c\/td\u003e\n\u003ctd\u003e13kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Short-Circuit Making Capacity (Icm)\u003c\/td\u003e\n\u003ctd\u003e2.1kA at 690V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Short-Time Withstand Current (Icw)\u003c\/td\u003e\n\u003ctd\u003e1.5kA for 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP65 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eImpact Resistance\u003c\/td\u003e\n\u003ctd\u003eIK08\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eAluminium (silumin), polyester coated\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHandle Type\u003c\/td\u003e\n\u003ctd\u003eRound, padlockable, black\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNeutral Type\u003c\/td\u003e\n\u003ctd\u003eFixed neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCable Cross-Section\u003c\/td\u003e\n\u003ctd\u003e1.5 – 35 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCable Entry Position\u003c\/td\u003e\n\u003ctd\u003eTop\/Bottom, 2xM40 per side\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTightening Torque\u003c\/td\u003e\n\u003ctd\u003e2 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-1, IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e160 x 230 x 118 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNote\u003c\/td\u003e\n\u003ctd\u003eProduct nearing end-of-life; ABB replacement model is KSE380GTPN\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLocal isolation for HVAC units, pumps, and outdoor machinery in commercial and industrial sites\u003c\/li\u003e\n  \u003cli\u003eMain isolation switch for external distribution boards exposed to UAE outdoor conditions\u003c\/li\u003e\n  \u003cli\u003eSafe isolation point for maintenance on rooftop and plant room equipment\u003c\/li\u003e\n  \u003cli\u003eFeeder isolation in FM-managed facilities requiring IP65-rated, corrosion-resistant enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this an MCB or an isolator?\u003c\/strong\u003e\u003cbr\u003eIt's an isolator (switch-disconnector), not an MCB. It has no overload or short-circuit protection — it only provides a manual on\/off disconnect, and should be paired with separate MCBs or RCCBs for circuit protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere should this isolator be installed?\u003c\/strong\u003e\u003cbr\u003eTypically as the main incoming switch or a local isolation point ahead of the MCBs\/RCCBs in a distribution board, so the whole board (or a section of it) can be isolated for maintenance without needing to trip individual breakers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is trade-only distribution board equipment and must be installed and connected by a licensed electrician in accordance with local wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this isolator be used to switch a live circuit under load?\u003c\/strong\u003e\u003cbr\u003eIsolators rated for on-load switching can do this within their utilisation category, but check the specific AC rating in the Technical Specifications table — an isolator is not a protective device and should not substitute for a circuit breaker.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44344144363619,"sku":"KSE380TPN","price":553.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000324069_400x400_d7e24eb0-51e6-48c0-930a-420e295f8fce.png?v=1787498869","url":"https:\/\/www.deluxeuae.com\/products\/abb-kse380tpn-3-pole-75a-enclosed-isolator","provider":"Deluxe Electricals","version":"1.0","type":"link"}