{"product_id":"abb-kse340tpn-3-pole-25a-enclosed-isolator","title":"ABB KSE340TPN Switch Disconnector 40A 3 Pole IP65","description":"\u003ch2\u003eABB KSE340TPN Enclosed Switch Disconnector\u003c\/h2\u003e\n\u003cp\u003eThe KSE340TPN is a 3-pole enclosed switch disconnector rated at 25A, housed in a rugged aluminium enclosure with IP65 protection. Built for both indoor and outdoor use, it offers reliable local isolation for machinery, feeders, and distribution circuits, with UV-protected paintwork and weatherproof sealing well suited to the dust and heat conditions typical of UAE outdoor installations.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3-pole switch disconnector rated 25A (AC-23A) with fixed neutral and PE terminal for 5-wire system installations\u003c\/li\u003e\n\u003cli\u003eIP65-rated aluminium enclosure, protected against low-pressure water jets, suitable for outdoor and indoor mounting\u003c\/li\u003e\n\u003cli\u003ePadlockable, side-operated handle with interlocked cover for safe isolation during maintenance\u003c\/li\u003e\n\u003cli\u003eThreaded cable entries for 2 parallel cables from top and bottom, with membrane grommets included for IP54 sealing\u003c\/li\u003e\n\u003cli\u003eGenuine ABB quality — impact-resistant housing rated IK09\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKSE340TPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Current (Ie) AC-23A\u003c\/td\u003e\n\u003ctd\u003e25A (380–415V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e690V (main circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e690V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Power AC-23A (400V)\u003c\/td\u003e\n\u003ctd\u003e11kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP65 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpact Resistance\u003c\/td\u003e\n\u003ctd\u003eIK09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eAluminium (silumin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHandle Type\u003c\/td\u003e\n\u003ctd\u003eSide-operated, padlockable, grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeutral Type\u003c\/td\u003e\n\u003ctd\u003eFixed neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Cross-Section\u003c\/td\u003e\n\u003ctd\u003e0.75 – 10 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Entry Position\u003c\/td\u003e\n\u003ctd\u003eTop\/Bottom, 2xM32 per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening Torque\u003c\/td\u003e\n\u003ctd\u003e1.2 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-1, IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e138 x 168 x 68 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLocal isolation for HVAC units, pumps, and outdoor machinery in commercial and industrial sites\u003c\/li\u003e\n\u003cli\u003eMain isolation switch for external distribution boards exposed to UAE outdoor conditions\u003c\/li\u003e\n\u003cli\u003eSafe isolation point for maintenance on rooftop and plant room equipment\u003c\/li\u003e\n\u003cli\u003eFeeder isolation in FM-managed facilities requiring IP65-rated enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this an MCB or an isolator?\u003c\/strong\u003e\u003cbr\u003eIt's an isolator (switch-disconnector), not an MCB. It has no overload or short-circuit protection — it only provides a manual on\/off disconnect, and should be paired with separate MCBs or RCCBs for circuit protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does 3-pole mean for this isolator?\u003c\/strong\u003e\u003cbr\u003e3-pole means it switches all three phases on a three-phase supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere should this isolator be installed?\u003c\/strong\u003e\u003cbr\u003eTypically as the main incoming switch or a local isolation point ahead of the MCBs\/RCCBs in a distribution board, so the whole board (or a section of it) can be isolated for maintenance without needing to trip individual breakers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is trade-only distribution board equipment and must be installed and connected by a licensed electrician in accordance with local wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this isolator be used to switch a live circuit under load?\u003c\/strong\u003e\u003cbr\u003eIsolators rated for on-load switching can do this within their utilisation category, but check the specific AC rating in the Technical Specifications table — an isolator is not a protective device and should not substitute for a circuit breaker.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44344114872419,"sku":"KSE340TPN-SFX","price":150.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000380142_400x400_81eeca32-2bce-4d21-8f97-76a7787cccaa.png?v=1787498867","url":"https:\/\/www.deluxeuae.com\/products\/abb-kse340tpn-3-pole-25a-enclosed-isolator","provider":"Deluxe Electricals","version":"1.0","type":"link"}