{"title":"MCCBs","description":"\u003cp\u003eShop moulded case circuit breakers for main incomers, sub-mains and motor feeders across the UAE — ABB Formula, Tmax XT and Emax ranges alongside Hager three-pole MCCBs, 63A to 2500A frames.\u003c\/p\u003e\u003ch2\u003eMCB or MCCB?\u003c\/h2\u003e\u003cp\u003eAn \u003cstrong\u003eMCB\u003c\/strong\u003e is a miniature breaker on DIN rail with a fixed trip, used for final circuits in homes and light commercial boards. An \u003cstrong\u003eMCCB\u003c\/strong\u003e is moulded-case: larger, rated far higher, and usually with an adjustable release so one frame covers a band of currents. Past roughly 100A, or where the trip must be tuned to a cable or motor, you are into MCCB territory. Above that sit air circuit breakers such as the ABB Emax, on 1600A and 2500A incomers.\u003c\/p\u003e\u003ch2\u003eHow do I read TMF, TMD and the two numbers?\u003c\/h2\u003e\u003cp\u003eA code such as \u003cstrong\u003eTMF 160-1600\u003c\/strong\u003e describes a thermomagnetic release: the first figure is the continuous current in amps, the second the instantaneous magnetic trip that handles a short circuit. \u003cstrong\u003eTMD\u003c\/strong\u003e releases let you adjust the thermal setting within a band; \u003cstrong\u003eTMF\u003c\/strong\u003e is fixed. Ekip LSI and LSIG electronic trip units replace both with adjustable long-time, short-time and instantaneous settings, plus earth-fault on LSIG.\u003c\/p\u003e\u003ch2\u003eWhat breaking capacity do I need?\u003c\/h2\u003e\u003cp\u003eBreaking capacity in kA is the fault current the breaker can interrupt safely, and 25kA is common on sub-mains, with more needed nearer the transformer. It comes from the prospective short-circuit current calculated at that point — design work for a licensed electrical engineer or contractor, never a guess. Tell us the board position and load and we will quote frames and trip units in AED.\u003c\/p\u003e","products":[{"product_id":"abb-mccb-a1n-125-tmf-40-400-1-pole-40a-25ka","title":"ABB MCCB A1N 125 TMF 40-400 1-Pole 40A 25kA","description":"\u003ch2\u003eABB MCCB A1N 125 TMF 40-400 1-Pole 40A 25kA\u003c\/h2\u003e\u003cp\u003eThe ABB A1N 125 TMF 40-400 is a 1-pole MCCB with 25kA breaking capacity, adjustable thermal-magnetic trip from 40–400A (set at 40A), designed for high-current single-pole circuit protection in UAE industrial and commercial switchgear. Its 25kA fault withstand makes it suitable for high fault-level incoming protection applications.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1-pole MCCB with 25kA breaking capacity\u003c\/li\u003e\n\u003cli\u003eAdjustable TMF trip unit: 40–400A\u003c\/li\u003e\n\u003cli\u003eHigh breaking capacity for industrial switchgear applications\u003c\/li\u003e\n\u003cli\u003eCompact MCCB design for space-efficient panel installation\u003c\/li\u003e\n\u003cli\u003eGenuine ABB Formula A1 MCCB quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eA1N 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Unit\u003c\/td\u003e\n\u003ctd\u003eTMF 40-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e25kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSingle-pole high fault-level circuit protection\u003c\/li\u003e\n\u003cli\u003eIndustrial switchgear and MCC applications\u003c\/li\u003e\n\u003cli\u003eSub-main feeder protection in commercial buildings\u003c\/li\u003e\n\u003cli\u003eHigh fault-level panel incoming protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 1-pole device, sized for the corresponding single or three-phase supply arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140749422691,"sku":"1SDA066689R1","price":145.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000045317_400x400_5c1444de-c2fd-4062-a6d0-699d1b792a58.jpg?v=1786966368"},{"product_id":"abb-mccb-a1c-125-tmf-40-400-3-pole","title":"ABB MCCB A1C 125 TMF 40-400 3-Pole","description":"\u003ch2\u003eABB MCCB A1C 125 TMF 40-400 3-Pole\u003c\/h2\u003e\u003cp\u003eThe ABB A1C 125 TMF 40-400 3P is a 3-pole MCCB from the ABB Formula A1 series with an adjustable thermal-magnetic trip unit. Providing reliable three-phase circuit protection with high breaking capacity, it is used in UAE commercial and industrial panels for sub-main feeder and incoming circuit protection.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pole MCCB with adjustable TMF trip unit 40–400A\u003c\/li\u003e\n\u003cli\u003eHigh breaking capacity for industrial switchgear applications\u003c\/li\u003e\n\u003cli\u003eFixed front operation with trip indication\u003c\/li\u003e\n\u003cli\u003eCompact design for panel space efficiency\u003c\/li\u003e\n\u003cli\u003eGenuine ABB Formula A1 MCCB quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA1C 125 TMF 40-400 3p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e1SDA066713R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Unit\u003c\/td\u003e\n\u003ctd\u003eTMF 40–400A (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThree-phase sub-main feeder circuit protection\u003c\/li\u003e\n\u003cli\u003eIndustrial switchgear and panel incoming protection\u003c\/li\u003e\n\u003cli\u003eCommercial building MCC and distribution applications\u003c\/li\u003e\n\u003cli\u003eHigh fault-level three-phase circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole device, sized for the corresponding single or three-phase supply arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140749455459,"sku":"1SDA066713R1","price":190.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000045321_400x400_a99a49fc-8524-41dc-b53b-fa92c4d4063d.jpg?v=1786966373"},{"product_id":"abb-mccb-xt1c-160-tmd-80-800-3-pole","title":"ABB MCCB XT1C 160 TMD 80-800 3-Pole","description":"\u003ch2\u003eABB MCCB XT1C 160 TMD 80-800 3-Pole\u003c\/h2\u003e\n\u003cp\u003eThe ABB MCCB XT1C 160 TMD 80-800 3P is a 3-pole MCCB from the Tmax XT1 series with an 80–800A adjustable TMD trip unit and 25kA breaking capacity at 415V. It provides reliable overcurrent and short-circuit protection for sub-main feeders and large power circuits in UAE commercial and industrial installations.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3-pole MCCB with adjustable TMD trip unit 80–800A\u003c\/li\u003e\n\u003cli\u003e25kA breaking capacity at 415V AC\u003c\/li\u003e\n\u003cli\u003eFixed front mounting for panel and switchgear installation\u003c\/li\u003e\n\u003cli\u003eCompact Tmax XT1 design\u003c\/li\u003e\n\u003cli\u003eGenuine ABB Tmax XT quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 99.915%; height: 156.818px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003cth style=\"width: 37.1141%; height: 19.6023px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"width: 60.3175%; height: 19.6023px;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 37.1141%; height: 19.6023px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 60.3175%; height: 19.6023px;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 37.1141%; height: 19.6023px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 60.3175%; height: 19.6023px;\"\u003eXT1C 160 TMD 80-800 3p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 37.1141%; height: 19.6023px;\"\u003eArticle Number\u003c\/td\u003e\n\u003ctd style=\"width: 60.3175%; height: 19.6023px;\"\u003e1SDA067396R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 37.1141%; height: 19.6023px;\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"width: 60.3175%; height: 19.6023px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 37.1141%; height: 19.6023px;\"\u003eTrip Unit\u003c\/td\u003e\n\u003ctd style=\"width: 60.3175%; height: 19.6023px;\"\u003eTMD 80–800A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 37.1141%; height: 19.6023px;\"\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd style=\"width: 60.3175%; height: 19.6023px;\"\u003e25kA @ 415V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 37.1141%; height: 19.6023px;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"width: 60.3175%; height: 19.6023px;\"\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree-phase sub-main feeder protection\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial distribution board incoming\u003c\/li\u003e\n\u003cli\u003eMCC and switchgear circuit protection\u003c\/li\u003e\n\u003cli\u003eHigh-current circuit protection in large buildings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole device, sized for the corresponding single or three-phase supply arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140749488227,"sku":"1SDA067396R1","price":250.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9IBA248846_400x400_b38b808f-b32a-4484-8bd2-968f0e4fd772.png?v=1786966375"},{"product_id":"abb-mccb-xt1c-160-tmd-100-1000-3-pole","title":"ABB MCCB XT1C 160 TMD 100-1000 3-Pole","description":"\u003ch2\u003eABB MCCB XT1C 160 TMD 100-1000 3-Pole\u003c\/h2\u003e\u003cp\u003eThe ABB XT1C 160 TMD 100-1000 3P is a 3-pole MCCB with an adjustable 100–1000A TMD trip for protection of larger sub-main feeder circuits and main incoming applications in UAE commercial and industrial buildings. Part of the compact and reliable ABB Tmax XT1 MCCB range.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pole MCCB with adjustable TMD trip unit 100–1000A\u003c\/li\u003e\n\u003cli\u003e25kA breaking capacity at 415V AC\u003c\/li\u003e\n\u003cli\u003eFixed front mounting\u003c\/li\u003e\n\u003cli\u003eCompact Tmax XT1 series design\u003c\/li\u003e\n\u003cli\u003eGenuine ABB Tmax XT quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eXT1C 160 TMD 100-1000 3p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e1SDA067397R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Unit\u003c\/td\u003e\n\u003ctd\u003eTMD 100–1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e25kA @ 415V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLarge three-phase sub-main feeder protection\u003c\/li\u003e\n\u003cli\u003eIndustrial and commercial incoming circuit protection\u003c\/li\u003e\n\u003cli\u003eHigh-current MCC and distribution switchgear\u003c\/li\u003e\n\u003cli\u003eLarge building main distribution board protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole device, sized for the corresponding single or three-phase supply arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140749520995,"sku":"1SDA067397R1","price":235.3,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9IBA248846_400x400_a0e4f861-6ba4-4c33-bc10-8508463560ce.png?v=1786966379"},{"product_id":"abb-mccb-xt1c-160-tmd-40-450-4-pole","title":"ABB MCCB XT1C 160 TMD 40-450 4-Pole","description":"\u003ch2\u003eABB MCCB XT1C 160 TMD 40-450 4-Pole\u003c\/h2\u003e\u003cp\u003eThe ABB XT1C 160 TMD 40-450 4P is a 4-pole MCCB for three-phase + neutral circuit protection in UAE commercial and industrial switchgear. With an adjustable 40–450A trip unit and 25kA breaking capacity, it provides full four-wire protection for main incoming and sub-main feeder circuits.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4-pole MCCB with adjustable TMD trip 40–450A\u003c\/li\u003e\n\u003cli\u003eFour-pole switching for 3-phase + neutral main incoming applications\u003c\/li\u003e\n\u003cli\u003e25kA breaking capacity at 415V\u003c\/li\u003e\n\u003cli\u003eFixed front mounting for panel installation\u003c\/li\u003e\n\u003cli\u003eGenuine ABB Tmax XT1 quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eXT1C 160 TMD 40-450 4p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e1SDA070110R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Unit\u003c\/td\u003e\n\u003ctd\u003eTMD 40–450A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e25kA @ 415V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFour-pole incoming circuit protection in commercial DBs\u003c\/li\u003e\n\u003cli\u003eThree-phase + neutral sub-main feeder protection\u003c\/li\u003e\n\u003cli\u003eIndustrial and commercial MCC and switchgear\u003c\/li\u003e\n\u003cli\u003eLarge building main distribution incoming protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 4-pole device, sized for the corresponding single or three-phase supply arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140749553763,"sku":"1SDA067402R1","price":350.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9IBA255342_400x400_03359952-19ee-48f3-b454-e5a8cbe3783a.png?v=1786966381"},{"product_id":"abb-mccb-xt2s-160-tmd-20-300-3-pole-50-c","title":"ABB MCCB XT2S 160 TMD 20-300 3-Pole 50°C","description":"\u003ch2\u003eABB MCCB XT2S 160 TMD 20-300 3-Pole 50°C\u003c\/h2\u003e\u003cp\u003eThe ABB XT2S 160 TMD 20-300 3P is a 3-pole MCCB from the Tmax XT2S series with a 20–300A adjustable TMD trip unit rated at 50°C for UAE high-ambient installations. Its 36kA breaking capacity at 415V provides robust protection for sub-main feeders and motor circuits in demanding industrial environments.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pole MCCB with 20–300A adjustable TMD trip\u003c\/li\u003e\n\u003cli\u003e36kA breaking capacity at 415V AC\u003c\/li\u003e\n\u003cli\u003eRated at 50°C for high-ambient UAE installations\u003c\/li\u003e\n\u003cli\u003eFixed front mounting\u003c\/li\u003e\n\u003cli\u003eGenuine ABB Tmax XT2S quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eXT2S 160 TMD 20-300 3p F F 50C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e1SDA070138R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Unit\u003c\/td\u003e\n\u003ctd\u003eTMD 20–300A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e36kA @ 415V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Rating\u003c\/td\u003e\n\u003ctd\u003e50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSub-main feeder protection in high-ambient UAE panels\u003c\/li\u003e\n\u003cli\u003eIndustrial MCC and motor circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial building sub-main MCCB protection\u003c\/li\u003e\n\u003cli\u003eHigh breaking capacity distribution switchgear\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole device, sized for the corresponding single or three-phase supply arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140749586531,"sku":"1SDA067551R1","price":525.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9IBA248849_400x400_3.png?v=1786966384"},{"product_id":"abb-mccb-xt2s-160-tmd-25-300-3-pole-50-c","title":"ABB MCCB XT2S 160 TMD 25-300 3-Pole 50°C","description":"\u003ch2\u003eABB MCCB XT2S 160 TMD 25-300 3-Pole 50°C\u003c\/h2\u003e\u003cp\u003eThe ABB XT2S 160 TMD 25-300 3P is a 3-pole MCCB rated at 50°C ambient with a 25–300A adjustable TMD trip and 36kA breaking capacity. It provides reliable protection for UAE industrial and commercial panels where high-ambient temperature conditions and high fault current levels are present.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pole MCCB with 25–300A adjustable TMD trip\u003c\/li\u003e\n\u003cli\u003e36kA breaking capacity at 415V, rated at 50°C\u003c\/li\u003e\n\u003cli\u003eSuitable for high-ambient temperature UAE panels\u003c\/li\u003e\n\u003cli\u003eFixed front mounting\u003c\/li\u003e\n\u003cli\u003eGenuine ABB Tmax XT2S quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eXT2S 160 TMD 25-300 3p F F 50C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e1SDA070139R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Unit\u003c\/td\u003e\n\u003ctd\u003eTMD 25–300A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e36kA @ 415V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Rating\u003c\/td\u003e\n\u003ctd\u003e50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIndustrial high-ambient MCCB protection\u003c\/li\u003e\n\u003cli\u003eSub-main circuit protection in commercial buildings\u003c\/li\u003e\n\u003cli\u003eMCC and switchgear distribution panels\u003c\/li\u003e\n\u003cli\u003eProcess plant and industrial facility protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole device, sized for the corresponding single or three-phase supply arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140749619299,"sku":"1SDA067552R1","price":625.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9IBA248849_400x400_2.png?v=1786966389"},{"product_id":"abb-mccb-xt2s-160-tmd-40-400-3-pole-50-c","title":"ABB MCCB XT2S 160 TMD 40-400 3-Pole 50°C","description":"\u003ch2\u003eABB MCCB XT2S 160 TMD 40-400 3-Pole 50°C\u003c\/h2\u003e\u003cp\u003eThe ABB XT2S 160 TMD 40-400 3P is a 3-pole MCCB with a 40–400A adjustable TMD trip and 36kA breaking capacity at 415V, rated for 50°C ambient conditions. It delivers reliable circuit protection for UAE high-ambient industrial and commercial switchgear, sub-main feeders, and motor circuit applications.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pole MCCB with 40–400A adjustable TMD trip\u003c\/li\u003e\n\u003cli\u003e36kA breaking capacity at 415V\u003c\/li\u003e\n\u003cli\u003e50°C ambient temperature rating for UAE conditions\u003c\/li\u003e\n\u003cli\u003eFixed front mounting\u003c\/li\u003e\n\u003cli\u003eGenuine ABB Tmax XT2S quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eXT2S 160 TMD 40-400 3p F F 50C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e1SDA070141R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Unit\u003c\/td\u003e\n\u003ctd\u003eTMD 40–400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e36kA @ 415V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Rating\u003c\/td\u003e\n\u003ctd\u003e50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThree-phase sub-main feeder MCCB protection\u003c\/li\u003e\n\u003cli\u003eIndustrial motor circuit and MCC protection\u003c\/li\u003e\n\u003cli\u003eCommercial building high fault-level panels\u003c\/li\u003e\n\u003cli\u003eHigh-ambient UAE industrial switchgear\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole device, sized for the corresponding single or three-phase supply arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140749652067,"sku":"1SDA067554R1","price":625.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9IBA248849_400x400_1.png?v=1786966391"},{"product_id":"abb-mccb-xt2s-160-tmd-63-630-3-pole-50-c","title":"ABB MCCB XT2S 160 TMD 63-630 3-Pole 50°C","description":"\u003ch2\u003eABB MCCB XT2S 160 TMD 63-630 3-Pole 50°C\u003c\/h2\u003e\u003cp\u003eThe ABB XT2S 160 TMD 63-630 3P is a 3-pole MCCB with a 63–630A TMD trip unit and 36kA breaking capacity at 415V, rated at 50°C. Suited for high-current sub-main feeder and incoming circuit protection in UAE high-ambient industrial and commercial switchgear panels.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pole MCCB with 63–630A adjustable TMD trip\u003c\/li\u003e\n\u003cli\u003e36kA breaking capacity at 415V\u003c\/li\u003e\n\u003cli\u003e50°C ambient rating for UAE high-temperature environments\u003c\/li\u003e\n\u003cli\u003eFixed front mounting\u003c\/li\u003e\n\u003cli\u003eGenuine ABB Tmax XT2S quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eXT2S 160 TMD 63-630 3p F F 50C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e1SDA070143R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Unit\u003c\/td\u003e\n\u003ctd\u003eTMD 63–630A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e36kA @ 415V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Rating\u003c\/td\u003e\n\u003ctd\u003e50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-current three-phase incoming and feeder protection\u003c\/li\u003e\n\u003cli\u003eIndustrial MCC and large switchgear applications\u003c\/li\u003e\n\u003cli\u003eCommercial building main MCCB protection\u003c\/li\u003e\n\u003cli\u003eHigh fault-level sub-main distribution protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole device, sized for the corresponding single or three-phase supply arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140749684835,"sku":"1SDA070143R1","price":450.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9IBA248849_400x400_1c1ff482-2d31-4763-9fce-2604be4db83d.png?v=1786966394"},{"product_id":"abb-mccb-xt3n-250-tmd-200-2000-3-pole-50-c","title":"ABB MCCB XT3N 250 TMD 200-2000 3-Pole 50°C","description":"\u003ch2\u003eABB MCCB XT3N 250 TMD 200-2000 3-Pole 50°C\u003c\/h2\u003e\u003cp\u003eThe ABB XT3N 250 TMD 200-2000 3P is a 3-pole MCCB from the Tmax XT3 series with a high-range 200–2000A adjustable TMD trip and 36kA breaking capacity at 415V, rated at 50°C. It is designed for main incoming and heavy-duty feeder protection in UAE large commercial and industrial switchgear.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pole MCCB with 200–2000A adjustable TMD trip\u003c\/li\u003e\n\u003cli\u003e36kA breaking capacity at 415V\u003c\/li\u003e\n\u003cli\u003e50°C rated for UAE high-ambient environments\u003c\/li\u003e\n\u003cli\u003eFixed front mounting\u003c\/li\u003e\n\u003cli\u003eGenuine ABB Tmax XT3N quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eXT3N 250 TMD 200-2000 3p F F 50C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e1SDA070162R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Unit\u003c\/td\u003e\n\u003ctd\u003eTMD 200–2000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e36kA @ 415V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Rating\u003c\/td\u003e\n\u003ctd\u003e50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMain incoming protection in large industrial and commercial switchgear\u003c\/li\u003e\n\u003cli\u003eHeavy feeder and distribution circuit protection\u003c\/li\u003e\n\u003cli\u003eLarge industrial plant and facility MCCs\u003c\/li\u003e\n\u003cli\u003eData centre and critical infrastructure panel protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole device, sized for the corresponding single or three-phase supply arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140749750371,"sku":"1SDA070162R1","price":800.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9IBA255129_400x400_d691c8da-1190-4a0e-aec9-c1a8a2c14472.png?v=1786966401"},{"product_id":"abb-mccb-xt5n-400-tma-320-3200-3-pole","title":"ABB MCCB XT5N 400 TMA 320-3200 3-Pole","description":"\u003ch2\u003eABB MCCB XT5N 400 TMA 320-3200 3-Pole\u003c\/h2\u003e\u003cp\u003eThe ABB XT5N 400 TMA 320-3200 3P is a 3-pole MCCB from the Tmax XT5 series with a 320–3200A TMA trip unit and 36kA breaking capacity. Designed for main incoming and primary distribution protection in UAE large industrial facilities, data centres, and commercial building switchgear requiring premium high-current MCCB performance.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pole MCCB with 320–3200A adjustable TMA trip\u003c\/li\u003e\n\u003cli\u003e36kA breaking capacity at 415V\u003c\/li\u003e\n\u003cli\u003eHigh-current main incoming and primary distribution protection\u003c\/li\u003e\n\u003cli\u003eRobust Tmax XT5 construction for demanding applications\u003c\/li\u003e\n\u003cli\u003eGenuine ABB Tmax XT5N quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eXT5N 400 TMA 320-3200 3p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e1SDA100344R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Unit\u003c\/td\u003e\n\u003ctd\u003eTMA 320–3200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e36kA @ 415V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMain incoming protection for large industrial and commercial buildings\u003c\/li\u003e\n\u003cli\u003ePrimary distribution and switchgear incoming\u003c\/li\u003e\n\u003cli\u003eIndustrial MCC and large process plant protection\u003c\/li\u003e\n\u003cli\u003eData centre and critical infrastructure main protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole device, sized for the corresponding single or three-phase supply arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140749881443,"sku":"1SDA100344R1","price":1800.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9IBA261444_400x400_1.png?v=1786966398"},{"product_id":"abb-mccb-xt5n-400-tma-400-4000-3-pole","title":"ABB MCCB XT5N 400 TMA 400-4000 3-Pole","description":"\u003ch2\u003eABB MCCB XT5N 400 TMA 400-4000 3-Pole\u003c\/h2\u003e\u003cp\u003eThe ABB XT5N 400 TMA 400-4000 3P is a high-capacity 3-pole MCCB with a 400–4000A TMA trip unit and 36kA breaking capacity at 415V. It provides main incoming protection for the largest UAE industrial facilities, substation switchgear, and critical infrastructure where premium high-current MCCB protection is specified.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pole MCCB with 400–4000A TMA trip for maximum current applications\u003c\/li\u003e\n\u003cli\u003e36kA breaking capacity at 415V\u003c\/li\u003e\n\u003cli\u003eHeavy-duty main incoming switchgear protection\u003c\/li\u003e\n\u003cli\u003eFixed front robust Tmax XT5 construction\u003c\/li\u003e\n\u003cli\u003eGenuine ABB Tmax XT5N quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eXT5N 400 TMA 400-4000 3p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Unit\u003c\/td\u003e\n\u003ctd\u003eTMA 400–4000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e36kA @ 415V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVery high-current main incoming switchgear protection\u003c\/li\u003e\n\u003cli\u003eIndustrial substation and primary distribution incoming\u003c\/li\u003e\n\u003cli\u003eLarge process plant and critical facility protection\u003c\/li\u003e\n\u003cli\u003eMajor commercial building main distribution protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole device, sized for the corresponding single or three-phase supply arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140750110819,"sku":"1SDA100345R1","price":1800.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000229787_400x400_a22ddda0-8639-4d03-a551-731be17733a4.jpg?v=1786966404"},{"product_id":"abb-mccb-xt5n-400-tma-400-4000-3-pole-50-c","title":"ABB MCCB XT5N 400 TMA 400-4000 3-Pole 50°C","description":"\u003ch2\u003eABB MCCB XT5N 400 TMA 400-4000 3-Pole 50°C\u003c\/h2\u003e\u003cp\u003eThe ABB XT5N 400 TMA 400-4000 3P 50°C is a 3-pole MCCB with TMA 400–4000A trip, 36kA breaking capacity, and 50°C ambient temperature rating for UAE high-ambient industrial main incoming and primary distribution protection applications. Its 50°C rating ensures rated performance even in the hottest UAE switchroom environments.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pole MCCB with 400–4000A TMA trip\u003c\/li\u003e\n\u003cli\u003e36kA breaking capacity at 415V\u003c\/li\u003e\n\u003cli\u003e50°C ambient rating for UAE high-temperature installations\u003c\/li\u003e\n\u003cli\u003eMain incoming switchgear duty\u003c\/li\u003e\n\u003cli\u003eGenuine ABB Tmax XT5N quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eXT5N 400 TMA 400-4000 3p F F 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e1SDA100349R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Unit\u003c\/td\u003e\n\u003ctd\u003eTMA 400–4000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e36kA @ 415V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Rating\u003c\/td\u003e\n\u003ctd\u003e50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMain incoming protection in high-ambient UAE switchgear rooms\u003c\/li\u003e\n\u003cli\u003ePrimary distribution incoming for large commercial buildings\u003c\/li\u003e\n\u003cli\u003eIndustrial substation main incoming protection\u003c\/li\u003e\n\u003cli\u003eCritical infrastructure and data centre main MCCB\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole device, sized for the corresponding single or three-phase supply arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140750635107,"sku":"1SDA100349R1","price":1100.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9IBA261444_400x400_6f916da6-6837-46a9-8246-351dc624e4f7.png?v=1786966405"},{"product_id":"hager-ha100z-3-pole-100a-mccb","title":"Hager MCCB 3-Pole 100A HHA100Z","description":"\u003cdiv\u003e\n\u003ch2\u003eHager HHA100Z 3-Pole 100A MCCB\u003c\/h2\u003e\n\u003cp\u003eThe Hager HHA100Z is a 3-pole, 100A moulded case circuit breaker (MCCB) with a fixed thermal-magnetic trip unit, built for sub-main feeder and incoming circuit protection in UAE commercial and industrial distribution boards. It handles higher fault currents than a standard MCB, making it the right choice for main and sub-main protection on three-phase supplies.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3-pole, 100A rated current for three-phase incoming\/feeder protection\u003c\/li\u003e\n\u003cli\u003eFixed thermal-magnetic (TM F\/F) trip unit, fixed front DIN-rail mounting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: Icu 25kA @ 400V AC \/ 35kA @ 240V AC (IEC 60947-2)\u003c\/li\u003e\n\u003cli\u003eService breaking capacity: Ics 25kA @ 230V AC \/ 20kA @ 400V AC\u003c\/li\u003e\n\u003cli\u003eRated operational voltage (Ue): 220–415V AC, 50–60Hz\u003c\/li\u003e\n\u003cli\u003eIP4X protection, compact frame (130 × 75 × 68mm)\u003c\/li\u003e\n\u003cli\u003eRated for 20,000 mechanical and 10,000 electrical operations\u003c\/li\u003e\n\u003cli\u003eGenuine Hager, Made in France, compliant with IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHHA100Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eMCCB (Moulded Case Circuit Breaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage (Ue)\u003c\/td\u003e\n\u003ctd\u003e220–415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e25 kA @ 400V AC \/ 35 kA @ 240V AC \/ 4 kA @ 690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Breaking Capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003e25 kA @ 230V AC \/ 20 kA @ 400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Unit\u003c\/td\u003e\n\u003ctd\u003eTM F\/F (thermal-magnetic, fixed settings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFixed, front-mounted, DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd\u003e4–95 mm² rigid \/ 4–70 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndurance\u003c\/td\u003e\n\u003ctd\u003e20,000 mechanical \/ 10,000 electrical operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree-phase sub-main feeder protection\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial DB incoming protection\u003c\/li\u003e\n\u003cli\u003eHigh-current circuit MCCB protection\u003c\/li\u003e\n\u003cli\u003eBuilding services main distribution protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) like the HHA100Z is built for higher currents and fault levels — up to 25kA breaking capacity here — and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board, rather than on individual final circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThe HHA100Z is a 3-pole device for three-phase circuits without a switched neutral, suited to three-phase feeders and main incomers on a 3-wire supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163350495331,"sku":"HA100Z","price":180.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/HHA100Z.webp?v=1786965636"},{"product_id":"hager-ha125z-3-pole-125a-mccb","title":"Hager MCCB 3-Pole 125A HHA125Z","description":"\u003ch2\u003eHager HA125Z 3-Pole 125A MCCB\u003c\/h2\u003e\n\u003cp\u003eThe Hager HA125Z is a 3-pole 125A MCCB for main incoming and sub-main feeder protection in UAE commercial and industrial distribution switchgear and distribution boards.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3-pole 125A MCCB for high-current incoming and feeder protection\u003c\/li\u003e\n\u003cli\u003eFixed front mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MCCB quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHHA125Z\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain incoming protection in commercial switchgear\u003c\/li\u003e\n\u003cli\u003eThree-phase sub-main feeder MCCB\u003c\/li\u003e\n\u003cli\u003eIndustrial panel incoming protection\u003c\/li\u003e\n\u003cli\u003eLarge building services main distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCCB and an MCB?\u003c\/strong\u003e\u003cbr\u003eMCCBs (moulded case circuit breakers) handle higher current ratings than standard MCBs and are typically used as main incomers or sub-main protection in distribution boards, rather than on individual final circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole, 125A unit, sized for a three-phase supply or sub-main.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — an MCCB of this rating is installed as part of a distribution board's main protection and must be fitted and commissioned by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere is this typically used?\u003c\/strong\u003e\u003cbr\u003eAs the main incomer or sub-main breaker in commercial, industrial, or larger residential distribution boards, protecting the downstream final-circuit MCBs and RCCBs.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163350528099,"sku":"HHA125Z","price":225.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/HHA125Z.webp?v=1786965639"},{"product_id":"hager-hha063z-3-pole-63a-mccb","title":"Hager MCCB 3-Pole 63A HHA063Z","description":"\u003ch2\u003eHager HHA063Z 3-Pole 63A MCCB\u003c\/h2\u003e\u003cp\u003eThe Hager HHA063Z is a 3-pole 63A MCCB for sub-main feeder and incoming circuit protection in UAE commercial and industrial distribution boards, providing reliable protection for higher-current three-phase circuits.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pole 63A MCCB for three-phase circuit protection\u003c\/li\u003e\n\u003cli\u003eFixed front mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MCCB quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHHA063Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThree-phase sub-main and incoming circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial DB MCCB protection\u003c\/li\u003e\n\u003cli\u003eMotor feeder and power circuit protection\u003c\/li\u003e\n\u003cli\u003eBuilding services main distribution protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCCB and an MCB?\u003c\/strong\u003e\u003cbr\u003eMCCBs (moulded case circuit breakers) handle higher current ratings than standard MCBs and are typically used as main incomers or sub-main protection in distribution boards, rather than on individual final circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole, 63A unit, sized for a three-phase supply or sub-main.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — an MCCB of this rating is installed as part of a distribution board's main protection and must be fitted and commissioned by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere is this typically used?\u003c\/strong\u003e\u003cbr\u003eAs the main incomer or sub-main breaker in commercial, industrial, or larger residential distribution boards, protecting the downstream final-circuit MCBs and RCCBs.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163350560867,"sku":"HHA063Z","price":190.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/HHA063Z.webp?v=1786965641"},{"product_id":"abb-a1n-125-tmf80-3-pole-80a-mccb","title":"ABB MCCB A1N 125 TMF 80-800 3p F F 1SDA066729R1","description":"\u003ch2\u003eABB A1N 125 TMF80 3-Pole Moulded Case Circuit Breaker\u003c\/h2\u003e\n\u003cp\u003eThe A1N 125 TMF 80-800 is a fixed three-pole moulded case circuit breaker from ABB's SACE Formula range, rated at 80A with a thermomagnetic (TMF) release and front terminal connections. Designed for protection of feeders, distribution circuits, and machinery, it offers reliable overload and short-circuit protection suited to commercial and industrial installations across the UAE.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3-pole moulded case circuit breaker with 80A rated current and 125A frame (Iu) rating\u003c\/li\u003e\n  \u003cli\u003eTMF thermomagnetic release providing combined overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003e36kA rated ultimate breaking capacity (Icu) at 415V for robust fault-condition performance\u003c\/li\u003e\n  \u003cli\u003eFront terminal connections for straightforward panel installation and wiring access\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB quality — 8,500 mechanical operating cycles for long-term reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA1N 125 TMF 80-800 3P F F\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Uninterrupted Current (Iu)\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRelease Type\u003c\/td\u003e\n\u003ctd\u003eTMF (Thermomagnetic, fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e550V AC \/ 250V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e690V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Ultimate Breaking Capacity (Icu) at 415V\u003c\/td\u003e\n\u003ctd\u003e36kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Service Breaking Capacity (Ics) at 415V\u003c\/td\u003e\n\u003ctd\u003e7.5kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTerminal Connection Type\u003c\/td\u003e\n\u003ctd\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMechanical Durability\u003c\/td\u003e\n\u003ctd\u003e8,500 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eElectrical Durability\u003c\/td\u003e\n\u003ctd\u003e1,500 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.798 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e76.2 x 130 x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFeeder and distribution circuit protection in commercial and industrial panels\u003c\/li\u003e\n  \u003cli\u003eMotor and machinery circuit protection requiring combined overload and short-circuit trip\u003c\/li\u003e\n  \u003cli\u003eMain or sub-main protection in low voltage distribution boards\u003c\/li\u003e\n  \u003cli\u003ePanel builds across the UAE requiring compact, front-terminal MCCB protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44344461394019,"sku":"1SDA066729R1","price":183.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000045322_400x400_3.jpg?v=1787498343"},{"product_id":"abb-a1c-125-tmf63-3-pole-63a-mccb","title":"ABB MCCB TP 63A 25KA A1C 125R63-68770R1 Formula","description":"\u003ch2\u003eABB A1C 125 TMF63 3-Pole Moulded Case Circuit Breaker\u003c\/h2\u003e\n\u003cp\u003eThe A1C 125 TMF 63-630 is a fixed three-pole moulded case circuit breaker from ABB's SACE Formula range, rated at 63A with a thermomagnetic (TMF) release and front terminal connections. Designed for protection of feeders, distribution circuits, and machinery, it offers reliable overload and short-circuit protection suited to commercial and industrial installations across the UAE.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3-pole moulded case circuit breaker with 63A rated current and 125A frame (Iu) rating\u003c\/li\u003e\n  \u003cli\u003eTMF thermomagnetic release providing combined overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003e25kA rated ultimate breaking capacity (Icu) at 415V, suited to standard commercial fault levels\u003c\/li\u003e\n  \u003cli\u003eFront terminal connections for straightforward panel installation and wiring access\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB quality — 8,500 mechanical operating cycles for long-term reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA1C 125 TMF 63-630 3P F F\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Uninterrupted Current (Iu)\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRelease Type\u003c\/td\u003e\n\u003ctd\u003eTMF (Thermomagnetic, fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e550V AC \/ 250V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e690V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Ultimate Breaking Capacity (Icu) at 415V\u003c\/td\u003e\n\u003ctd\u003e25kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Service Breaking Capacity (Ics) at 415V\u003c\/td\u003e\n\u003ctd\u003e6.25kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eShort-Circuit Performance Level\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTerminal Connection Type\u003c\/td\u003e\n\u003ctd\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMechanical Durability\u003c\/td\u003e\n\u003ctd\u003e8,500 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eElectrical Durability\u003c\/td\u003e\n\u003ctd\u003e1,500 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.79 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e76.2 x 130 x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFeeder and distribution circuit protection in commercial and light industrial panels\u003c\/li\u003e\n  \u003cli\u003eMotor and machinery circuit protection requiring combined overload and short-circuit trip\u003c\/li\u003e\n  \u003cli\u003eMain or sub-main protection in low voltage distribution boards\u003c\/li\u003e\n  \u003cli\u003ePanel builds across the UAE requiring compact, front-terminal MCCB protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44344501207139,"sku":"1SDA068770R1","price":285.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000045322_400x400_4.jpg?v=1787498345"},{"product_id":"abb-a1c-125-tmf100-3-pole-100a-mccb","title":"ABB A1C 125 TMF 100-1000 3p F F C.Breaker Formula 1C 125 Fixed Three-Pole With Front Terminals and Thermomagnetic Release TMF R 100-1000 A","description":"\u003ch2\u003eABB A1C 125 TMF100 3-Pole Moulded Case Circuit Breaker\u003c\/h2\u003e\n\u003cp\u003eThe A1C 125 TMF 100-1000 is a fixed three-pole moulded case circuit breaker from ABB's SACE Formula range, rated at 100A with a thermomagnetic (TMF) release and front terminal connections. Designed for protection of feeders, distribution circuits, and machinery, it offers reliable overload and short-circuit protection suited to commercial and industrial installations across the UAE.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3-pole moulded case circuit breaker with 100A rated current and 125A frame (Iu) rating\u003c\/li\u003e\n  \u003cli\u003eTMF thermomagnetic release providing combined overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003e25kA rated ultimate breaking capacity (Icu) at 415V, suited to standard commercial fault levels\u003c\/li\u003e\n  \u003cli\u003eFront terminal connections for straightforward panel installation and wiring access\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB quality — 8,500 mechanical operating cycles for long-term reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA1C 125 TMF 100-1000 3P F F\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Uninterrupted Current (Iu)\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRelease Type\u003c\/td\u003e\n\u003ctd\u003eTMF (Thermomagnetic, fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e550V AC \/ 250V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e690V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Ultimate Breaking Capacity (Icu) at 415V\u003c\/td\u003e\n\u003ctd\u003e25kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Service Breaking Capacity (Ics) at 415V\u003c\/td\u003e\n\u003ctd\u003e6.25kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eShort-Circuit Performance Level\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTerminal Connection Type\u003c\/td\u003e\n\u003ctd\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMechanical Durability\u003c\/td\u003e\n\u003ctd\u003e8,500 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eElectrical Durability\u003c\/td\u003e\n\u003ctd\u003e1,500 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.79 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e76.2 x 130 x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFeeder and distribution circuit protection in commercial and light industrial panels\u003c\/li\u003e\n  \u003cli\u003eMotor and machinery circuit protection requiring combined overload and short-circuit trip\u003c\/li\u003e\n  \u003cli\u003eMain or sub-main protection in low voltage distribution boards\u003c\/li\u003e\n  \u003cli\u003ePanel builds across the UAE requiring compact, front-terminal MCCB protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44344568840291,"sku":"1SDA066719R1","price":183.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000045322_400x400_dfc1faad-5286-42cd-ab95-85e613e6eafa.jpg?v=1787498348"},{"product_id":"abb-a1c-125-tmf32-400-3p-32a-mccb","title":"ABB A1C 125 TMF 32-400 3p F F 1SDA068759R1","description":"\u003ch2\u003eABB A1C 125 TMF 32-400 3-Pole MCCB\u003c\/h2\u003e\n\u003cp\u003eThe ABB A1C 125 TMF 32-400 is a fixed three-pole moulded case circuit breaker from the ABB Formula series, rated at 32A with a thermomagnetic (TMF) release for fixed thermal and magnetic protection settings. Built for reliable overload and short-circuit protection in distribution boards and panels, it suits the demanding electrical loads found in UAE commercial and industrial installations.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3-pole 32A moulded case circuit breaker with fixed thermomagnetic (TMF) release for dependable overload and short-circuit protection.\u003c\/li\u003e\n  \u003cli\u003e25kA ultimate breaking capacity (Icu) and 6.25kA service breaking capacity (Ics) at 415V AC, suited to typical UAE distribution board fault levels.\u003c\/li\u003e\n  \u003cli\u003eFront terminal connection for straightforward installation and wiring access in panel builds.\u003c\/li\u003e\n  \u003cli\u003eCompact Formula DSA frame footprint (76.2 x 130 x 60mm) for space-efficient panel layouts.\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB quality — manufacturer tested and rated for 8,500 mechanical operating cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA1C 125 TMF 32-400 3p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eSACE Formula\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Uninterrupted Current (Iu)\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRelease Type\u003c\/td\u003e\n\u003ctd\u003eTMF (Thermomagnetic, Fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eShort-Circuit Performance Level\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e550V AC \/ 250V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e690V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity Icu (415V AC)\u003c\/td\u003e\n\u003ctd\u003e25kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity Ics (415V AC)\u003c\/td\u003e\n\u003ctd\u003e6.25kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMechanical Durability\u003c\/td\u003e\n\u003ctd\u003e8,500 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eElectrical Durability\u003c\/td\u003e\n\u003ctd\u003e1,500 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e76.2 x 130 x 60mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.787kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain and sub-main protection in low-voltage distribution boards for commercial buildings\u003c\/li\u003e\n  \u003cli\u003eMotor and feeder circuit protection in industrial panels and switchrooms\u003c\/li\u003e\n  \u003cli\u003eIncoming or outgoing circuit protection for HVAC and mechanical plant rooms\u003c\/li\u003e\n  \u003cli\u003eDistribution board upgrades and MCCB replacements in UAE retrofit projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44344575066211,"sku":"1SDA068759R1","price":183.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000045321_400x400_1.jpg?v=1787498350"},{"product_id":"abb-a1n-125-tmf63-630-3p-63a-mccb","title":"ABB A1N 125 TMF 63-630 3p F F 1SDA068771R1","description":"\u003ch2\u003eABB A1N 125 TMF 63-630 3-Pole MCCB\u003c\/h2\u003e\n\u003cp\u003eThe ABB A1N 125 TMF 63-630 is a fixed three-pole moulded case circuit breaker from the ABB Formula series, rated at 63A with a thermomagnetic (TMF) release for fixed thermal and magnetic protection settings. Its N-rated short-circuit performance delivers higher fault-current handling than standard C-rated variants, making it well suited to demanding UAE commercial and industrial panels.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3-pole 63A moulded case circuit breaker with fixed thermomagnetic (TMF) release for dependable overload and short-circuit protection.\u003c\/li\u003e\n  \u003cli\u003e36kA ultimate breaking capacity (Icu) and 7.5kA service breaking capacity (Ics) at 415V AC, giving strong fault-level headroom for UAE distribution panels.\u003c\/li\u003e\n  \u003cli\u003eN short-circuit performance level for higher-duty applications than standard C-rated breakers.\u003c\/li\u003e\n  \u003cli\u003eFront terminal connection for straightforward installation and wiring access in panel builds.\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB quality — manufacturer tested and rated for 8,500 mechanical operating cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA1N 125 TMF 63-630 3p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eSACE Formula\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Uninterrupted Current (Iu)\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRelease Type\u003c\/td\u003e\n\u003ctd\u003eTMF (Thermomagnetic, Fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eShort-Circuit Performance Level\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e550V AC \/ 250V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e690V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity Icu (415V AC)\u003c\/td\u003e\n\u003ctd\u003e36kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity Ics (415V AC)\u003c\/td\u003e\n\u003ctd\u003e7.5kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMechanical Durability\u003c\/td\u003e\n\u003ctd\u003e8,500 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eElectrical Durability\u003c\/td\u003e\n\u003ctd\u003e1,500 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e76.2 x 130 x 60mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.75kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain and sub-main protection in higher fault-level distribution boards for commercial buildings\u003c\/li\u003e\n  \u003cli\u003eMotor and feeder circuit protection in industrial panels and switchrooms\u003c\/li\u003e\n  \u003cli\u003eIncoming or outgoing circuit protection for HVAC and mechanical plant rooms\u003c\/li\u003e\n  \u003cli\u003eDistribution board upgrades and MCCB replacements in UAE retrofit projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44344577622115,"sku":"1SDA068771R1","price":183.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000045321_400x400_2.jpg?v=1787498350"},{"product_id":"abb-a2n-250-tmf125-1250-3p-125a-mccb","title":"ABB A2N 250 TMF 125-1250 3p F F 1SDA066781R1","description":"\u003ch2\u003eABB A2N 250 TMF 125-1250 3-Pole MCCB\u003c\/h2\u003e\n\u003cp\u003eThe ABB A2N 250 TMF 125-1250 is a fixed three-pole moulded case circuit breaker from the ABB Formula series, rated at 125A with a thermomagnetic (TMF) release for fixed thermal and magnetic protection settings. Its higher frame rating and N-rated short-circuit performance make it suited to main incomer and heavy feeder protection in UAE commercial and industrial distribution boards.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3-pole 125A moulded case circuit breaker with fixed thermomagnetic (TMF) release for dependable overload and short-circuit protection.\u003c\/li\u003e\n  \u003cli\u003e36kA ultimate breaking capacity (Icu) and 18kA service breaking capacity (Ics) at 415V AC, providing strong fault-level headroom for larger UAE distribution panels.\u003c\/li\u003e\n  \u003cli\u003eN short-circuit performance level suited to higher-duty and main incomer applications.\u003c\/li\u003e\n  \u003cli\u003eFront terminal connection for straightforward installation and wiring access in panel builds.\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB quality — manufacturer tested and rated for 10,000 mechanical operating cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA2N 250 TMF 125-1250 3p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eSACE Formula\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Uninterrupted Current (Iu)\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRelease Type\u003c\/td\u003e\n\u003ctd\u003eTMF (Thermomagnetic, Fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eShort-Circuit Performance Level\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e550V AC \/ 250V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e690V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity Icu (415V AC)\u003c\/td\u003e\n\u003ctd\u003e36kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity Ics (415V AC)\u003c\/td\u003e\n\u003ctd\u003e18kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMechanical Durability\u003c\/td\u003e\n\u003ctd\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eElectrical Durability\u003c\/td\u003e\n\u003ctd\u003e4,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e105 x 150 x 60mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.391kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain incomer protection in low-voltage distribution boards for commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eHeavy feeder and transformer secondary protection in switchrooms and panel builds\u003c\/li\u003e\n  \u003cli\u003eMotor control centre and generator protection applications\u003c\/li\u003e\n  \u003cli\u003eDistribution board upgrades and MCCB replacements in UAE retrofit projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44344579227747,"sku":"1SDA066781R1","price":472.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000045327_400x400_2068ba75-d8b0-49e7-a2e5-be13706b8dae.jpg?v=1787498351"},{"product_id":"abb-a2n-250-tmf200-2000-3p-200a-mccb","title":"ABB A2N 250 TMF 200-2000 3p F F 1SDA066784R1","description":"\u003ch2\u003eABB A2N 250 TMF 200-2000 3-Pole MCCB\u003c\/h2\u003e\n\u003cp\u003eThe ABB A2N 250 TMF 200-2000 is a fixed three-pole moulded case circuit breaker from the ABB Formula series, rated at 200A with a thermomagnetic (TMF) release for fixed thermal and magnetic protection settings. Its high current rating and N-rated short-circuit performance make it well suited to main incomer and large feeder protection in UAE commercial and industrial distribution boards.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3-pole 200A moulded case circuit breaker with fixed thermomagnetic (TMF) release for dependable overload and short-circuit protection.\u003c\/li\u003e\n  \u003cli\u003e36kA ultimate breaking capacity (Icu) and 18kA service breaking capacity (Ics) at 415V AC, providing strong fault-level headroom for high-current UAE distribution panels.\u003c\/li\u003e\n  \u003cli\u003eN short-circuit performance level suited to higher-duty and main incomer applications.\u003c\/li\u003e\n  \u003cli\u003eFront terminal connection for straightforward installation and wiring access in panel builds.\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB quality — manufacturer tested and rated for 10,000 mechanical operating cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA2N 250 TMF 200-2000 3p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eSACE Formula\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Uninterrupted Current (Iu)\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRelease Type\u003c\/td\u003e\n\u003ctd\u003eTMF (Thermomagnetic, Fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eShort-Circuit Performance Level\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e550V AC \/ 250V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e690V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity Icu (415V AC)\u003c\/td\u003e\n\u003ctd\u003e36kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity Ics (415V AC)\u003c\/td\u003e\n\u003ctd\u003e18kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMechanical Durability\u003c\/td\u003e\n\u003ctd\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eElectrical Durability\u003c\/td\u003e\n\u003ctd\u003e4,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e105 x 150 x 60mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.396kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain incomer protection in large low-voltage distribution boards for commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eTransformer secondary and large feeder protection in switchrooms and panel builds\u003c\/li\u003e\n  \u003cli\u003eGenerator and motor control centre protection applications\u003c\/li\u003e\n  \u003cli\u003eDistribution board upgrades and MCCB replacements in UAE retrofit projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44344580604003,"sku":"1SDA066784R1","price":619.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000045328_400x400_1.jpg?v=1787498353"},{"product_id":"abb-a3n-400-tmf400-4000-3p-400a-mccb-50c","title":"ABB A3N 400 TMF 400-4000 3p F F 50°C 1SDA068810R1","description":"\u003ch2\u003eABB A3N 400 TMF 400-4000 3-Pole MCCB (50°C Rated)\u003c\/h2\u003e\n\u003cp\u003eThe ABB A3N 400 TMF 400-4000 is a fixed three-pole moulded case circuit breaker from the ABB Formula series, rated at 400A with a thermomagnetic (TMF) release and certified for continuous operation at 50°C ambient temperature. This higher ambient rating makes it particularly well suited to UAE plant rooms, rooftop switchrooms, and outdoor enclosures where sustained heat and dust are common operating conditions.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3-pole 400A moulded case circuit breaker with fixed thermomagnetic (TMF) release for dependable overload and short-circuit protection.\u003c\/li\u003e\n  \u003cli\u003eRated for continuous operation at 50°C ambient, suited to high-temperature UAE plant rooms and unconditioned switchrooms.\u003c\/li\u003e\n  \u003cli\u003e36kA ultimate breaking capacity (Icu) and 18kA service breaking capacity (Ics) at 415V AC for demanding fault-level applications.\u003c\/li\u003e\n  \u003cli\u003eN short-circuit performance level suited to main incomer and heavy industrial duty.\u003c\/li\u003e\n  \u003cli\u003eFront terminal connection for straightforward installation and wiring access in panel builds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA3N 400 TMF 400-4000 3p F F 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eSACE Formula\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Uninterrupted Current (Iu)\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Rating\u003c\/td\u003e\n\u003ctd\u003e50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRelease Type\u003c\/td\u003e\n\u003ctd\u003eTMF (Thermomagnetic, Fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eShort-Circuit Performance Level\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e550V AC \/ 250V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e690V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity Icu (415V AC)\u003c\/td\u003e\n\u003ctd\u003e36kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity Ics (415V AC)\u003c\/td\u003e\n\u003ctd\u003e18kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMechanical Durability\u003c\/td\u003e\n\u003ctd\u003e5,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eElectrical Durability\u003c\/td\u003e\n\u003ctd\u003e2,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e139.5 x 205 x 103.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.75kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain incomer protection in UAE plant rooms and rooftop switchrooms exposed to high ambient heat\u003c\/li\u003e\n  \u003cli\u003eLarge feeder and transformer secondary protection in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eGenerator and motor control centre protection in unconditioned or semi-outdoor enclosures\u003c\/li\u003e\n  \u003cli\u003eDistribution board upgrades and MCCB replacements where sustained high-temperature operation is a factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44344584634467,"sku":"1SDA068810R1","price":1050.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000045332_400x400_809b34cd-eefc-40bd-b464-0918bb2bd4ac.jpg?v=1787498354"},{"product_id":"abb-sh201-c32-1-pole-32a-6ka-type-c-mcb","title":"ABB MCB 32A Single Pole SH201-C32","description":"\u003ch2\u003eABB SH201-C32 1-Pole 32A 6kA Type C MCB\u003c\/h2\u003e\n\u003cp\u003eThe ABB SH201-C32 is a 1-pole, 32A Type C miniature circuit breaker with 6kA breaking capacity from the ABB Compact Home SH200 series. Combining a delayed thermal tripping mechanism for overload protection with an electromechanical mechanism for short circuit protection, it is current limiting and designed specifically for residential distribution board applications, making it a cost-effective choice for villa and apartment installations across the UAE.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1-pole 32A Type C MCB for single-phase circuit protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003e6kA breaking capacity suitable for standard UAE residential fault levels\u003c\/li\u003e\n  \u003cli\u003eType C tripping characteristic suitable for resistive and lightly inductive household loads\u003c\/li\u003e\n  \u003cli\u003eCompact 17.5 mm width (1 modular spacing) for space-efficient DIN rail installation\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB SH200 series quality — consistent performance and reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSH201-C32\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Short-Circuit Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail (TH35-15 \/ TH35-7.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals (Cage Terminal)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (IP40 with enclosure\/cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMechanical Endurance\u003c\/td\u003e\n\u003ctd\u003e20,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSingle-phase lighting and power circuit protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eVilla and apartment consumer unit circuit protection across the UAE\u003c\/li\u003e\n  \u003cli\u003eCost-effective MCB replacement for residential installations\u003c\/li\u003e\n  \u003cli\u003eGeneral household circuit protection where compact, reliable overcurrent protection is needed\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44346836222051,"sku":"ABBMCB32ASP","price":14.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000150977_400x400_9437d2bb-b17b-4bd3-a4bb-cd71ceca0725.jpg?v=1787498359"},{"product_id":"abb-s201-c16-1-pole-16a-6ka-type-c-mcb","title":"ABB MCB S201 - 1P - 16A 10kA S201-C16","description":"\u003ch2\u003eABB S201-C16 1-Pole 16A 6kA Type C MCB\u003c\/h2\u003e\n\u003cp\u003eThe ABB S201-C16 is a 1-pole 16A Type C miniature circuit breaker with 6kA breaking capacity from the ABB S200 series. Designed for protection of single-phase circuits in residential and commercial distribution boards, it is one of the most widely used MCBs in UAE building installations for lighting and power circuit protection.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1-pole 16A Type C MCB for single-phase lighting and power circuit protection\u003c\/li\u003e\n  \u003cli\u003e6kA breaking capacity for standard UAE residential and commercial installation fault levels\u003c\/li\u003e\n  \u003cli\u003eType C tripping characteristic suitable for resistive and lightly inductive loads\u003c\/li\u003e\n  \u003cli\u003eCompact DIN rail mounting for distribution board installation\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB S200 series quality — consistent performance and reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS201-C16\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Short-Circuit Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA (AC\/DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Ultimate Breaking Capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e20kA (133V AC) \/ 10kA (230V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail (TH35-15 \/ TH35-7.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (IP40 with enclosure\/cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMechanical Endurance\u003c\/td\u003e\n\u003ctd\u003e20,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.115 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSingle-phase lighting circuit protection in residential DBs\u003c\/li\u003e\n  \u003cli\u003ePower and socket circuit protection in commercial distribution boards\u003c\/li\u003e\n  \u003cli\u003eGeneral building services circuit protection in UAE installations\u003c\/li\u003e\n  \u003cli\u003eConsumer unit and distribution board MCB replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 1-pole device, sized for the corresponding single or three-phase supply arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44346849558627,"sku":"2CDS251001R0164","price":27.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000002880_400x400_f6d51b96-d2e8-4275-863b-c2dbdbe66f52.png?v=1787498877"},{"product_id":"abb-xt3n-250-tmd-250-2500-3-pole-mccb-fixed","title":"ABB MCCB XT3N 250 TMD 200-2000 3p FF","description":"\u003ch2\u003eABB Tmax XT3N 250 3-Pole Moulded Case Circuit Breaker\u003c\/h2\u003e\n\u003cp\u003eThe XT3N 250 TMD is a fixed, three-pole moulded case circuit breaker from ABB's Tmax XT range, fitted with front terminals and a TMD thermomagnetic release offering an adjustable current setting range of 175-250A. Rated at 690V AC with a short-circuit performance level N, it provides robust protection for main distribution and sub-main applications in commercial and industrial UAE facilities, backed by a wide range of ABB accessories for customisation.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3-pole fixed MCCB rated at 250A with adjustable TMD thermomagnetic release (175-250A setting range)\u003c\/li\u003e\n  \u003cli\u003eRated ultimate breaking capacity (Icu) of 36kA at 380-440V AC, suitable for demanding commercial and industrial fault levels\u003c\/li\u003e\n  \u003cli\u003eFront terminal bolt-type connections rated for busbar cross-sections of 85-192 mm²\u003c\/li\u003e\n  \u003cli\u003eHigh mechanical durability of 25,000 cycles and electrical durability of 8,000 cycles for long service life\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eXT3N 250 TMD 250-2500 3p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSetting Range (Thermomagnetic)\u003c\/td\u003e\n\u003ctd\u003e175-250A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRelease Type\u003c\/td\u003e\n\u003ctd\u003eTMD (Thermomagnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Instantaneous Short-Circuit Setting (Ii)\u003c\/td\u003e\n\u003ctd\u003e2500A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e690V AC \/ 500V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e800V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Ultimate Breaking Capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e50kA (220-240V) \/ 36kA (380-440V) \/ 5kA (690V)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTerminal Connection Type\u003c\/td\u003e\n\u003ctd\u003eFront, Bolt Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCurrent Type\u003c\/td\u003e\n\u003ctd\u003eAC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain and sub-main distribution board protection in commercial and industrial UAE buildings\u003c\/li\u003e\n  \u003cli\u003eTransformer and generator protection requiring adjustable thermomagnetic settings\u003c\/li\u003e\n  \u003cli\u003ePower distribution circuit protection in panel builder switchboard assemblies\u003c\/li\u003e\n  \u003cli\u003eMotor and feeder circuit protection where a compact, fixed 250A MCCB is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44346921517155,"sku":"1SDA068058R1","price":759.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9IBA255129_400x400_37ff7a0c-228a-4384-a57c-808ee7eb6678.png?v=1787498883"},{"product_id":"abb-xt3n-250-tmd-3-pole-250a-36ka-mccb","title":"ABB MCCB XT3N 250 TMD 250-2500 3p F F","description":"\u003ch2\u003eABB XT3N 250 TMD 3-Pole 250A Moulded Case Circuit Breaker\u003c\/h2\u003e\n\u003cp\u003eThe ABB XT3N 250 TMD is a fixed three-pole moulded case circuit breaker from the SACE Tmax XT series, fitted with front terminals and a thermomagnetic (TMD) release adjustable across 175-250A. Rated for 690V AC operation with a 36kA breaking capacity at 415V, it is well suited for main and distribution protection duties in UAE commercial and industrial low voltage panels.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAdjustable thermomagnetic TMD release with rated current setting range of 175-250A for flexible protection coordination\u003c\/li\u003e\n  \u003cli\u003eRated ultimate short-circuit breaking capacity (Icu) of 36kA at 415V AC and 50kA at 220-240V AC, suitable for high fault-level UAE installations\u003c\/li\u003e\n  \u003cli\u003eFront terminal bolt connection with fixed mounting, designed for compact panel and switchboard installation\u003c\/li\u003e\n  \u003cli\u003eAC\/DC current type rated up to 690V AC or 500V DC, supporting a wide range of distribution and industrial applications\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB quality — manufactured to IEC 60947-2 standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eXT3N 250 TMD 250-2500 3p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSetting Range\u003c\/td\u003e\n\u003ctd\u003e175-250A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRelease Type\u003c\/td\u003e\n\u003ctd\u003eTMD (Thermomagnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Instantaneous Short-Circuit Setting (Ii)\u003c\/td\u003e\n\u003ctd\u003e2500A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Icu at 415V AC)\u003c\/td\u003e\n\u003ctd\u003e36kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Icu at 690V AC)\u003c\/td\u003e\n\u003ctd\u003e5kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e690V AC \/ 500V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e800V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd\u003eFront, Bolt type\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain incomer protection in low voltage distribution boards for commercial buildings\u003c\/li\u003e\n  \u003cli\u003eFeeder and sub-distribution protection in industrial panels and switchboards\u003c\/li\u003e\n  \u003cli\u003eMotor and installation protection in facilities with high fault-current levels\u003c\/li\u003e\n  \u003cli\u003ePanel builder projects requiring adjustable thermomagnetic protection settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44346934591587,"sku":"1SDA068059R1","price":759.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9IBA255129_400x400_1.png?v=1787498883"},{"product_id":"abb-fa4n-2500-3-pole-air-circuit-breaker","title":"ABB ACB FA4N 2500 3p WMP + Ek 1 LI FA\/HF2 1SDX012133R1","description":"\u003ch2\u003eABB FA4N 2500 3-Pole Air Circuit Breaker\u003c\/h2\u003e\n\u003cp\u003eThe FA4N 2500 is a three-pole air circuit breaker from ABB's Formula Air range, supplied complete with an electronic release accessory module. Designed for main protection and switching duties in low voltage switchboards, it is suited to large commercial and industrial power distribution applications across the UAE.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3-pole air circuit breaker from ABB's Formula Air (FA4N) range\u003c\/li\u003e\n  \u003cli\u003eSupplied with electronic release accessory module for advanced protection functions\u003c\/li\u003e\n  \u003cli\u003eDesigned for main switchboard protection and switching applications\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB quality — manufactured in Italy\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFA4N 2500 3p WMP + Acc\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eFormula Air\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eItaly\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNote\u003c\/td\u003e\n\u003ctd\u003eFull electrical ratings (rated current, breaking capacity, voltage) to be confirmed from full technical datasheet before publishing\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain incomer protection and switching in large low voltage switchboards\u003c\/li\u003e\n  \u003cli\u003eBus-tie and generator breaker applications in commercial and industrial power distribution\u003c\/li\u003e\n  \u003cli\u003eCritical infrastructure requiring high-capacity air circuit breaker protection across the UAE\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44352327188579,"sku":"1SDX012133R1","price":15687.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9IBA202006_400x400_3ef7659c-172f-49e7-893e-87cbc71b5c36.jpg?v=1787498362"},{"product_id":"abb-a2n-250-tmf-160a-3p-mccb","title":"ABB C.Breaker Formula A2N 250 Fixed Three-Pole With Front Terminals And Thermomagnetic Release TMF R 160-1600A A2N 250 TMF 160-1600 3p F F","description":"\u003ch2\u003eABB A2N 250 TMF 160A 3-Pole Moulded Case Circuit Breaker\u003c\/h2\u003e\n\u003cp\u003eThe A2N 250 TMF is a fixed 3-pole moulded case circuit breaker (MCCB) from ABB's SACE Formula range, rated at 160A with a thermomagnetic (TMF) release adjustable across the 160-1600A band. Fitted with front terminals, it is built for protection of feeders and main circuits in commercial and industrial distribution boards, including panel builds and switchroom upgrades across the UAE.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3-pole fixed MCCB with 160A rated current (250A frame) for main and feeder circuit protection\u003c\/li\u003e\n  \u003cli\u003eTMF thermomagnetic release provides combined overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eHigh breaking capacity of up to 36kA (Icu) at 415V AC, suitable for demanding fault levels\u003c\/li\u003e\n  \u003cli\u003eFront terminal connection for straightforward installation and maintenance access in panels\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB Formula quality — rated for 10,000 mechanical and 4,000 electrical operating cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA2N 250 TMF 160-1600 3p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eMoulded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e160A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Uninterrupted Current (Iu)\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRelease Type\u003c\/td\u003e\n\u003ctd\u003eTMF (Thermomagnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e550V AC \/ 250V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e690V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Icu) at 415V AC\u003c\/td\u003e\n\u003ctd\u003e36kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Ics) at 415V AC\u003c\/td\u003e\n\u003ctd\u003e18kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain incomer or feeder protection in commercial and industrial distribution boards\u003c\/li\u003e\n  \u003cli\u003eProtection of HVAC plant and large motor circuits in UAE commercial buildings\u003c\/li\u003e\n  \u003cli\u003eSub-main protection in panel builder assemblies and switchroom upgrades\u003c\/li\u003e\n  \u003cli\u003eCircuit protection in industrial facilities and MEP contractor installations across the UAE\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this MCCB have an adjustable trip setting?\u003c\/strong\u003e\u003cbr\u003eCheck the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44352399704163,"sku":"1SDA066782R1","price":435.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000045328_400x400_2.jpg?v=1787498363"}],"url":"https:\/\/www.deluxeuae.com\/collections\/mccbs.oembed","provider":"Deluxe Electricals","version":"1.0","type":"link"}