{"title":"RCBOs","description":"\u003cp\u003eShop RCBOs for UAE distribution boards — ABB DSE201 M single-pole-plus-neutral devices from 10A to 32A. An RCBO puts the overload and short-circuit protection of an MCB and the earth-leakage protection of an RCD into one module, so a single circuit gets both.\u003c\/p\u003e\u003ch2\u003eWhy choose an RCBO over a shared RCCB?\u003c\/h2\u003e\u003cp\u003eWhere one RCCB covers a whole bank of circuits, an earth fault anywhere on that bank takes out every circuit behind it — lights, sockets, fridge and all. Give each circuit its own RCBO and the fault disconnects only the circuit that caused it. That matters in villas with outdoor sockets, water features and pool equipment, and on any board feeding a tenanted or critical load.\u003c\/p\u003e\u003ch2\u003e30mA or 100mA?\u003c\/h2\u003e\u003cp\u003eThe milliamp figure is the earth-leakage current at which the device disconnects. 30mA is the sensitivity associated with protecting people, and it is normally what is wanted on socket, bathroom and outdoor circuits. 100mA is a coarser setting, used where the concern is fire protection or where sensitive equipment causes nuisance tripping at 30mA. Both are stocked across the range.\u003c\/p\u003e\u003ch2\u003eWhat do the ampere figure and the C mean?\u003c\/h2\u003e\u003cp\u003eThe ampere rating — 10, 16, 20 or 32 — follows the cable of the circuit, not the appliance plugged into it. The C is the trip curve, tolerant of the brief inrush drawn by motors and lighting banks.\u003c\/p\u003e\u003cp\u003eCheck the device suits your board's busbar arrangement, and have a licensed electrician confirm the selection against the DB schedule.\u003c\/p\u003e","products":[{"product_id":"abb-rcbo-dse201-m-c10-10a-30ma-1p-n","title":"ABB RCBO DSE201 M C10 10A 30mA 1P+N","description":"\u003ch2\u003eABB RCBO DSE201 M C10 10A 30mA 1P+N\u003c\/h2\u003e\u003cp\u003eThe ABB DSE201 M C10 AC30 is a 1P+N RCBO (Residual Current Breaker with Overcurrent) rated 10A with 30mA earth fault sensitivity. Combining MCB and ELCB protection in a single module, it provides both overcurrent and earth leakage protection for individual circuits in UAE residential and commercial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1P+N RCBO combining MCB and ELCB protection in one module\u003c\/li\u003e\n\u003cli\u003e10A circuit rating with Type C tripping characteristic\u003c\/li\u003e\n\u003cli\u003e30mA high-sensitivity earth fault protection\u003c\/li\u003e\n\u003cli\u003eSpace-saving 2-module width for DB installation\u003c\/li\u003e\n\u003cli\u003eGenuine ABB DSE201 quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDSE201 M C10 AC30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e2CSR275053R1104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIndividual circuit protection in residential DBs\u003c\/li\u003e\n\u003cli\u003eSocket and lighting circuit RCBO protection\u003c\/li\u003e\n\u003cli\u003eCommercial building individual circuit protection\u003c\/li\u003e\n\u003cli\u003eWet area and outdoor circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is an RCBO, and how is it different from an MCB or RCCB?\u003c\/strong\u003e\u003cbr\u003eAn RCBO (Residual Current Breaker with Overcurrent protection) combines an MCB and an RCCB in one device — it protects a single circuit against both overload\/short-circuit and earth leakage, instead of needing separate devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e30mA RCBOs are sized for personnel\/shock protection on final circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy use an RCBO instead of a shared RCCB for multiple circuits?\u003c\/strong\u003e\u003cbr\u003eAn RCBO protects one circuit only, so a leakage fault on that circuit trips just that RCBO rather than a shared RCCB covering several circuits — this avoids losing power to unaffected circuits when a fault occurs on one.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCBOs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140751224931,"sku":"2CSR275053R1104","price":145.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000103239_400x400_c5279386-8861-4954-9929-93a2f880908a.png?v=1786966409"},{"product_id":"abb-rcbo-dse201-m-c16-16a-30ma-1p-n","title":"ABB RCBO DSE201 M C16 16A 30mA 1P+N","description":"\u003ch2\u003eABB RCBO DSE201 M C16 16A 30mA 1P+N\u003c\/h2\u003e\u003cp\u003eThe ABB DSE201 M C16 AC30 is a 1P+N RCBO rated 16A with 30mA earth fault sensitivity. It provides combined overcurrent and earth leakage protection in a single 2-module device, making it ideal for UAE residential lighting circuits, socket outlets, and individual circuit protection in modern distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1P+N RCBO — MCB and ELCB in a single 2-module device\u003c\/li\u003e\n\u003cli\u003e16A Type C rating for lighting and socket circuits\u003c\/li\u003e\n\u003cli\u003e30mA high-sensitivity earth fault protection\u003c\/li\u003e\n\u003cli\u003eCompact DIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine ABB DSE201 quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDSE201 M C16 AC30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e2CSR275053R1164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eResidential lighting and socket circuit individual protection\u003c\/li\u003e\n\u003cli\u003eCommercial building circuit RCBO protection\u003c\/li\u003e\n\u003cli\u003eBathroom and kitchen circuit earth fault protection\u003c\/li\u003e\n\u003cli\u003eIndividual circuit protection replacing separate MCB + ELCB\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is an RCBO, and how is it different from an MCB or RCCB?\u003c\/strong\u003e\u003cbr\u003eAn RCBO (Residual Current Breaker with Overcurrent protection) combines an MCB and an RCCB in one device — it protects a single circuit against both overload\/short-circuit and earth leakage, instead of needing separate devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e30mA RCBOs are sized for personnel\/shock protection on final circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy use an RCBO instead of a shared RCCB for multiple circuits?\u003c\/strong\u003e\u003cbr\u003eAn RCBO protects one circuit only, so a leakage fault on that circuit trips just that RCBO rather than a shared RCCB covering several circuits — this avoids losing power to unaffected circuits when a fault occurs on one.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCBOs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140751454307,"sku":"2CSR275053R1164","price":145.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000325480_400x400_3428868c-15d5-490c-a055-96e5c7ce1460.jpg?v=1786966413"},{"product_id":"abb-rcbo-dse201-m-c20-20a-100ma-1p-n","title":"ABB RCBO DSE201 M C20 20A 100mA 1P+N","description":"\u003ch2\u003eABB RCBO DSE201 M C20 20A 100mA 1P+N\u003c\/h2\u003e\u003cp\u003eThe ABB DSE201 M C20 AC100 is a 1P+N RCBO rated 20A with 100mA earth fault sensitivity. Ideal for UAE residential and commercial circuit protection where combined overcurrent and fire-protection earth fault detection is required in a single compact DIN-rail module.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1P+N RCBO combining 20A MCB and 100mA ELCB protection\u003c\/li\u003e\n\u003cli\u003e20A Type C rating for power circuits\u003c\/li\u003e\n\u003cli\u003e100mA sensitivity for fire-protection duty\u003c\/li\u003e\n\u003cli\u003eSpace-saving 2-module DIN rail design\u003c\/li\u003e\n\u003cli\u003eGenuine ABB DSE201 quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDSE201 M C20 AC100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e2CSR275053R2204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIndividual power circuit protection in residential DBs\u003c\/li\u003e\n\u003cli\u003eSocket and appliance circuit RCBO protection\u003c\/li\u003e\n\u003cli\u003eCommercial building individual circuit protection\u003c\/li\u003e\n\u003cli\u003eFire-protection RCBO for individual circuits\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is an RCBO, and how is it different from an MCB or RCCB?\u003c\/strong\u003e\u003cbr\u003eAn RCBO (Residual Current Breaker with Overcurrent protection) combines an MCB and an RCCB in one device — it protects a single circuit against both overload\/short-circuit and earth leakage, instead of needing separate devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e100mA RCBOs are sized for fire and equipment protection rather than personal shock protection, which requires 30mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy use an RCBO instead of a shared RCCB for multiple circuits?\u003c\/strong\u003e\u003cbr\u003eAn RCBO protects one circuit only, so a leakage fault on that circuit trips just that RCBO rather than a shared RCCB covering several circuits — this avoids losing power to unaffected circuits when a fault occurs on one.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCBOs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140751487075,"sku":"2CSR275053R2204","price":145.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000100833_400x400_b341e862-e434-4971-8528-a0bf94a0cd61.png?v=1786966418"},{"product_id":"abb-rcbo-dse201-m-c10-10a-100ma-1p-n","title":"ABB RCBO DSE201 M C10 10A 100mA 1P+N","description":"\u003ch2\u003eABB RCBO DSE201 M C10 10A 100mA 1P+N\u003c\/h2\u003e\u003cp\u003eThe ABB DSE201 M C10 AC100 is a 1P+N RCBO rated 10A with 100mA earth fault sensitivity, providing combined overcurrent and fire-protection earth leakage in one compact module for UAE residential and commercial DBs.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1P+N RCBO with 10A MCB and 100mA ELCB protection\u003c\/li\u003e\n\u003cli\u003eType C tripping for general circuits\u003c\/li\u003e\n\u003cli\u003e100mA sensitivity for fire-protection duty\u003c\/li\u003e\n\u003cli\u003eCompact 2-module DIN rail design\u003c\/li\u003e\n\u003cli\u003eGenuine ABB DSE201 quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDSE201 M C10 AC100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIndividual circuit protection in residential and commercial DBs\u003c\/li\u003e\n\u003cli\u003eLighting circuit fire-protection RCBO\u003c\/li\u003e\n\u003cli\u003eIndividual circuit protection replacing MCB + ELCB\u003c\/li\u003e\n\u003cli\u003eCommercial building circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is an RCBO, and how is it different from an MCB or RCCB?\u003c\/strong\u003e\u003cbr\u003eAn RCBO (Residual Current Breaker with Overcurrent protection) combines an MCB and an RCCB in one device — it protects a single circuit against both overload\/short-circuit and earth leakage, instead of needing separate devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e100mA RCBOs are sized for fire and equipment protection rather than personal shock protection, which requires 30mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy use an RCBO instead of a shared RCCB for multiple circuits?\u003c\/strong\u003e\u003cbr\u003eAn RCBO protects one circuit only, so a leakage fault on that circuit trips just that RCBO rather than a shared RCCB covering several circuits — this avoids losing power to unaffected circuits when a fault occurs on one.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCBOs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140751519843,"sku":"DSE201-C10-AC100","price":145.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000103317_400x400_5e04a897-85e4-42cc-a1f6-166d5559adc6.png?v=1786966421"},{"product_id":"abb-rcbo-dse201-m-c16-16a-100ma-1p-n","title":"ABB RCBO DSE201 M C16 16A 100mA 1P+N","description":"\u003ch2\u003eABB RCBO DSE201 M C16 16A 100mA 1P+N\u003c\/h2\u003e\u003cp\u003eThe ABB DSE201 M C16 AC100 is a 1P+N RCBO rated 16A with 100mA earth fault sensitivity for fire-protection individual circuit protection. A compact two-in-one solution for UAE residential and commercial DBs where individual circuit RCBO protection with fire-protection sensitivity is required.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1P+N RCBO with 16A MCB and 100mA ELCB in one module\u003c\/li\u003e\n\u003cli\u003e16A Type C for lighting and general circuits\u003c\/li\u003e\n\u003cli\u003e100mA fire-protection sensitivity\u003c\/li\u003e\n\u003cli\u003eCompact DIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine ABB DSE201 quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDSE201 M C16 AC100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIndividual residential and commercial circuit RCBO protection\u003c\/li\u003e\n\u003cli\u003eLighting and power circuit protection\u003c\/li\u003e\n\u003cli\u003eFire-protection RCBO for 16A circuits\u003c\/li\u003e\n\u003cli\u003eDB individual circuit combined protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is an RCBO, and how is it different from an MCB or RCCB?\u003c\/strong\u003e\u003cbr\u003eAn RCBO (Residual Current Breaker with Overcurrent protection) combines an MCB and an RCCB in one device — it protects a single circuit against both overload\/short-circuit and earth leakage, instead of needing separate devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e100mA RCBOs are sized for fire and equipment protection rather than personal shock protection, which requires 30mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy use an RCBO instead of a shared RCCB for multiple circuits?\u003c\/strong\u003e\u003cbr\u003eAn RCBO protects one circuit only, so a leakage fault on that circuit trips just that RCBO rather than a shared RCCB covering several circuits — this avoids losing power to unaffected circuits when a fault occurs on one.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCBOs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140751585379,"sku":"DSE201-C16-AC100","price":145.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000101721_400x400_d5d4341f-bf6c-4d47-bbbf-a9b2b5aa266a.png?v=1786966432"},{"product_id":"abb-rcbo-dse201-m-c32-32a-30ma-1p-n","title":"ABB RCBO DSE201 M C32 32A 30mA 1P+N","description":"\u003ch2\u003eABB RCBO DSE201 M C32 32A 30mA 1P+N\u003c\/h2\u003e\u003cp\u003eThe ABB DSE201 M C32 AC30 is a 1P+N RCBO rated 32A with 30mA earth fault sensitivity, combining overcurrent and high-sensitivity earth leakage protection for individual high-load circuits in UAE residential and commercial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1P+N RCBO with 32A MCB and 30mA ELCB in one module\u003c\/li\u003e\n\u003cli\u003e32A Type C for high-current circuits\u003c\/li\u003e\n\u003cli\u003e30mA high-sensitivity personal protection\u003c\/li\u003e\n\u003cli\u003eCompact DIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine ABB DSE201 quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDSE201 M C32 AC30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-load individual circuit RCBO protection\u003c\/li\u003e\n\u003cli\u003eCooker, shower, and EV charge point protection\u003c\/li\u003e\n\u003cli\u003e30mA protected power circuits in residential DBs\u003c\/li\u003e\n\u003cli\u003eCommercial high-load circuit RCBO protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is an RCBO, and how is it different from an MCB or RCCB?\u003c\/strong\u003e\u003cbr\u003eAn RCBO (Residual Current Breaker with Overcurrent protection) combines an MCB and an RCCB in one device — it protects a single circuit against both overload\/short-circuit and earth leakage, instead of needing separate devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e30mA RCBOs are sized for personnel\/shock protection on final circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy use an RCBO instead of a shared RCCB for multiple circuits?\u003c\/strong\u003e\u003cbr\u003eAn RCBO protects one circuit only, so a leakage fault on that circuit trips just that RCBO rather than a shared RCCB covering several circuits — this avoids losing power to unaffected circuits when a fault occurs on one.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCBOs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140751618147,"sku":"DSE201-C32-AC30","price":145.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000101683_400x400_59b1cc6b-4ad1-403c-adcc-844ec646772a.png?v=1786966425"},{"product_id":"abb-rcbo-dse201-m-c32-32a-100ma-1p-n","title":"ABB RCBO DSE201 M C32 32A 100mA 1P+N","description":"\u003ch2\u003eABB RCBO DSE201 M C32 32A 100mA 1P+N\u003c\/h2\u003e\u003cp\u003eThe ABB DSE201 M C32 AC100 is a 1P+N RCBO rated 32A with 100mA earth fault sensitivity. Ideal for UAE residential and commercial installations requiring fire-protection earth fault detection combined with 32A overcurrent protection for high-load circuits such as cookers and large appliances.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1P+N RCBO with 32A MCB and 100mA ELCB combined\u003c\/li\u003e\n\u003cli\u003e32A Type C for high-current load circuits\u003c\/li\u003e\n\u003cli\u003e100mA fire-protection sensitivity\u003c\/li\u003e\n\u003cli\u003eCompact DIN rail module\u003c\/li\u003e\n\u003cli\u003eGenuine ABB DSE201 quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDSE201 M C32 AC100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-load individual circuit RCBO with fire protection\u003c\/li\u003e\n\u003cli\u003eCooker and appliance circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial power circuit protection\u003c\/li\u003e\n\u003cli\u003eIndividual fire-protection RCBO in DBs\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is an RCBO, and how is it different from an MCB or RCCB?\u003c\/strong\u003e\u003cbr\u003eAn RCBO (Residual Current Breaker with Overcurrent protection) combines an MCB and an RCCB in one device — it protects a single circuit against both overload\/short-circuit and earth leakage, instead of needing separate devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e100mA RCBOs are sized for fire and equipment protection rather than personal shock protection, which requires 30mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy use an RCBO instead of a shared RCCB for multiple circuits?\u003c\/strong\u003e\u003cbr\u003eAn RCBO protects one circuit only, so a leakage fault on that circuit trips just that RCBO rather than a shared RCCB covering several circuits — this avoids losing power to unaffected circuits when a fault occurs on one.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCBOs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140751650915,"sku":"DSE201-C32-AC100","price":150.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_c6d667a6-cbd5-4f41-a4f8-c0318b1c5614.png?v=1786966486"},{"product_id":"bb-dse201-m-c10-ac100-1p-n-10a-100ma-rcbo","title":"ABB 10A 100mA 1P+N - DSE201 M C16 AC100 RCBO","description":"\u003ch2\u003eABB DSE201 M 1P+N RCBO 10A 100mA\u003c\/h2\u003e\n\u003cp\u003eThe DSE201 M C10 AC100 is a 1P+N electronic residual current circuit breaker with overcurrent protection (RCBO) in a compact one-module width, combining overload and short-circuit protection with residual current protection against earth fault currents in a single device. Featuring Type AC sensitivity for sinusoidal alternating earth fault currents and Type C tripping for overload protection, it is designed for single-phase end-user circuits in residential and commercial UAE distribution boards where combined overcurrent and earth leakage protection is required in minimal panel space.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCombined overcurrent and residual current protection in a single 1-module-wide device, saving distribution board space\u003c\/li\u003e\n  \u003cli\u003e10A Type C overcurrent protection paired with 100mA Type AC residual current sensitivity\u003c\/li\u003e\n  \u003cli\u003eProtection against indirect contacts and additional protection against direct contacts\u003c\/li\u003e\n  \u003cli\u003eUnswitched neutral with flying lead connections for neutral and functional earth, simplifying installation\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDSE201 M C10 AC100\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Residual Current\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eResidual Current Type\u003c\/td\u003e\n\u003ctd\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Ultimate Breaking Capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e15 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Short-Circuit Capacity\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e230\/240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e500V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eTerminals IP20 \/ Housing IP40\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCombined overcurrent and earth leakage protection for single-phase end-user circuits\u003c\/li\u003e\n  \u003cli\u003eResidential distribution boards requiring compact, space-saving RCBO protection\u003c\/li\u003e\n  \u003cli\u003eCommercial circuit protection where indirect and direct contact protection is required\u003c\/li\u003e\n  \u003cli\u003eRetrofit upgrade from separate MCB and RCCB to a single combined device in UAE installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is an RCBO, and how is it different from an MCB or RCCB?\u003c\/strong\u003e\u003cbr\u003eAn RCBO (Residual Current Breaker with Overcurrent protection) combines an MCB and an RCCB in one device — it protects a single circuit against both overload\/short-circuit and earth leakage, instead of needing separate devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e100mA RCBOs are sized for fire and equipment protection rather than personal shock protection, which requires 30mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy use an RCBO instead of a shared RCCB for multiple circuits?\u003c\/strong\u003e\u003cbr\u003eAn RCBO protects one circuit only, so a leakage fault on that circuit trips just that RCBO rather than a shared RCCB covering several circuits — this avoids losing power to unaffected circuits when a fault occurs on one.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCBOs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44346873938019,"sku":"DSE201 M C16","price":115.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000399333_400x400_6e1b745c-9c6b-422d-be42-de2af998f484.png?v=1787498880"},{"product_id":"abb-dse201-m-c20-ac30-1p-n-20a-30ma-rcbo","title":"ABB DSE201 M 1P+N RCBO 20A 30mA","description":"\u003ch2\u003eABB DSE201 M 1P+N RCBO 20A 30mA\u003c\/h2\u003e\n\u003cp\u003eThe DSE201 M C20 AC30 is a 1P+N electronic residual current circuit breaker with overcurrent protection (RCBO) in a compact one-module width, combining overload and short-circuit protection with high-sensitivity residual current protection in a single device. With a 30mA Type AC sensitivity, it provides additional protection against direct contacts as well as protection against indirect contacts, making it well suited to end-user single-phase circuits in UAE residential and commercial distribution boards where personnel safety is a priority.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCombined overcurrent and residual current protection in a single 1-module-wide device, saving distribution board space\u003c\/li\u003e\n  \u003cli\u003e20A Type C overcurrent protection paired with 30mA Type AC residual current sensitivity for personnel protection\u003c\/li\u003e\n  \u003cli\u003eAdditional protection against direct contacts as well as protection against indirect contacts\u003c\/li\u003e\n  \u003cli\u003eUnswitched neutral with flying lead connections for neutral and functional earth, simplifying installation\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDSE201 M C20 AC30\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Residual Current\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eResidual Current Type\u003c\/td\u003e\n\u003ctd\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Ultimate Breaking Capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e15 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Short-Circuit Capacity\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e230\/240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e500V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eTerminals IP20 \/ Housing IP40\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePersonnel protection circuits requiring 30mA sensitivity in residential and commercial installations\u003c\/li\u003e\n  \u003cli\u003eBathroom, kitchen, and outdoor socket circuit protection in UAE villas and apartments\u003c\/li\u003e\n  \u003cli\u003eCombined overcurrent and earth leakage protection where direct contact safety is required\u003c\/li\u003e\n  \u003cli\u003eRetrofit upgrade from separate MCB and RCCB to a single combined device in distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is an RCBO, and how is it different from an MCB or RCCB?\u003c\/strong\u003e\u003cbr\u003eAn RCBO (Residual Current Breaker with Overcurrent protection) combines an MCB and an RCCB in one device — it protects a single circuit against both overload\/short-circuit and earth leakage, instead of needing separate devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e30mA RCBOs are sized for personnel\/shock protection on final circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy use an RCBO instead of a shared RCCB for multiple circuits?\u003c\/strong\u003e\u003cbr\u003eAn RCBO protects one circuit only, so a leakage fault on that circuit trips just that RCBO rather than a shared RCCB covering several circuits — this avoids losing power to unaffected circuits when a fault occurs on one.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCBOs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44346899726435,"sku":"1SDA067398R1","price":115.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000399303_400x400_8f89d56a-9cb1-4717-afe1-b774ea3ec4fe.png?v=1787498880"},{"product_id":"abb-dse201-m-c20-ac30-1p-n-20a-32ma-rcbo","title":"ABB RCBO 20A 30mA 1P+N - DSE201 M C16 AC100","description":"\u003ch2\u003eABB DSE201 M 1P+N 20A 30mA Type AC RCBO\u003c\/h2\u003e\n\u003cp\u003eThe DSE201 M C20 AC30 is a 1P+N electronic residual current circuit breaker with overcurrent protection (RCBO), combining overload and short-circuit protection with 30mA earth fault sensitivity in a single-module width. It protects end-user single-phase circuits against both overcurrent faults and sinusoidal AC earth leakage currents, making it a compact, space-saving choice for distribution boards across UAE residential and commercial installations.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1P+N configuration in a single 18mm module width, saving space in compact distribution boards\u003c\/li\u003e\n  \u003cli\u003e20A rated current with Type C tripping characteristic for lighting and general power circuits\u003c\/li\u003e\n  \u003cli\u003e30mA Type AC residual current sensitivity for protection against indirect and direct contact\u003c\/li\u003e\n  \u003cli\u003e10kA rated residual breaking capacity with unswitched neutral and flying earth lead for flexible installation\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB quality — reliable protection to IEC 61009-1 and IEC 61009-2-2 standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDSE201 M C20 AC30\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eResidual Current Type\u003c\/td\u003e\n\u003ctd\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Residual Current\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Ultimate Breaking Capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e15kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Residual Breaking Capacity\u003c\/td\u003e\n\u003ctd\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230\/240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCombined overcurrent and earth leakage protection for lighting circuits in residential DBs\u003c\/li\u003e\n  \u003cli\u003eSocket and power circuit protection requiring additional direct-contact protection\u003c\/li\u003e\n  \u003cli\u003eSpace-constrained distribution boards in villas and apartment consumer units across the UAE\u003c\/li\u003e\n  \u003cli\u003eUpgrade of existing MCB-only circuits to add RCD protection without extra board space\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is an RCBO, and how is it different from an MCB or RCCB?\u003c\/strong\u003e\u003cbr\u003eAn RCBO (Residual Current Breaker with Overcurrent protection) combines an MCB and an RCCB in one device — it protects a single circuit against both overload\/short-circuit and earth leakage, instead of needing separate devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e30mA RCBOs are sized for personnel\/shock protection on final circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy use an RCBO instead of a shared RCCB for multiple circuits?\u003c\/strong\u003e\u003cbr\u003eAn RCBO protects one circuit only, so a leakage fault on that circuit trips just that RCBO rather than a shared RCCB covering several circuits — this avoids losing power to unaffected circuits when a fault occurs on one.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCBOs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44358033735779,"sku":"2CSR275053R2164","price":115.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000399303_400x400_258c6322-db33-4664-8087-6a78375d19ed.png?v=1787498893"}],"url":"https:\/\/www.deluxeuae.com\/collections\/rcbos.oembed","provider":"Deluxe Electricals","version":"1.0","type":"link"}