{"title":"MCBs","description":"\u003cp\u003eShop miniature circuit breakers for distribution boards across the UAE — ABB, Hager and Schneider Electric MCBs for villas, apartments, offices and light commercial work. An MCB is the device in your DB that trips to protect a circuit from overload and short circuit.\u003c\/p\u003e\u003ch2\u003eWhat ampere rating do I need?\u003c\/h2\u003e\u003cp\u003eThe rating follows the circuit, not the appliance. Lighting circuits are typically 6A or 10A; general socket circuits 16A to 20A; a water heater or cooker circuit higher again. If you are replacing a breaker that works, match the existing label exactly — rating, type and pole count. Fitting a larger breaker to stop nuisance tripping is dangerous: the breaker protects the cable, and a higher rating lets the cable overheat before it trips.\u003c\/p\u003e\u003ch2\u003eType B, C or D?\u003c\/h2\u003e\u003cp\u003eThe letter is the magnetic trip curve — how quickly the breaker reacts to a surge. \u003cstrong\u003eType B\u003c\/strong\u003e trips fastest and suits resistive domestic loads such as lighting and sockets. \u003cstrong\u003eType C\u003c\/strong\u003e tolerates the inrush of motors, transformers and fluorescent banks, which is why it is common in commercial boards. \u003cstrong\u003eType D\u003c\/strong\u003e allows the highest inrush, for welders and large motors.\u003c\/p\u003e\u003ch2\u003ePoles and breaking capacity\u003c\/h2\u003e\u003cp\u003eSingle pole for single-phase circuits, two pole where the neutral must also be broken, three or four pole for three-phase. Breaking capacity, quoted in kA, is the largest fault current the device can safely interrupt — it must suit the prospective fault level at the board.\u003c\/p\u003e\u003cp\u003eSelection and replacement should be confirmed by a licensed electrician against the actual circuit and board. Send us your DB schedule and we will quote against it.\u003c\/p\u003e","products":[{"product_id":"hager-miniature-circuit-breaker-1p-made-in-france","title":"Hager MCB 1-Pole 6kA Type C Range — Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager MCB 1-Pole 6kA Type C Range — Made in France\u003c\/h2\u003e\n\u003cp\u003eThe Hager 1-Pole MCB range delivers dependable overcurrent protection for 230V circuits, Made in France and available across the full 6A-63A rating band from a single Hager product family (MCN106, MCN110A, MCN116, MCN120, MCN125, MCN132, MCN140, MCN150, MCN163). With a 6kA breaking capacity and Type C tripping curve, it suits residential consumer units and commercial distribution boards where a compact, single-module DIN-rail breaker is needed for lighting, socket, and general power circuits.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e9 current ratings in one range: 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A\u003c\/li\u003e\n\u003cli\u003e1-pole (1P), single-module (17.5mm) construction across every rating in the range\u003c\/li\u003e\n\u003cli\u003e6kA rated breaking capacity (Icn) to IEC 60898-1\u003c\/li\u003e\n\u003cli\u003eType C tripping curve — suited to circuits with moderate inrush current\u003c\/li\u003e\n\u003cli\u003eRated operating voltage 240-415V AC, 50-60Hz\u003c\/li\u003e\n\u003cli\u003eIP20 enclosure rating with -25°C to +70°C operating range\u003c\/li\u003e\n\u003cli\u003eScrew-terminal DIN-rail mounting (EN 60715) for fast panel installation\u003c\/li\u003e\n\u003cli\u003eMade in France to Hager's standard build quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eMCN1 Series — 1-Pole 6kA Type C MCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1 (Single Pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Ratings\u003c\/td\u003e\n\u003ctd\u003e6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Icn)\u003c\/td\u003e\n\u003ctd\u003e6 kA per IEC 60898-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Curve\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e240 - 415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 - 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V (4,000 V impulse withstand)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Width\u003c\/td\u003e\n\u003ctd\u003e1 module (17.5 mm) — same across all ratings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 60898-1, IEC 60947-2, IEC 60664\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in France\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential mains distribution and consumer units\u003c\/li\u003e\n\u003cli\u003eCommercial lighting, socket, and small power circuits\u003c\/li\u003e\n\u003cli\u003eCircuits with moderate inrush loads (motors, ballasts, transformers) suited to a Type C curve\u003c\/li\u003e\n\u003cli\u003eExpanding or retrofitting existing Hager DIN-rail distribution boards across the UAE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich rating (6A-63A) do I need for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe correct rating depends on the connected load and the cable's current-carrying capacity — an undersized breaker will nuisance-trip, an oversized one won't protect the cable. Always size the MCB to the circuit design, not just the appliance rating; a licensed electrician can confirm the correct choice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C breakers trip instantaneously at roughly 5-10 times their rated current, giving them enough headroom to ride out the brief inrush of motors, transformers, and fluorescent\/LED lighting ballasts without nuisance tripping, while still tripping fast on a genuine fault.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other Hager DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes. It's a standard 1-module, DIN-rail (EN 60715) mounted breaker and clips directly into Hager's modular consumer units and distribution boards alongside other Hager DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need for a single-phase circuit?\u003c\/strong\u003e\u003cbr\u003eA single 1-pole (1P) breaker switches the line conductor only, which is the standard choice for individual single-phase final circuits (lighting, sockets). Where full double-pole isolation is required, a 2-pole device is used instead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"6A","offer_id":41559032954979,"sku":"MCN106","price":17.0,"currency_code":"AED","in_stock":true},{"title":"10A","offer_id":41559032987747,"sku":"MCN110A","price":17.0,"currency_code":"AED","in_stock":true},{"title":"16A","offer_id":41549413253219,"sku":"MCN116","price":17.0,"currency_code":"AED","in_stock":true},{"title":"20A","offer_id":41549413285987,"sku":"MCN120","price":23.0,"currency_code":"AED","in_stock":true},{"title":"25A","offer_id":41559033020515,"sku":"MCN125","price":17.0,"currency_code":"AED","in_stock":true},{"title":"32A","offer_id":41559033053283,"sku":"MCN132","price":17.0,"currency_code":"AED","in_stock":true},{"title":"40A","offer_id":41559033086051,"sku":"MCN140","price":17.0,"currency_code":"AED","in_stock":true},{"title":"50A","offer_id":41559033118819,"sku":"MCN150","price":17.0,"currency_code":"AED","in_stock":true},{"title":"63A","offer_id":41559033151587,"sku":"MCN163","price":17.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/hager-mcbs-6a-hager-miniature-circuit-breaker-mcb-1-pole-made-in-france-31538397282403.jpg?v=1787498087"},{"product_id":"abb-1p-mcb-6ka-type-c","title":"ABB MCB 1-Pole 6kA Type C — SH203 Range (6A–63A)","description":"\u003cdiv\u003e\n\u003cp\u003eABB Miniature Circuit Breaker 1P 6KA Type C (6A–32A) provides reliable overload and short-circuit protection for residential, commercial, and light industrial panels. Available in six current ratings, it supports modest inrush on lighting, socket outlets, and small motors while staying compact for DIN-rail distribution boards.\u003c\/p\u003e \u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eSingle Pole (1P) protection\u003c\/li\u003e \u003cli\u003eBreaking capacity: 6KA\u003c\/li\u003e \u003cli\u003eTripping curve: Type C\u003c\/li\u003e \u003cli\u003eDIN rail mount for quick panel integration\u003c\/li\u003e \u003cli\u003eRatings: 6A, 10A, 16A, 20A, 25A, 32A\u003c\/li\u003e \u003cli\u003eApplications: residential, commercial, small motor protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePole\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6KA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eTripping Curve\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eAvailable Ratings\u003c\/td\u003e\n\u003ctd\u003e6A, 10A, 16A, 20A, 25A, 32A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eApplications\u003c\/td\u003e\n\u003ctd\u003eResidential Distribution Boards; Commercial Electrical Panels; Lighting \u0026amp; Socket Circuits; Small Motor Protection; Industrial Control Panels\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eTypical installations\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eResidential distribution boards\u003c\/li\u003e \u003cli\u003eLighting circuits and socket outlets\u003c\/li\u003e \u003cli\u003eSmall motor protection in light commercial apps\u003c\/li\u003e \u003cli\u003eCommercial electrical panels\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 1-pole (1P) breaker switches the line conductor only — the standard choice for individual single-phase final circuits (lighting, sockets).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"6A","offer_id":41559671439459,"sku":"ABBMCB6A","price":14.0,"currency_code":"AED","in_stock":true},{"title":"10A","offer_id":41559671472227,"sku":"ABBMCB10A","price":14.0,"currency_code":"AED","in_stock":true},{"title":"16A","offer_id":41559671537763,"sku":"ABBMCB16A","price":14.0,"currency_code":"AED","in_stock":true},{"title":"20A","offer_id":41559671570531,"sku":"ABBMCB20A","price":14.0,"currency_code":"AED","in_stock":true},{"title":"25A","offer_id":41559671603299,"sku":"ABBMCB25A","price":14.0,"currency_code":"AED","in_stock":true},{"title":"32A","offer_id":41559671636067,"sku":"ABBMCB32A","price":14.0,"currency_code":"AED","in_stock":true},{"title":"40A","offer_id":41559671701603,"sku":"ABBMCB40A","price":14.0,"currency_code":"AED","in_stock":true},{"title":"50A","offer_id":41559671734371,"sku":"ABBMCB50A","price":14.0,"currency_code":"AED","in_stock":true},{"title":"63A","offer_id":41559671767139,"sku":"ABBMCB63A","price":14.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-mcbs-6a-abb-miniature-circuit-breaker-1p-mcb-6ka-type-c-31538352652387.jpg?v=1787498095"},{"product_id":"abb-16a-3-pole-miniature-circuit-breaker-sh203m-c16","title":"ABB SH203M-C16 MCB 16A 3-Pole 10kA Type C","description":"\u003cdiv\u003e\n\u003ch2\u003eABB SH203M-C16 3-Pole 16A Type C MCB\u003c\/h2\u003e\n\u003cp\u003eA genuine ABB 3-pole MCB, 16A, 10kA breaking capacity — commonly used to protect a 3-phase circuit such as a central AC unit or larger appliance in a villa or commercial distribution board.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3-pole standard miniature circuit breaker\u003c\/li\u003e\n\u003cli\u003eCurrent rating: 16A\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 10kA\u003c\/li\u003e\n\u003cli\u003eModel: SH203M-C16 (2CDS273011R0164)\u003c\/li\u003e\n\u003cli\u003eBrand: ABB\u003c\/li\u003e\n\u003cli\u003eCompact footprint for space-constrained installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSH203M-C16 (2CDS273011R0164)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVilla distribution boards — 3-phase AC and appliance circuits\u003c\/li\u003e\n\u003cli\u003eResidential sub-panels\u003c\/li\u003e\n\u003cli\u003eCommercial lighting and power circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e10kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy 3-pole for this circuit?\u003c\/strong\u003e\u003cbr\u003eA 3-pole (3P) breaker switches all three phases of a three-phase supply, which is what a central AC unit or larger three-phase appliance circuit needs — a single-pole breaker only switches the line conductor on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product, even for a like-for-like replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797518164067,"sku":"SH203M-C16","price":124.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000378857_400x400_0a0ed2ef-fce4-4b24-ab43-11c418b0283c.png?v=1787499435"},{"product_id":"abb-40a-3-pole-miniature-circuit-breaker","title":"ABB SH203M-C40 MCB 40A 3-Pole 10kA Type C","description":"\u003cdiv\u003e\n\u003cp\u003eABB Miniature Circuit Breaker SH203M-C40 is a three-pole, 40 A MCB designed for reliable fault protection in distribution boards, control panels, and commercial\/industrial electrical systems. With a 10 kA breaking capacity, it quickly isolates faults to minimise damage and downtime.\u003c\/p\u003e \u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eBrand: ABB\u003c\/li\u003e \u003cli\u003eModel: SH203M-C40\u003c\/li\u003e \u003cli\u003eType: Standard, 3-pole\u003c\/li\u003e \u003cli\u003eCurrent rating: 40 A\u003c\/li\u003e \u003cli\u003eBreaking capacity: 10 kA\u003c\/li\u003e \u003cli\u003eManufacturer part: 2CDS273011R0404\u003c\/li\u003e \u003cli\u003eReliable protection for electrical circuits in UAE installations\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSH203M-C40\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eStandard, 3-pole\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCurrent rating\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eBreaking capacity\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eManufacturer part\u003c\/td\u003e\n\u003ctd\u003e2CDS273011R0404\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eResidential distribution boards\u003c\/li\u003e \u003cli\u003eCommercial control panels\u003c\/li\u003e \u003cli\u003eIndustrial electrical installations\u003c\/li\u003e \u003cli\u003eBackup power and sub-panel protection\u003c\/li\u003e \u003cli\u003eRenewable energy system secondary protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e10kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 3-pole (3P) breaker switches all three phases on a three-phase circuit without a switched neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797518196835,"sku":"SH203-C40","price":83.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-mcbs-default-title-abb-three-pole-miniature-circuit-breaker-40-amp-mcb-10ka-sh203m-c40-2cds273011r0404-31538364940387.jpg?v=1787498170"},{"product_id":"abb-6a-3-pole-miniature-circuit-breaker","title":"ABB SH203-C6 MCB 6A 3-Pole 6kA Type C","description":"\u003cdiv\u003e\n\u003ch2\u003eABB SH203-C6 3-Pole Miniature Circuit Breaker, 6 A, 400 V\u003c\/h2\u003e\n\u003cp\u003eProtect installations from overload and short-circuits with ABB’s System pro M compact S200 3‑pole MCB. This 6 A device combines reliable current-limiting protection with space-saving installation features, designed for domestic and residential applications across markets that require IEC, UL, and CSA compliance.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3 poles with 6 A rating, 400 V\u003c\/li\u003e\n\u003cli\u003eCurrent-limiting overcurrent protection with dual tripping mechanisms\u003c\/li\u003e\n\u003cli\u003eSpace-saving bottom-fixing auxiliary contact design\u003c\/li\u003e\n\u003cli\u003eWide market coverage with international standards compliance (IEC, UL, CSA)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting for quick, secure installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e6 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e400 Volts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Code\u003c\/td\u003e\n\u003ctd\u003e2CDS213001R0064\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSystem pro M compact S200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDomestic and residential installations in specified markets\u003c\/li\u003e\n\u003cli\u003eProtection for lighting circuits, outlets, and small appliance circuits\u003c\/li\u003e\n\u003cli\u003eDistribution boards and consumer units where compact, reliable MCB protection is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 3-pole (3P) breaker switches all three phases on a three-phase circuit without a switched neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797518229603,"sku":"SH203-C6","price":60.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000150980_400x400_5c6ca43a-6cc5-4877-9f80-94ff24a72b9e.jpg?v=1786965542"},{"product_id":"abb-16a-3-pole-miniature-circuit-breaker","title":"ABB S203M-C16 MCB 16A 3-Pole 10kA Type C","description":"\u003cdiv\u003e\n\u003cp\u003eABB Miniature Circuit Breaker S203M-C16 is a 3-pole, 16A MCB designed for reliable protection in 230V distribution systems. With a 10kA breaking capacity and DIN-rail mounting, it suits control panels, switchboards, and industrial installations across the UAE.\u003c\/p\u003e \u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003ePatented twin terminals: Captive screws provide highest comfort, safety, and flexibility\u003c\/li\u003e \u003cli\u003eSpace and time saving design: Unique bottom-fixing auxiliary contact\u003c\/li\u003e \u003cli\u003eWide range of accessories: Enhance MCB functions for control and remote monitoring\u003c\/li\u003e \u003cli\u003eCompliance with worldwide standards: Ensures versatility for various applications\u003c\/li\u003e \u003cli\u003eWide and complete range of MCBs: Catering to different markets and applications\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eSpecification\u003c\/th\u003e \u003cth\u003eDetails\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eABB\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eModel\u003c\/td\u003e \u003ctd\u003eS203M-C16\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePart Number\u003c\/td\u003e \u003ctd\u003e2CDS273001R0164\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCurrent Rating\u003c\/td\u003e \u003ctd\u003e16 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage\u003c\/td\u003e \u003ctd\u003e230 V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePole Configuration\u003c\/td\u003e \u003ctd\u003e3P\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBreaking Capacity\u003c\/td\u003e \u003ctd\u003e10 kA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMounting Type\u003c\/td\u003e \u003ctd\u003eDIN Rail\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard MCB\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eIdeal use cases\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eControl panels and motor control centers in industrial settings\u003c\/li\u003e \u003cli\u003eDistribution boards in commercial and residential complexes\u003c\/li\u003e \u003cli\u003eSystems requiring reliable 3P protection with easy remote monitoring options\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e10kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 3-pole (3P) breaker switches all three phases on a three-phase circuit without a switched neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797518426211,"sku":"S203M-C16","price":82.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-mcbs-default-title-abb-three-pole-miniature-circuit-breaker-16a-tp-mcb-10ka-type-s203m-c16-2cds273001r0164-31538367365219.jpg?v=1787498170"},{"product_id":"abb-mcb-10a-3p-type-c-sh203-c10","title":"ABB SH203-C10 MCB 10A 3-Pole 6kA Type C","description":"\u003cdiv\u003e\n\u003ch2\u003eABB Miniature Circuit Breaker 10A 3 Pole TYPE C SH203-C10\u003c\/h2\u003e \u003cp\u003eProtect 3‑phase installations with reliable overload and short‑circuit protection. This ABB 3‑pole MCB (SH203-C10) is part of the System pro M compact S200 family, delivering current‑limiting performance with thermal and magnetic trips, compliant with IEC, UL and CSA standards for domestic and light commercial boards in the UAE.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e3‑pole protection for 3‑phase circuits\u003c\/li\u003e \u003cli\u003eType C magnetic trip curve for manageable fault currents\u003c\/li\u003e \u003cli\u003eThermal (overload) and magnetic (short‑circuit) tripping\u003c\/li\u003e \u003cli\u003eCurrent‑limiting protection for faster fault clearance\u003c\/li\u003e \u003cli\u003eSystem pro M compact S200 series\u003c\/li\u003e \u003cli\u003eBottom‑fixing auxiliary contact saves space\u003c\/li\u003e \u003cli\u003eThrough‑hole mounting for quick panel installation\u003c\/li\u003e \u003cli\u003eIEC, UL, CSA compliant\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCurrent rating\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eTrip Mechanisms\u003c\/td\u003e\n\u003ctd\u003eThermal (overload) and Magnetic (short‑circuit)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eTrip Curve\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eThrough‑Hole Mount\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSystem pro M compact S200\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eAuxiliary Contact\u003c\/td\u003e\n\u003ctd\u003eBottom fixing\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDatasheet\u003c\/td\u003e\n\u003ctd\u003eDownload PDF\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eResidential distribution boards and consumer units\u003c\/li\u003e \u003cli\u003eThree‑phase lighting and small commercial circuits\u003c\/li\u003e \u003cli\u003eMotor control circuits up to 10 A per phase\u003c\/li\u003e \u003cli\u003eRenewables and building automation panels\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 3-pole (3P) breaker switches all three phases on a three-phase circuit without a switched neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797518590051,"sku":"SH203-C10","price":60.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-mcbs-default-title-abb-three-pole-miniature-circuit-breaker-10a-tp-mcb-6ka-type-c-sh203-c10-2cds213001r0104-31538367430755.jpg?v=1787498170"},{"product_id":"abb-mcb-20a-3p-10ka-sh203m-c20","title":"ABB SH203M-C20 MCB 20A 3-Pole 10kA Type C","description":"\u003cdiv\u003e\n\u003ch2\u003eABB Miniature Circuit Breaker 20A 3 Pole 10KA SH203M-C20\u003c\/h2\u003e\n\u003cp\u003eReliable ABB protection for miniature installations with a 20 A rating, three poles, and a 10 kA breaking capacity. Compact, easy to install, and built for demanding UAE electrical environments.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree-pole (3P) configuration for multi-phase circuit protection\u003c\/li\u003e\n\u003cli\u003eRated current: 20 A with 10 kA breaking capacity (Icn) at 400 V AC\u003c\/li\u003e\n\u003cli\u003eType C tripping curve for general-purpose overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003eDual trip mechanism: delayed thermal (overload) and electromagnetic (short-circuit)\u003c\/li\u003e\n\u003cli\u003eComplies with IEC\/EN 60898-1\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting (TH35-7.5 \/ TH35-15 per IEC 60715)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e SH203M-C20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 20 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaker Type:\u003c\/strong\u003e Standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e 10 kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSH203M-C20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaker Type\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial electrical panels\u003c\/li\u003e\n\u003cli\u003eLight industrial control circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e10kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 3-pole (3P) breaker switches all three phases on a three-phase circuit without a switched neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797518721123,"sku":"SH203M-C20","price":83.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-mcbs-default-title-abb-three-pole-miniature-circuit-breaker-20-amp-mcb-10ka-sh203m-c20-2cds273011r0204-31538367234147.jpg?v=1787498173"},{"product_id":"abb-mcb-16a-2p-6ka-type-c-s202-c16","title":"ABB S202-C16 MCB 16A 2-Pole 6kA Type C","description":"\u003cdiv\u003e\n\u003ch2\u003eABB S202-C16 2P Miniature Circuit Breaker — 16 A, 6 kA, Type C\u003c\/h2\u003e\n\u003cp\u003eThe ABB S202-C16 2P miniature circuit breaker delivers reliable, fast-acting protection for UAE electrical installations. With a 16 A rating, 240 V operating voltage, and 6 kA breaking capacity, it guards circuits against overloads and short circuits. The Type C trip curve suits general-purpose circuits with moderate inrush currents.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2-pole configuration for simultaneous protection of line and neutral\u003c\/li\u003e\n\u003cli\u003eCurrent rating: 16 A at 240 V\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 6 kA, ensuring safe interruption during faults\u003c\/li\u003e\n\u003cli\u003eTrip curve: Type C for general-purpose protection\u003c\/li\u003e\n\u003cli\u003eModel: S202-C16 (Part Number: 2CDS252001R0164)\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS202-C16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e2CDS252001R0164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.22 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProtection for distribution boards in villas, offices, and retail outlets\u003c\/li\u003e\n\u003cli\u003eResidential and light commercial circuits where moderate inrush may occur\u003c\/li\u003e\n\u003cli\u003eUpgrade or retrofit projects requiring reliable ABB components\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (2P) breaker switches both live and neutral together, giving full isolation on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797518786659,"sku":"S202-C16","price":89.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000081668_400x400_957f6791-78a8-47f8-8122-9933b5f64143.png?v=1786954778"},{"product_id":"abb-mcb-20a-3-pole-type-c-s203m-c20","title":"ABB S203M-C20 MCB 20A 3-Pole 10kA Type C","description":"\u003cdiv\u003e\n\u003ch2\u003eABB S203M-C20 3-Pole 20A Type C Miniature Circuit Breaker\u003c\/h2\u003e\n\u003cp\u003eThe ABB S203M‑C20 is a compact, 3‑pole miniature circuit breaker designed for reliable overload and short‑circuit protection across residential, commercial, marine, and light rail panels in the UAE. Its current‑limiting design, twin terminals with captive screws, and bottom‑fixing auxiliary contact simplify installation and save panel space.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eType: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n\u003cli\u003ePoles: 3\u003c\/li\u003e\n\u003cli\u003eTripping mechanisms: Delayed thermal (overload); Electromechanical (short circuit)\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 10 kA \/ 15 kA\u003c\/li\u003e\n\u003cli\u003eCurrent rating: 20 A\u003c\/li\u003e\n\u003cli\u003eVoltage: 400 V\u003c\/li\u003e\n\u003cli\u003eUnique features: Patented twin terminals with captive screws\u003c\/li\u003e\n\u003cli\u003eInstallation: Bottom‑fixing auxiliary contact for space and time savings\u003c\/li\u003e\n\u003cli\u003eGlobal compatibility: Designed to meet worldwide standards for cross‑market use\u003c\/li\u003e\n\u003cli\u003eAccessory compatibility: Wide range of control\/monitoring accessories supported\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e3‑pole miniature circuit breaker (Type C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent rating\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping mechanisms\u003c\/td\u003e\n\u003ctd\u003eDelayed thermal (overload); Electromechanical (short‑circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity\u003c\/td\u003e\n\u003ctd\u003e10 kA \/ 15 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003ePatented twin terminals with captive screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\/auxiliary contact\u003c\/td\u003e\n\u003ctd\u003eBottom‑fixing auxiliary contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential distribution boards and consumer mains\u003c\/li\u003e\n\u003cli\u003eCommercial electrical panels and switchboards\u003c\/li\u003e\n\u003cli\u003eMaritime electrical systems and coastal environments\u003c\/li\u003e\n\u003cli\u003eRailway and light rail infrastructure control panels\u003c\/li\u003e\n\u003cli\u003eIndustrial protection in UAE facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e10kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 3-pole (3P) breaker switches all three phases on a three-phase circuit without a switched neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797518983267,"sku":"S203M-C20","price":93.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-mcbs-default-title-abb-s203m-c20-miniature-circuit-breaker-3-pole-type-c-10ka-15ka-breaking-capacity-20-amp-current-2cds273001r0204-31538351439971.jpg?v=1787498173"},{"product_id":"abb-mcb-32a-3-pole-10ka-sh203m-c32","title":"ABB SH203M-C32 MCB 32A 3-Pole 10kA Type C","description":"\u003cdiv\u003e\n\u003ch2\u003eABB SH203M-C32 3-Pole Miniature Circuit Breaker, 32 A, 10 kA\u003c\/h2\u003e\n\u003cp\u003eABB SH203M-C32 three-pole MCB for safe, reliable overcurrent protection in residential and light commercial installations. With a 32 A rating and 10 kA breaking capacity, it delivers dependable performance and easy panel integration for UAE projects.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree-pole configuration for multi-phase protection\u003c\/li\u003e\n\u003cli\u003eRated current: 32 A\u003c\/li\u003e\n\u003cli\u003eShort-circuit breaking capacity: 10 kA\u003c\/li\u003e\n\u003cli\u003eStandard circuit breaker type for versatile use\u003c\/li\u003e\n\u003cli\u003eBrand: ABB; model SH203M-C32\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSH203M-C32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e2CDS273011R0324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential distribution boards and lighting circuits\u003c\/li\u003e\n\u003cli\u003eSmall to medium commercial installations requiring reliable overcurrent protection\u003c\/li\u003e\n\u003cli\u003eTemporary or permanent electrical panels where quick, safe disconnection is needed\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e10kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 3-pole (3P) breaker switches all three phases on a three-phase circuit without a switched neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797519442019,"sku":"SH203M-C32","price":93.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-mcbs-default-title-abb-three-pole-miniature-circuit-breaker-32-amp-mcb-10ka-sh203m-c32-2cds273011r0324-31538365890659.jpg?v=1787498176"},{"product_id":"abb-sh203-c25-25a-3p-mcb-type-c","title":"ABB SH203-C25 MCB 25A 3-Pole 6kA Type C","description":"\u003cdiv\u003e\n\u003ch2\u003eABB Miniature Circuit Breaker — 3-Poles, 25A, Type C (2CDS213001R0254)\u003c\/h2\u003e\n\u003cp\u003eEnhance safety and reliability in electrical installations with ABB's compact three-pole MCB. Designed for space-efficient protection of distribution boards and moderate-load circuits, this unit combines ABB engineering with practical UAE-ready performance.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompact three-pole design for tight panel spaces\u003c\/li\u003e\n\u003cli\u003eRated current 25 A with 6 kA breaking capacity\u003c\/li\u003e\n\u003cli\u003eType C tripping characteristic for general-purpose protection\u003c\/li\u003e\n\u003cli\u003eThrough-hole mounting flexibility for versatile installations\u003c\/li\u003e\n\u003cli\u003eDurable construction and reliable ABB brand support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2CDS213001R0254\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003eThree\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristics\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.5 x 5.2 x 6.9 cm (L x W x H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProtection for distribution boards in residential and light commercial settings\u003c\/li\u003e\n\u003cli\u003eModerate-load circuits such as lighting and outlets\u003c\/li\u003e\n\u003cli\u003eRetrofits and panel upgrades where space is at a premium\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 3-pole (3P) breaker switches all three phases on a three-phase circuit without a switched neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797520883811,"sku":"SH203-C2","price":69.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-mcbs-default-title-abb-three-pole-miniature-circuit-breaker-25a-tp-mcb-6ka-type-c-sh203-c25-2cds213001r0254-31538369855587.jpg?v=1787498179"},{"product_id":"abb-sh203-c32-32a-3p-mcb-type-c","title":"ABB SH203-C32 MCB 32A 3-Pole 6kA Type C","description":"\u003cdiv\u003e\n\u003ch2\u003eABB Miniature Circuit Breaker 32A 3-Pole Type C SH203-C32\u003c\/h2\u003e\n\u003cp\u003eSystem pro M compact S200 series three-pole MCB with dual trip mechanisms for reliable overload and short-circuit protection. Designed for domestic\/residential installations in defined markets, it features current limiting protection and a space-saving bottom-fixing auxiliary contact design.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree-pole (3P) MCB for multi-phase distribution protection\u003c\/li\u003e\n\u003cli\u003eRated current: 32 A with 6 kA breaking capacity at 230\/400 V AC\u003c\/li\u003e\n\u003cli\u003eType C tripping curve, suited for general electrical loads\u003c\/li\u003e\n\u003cli\u003eDual trip mechanism: delayed thermal (overload) and electromagnetic (short-circuit)\u003c\/li\u003e\n\u003cli\u003eComplies with IEC\/EN 60898-1\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting (TH35-7.5 \/ TH35-15 per IEC 60715)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eThree-pole, 32 A, Type C\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 6 kA\u003c\/li\u003e\n\u003cli\u003eDual trip: delayed thermal for overload and magnetic for short circuit\u003c\/li\u003e\n\u003cli\u003eSystem pro M compact S200 family\u003c\/li\u003e\n\u003cli\u003eBottom fixing auxiliary contact for space-saving installation\u003c\/li\u003e\n\u003cli\u003eStandards: IEC, UL, CSA\u003c\/li\u003e\n\u003cli\u003eMaterial: Durable plastic housing\u003c\/li\u003e\n\u003cli\u003eON-OFF operation mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSH203-C32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping characteristics\u003c\/td\u003e\n\u003ctd\u003eThermal (overload) + Magnetic (short-circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity\u003c\/td\u003e\n\u003ctd\u003e6 kA (Icn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSystem pro M compact S200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eBottom fixing auxiliary contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eDurable plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation\u003c\/td\u003e\n\u003ctd\u003eON-OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDomestic and residential circuits in defined UAE markets\u003c\/li\u003e\n\u003cli\u003eThree-pole protection for multi-wire distribution boards\u003c\/li\u003e\n\u003cli\u003eSmall-scale commercial installations requiring reliable overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 3-pole (3P) breaker switches all three phases on a three-phase circuit without a switched neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797520949347,"sku":"Sh203-C32","price":60.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-mcbs-default-title-abb-three-pole-miniature-circuit-breaker-32a-tp-mcb-6ka-type-c-sh203-c32-2cds213001r0324-31538365333603.jpg?v=1787498180"},{"product_id":"abb-sh203m-c63-63a-3p-mcb-10ka","title":"ABB SH203M-C63 MCB 63A 3-Pole 10kA Type C","description":"\u003cdiv\u003e\n\u003ch2\u003eABB SH203M-C63 3-Pole Miniature Circuit Breaker – 63 A, 10 kA\u003c\/h2\u003e\n\u003cp\u003eABB’s three‑pole miniature circuit breaker (MCB) SH203M-C63 delivers reliable protection for three‑phase distribution circuits with a 63 A rating and a 10 kA breaking capacity. Designed for versatile use in UAE installations, it combines ABB reliability with straightforward installation and clear trip indication.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree-pole (3P) configuration for three-phase distribution protection\u003c\/li\u003e\n\u003cli\u003eRated current: 63 A with 10 kA breaking capacity at 230\/400 V AC\u003c\/li\u003e\n\u003cli\u003eType C tripping curve for general-purpose protection\u003c\/li\u003e\n\u003cli\u003eDual trip mechanism: delayed thermal (overload) and electromagnetic (short-circuit)\u003c\/li\u003e\n\u003cli\u003eComplies with IEC\/EN 60898-1\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting, suitable for installation in any position\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eThree-pole miniature circuit breaker for three-phase protection\u003c\/li\u003e\n\u003cli\u003eCurrent rating: 63 A\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 10 kA\u003c\/li\u003e\n\u003cli\u003eType: Standard\u003c\/li\u003e\n\u003cli\u003eModel\/Part: SH203M-C63 (2CDS273011R0634)\u003c\/li\u003e\n\u003cli\u003eManufacturer: ABB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part\u003c\/td\u003e\n\u003ctd\u003eSH203M-C63 (2CDS273011R0634)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree‑phase distribution in commercial and residential UAE projects\u003c\/li\u003e\n\u003cli\u003eProtection for MCCBs and main distribution boards in UAE contractors’ installs\u003c\/li\u003e\n\u003cli\u003eSuitable for standard circuit protection where reliable trip performance is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e10kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 3-pole (3P) breaker switches all three phases on a three-phase circuit without a switched neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797520982115,"sku":"SH203M-C63","price":123.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-mcbs-default-title-abb-three-pole-miniature-circuit-breaker-63-amp-mcb-10ka-sh203m-c63-2cds273011r0634-31538367397987.jpg?v=1787498182"},{"product_id":"abb-sh202-c40-40a-dp-mcb-type-c","title":"ABB SH202-C40 MCB 40A 2-Pole 6kA Type C","description":"\u003cdiv\u003e\n\u003cp\u003eThe ABB Double Pole Miniature Circuit Breaker 40A DP MCB C SH202-C40 (2CDS212001R0404) delivers reliable overcurrent and short-circuit protection for residential, commercial, and light industrial electrical systems. Compact and easy to install, it suits panel boards and distribution boards in UAE projects.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDouble pole design (2P) for enhanced protection of both active and neutral paths\u003c\/li\u003e\n\u003cli\u003e40 A current rating suitable for moderate to heavy loads in UAE installations\u003c\/li\u003e\n\u003cli\u003eC Curve, 6 kA breaking capacity for fast interruption of faults\u003c\/li\u003e\n\u003cli\u003eCompact footprint: 8.5 × 3.5 × 6.9 cm for easy panel fit\u003c\/li\u003e\n\u003cli\u003eOperating voltage up to 400 V\u003c\/li\u003e\n\u003cli\u003eManufactured by ABB, SH202-C40 | part 2CDS212001R0404\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSH202-C40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e2CDS212001R0404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDouble Pole Miniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurve\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e8.5 × 3.5 × 6.9 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eResidential distribution boards and small commercial panels\u003c\/li\u003e\n\u003cli\u003eProtection for motors and lighting circuits in UAE installations\u003c\/li\u003e\n\u003cli\u003eBackup protection in automation and control circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (2P) breaker switches both live and neutral together, giving full isolation on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797521244259,"sku":"SH202-C40","price":52.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-mcbs-default-title-abb-double-pole-miniature-circuit-breaker-40a-dp-mcb-c-sh202-c40-2cds212001r0404-31538351308899.jpg?v=1787498184"},{"product_id":"abb-sh202-c32-32a-dp-mcb-type-c","title":"ABB SH202-C32 MCB 32A 2-Pole 6kA Type C","description":"\u003cdiv\u003e\n\u003ch2\u003eABB Miniature Circuit Breaker 32A DP MCB C SH202-C32\u003c\/h2\u003e\n\u003cp\u003eThe ABB 32A Double Pole Miniature Circuit Breaker (DP MCB) SH202-C32 delivers reliable overcurrent protection for UAE residential and light commercial panels. Compact, easy to install, and built to ABB standards for dependable performance.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eCurrent rating: 32 A\u003c\/li\u003e \u003cli\u003eDouble-pole configuration for line and neutral protection\u003c\/li\u003e \u003cli\u003eTripping curve: C (standard general protection)\u003c\/li\u003e \u003cli\u003eStandard breaker type for straightforward replacements\u003c\/li\u003e \u003cli\u003eDurable ABB construction for long-term use\u003c\/li\u003e \u003cli\u003eModel\/Part: SH202-C32 | Part Number: 2CDS212001R0324\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eDouble Pole Miniature Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eModel \/ Part\u003c\/td\u003e\n\u003ctd\u003eSH202-C32\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e2CDS212001R0324\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eBreaker Type\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eTripping Curve\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eResidential distribution boards and consumer units\u003c\/li\u003e \u003cli\u003eLight commercial circuits requiring 32 A protection\u003c\/li\u003e \u003cli\u003eRetrofits and new installations in UAE panels\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (2P) breaker switches both live and neutral together, giving full isolation on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797521375331,"sku":"SH202-C32","price":52.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-mcbs-default-title-abb-double-pole-miniature-circuit-breaker-32a-dp-mcb-c-sh202-c32-2cds212001r0324-31538352095331.jpg?v=1787498184"},{"product_id":"abb-sh203-c20-20a-3p-mcb-type-c","title":"ABB SH203-C20 MCB 20A 3-Pole 6kA Type C","description":"\u003cdiv\u003e\n\u003cp\u003eABB SH203-C20 three-pole miniature circuit breaker delivers reliable protection for 400 V AC circuits in UAE installations. With a 20 A rating and 6 kA breaking capacity, it fits standard DIN-rail panels and supports a wide range of accessories for remote control and monitoring.\u003c\/p\u003e \u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eThree-pole design for balanced three-phase protection\u003c\/li\u003e \u003cli\u003eCurrent rating: 20 A; Voltage: 400 V AC\u003c\/li\u003e \u003cli\u003eBreaking capacity: 6 kA (Icu) at 400 V AC\u003c\/li\u003e \u003cli\u003eDIN rail mounting for compact, space-saving installations\u003c\/li\u003e \u003cli\u003eType C tripping curve for general-purpose protection of commercial and light industrial circuits\u003c\/li\u003e \u003cli\u003eWide accessory compatibility for remote control and monitoring\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eSpecification\u003c\/th\u003e \u003cth\u003eValue\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eProduct Type\u003c\/td\u003e \u003ctd\u003eABB Miniature Circuit Breaker - SH203-C20\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePoles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCurrent Rating\u003c\/td\u003e \u003ctd\u003e20 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage\u003c\/td\u003e \u003ctd\u003e400 V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e \u003ctd\u003eStandard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMounting Type\u003c\/td\u003e \u003ctd\u003eDIN Rail Mount\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Curve\u003c\/td\u003e \u003ctd\u003eType C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBreaking Capacity (Icu)\u003c\/td\u003e \u003ctd\u003e6 kA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSeries\u003c\/td\u003e \u003ctd\u003eS200 SH203-C20 range\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eThree-phase distribution panels in commercial and residential buildings\u003c\/li\u003e \u003cli\u003eMotor protection for light industrial equipment\u003c\/li\u003e \u003cli\u003ePanel boards in UAE electrical installations\u003c\/li\u003e \u003cli\u003eMarine and railway panels where appropriate installation standards are met\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 3-pole (3P) breaker switches all three phases on a three-phase circuit without a switched neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797521604707,"sku":"SH203-C20","price":60.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-mcbs-default-title-abb-miniature-circuit-breaker-sh203-c20-three-pole-20-ampere-31538352160867.jpg?v=1787498185"},{"product_id":"abb-sh202-c16-16a-2p-mcb-type-c","title":"ABB SH202-C16 MCB 16A 2-Pole 6kA Type C","description":"\u003cdiv\u003e\n\u003cp\u003eThe ABB SH202-C16 is a 2-pole Miniature Circuit Breaker (MCB) rated at 16 A with a C-curve tripping characteristic. Built for reliability in UAE electrical installations, it protects circuits from overloads and short circuits with a compact, easy-to-operate design.\u003c\/p\u003e \u003ch2\u003eABB 16A DP MCB C SH202-C16\u003c\/h2\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eDouble-pole protection for multi-circuit layouts\u003c\/li\u003e \u003cli\u003eTripping curve: C for inductive and general loads\u003c\/li\u003e \u003cli\u003eCurrent rating: 16 A\u003c\/li\u003e \u003cli\u003ePush-button operation for manual test and reset\u003c\/li\u003e \u003cli\u003eCompact dimensions: 8.5 cm L × 3.5 cm W × 6.9 cm H\u003c\/li\u003e \u003cli\u003eIP00 enclosure rating\u003c\/li\u003e \u003cli\u003ePack: 1 unit\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDouble pole Miniature Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSH202-C16\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCurve Type\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003eDouble Pole\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eController Type\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eUnit Count\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.87 kg (1.3 lb)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd\u003e8.5 × 3.5 × 6.9 cm\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eResidential electrical circuits requiring reliable overload protection\u003c\/li\u003e \u003cli\u003eCommercial panel boards and distribution boards\u003c\/li\u003e \u003cli\u003eIndustrial control panels with standard 16 A protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (2P) breaker switches both live and neutral together, giving full isolation on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797521768547,"sku":"SH202-C16","price":51.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-mcbs-default-title-abb-double-pole-miniature-circuit-breaker-16a-dp-mcb-c-sh202-c16-31538351210595.jpg?v=1787498187"},{"product_id":"abb-s202-c32-mcb-32a-2p-type-c","title":"ABB S202-C32 MCB 32A 2-Pole 6kA Type C","description":"\u003cdiv\u003e\n\u003cp\u003eABB S202-C32 Miniature Circuit Breaker delivers reliable two‑pole protection with current limiting, ideal for UAE electrical installations and modern distribution boards.\u003c\/p\u003e\n\u003ch2\u003eABB S202-C32 Miniature Circuit Breaker — 2P, C, 32 A\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCurrent Limiting for enhanced protection\u003c\/li\u003e\n\u003cli\u003eTwo Tripping Mechanisms: delayed thermal (overload) and electromechanical (short circuit)\u003c\/li\u003e\n\u003cli\u003eWide range of applications: screwless terminals, home panels, ring tongue wiring, UL and universal current, DC, marine, and railway environments\u003c\/li\u003e\n\u003cli\u003eGlobal standards compliant for worldwide installations\u003c\/li\u003e\n\u003cli\u003eAccessory compatibility for extended functions, including remote monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e32 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e400 Volts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurve\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Limiting\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential and commercial distribution boards\u003c\/li\u003e\n\u003cli\u003eMarine electrical systems\u003c\/li\u003e\n\u003cli\u003eRailway and light industry installations\u003c\/li\u003e\n\u003cli\u003eDirect current (DC) applications with appropriate accessories\u003c\/li\u003e\n\u003cli\u003eRemote monitoring-enabled panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (2P) breaker switches both live and neutral together, giving full isolation on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797521866851,"sku":"S202-C32","price":52.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-mcbs-default-title-abb-s202-c32-miniature-circuit-breaker-2p-c-32-a-31538352848995.jpg?v=1787498187"},{"product_id":"abb-16a-3p-mcb-type-c-sh203-c16","title":"ABB SH203-C16 MCB 16A 3-Pole 6kA Type C","description":"\u003cdiv\u003e\n\u003cp\u003eABB SH203-C16 is a 3-pole miniature circuit breaker (MCB) rated for 16 A with a 6 kA breaking capacity, designed for reliable protection in residential and light commercial panels. It features DIN-rail mounting, a space-saving bottom-fixing auxiliary contact, and compliance with IEC, UL and CSA standards for global use, including UAE installations.\u003c\/p\u003e \u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e3-pole MCB, Type C configuration for general-purpose protection\u003c\/li\u003e \u003cli\u003eCurrent rating: 16 A\u003c\/li\u003e \u003cli\u003eOperating voltage: 400 V AC\u003c\/li\u003e \u003cli\u003eBreaking capacity: 6 kA (Icu)\u003c\/li\u003e \u003cli\u003eDIN rail mounting with a compact bottom-fixing auxiliary contact for space savings\u003c\/li\u003e \u003cli\u003eConforms to IEC, UL and CSA standards for worldwide applicability\u003c\/li\u003e \u003cli\u003eSuitable for domestic\/residential installations in defined markets\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eParameter\u003c\/th\u003e \u003cth\u003eValue\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eABB\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eModel\u003c\/td\u003e \u003ctd\u003eSH203-C16\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePoles\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eType\u003c\/td\u003e \u003ctd\u003e3-Pole MCB, Type C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCurrent Rating\u003c\/td\u003e \u003ctd\u003e16 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage\u003c\/td\u003e \u003ctd\u003e400 V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBreaking Capacity\u003c\/td\u003e \u003ctd\u003e6 kA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMounting\u003c\/td\u003e \u003ctd\u003eDIN Rail\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStandards\u003c\/td\u003e \u003ctd\u003eIEC, UL, CSA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eApplications\u003c\/td\u003e \u003ctd\u003eDomestic\/residential installations in defined markets\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDatasheet\u003c\/td\u003e \u003ctd\u003eDownload PDF\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eResidential distribution boards and panel boards\u003c\/li\u003e \u003cli\u003eSmall commercial circuits and lighting branches\u003c\/li\u003e \u003cli\u003eBranch protection for outlets and general-purpose circuits\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 3-pole (3P) breaker switches all three phases on a three-phase circuit without a switched neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797521899619,"sku":"SH203-C16","price":52.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-mcbs-default-title-abb-three-pole-miniature-circuit-breaker-16a-tp-mcb-6ka-type-c-sh203-c16-2cds213001r0164-31538369658979.jpg?v=1787498188"},{"product_id":"abb-2a-2p-mcb-type-c-s202-c2","title":"ABB S202-C2 MCB 2A 2-Pole 6kA Type C","description":"\u003cdiv\u003e\n\u003ch2\u003eABB S202-C2: 2A Double-Pole Miniature Circuit Breaker (Type C, 6 kA)\u003c\/h2\u003e\n\u003cp\u003eThe ABB S202-C2 is a 2 A double-pole miniature circuit breaker from the S200 family. Designed for robust protection and easy integration in UAE electrical panels, it features twin terminals for safe wiring and space-saving accessories to enhance functionality.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003ePatented twin terminals with captive screws for comfort, safety, and wiring flexibility.\u003c\/li\u003e \u003cli\u003eUnique bottom-fixing auxiliary contact design to save space and simplify installation.\u003c\/li\u003e \u003cli\u003eWide range of accessories to extend control and remote monitoring capabilities.\u003c\/li\u003e \u003cli\u003eGlobal standards compliance for diverse applications and installation types.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS200\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS202-C2\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCircuit Breaker Type\u003c\/td\u003e\n\u003ctd\u003eStandard (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePlug-In\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003eDouble Pole (DP)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eProtection for residential distribution boards, lighting circuits, and small commercial sub-panels.\u003c\/li\u003e \u003cli\u003eEasy integration with ABB accessories for control and monitoring in UAE installations.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (2P) breaker switches both live and neutral together, giving full isolation on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797522096227,"sku":"S202-C2","price":114.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-mcbs-default-title-abb-double-pole-miniature-circuit-breaker-2a-dp-mcb-6ka-type-c-s202-c2-2cds252001r0024-31538351538275.jpg?v=1787498189"},{"product_id":"abb-25a-2p-mcb-type-c-s202-c25","title":"ABB S202-C25 MCB 25A 2-Pole 6kA Type C","description":"\u003cdiv\u003e\n\u003ch2\u003eABB Miniature Circuit Breaker S202-C25 — 2P, 25 A, 6 kA, Type C\u003c\/h2\u003e \u003cp\u003eABB S202-C25 is a 2‑pole miniature circuit breaker rated for 25 A with a 6 kA breaking capacity, designed for versatile protection in low‑voltage installations. Part of the S200\/S202 family, it supports screwless and captive-screw terminals, a bottom‑fix auxiliary contact, and a range of accessories for control and remote monitoring. Suitable for residential, commercial, marine, railway, and industrial applications in the UAE, it delivers compact, reliable protection with easy wiring.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-pole (2P) MCB for simultaneous line and neutral protection\u003c\/li\u003e\n\u003cli\u003eRated current: 25 A with 6 kA breaking capacity at 400 V AC\u003c\/li\u003e\n\u003cli\u003eType C tripping curve for general-purpose circuits\u003c\/li\u003e\n\u003cli\u003eDual trip mechanism: delayed thermal (overload) and electromagnetic (short-circuit)\u003c\/li\u003e\n\u003cli\u003eComplies with IEC\/EN 60898-1, IEC\/EN 60947-2 and UL1077\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting (TH35-15, 35 x 15 mm rail)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e \u003cli\u003eBrand: ABB\u003c\/li\u003e \u003cli\u003eCurrent rating: 25 A\u003c\/li\u003e \u003cli\u003eNominal voltage: 72 V\u003c\/li\u003e \u003cli\u003ePoles: 2 (DP)\u003c\/li\u003e \u003cli\u003eBreaker type: Type C\u003c\/li\u003e \u003cli\u003eBreaking capacity: 6 kA\u003c\/li\u003e \u003cli\u003eTerminals: Twin terminals with captive screws\u003c\/li\u003e \u003cli\u003eMounting: Bottom fixing\u003c\/li\u003e \u003cli\u003eAccessory options: Control and remote‑monitoring accessories\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS202-C25\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS200 \/ S202 family\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCurrent rating\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eNominal voltage\u003c\/td\u003e\n\u003ctd\u003e72 V\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eBreaker curve\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eBreaking capacity\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eBottom fixing\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003eTwin terminals with captive screws\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eProtection for DC circuits up to 72 V in electrical panels and control cabinets\u003c\/li\u003e \u003cli\u003eResidential, commercial, marine, and railway installations requiring reliable two‑pole protection\u003c\/li\u003e \u003cli\u003eCompact design suited for space‑constrained distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (2P) breaker switches both live and neutral together, giving full isolation on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797522554979,"sku":"S202-C25","price":52.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-mcbs-default-title-abb-double-pole-miniature-circuit-breaker-25a-dp-mcb-6ka-type-c-s202-c25-2cds252001r0254-31538352554083.jpg?v=1787498191"},{"product_id":"hager-32a-3p-mcb-type-c-mcn332","title":"Hager MCN332 MCB 32A 3-Pole 6kA Type C — Made in France","description":"\u003cdiv\u003e\n\u003cp\u003eThe Hager MCN332 MCB is a 32A, 3-pole miniature circuit breaker designed to protect circuits from overloads and short circuits. With a 6kA breaking capacity and Type C tripping curve, it is suited for residential, commercial, and light industrial panels. Compact, durable, and easy to integrate into distribution boards, it’s a reliable choice for UAE installations.\u003c\/p\u003e \u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e32A rated current, 3P (three-pole) configuration\u003c\/li\u003e \u003cli\u003e6kA breaking capacity for reliable fault interruption\u003c\/li\u003e \u003cli\u003eType C tripping curve for moderate inrush protection\u003c\/li\u003e \u003cli\u003eCompact, durable design with long service life\u003c\/li\u003e \u003cli\u003eIEC safety standards compliant\u003c\/li\u003e \u003cli\u003eEasy integration into distribution boards and panels\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMCN332\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3P (Three Pole)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA (Icn per IEC 60898-1); 10kA (Icu per IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eTripping Curve\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eMCB (Miniature Circuit Breaker)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eIEC safety standards\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eResidential homes, villas, and apartments\u003c\/li\u003e \u003cli\u003eCommercial buildings: offices, schools, hospitals, and retail outlets\u003c\/li\u003e \u003cli\u003eLight industrial power distribution panels\u003c\/li\u003e \u003cli\u003eCircuit protection requiring Type C tripping characteristics\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (like the MCN332) protects the circuit and cabling against overload and short-circuit currents. An RCCB\/RCD instead protects against earth leakage and electric shock. The two devices do different jobs and are typically installed together, not as substitutes for one another.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does 3-pole (3P) mean and when do I need it?\u003c\/strong\u003e\u003cbr\u003eA 3-pole breaker switches all three live phases of a three-phase supply simultaneously. It's used for three-phase loads and distribution circuits, as opposed to a 1-pole or 2-pole device used on single-phase final circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the MCN332 compatible with existing Hager distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes. It's a standard DIN-rail (EN 60715) mounted MCB and integrates directly into Hager's modular consumer units and distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean, and when would I choose it over Type B?\u003c\/strong\u003e\u003cbr\u003eType C trips at roughly 5-10 times rated current, giving it enough margin to handle the inrush of motors and transformers without nuisance tripping. Type B trips at a lower 3-5x threshold and suits purely resistive loads. Type C is the common choice for mixed commercial and light industrial panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797538807907,"sku":"MCN332","price":76.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MCN332.webp?v=1786954813"},{"product_id":"hager-40a-2p-mcb-type-c-mcn240","title":"Hager MCN240 MCB 40A 2-Pole 6kA Type C — Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager MCN240 MCB 40A 2-Pole 6kA Type C — Made in France\u003c\/h2\u003e\n\u003cp\u003eThe Hager MCN240 is a 40A, 2-pole miniature circuit breaker, Made in France, designed to protect electrical installations against overloads and short circuits. With a 6kA breaking capacity and a Type C tripping curve, it suits residential, commercial, and light industrial circuits with moderate inrush currents. The 2-pole (Line + Neutral) configuration provides full double-pole isolation and mounts easily into Hager DIN-rail distribution boards used across UAE installations.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: MCN240, 40A rated current, 2P (double pole) configuration\u003c\/li\u003e\n\u003cli\u003e6kA rated breaking capacity (Icn) to IEC 60898-1\u003c\/li\u003e\n\u003cli\u003eType C tripping curve for circuits with moderate inrush current\u003c\/li\u003e\n\u003cli\u003e2 modules (35mm total width) — compact double-pole DIN-rail footprint\u003c\/li\u003e\n\u003cli\u003eIP20 enclosure rating with a wide -25°C to +70°C operating range\u003c\/li\u003e\n\u003cli\u003eScrew-terminal connections, rigid conductors up to 35mm² \/ flexible up to 25mm²\u003c\/li\u003e\n\u003cli\u003eFully compliant with IEC 60898-1, IEC 60947-2, and IEC 60664\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMCN240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P (Double Pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Icn)\u003c\/td\u003e\n\u003ctd\u003e6 kA per IEC 60898-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Curve\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 - 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V (4,000 V impulse withstand)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Width\u003c\/td\u003e\n\u003ctd\u003e2 modules (35 mm total width)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Capacity\u003c\/td\u003e\n\u003ctd\u003eRigid 1-35 mm² \/ Flexible 1-25 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 60898-1, IEC 60947-2, IEC 60664\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in France\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential villas and apartments\u003c\/li\u003e\n\u003cli\u003eCommercial buildings: offices, schools, hospitals, retail outlets\u003c\/li\u003e\n\u003cli\u003eLight industrial power distribution systems\u003c\/li\u003e\n\u003cli\u003eCircuits requiring double-pole isolation with Type C tripping characteristics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (like the MCN240) protects the circuit and cabling against overload and short-circuit currents. An RCCB\/RCD instead protects against earth leakage and electric shock. The two devices do different jobs and are typically installed together, not as substitutes for one another.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does 2-pole (2P) mean and when do I need it?\u003c\/strong\u003e\u003cbr\u003eA 2-pole breaker switches both the line and neutral conductors together, giving full double-pole isolation. It's typically specified where a circuit or sub-board needs complete disconnection from supply, rather than the single-pole (line-only) switching used on standard final circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the MCN240 compatible with existing Hager distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes. It's a standard DIN-rail (EN 60715) mounted MCB and integrates directly into Hager's modular consumer units and distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between Type B and Type C tripping curves?\u003c\/strong\u003e\u003cbr\u003eType C trips at roughly 5-10 times rated current, giving it enough margin to handle the inrush of motors, transformers, and lighting ballasts without nuisance tripping. Type B trips at a lower 3-5x threshold and suits purely resistive loads. Type C is the common choice for mixed commercial and light industrial circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797538906211,"sku":"MCN240","price":82.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MCN240.webp?v=1786954812"},{"product_id":"hager-40a-2p-isolator-sbn240","title":"Hager SBN240 Isolator 40A 2-Pole — Main Switch Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager Isolator 40A 2P – SBN240\u003c\/h2\u003e\n\u003cp\u003eThe Hager SBN240 is a 40A, 2-pole isolator (switch-disconnector) used as a main switch or local isolation point ahead of MCBs and RCCBs in a distribution board. It provides safe, manual off-load disconnection for maintenance, testing, or emergency shutdown, and is Made in France to Hager's standard build quality for UAE residential, commercial, and light industrial installations.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e40 A rated current, 2-pole (2P) switch-disconnector for single-phase supplies\u003c\/li\u003e\n\u003cli\u003eRated operational voltage 400 V AC, rated insulation voltage 440 V\u003c\/li\u003e\n\u003cli\u003eShort-circuit making capacity 0.84 kA and 1-second short-time withstand of 0.60 kA\u003c\/li\u003e\n\u003cli\u003eCompact 2-module DIN rail enclosure (83 x 35 mm), fits standard consumer units and panels\u003c\/li\u003e\n\u003cli\u003eBiconnect aligned terminals top and bottom, accepting 2.5–16 mm² flexible or 2.5–25 mm² rigid conductors\u003c\/li\u003e\n\u003cli\u003eIP20 protection, 50–60 Hz operation, -20 °C to 70 °C operating range\u003c\/li\u003e\n\u003cli\u003eRated for 60,000 mechanical operations and 5,000 electrical (AC21\/AC22) cycles\u003c\/li\u003e\n\u003cli\u003eComplies with IEC 60947-3 and IEC 60669-2-4; RoHS compliant and REACH-SVHC free\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSBN240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eIsolator \/ Switch-Disconnector (Main Switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaking Capacity\u003c\/td\u003e\n\u003ctd\u003e0.84 kA at 415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Time Withstand\u003c\/td\u003e\n\u003ctd\u003e0.60 kA (1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eBiconnect aligned terminals, top and bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Capacity\u003c\/td\u003e\n\u003ctd\u003e2.5–16 mm² flexible \/ 2.5–25 mm² rigid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Width\u003c\/td\u003e\n\u003ctd\u003e2 modules (83 x 35 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDurability\u003c\/td\u003e\n\u003ctd\u003e60,000 mechanical operations \/ 5,000 electrical cycles (AC21\/AC22)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-3, IEC 60669-2-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in France\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain switch \/ isolation point ahead of an MCB or RCCB distribution board in villas and apartments\u003c\/li\u003e\n\u003cli\u003eCommercial buildings: offices, retail units, schools\u003c\/li\u003e\n\u003cli\u003eLight industrial panels requiring a lockable manual disconnect for maintenance\u003c\/li\u003e\n\u003cli\u003eAny 40A single-phase (2-pole) supply needing off-load isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the SBN240 an MCB or an isolator?\u003c\/strong\u003e\u003cbr\u003eIt's an isolator (switch-disconnector), not an MCB. It has no overload or short-circuit protection — it only provides a manual on\/off disconnect. Despite being listed under \"MCBs\" in some catalogue views, the SBN240 is a main switch\/isolator and should be paired with separate MCBs or RCCBs for circuit protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does 2-pole (2P) mean for this isolator?\u003c\/strong\u003e\u003cbr\u003e2-pole means it switches both the live and neutral conductors together on a single-phase supply, giving full off-load isolation of the circuit rather than switching just the live conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere should this isolator be installed?\u003c\/strong\u003e\u003cbr\u003eTypically as the main incoming switch or a local isolation point ahead of the MCBs\/RCCBs in a distribution board, so the whole board (or a section of it) can be isolated for maintenance without needing to trip individual breakers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is trade-only distribution board equipment and must be installed and connected by a licensed electrician in accordance with local wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan the SBN240 be used to switch a live circuit under load?\u003c\/strong\u003e\u003cbr\u003eIt is rated for on-load switching within its AC21\/AC22 utilisation category, but it is not a protective device — it should be operated as an isolator for maintenance and emergency disconnection, not as a substitute for a circuit breaker.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797539037283,"sku":"SBN240","price":45.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/SBN240.webp?v=1787498920"},{"product_id":"hager-100a-3p-mcb-10ka-hlf390s","title":"Hager HLF390S MCB 100A 3-Pole 10kA — Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager MCB 100A 3P 10kA – HLF390S (Miniature Circuit Breaker)\u003c\/h2\u003e\n\u003cp\u003eThe Hager HLF390S is a 3-pole miniature circuit breaker (MCB) that protects distribution circuits against overload and short-circuit faults. With a 100 A rated current, C-curve tripping, and 10 kA breaking capacity, it's built for higher-demand three-phase circuits in residential, commercial, and industrial panels, and is Made in France to Hager's standard build quality for UAE installations.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3-pole (3P) configuration for three-phase circuit protection\u003c\/li\u003e\n\u003cli\u003e100 A rated current for high-demand distribution circuits\u003c\/li\u003e\n\u003cli\u003eC-curve tripping characteristic, suited to circuits with moderate inrush current\u003c\/li\u003e\n\u003cli\u003e10 kA breaking capacity (Icn to IEC 60898-1, Icu to IEC 60947-2) for reliable fault interruption\u003c\/li\u003e\n\u003cli\u003eCompact 4.5-module width for space-efficient panel integration\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage 500 V, 6000 V impulse withstand, Pollution Degree 3\u003c\/li\u003e\n\u003cli\u003eIP20 protection, screw terminals (top and bottom), -25 °C to 70 °C operating range\u003c\/li\u003e\n\u003cli\u003eComplies with IEC 60898-1 and IEC 60947-2; RoHS compliant and REACH-SVHC free\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHLF390S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eMCB (Miniature Circuit Breaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Curve\u003c\/td\u003e\n\u003ctd\u003eC-curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e10 kA (Icn per IEC 60898-1, Icu per IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e6000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e3 (IEC 60664 \/ 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals, top and bottom; 360° mounting capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Width\u003c\/td\u003e\n\u003ctd\u003e4.5 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 °C to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 60898-1, IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in France\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential complexes and villas with three-phase supply\u003c\/li\u003e\n\u003cli\u003eCommercial offices, malls, schools, and healthcare facilities\u003c\/li\u003e\n\u003cli\u003eIndustrial power distribution systems\u003c\/li\u003e\n\u003cli\u003eProjects requiring high-capacity 3-pole, 100A circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10kA rating mean?\u003c\/strong\u003e\u003cbr\u003e10kA is the breaking capacity — the maximum short-circuit fault current the MCB can safely interrupt without damage. It's matched to the fault levels expected on typical UAE three-phase distribution circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is a C-curve MCB used for?\u003c\/strong\u003e\u003cbr\u003eC-curve breakers tolerate higher inrush\/starting currents (roughly 5–10x rated current) before tripping instantly, making them suitable for circuits with motors, transformers, or other inductive loads — as opposed to B-curve breakers used for simple resistive\/lighting circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need for this circuit?\u003c\/strong\u003e\u003cbr\u003eA 3-pole MCB switches and protects all three phases of a three-phase circuit simultaneously. Use a 3P breaker (like the HLF390S) for three-phase loads; single-phase circuits only need a 1P or 2P device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other Hager distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes. The HLF390S is a standard DIN rail MCB and mounts directly onto Hager consumer units and panel boards alongside other Hager modular devices (RCCBs, RCBOs, isolators) on the same busbar system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCBs are installed inside a distribution board and connected to live supply conductors — this must be done by a licensed electrician in accordance with local wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797539102819,"sku":"HLF390S","price":438.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/HLF390S.webp?v=1786954811"},{"product_id":"hager-63a-4p-mcb-6ka-mcn463","title":"Hager MCN463 MCB 63A 4-Pole 6kA Type C — Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager MCN463 MCB 63A 4-Pole 6kA Type C\u003c\/h2\u003e\n\u003cp\u003eThe Hager MCN463 is a 63A, 4-pole miniature circuit breaker (MCB) built to protect distribution circuits from overloads and short circuits. With a Type C tripping curve and 6kA breaking capacity, it suits circuits with moderate inrush current — motors, transformers, and mixed commercial loads — across residential, commercial, and industrial panels. Made in France, it carries Hager's full European engineering and manufacturing standard for long service life in demanding installations.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e63A rated current, Type C tripping curve (5–10 × In) for loads with moderate inrush\u003c\/li\u003e\n\u003cli\u003e4-pole (4P) design — switches all phases plus neutral together\u003c\/li\u003e\n\u003cli\u003e6kA breaking capacity (Icn) for reliable fault clearance\u003c\/li\u003e\n\u003cli\u003e400V rated operational voltage, 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eCompact 4-module DIN rail mounting, IP20 enclosure\u003c\/li\u003e\n\u003cli\u003eScrew terminals rated 1–35mm² (rigid) \/ 1–25mm² (flexible) conductors\u003c\/li\u003e\n\u003cli\u003eComplies with IEC safety standards for miniature circuit breakers\u003c\/li\u003e\n\u003cli\u003eMade in France — genuine Hager build quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMCN463\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eMCB (Miniature Circuit Breaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P (Four Pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Curve\u003c\/td\u003e\n\u003ctd\u003eType C (5–10 × In)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Icn \/ Ics \/ Icu)\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Width\u003c\/td\u003e\n\u003ctd\u003e4 modules (DIN rail)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd\u003e1–35 mm² (rigid) \/ 1–25 mm² (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC safety standards for MCBs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential villas and apartment complexes\u003c\/li\u003e\n\u003cli\u003eCommercial buildings: offices, schools, hospitals, retail spaces\u003c\/li\u003e\n\u003cli\u003eIndustrial distribution boards and panels\u003c\/li\u003e\n\u003cli\u003eProjects requiring robust 4-Pole 63A MCB protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (like the MCN463) protects circuits and wiring against overload and short-circuit current. An RCCB\/RCD protects people against earth leakage\/electric shock by monitoring current imbalance. The two do different jobs and are typically installed together in a distribution board, not as substitutes for each other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the MCN463 compatible with my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eYes. The MCN463 is a standard 4-module Hager DIN-rail MCB and clips directly onto Hager DB rails alongside other Hager MCBs, RCCBs, and accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C curve mean, and is it right for my circuit?\u003c\/strong\u003e\u003cbr\u003eType C breakers trip on short circuit at 5–10 times their rated current, giving them tolerance for the inrush of motors, transformers, and other inductive loads. They're a common general-purpose choice for commercial and light industrial circuits; Type B is typically reserved for purely resistive residential circuits with low inrush.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need for a 4-pole circuit?\u003c\/strong\u003e\u003cbr\u003eA 4-pole (4P) breaker switches all three phases plus the neutral. Use 4P when you need to fully isolate a three-phase circuit, including the neutral conductor — common on larger commercial and industrial distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCBs are hardwired into a live distribution board and must be installed or replaced by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797540020323,"sku":"B001Z3VX02","price":178.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MCN463.webp?v=1786954808"},{"product_id":"abb-mcb-s202m-c16-2-pole-16a-10ka-type-c","title":"ABB MCB S202M-C16 2-Pole 16A 10kA Type C","description":"\u003ch2\u003eABB MCB S202M-C16 2-Pole 16A 10kA Type C\u003c\/h2\u003e\u003cp\u003eThe ABB S202M-C16 is a high-performance 2-pole 16A Type C MCB with 10kA breaking capacity from the ABB S200M series. Its superior fault current breaking performance makes it the right choice for UAE commercial installations where higher fault levels require upgraded MCB protection compared to standard 6kA devices.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2-pole 16A Type C MCB with 10kA breaking capacity\u003c\/li\u003e\n\u003cli\u003eHigher fault withstand than standard 6kA MCBs\u003c\/li\u003e\n\u003cli\u003eType C tripping characteristic for general power circuits\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting for DB and panel installation\u003c\/li\u003e\n\u003cli\u003eGenuine ABB S200M series quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS202M-C16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230\/400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDouble-pole protection for single-phase circuits in commercial DBs\u003c\/li\u003e\n\u003cli\u003eHigh fault-level commercial and light industrial installations\u003c\/li\u003e\n\u003cli\u003eSocket and power circuit protection in commercial buildings\u003c\/li\u003e\n\u003cli\u003eDB incoming and sub-main circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e10kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (2P) breaker switches both live and neutral together, giving full isolation on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140749193315,"sku":"S202M-C16","price":75.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000192138_400x400_be46fd9e-7a43-42b3-b9bd-0d16265b17e1.jpg?v=1786966295"},{"product_id":"abb-mcb-s202-c63-2-pole-63a-6ka-type-c","title":"ABB MCB S202-C63 2-Pole 63A 6kA Type C","description":"\u003ch2\u003eABB MCB S202-C63 2-Pole 63A 6kA Type C\u003c\/h2\u003e\u003cp\u003eThe ABB S202-C63 is a 2-pole 63A Type C MCB with 6kA breaking capacity for protection of high-current single-phase circuits in UAE commercial distribution boards. Its 63A rating makes it suitable for large power circuits, sub-main protection, and DB incoming switches where double-pole switching is required.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2-pole 63A Type C MCB for high-current single-phase circuit protection\u003c\/li\u003e\n\u003cli\u003e6kA breaking capacity for standard UAE commercial installations\u003c\/li\u003e\n\u003cli\u003eType C curve suitable for motor and general power loads\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine ABB S200 series quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS202-C63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e2CDS252001R0634\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230\/400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-current single-phase power circuit protection\u003c\/li\u003e\n\u003cli\u003eDB sub-main and incoming circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial distribution board circuits\u003c\/li\u003e\n\u003cli\u003eAir conditioning and large appliance circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (2P) breaker switches both live and neutral together, giving full isolation on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140749226083,"sku":"2CDS252001R0634","price":75.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000184250_400x400_d0eed1d0-0b55-4fad-9b80-7878fb61bc25.jpg?v=1786966299"},{"product_id":"abb-mcb-s202m-c25-2-pole-25a-10ka-type-c","title":"ABB MCB S202M-C25 2-Pole 25A 10kA Type C","description":"\u003ch2\u003eABB MCB S202M-C25 2-Pole 25A 10kA Type C\u003c\/h2\u003e\u003cp\u003eThe ABB S202M-C25 is a 2-pole 25A Type C MCB with 10kA breaking capacity from the high-performance S200M series. Designed for UAE commercial installations with higher fault current levels, it provides reliable double-pole circuit protection where standard 6kA breaking capacity is insufficient.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2-pole 25A Type C MCB with enhanced 10kA breaking capacity\u003c\/li\u003e\n\u003cli\u003eSuperior fault withstand for high fault-level commercial installations\u003c\/li\u003e\n\u003cli\u003eType C curve for socket, power, and general load circuits\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine ABB S200M high-performance MCB quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS202M-C25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e2CDS272001R0254\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230\/400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDouble-pole protection for power circuits in commercial DBs\u003c\/li\u003e\n\u003cli\u003eHigh fault-level commercial and light industrial MCB protection\u003c\/li\u003e\n\u003cli\u003eSocket ring main and power circuit protection\u003c\/li\u003e\n\u003cli\u003eShower, cooker, and high-load circuit double-pole switching\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e10kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (2P) breaker switches both live and neutral together, giving full isolation on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140749258851,"sku":"2CDS272001R0254","price":59.8,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000185608_400x400_5c6522ae-0887-486b-9664-3053b6ba111a.jpg?v=1786966304"},{"product_id":"abb-mcb-sh203m-c40-3-pole-40a-10ka-type-c","title":"ABB MCB SH203M-C40 3-Pole 40A 10kA Type C","description":"\u003ch2\u003eABB MCB SH203M-C40 3-Pole 40A 10kA Type C\u003c\/h2\u003e\u003cp\u003eThe ABB SH203M-C40 is a 3-pole 40A Type C MCB with 10kA breaking capacity for three-phase circuit protection in UAE commercial and industrial distribution boards. Its 10kA breaking capacity and 40A rating make it suitable for motor feeder and power circuit protection in higher fault-level panel installations.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pole 40A Type C MCB with 10kA breaking capacity\u003c\/li\u003e\n\u003cli\u003eThree-phase circuit protection for motors and power loads\u003c\/li\u003e\n\u003cli\u003e10kA fault withstand for commercial and industrial installations\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting for standard panel installation\u003c\/li\u003e\n\u003cli\u003eGenuine ABB SH200M series quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSH203M-C40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e2CDS273011R0404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThree-phase motor feeder protection in commercial DBs\u003c\/li\u003e\n\u003cli\u003ePower circuit protection in commercial and industrial panels\u003c\/li\u003e\n\u003cli\u003eHVAC and building services three-phase circuit protection\u003c\/li\u003e\n\u003cli\u003eHigh fault-level three-phase MCB applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e10kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 3-pole (3P) breaker switches all three phases on a three-phase circuit without a switched neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140749291619,"sku":"2CDS273011R0404","price":90.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000334536_400x400_3976aa8b-8086-4ab6-9d36-567866a02b4e.png?v=1786966307"},{"product_id":"abb-mcb-sh203-c32-3-pole-32a-6ka-type-c","title":"ABB MCB SH203-C32 3-Pole 32A 6kA Type C","description":"\u003ch2\u003eABB MCB SH203-C32 3-Pole 32A 6kA Type C\u003c\/h2\u003e\u003cp\u003eThe ABB SH203-C32 is a 3-pole 32A Type C MCB with 6kA breaking capacity for protection of three-phase power circuits in UAE commercial and industrial distribution boards. It is a compact, reliable 3-pole MCB for motor feeders, HVAC circuits, and general three-phase power circuit protection.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pole 32A Type C MCB with 6kA breaking capacity\u003c\/li\u003e\n\u003cli\u003eThree-phase circuit protection for power and motor loads\u003c\/li\u003e\n\u003cli\u003eCompact DIN rail design for space-efficient panel installation\u003c\/li\u003e\n\u003cli\u003eType C curve suitable for motor and power circuits\u003c\/li\u003e\n\u003cli\u003eGenuine ABB SH200 series quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSH203-C32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThree-phase motor and power circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial HVAC and building services circuit protection\u003c\/li\u003e\n\u003cli\u003eIndustrial distribution board three-phase circuits\u003c\/li\u003e\n\u003cli\u003eGeneral three-phase load circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 3-pole (3P) breaker switches all three phases on a three-phase circuit without a switched neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140749324387,"sku":"SH203-C32","price":55.25,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000150998_400x400_ae8923f9-0b27-403b-a326-d345c3c61d15.jpg?v=1786966358"},{"product_id":"hager-mcn120-1-pole-20a-mcb-type-c-6ka","title":"Hager MCN120 1-Pole 20A MCB Type C 6kA","description":"\u003ch2\u003eHager MCN120 1-Pole 20A MCB Type C 6kA\u003c\/h2\u003e\u003cp\u003eThe Hager MCN120 is a 1-pole 20A Type C MCB with 6kA breaking capacity for single-phase circuit protection in UAE residential and commercial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1-pole 20A Type C MCB with 6kA breaking capacity\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eCompact design for DB installation\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MCN quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMCN120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230\/400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSingle-phase circuit protection in residential DBs\u003c\/li\u003e\n\u003cli\u003eLighting and power circuit MCB protection\u003c\/li\u003e\n\u003cli\u003eCommercial distribution board circuit protection\u003c\/li\u003e\n\u003cli\u003eGeneral building services circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Type C\" mean on this MCB?\u003c\/strong\u003e\u003cbr\u003eType C describes the tripping curve — it allows a higher inrush current (roughly 5–10 times the rated current) before tripping on short-circuit, which suits motors, transformers, and other inductive loads that draw a brief high current at switch-on without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA rating mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the breaking capacity — the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 1-pole, 20A unit. Use 1-pole for a single live conductor on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — MCBs are installed inside a distribution board on live busbars and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eGenuine Hager MCBs clip directly onto standard 35mm DIN rail and are designed to work across the Hager DB range — check your board's existing MCB range\/series if you need an exact match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163349708899,"sku":"MCN120","price":23.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MCN120.webp?v=1786965569"},{"product_id":"hager-mw210-2-pole-10a-mcb-type-c-6ka","title":"Hager MW210 2-Pole 10A MCB Type C 6kA","description":"\u003ch2\u003eHager MW210 2-Pole 10A MCB Type C 6kA\u003c\/h2\u003e\u003cp\u003eThe Hager MW210 is a 2-pole 10A Type C MCB with 6kA breaking capacity for double-pole circuit protection in UAE residential and commercial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2-pole 10A Type C MCB, 6kA\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MW quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMW210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230\/400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDouble-pole circuit protection in residential and commercial DBs\u003c\/li\u003e\n\u003cli\u003eLighting and small load double-pole switching\u003c\/li\u003e\n\u003cli\u003eConsumer unit and panel circuit protection\u003c\/li\u003e\n\u003cli\u003eGeneral building services circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Type C\" mean on this MCB?\u003c\/strong\u003e\u003cbr\u003eType C describes the tripping curve — it allows a higher inrush current (roughly 5–10 times the rated current) before tripping on short-circuit, which suits motors, transformers, and other inductive loads that draw a brief high current at switch-on without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA rating mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the breaking capacity — the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole, 10A unit. Use 2-pole to switch both live and neutral on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — MCBs are installed inside a distribution board on live busbars and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eGenuine Hager MCBs clip directly onto standard 35mm DIN rail and are designed to work across the Hager DB range — check your board's existing MCB range\/series if you need an exact match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163349774435,"sku":"MW210","price":60.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MW210.webp?v=1786965572"},{"product_id":"hager-mw220-2-pole-20a-mcb-type-c-6ka","title":"Hager MW220 2-Pole 20A MCB Type C 6kA","description":"\u003ch2\u003eHager MW220 2-Pole 20A MCB Type C 6kA\u003c\/h2\u003e\u003cp\u003eThe Hager MW220 is a 2-pole 20A Type C MCB with 6kA breaking capacity for double-pole circuit protection in UAE residential and commercial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2-pole 20A Type C MCB, 6kA\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MW quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMW220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230\/400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDouble-pole socket and power circuit protection\u003c\/li\u003e\n\u003cli\u003eResidential and commercial DB circuit protection\u003c\/li\u003e\n\u003cli\u003eAppliance and high-load double-pole switching\u003c\/li\u003e\n\u003cli\u003eGeneral building circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Type C\" mean on this MCB?\u003c\/strong\u003e\u003cbr\u003eType C describes the tripping curve — it allows a higher inrush current (roughly 5–10 times the rated current) before tripping on short-circuit, which suits motors, transformers, and other inductive loads that draw a brief high current at switch-on without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA rating mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the breaking capacity — the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole, 20A unit. Use 2-pole to switch both live and neutral on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — MCBs are installed inside a distribution board on live busbars and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eGenuine Hager MCBs clip directly onto standard 35mm DIN rail and are designed to work across the Hager DB range — check your board's existing MCB range\/series if you need an exact match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163349807203,"sku":"MW220","price":60.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MW220_1.webp?v=1786965573"},{"product_id":"hager-mw232-2-pole-32a-mcb-type-c-6ka","title":"Hager MW232 2-Pole 32A MCB Type C 6kA","description":"\u003ch2\u003eHager MW232 2-Pole 32A MCB Type C 6kA\u003c\/h2\u003e\u003cp\u003eThe Hager MW232 is a 2-pole 32A Type C MCB with 6kA breaking capacity for high-current double-pole circuit protection in UAE residential and commercial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2-pole 32A Type C MCB, 6kA\u003c\/li\u003e\n\u003cli\u003eDouble-pole protection for high-load circuits\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MW quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMW232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230\/400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-load double-pole circuit protection\u003c\/li\u003e\n\u003cli\u003eCooker, shower, and appliance circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial DB sub-main protection\u003c\/li\u003e\n\u003cli\u003eGeneral high-current circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Type C\" mean on this MCB?\u003c\/strong\u003e\u003cbr\u003eType C describes the tripping curve — it allows a higher inrush current (roughly 5–10 times the rated current) before tripping on short-circuit, which suits motors, transformers, and other inductive loads that draw a brief high current at switch-on without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA rating mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the breaking capacity — the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole, 32A unit. Use 2-pole to switch both live and neutral on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — MCBs are installed inside a distribution board on live busbars and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eGenuine Hager MCBs clip directly onto standard 35mm DIN rail and are designed to work across the Hager DB range — check your board's existing MCB range\/series if you need an exact match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163349839971,"sku":"MW232","price":60.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MW232.webp?v=1786965575"},{"product_id":"hager-mcn210-2-pole-10a-mcb-type-c-6ka","title":"Hager MCN210 2-Pole 10A MCB Type C 6kA","description":"\u003ch2\u003eHager MCN210 2-Pole 10A MCB Type C 6kA\u003c\/h2\u003e\u003cp\u003eThe Hager MCN210 is a 2-pole 10A Type C MCB with 6kA breaking capacity for double-pole lighting and circuit protection in UAE residential and commercial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2-pole 10A Type C MCB, 6kA\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MCN quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMCN210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230\/400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDouble-pole lighting and circuit protection\u003c\/li\u003e\n\u003cli\u003eResidential and commercial DB circuit protection\u003c\/li\u003e\n\u003cli\u003eConsumer unit and panel protection\u003c\/li\u003e\n\u003cli\u003eGeneral building services circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Type C\" mean on this MCB?\u003c\/strong\u003e\u003cbr\u003eType C describes the tripping curve — it allows a higher inrush current (roughly 5–10 times the rated current) before tripping on short-circuit, which suits motors, transformers, and other inductive loads that draw a brief high current at switch-on without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA rating mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the breaking capacity — the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole, 10A unit. Use 2-pole to switch both live and neutral on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — MCBs are installed inside a distribution board on live busbars and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eGenuine Hager MCBs clip directly onto standard 35mm DIN rail and are designed to work across the Hager DB range — check your board's existing MCB range\/series if you need an exact match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163349872739,"sku":"MCN210","price":60.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MCN210.webp?v=1786965577"},{"product_id":"hager-mcn232-2-pole-32a-mcb-type-c-6ka","title":"Hager MCN232 2-Pole 32A MCB Type C 6kA","description":"\u003ch2\u003eHager MCN232 2-Pole 32A MCB Type C 6kA\u003c\/h2\u003e\u003cp\u003eThe Hager MCN232 is a 2-pole 32A Type C MCB with 6kA breaking capacity for high-current double-pole circuit protection in UAE residential and commercial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2-pole 32A Type C MCB, 6kA\u003c\/li\u003e\n\u003cli\u003eHigh-current double-pole protection\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MCN quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMCN232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230\/400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-current double-pole circuit protection\u003c\/li\u003e\n\u003cli\u003eCooker and appliance circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial DB sub-main MCB protection\u003c\/li\u003e\n\u003cli\u003eGeneral high-current circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Type C\" mean on this MCB?\u003c\/strong\u003e\u003cbr\u003eType C describes the tripping curve — it allows a higher inrush current (roughly 5–10 times the rated current) before tripping on short-circuit, which suits motors, transformers, and other inductive loads that draw a brief high current at switch-on without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA rating mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the breaking capacity — the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole, 32A unit. Use 2-pole to switch both live and neutral on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — MCBs are installed inside a distribution board on live busbars and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eGenuine Hager MCBs clip directly onto standard 35mm DIN rail and are designed to work across the Hager DB range — check your board's existing MCB range\/series if you need an exact match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163349938275,"sku":"MCN232","price":60.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_71dc7150-bd5d-4b4b-bc94-5582955f39aa.webp?v=1786965577"},{"product_id":"hager-mw340-3-pole-40a-mcb-type-c-6ka","title":"Hager MW340 3-Pole 40A MCB Type C 6kA","description":"\u003ch2\u003eHager MW340 3-Pole 40A MCB Type C 6kA\u003c\/h2\u003e\u003cp\u003eThe Hager MW340 is a 3-pole 40A Type C MCB with 6kA breaking capacity for three-phase motor and power circuit protection in UAE commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pole 40A Type C MCB, 6kA for three-phase circuit protection\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MW quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMW340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThree-phase motor feeder circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial DB three-phase circuits\u003c\/li\u003e\n\u003cli\u003eHVAC and building services three-phase protection\u003c\/li\u003e\n\u003cli\u003eGeneral three-phase power circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Type C\" mean on this MCB?\u003c\/strong\u003e\u003cbr\u003eType C describes the tripping curve — it allows a higher inrush current (roughly 5–10 times the rated current) before tripping on short-circuit, which suits motors, transformers, and other inductive loads that draw a brief high current at switch-on without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA rating mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the breaking capacity — the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole, 40A unit. Use 3 or 4 poles for a three-phase circuit, with 4-pole also switching neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — MCBs are installed inside a distribution board on live busbars and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eGenuine Hager MCBs clip directly onto standard 35mm DIN rail and are designed to work across the Hager DB range — check your board's existing MCB range\/series if you need an exact match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163350364259,"sku":"MW340","price":60.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MW340.webp?v=1786965578"},{"product_id":"hager-mu325a-3-pole-25a-mcb-type-c-6ka","title":"Hager 3-Pole 25A MCB Type C 6kA MU325A","description":"\u003ch2\u003eHager MU325A 3-Pole 25A MCB Type C 6kA\u003c\/h2\u003e\u003cp\u003eThe Hager MU325A is a 3-pole 25A Type C MCB with 6kA breaking capacity for three-phase circuit protection in UAE commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pole 25A Type C MCB, 6kA\u003c\/li\u003e\n\u003cli\u003eThree-phase motor and power circuit protection\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MU quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMU325A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThree-phase motor feeder and power circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial distribution boards\u003c\/li\u003e\n\u003cli\u003eHVAC and building services three-phase circuits\u003c\/li\u003e\n\u003cli\u003eGeneral three-phase MCB protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Type C\" mean on this MCB?\u003c\/strong\u003e\u003cbr\u003eType C describes the tripping curve — it allows a higher inrush current (roughly 5–10 times the rated current) before tripping on short-circuit, which suits motors, transformers, and other inductive loads that draw a brief high current at switch-on without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA rating mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the breaking capacity — the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole, 25A unit. Use 3 or 4 poles for a three-phase circuit, with 4-pole also switching neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — MCBs are installed inside a distribution board on live busbars and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eGenuine Hager MCBs clip directly onto standard 35mm DIN rail and are designed to work across the Hager DB range — check your board's existing MCB range\/series if you need an exact match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163350397027,"sku":"MU325A","price":85.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MU325A_1.webp?v=1786965580"},{"product_id":"hager-mcn363-3-pole-63a-mcb-type-c-6ka","title":"Hager MCN363 3-Pole 63A MCB Type C 6kA","description":"\u003ch2\u003eHager MCN363 3-Pole 63A MCB Type C 6kA\u003c\/h2\u003e\u003cp\u003eThe Hager MCN363 is a 3-pole 63A Type C MCB with 6kA breaking capacity for high-current three-phase sub-main and incoming circuit protection in UAE commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pole 63A high-current MCB with 6kA breaking capacity\u003c\/li\u003e\n\u003cli\u003eThree-phase sub-main and incoming protection\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MCN quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMCN363\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThree-phase sub-main and incoming circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial distribution boards\u003c\/li\u003e\n\u003cli\u003eLarge HVAC and building services circuit protection\u003c\/li\u003e\n\u003cli\u003ePanel incoming and sub-main MCB\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Type C\" mean on this MCB?\u003c\/strong\u003e\u003cbr\u003eType C describes the tripping curve — it allows a higher inrush current (roughly 5–10 times the rated current) before tripping on short-circuit, which suits motors, transformers, and other inductive loads that draw a brief high current at switch-on without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA rating mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the breaking capacity — the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole, 63A unit. Use 3 or 4 poles for a three-phase circuit, with 4-pole also switching neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — MCBs are installed inside a distribution board on live busbars and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eGenuine Hager MCBs clip directly onto standard 35mm DIN rail and are designed to work across the Hager DB range — check your board's existing MCB range\/series if you need an exact match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163350429795,"sku":"MCN363","price":90.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MCN363.webp?v=1786965581"},{"product_id":"hager-mu463a-4-pole-63a-mcb-type-c-6ka","title":"Hager MU463A 4-Pole 63A MCB Type C 6kA","description":"\u003ch2\u003eHager MU463A 4-Pole 63A MCB Type C 6kA\u003c\/h2\u003e\u003cp\u003eThe Hager MU463A is a 4-pole 63A Type C MCB with 6kA breaking capacity for three-phase + neutral high-current incoming and sub-main circuit protection in UAE commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4-pole 63A MCB for three-phase + neutral circuit protection\u003c\/li\u003e\n\u003cli\u003eType C, 6kA breaking capacity\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MU quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMU463A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFour-pole three-phase + neutral incoming circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial DB sub-main MCB\u003c\/li\u003e\n\u003cli\u003eHVAC and building services distribution\u003c\/li\u003e\n\u003cli\u003ePanel incoming and sub-main four-pole protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Type C\" mean on this MCB?\u003c\/strong\u003e\u003cbr\u003eType C describes the tripping curve — it allows a higher inrush current (roughly 5–10 times the rated current) before tripping on short-circuit, which suits motors, transformers, and other inductive loads that draw a brief high current at switch-on without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA rating mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the breaking capacity — the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 4-pole, 63A unit. Use 3 or 4 poles for a three-phase circuit, with 4-pole also switching neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — MCBs are installed inside a distribution board on live busbars and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eGenuine Hager MCBs clip directly onto standard 35mm DIN rail and are designed to work across the Hager DB range — check your board's existing MCB range\/series if you need an exact match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163350462563,"sku":"MU463A","price":185.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MU463A.webp?v=1786965583"},{"product_id":"abb-sh201-c10-1-pole-10a-6ka-type-c-mcb","title":"ABB 10A 6kA Single Pole MCB, SH201-C10 2CDS211001R0104","description":"\u003ch2\u003eABB SH201-C10 1-Pole 10A 6kA Type C MCB\u003c\/h2\u003e\n\u003cp\u003eThe ABB SH201-C10 is a 1-pole 10A Type C miniature circuit breaker with 6kA breaking capacity from the ABB SH200 series. Current-limiting and current-compliant with IEC\/EN 60898-1, it is designed for protection of single-phase circuits in residential and light commercial distribution boards, making it well suited to lighting and power circuit protection in UAE building installations.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1-pole 10A Type C MCB for single-phase lighting and power circuit protection\u003c\/li\u003e\n  \u003cli\u003e6kA breaking capacity for standard UAE residential and commercial installation fault levels\u003c\/li\u003e\n  \u003cli\u003eDual tripping mechanism — delayed thermal for overload and electromechanic for short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eCompact single-module DIN rail mounting compliant with TH35 rail standards for distribution board installation\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB SH200 series quality — consistent performance and reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSH201-C10\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail (TH35-15 \/ TH35-7.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (IP40 with cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eElectrical\/Mechanical Endurance\u003c\/td\u003e\n\u003ctd\u003e20,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 60898-1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.102 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e17.5 mm (1 modular space)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSingle-phase lighting circuit protection in residential DBs\u003c\/li\u003e\n  \u003cli\u003ePower and socket circuit protection in commercial distribution boards\u003c\/li\u003e\n  \u003cli\u003eGeneral building services circuit protection in UAE installations\u003c\/li\u003e\n  \u003cli\u003eConsumer unit and distribution board MCB replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44344540561507,"sku":"SH201-C10","price":14.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000150962_400x400_49809951-ee9e-4f8d-8c2c-8c7f2588b861.jpg?v=1787498346"},{"product_id":"abb-s203-c32-3-pole-32a-6ka-type-c-mcb","title":"ABB MCB Miniature Circuit Breaker 32A 3P S203-C32","description":"\u003ch2\u003eABB S203-C32 3-Pole 32A 6kA Type C MCB\u003c\/h2\u003e\n\u003cp\u003eThe ABB S203-C32 is a 3-pole, 32A Type C miniature circuit breaker with 6kA breaking capacity from the ABB System pro M compact S200 series. Combining a delayed thermal tripping mechanism for overload protection with an electromechanical mechanism for short circuit protection, it is current limiting and suited to three-phase circuit protection across residential, commercial and industrial UAE installations.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3-pole 32A Type C MCB for three-phase circuit protection in distribution boards\u003c\/li\u003e\n  \u003cli\u003e6kA breaking capacity matching standard UAE commercial and industrial fault levels\u003c\/li\u003e\n  \u003cli\u003eType C tripping characteristic suitable for resistive and lightly inductive loads\u003c\/li\u003e\n  \u003cli\u003eBottom-fitting auxiliary contact compatibility, saving up to 50% panel space compared to side-mounted accessories\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB S200 series quality — consistent performance and reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS203-C32\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Short-Circuit Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA (AC\/DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Ultimate Breaking Capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e20kA (230V) \/ 10kA (400V)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e400V AC (IEC 60898-1) \/ 440V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail (TH35-15 \/ TH35-7.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (IP40 with enclosure\/cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMechanical Endurance\u003c\/td\u003e\n\u003ctd\u003e20,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThree-phase circuit protection in commercial and industrial distribution boards\u003c\/li\u003e\n  \u003cli\u003eMotor and power circuit protection in UAE building services installations\u003c\/li\u003e\n  \u003cli\u003eDistribution board upgrades and replacements for three-phase load protection\u003c\/li\u003e\n  \u003cli\u003eGeneral building services circuit protection across residential, commercial and industrial UAE projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 3-pole (3P) breaker switches all three phases on a three-phase circuit without a switched neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44346501169251,"sku":"S203-C32","price":65.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000003062_400x400_8d63cc3c-0ac3-4963-9ebc-ce68f40d5884.png?v=1787498873"},{"product_id":"abb-s202-c6-2-pole-6a-6ka-type-c-mcb","title":"ABB MCB S202 - 2P - 25A 10kA S202-C6","description":"\u003ch2\u003eABB S202-C6 2-Pole 6A 6kA Type C MCB\u003c\/h2\u003e\n\u003cp\u003eThe ABB S202-C6 is a 2-pole, 6A Type C miniature circuit breaker with 6kA breaking capacity from the ABB System pro M compact S200 series. Combining a delayed thermal tripping mechanism for overload protection with an electromechanical mechanism for short circuit protection, it is current limiting and suited to protecting low-current control and lighting circuits across residential, commercial and industrial UAE installations.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e2-pole 6A Type C MCB for low-current circuit protection in distribution boards\u003c\/li\u003e\n  \u003cli\u003e6kA breaking capacity matching standard UAE residential and commercial fault levels\u003c\/li\u003e\n  \u003cli\u003eType C tripping characteristic suitable for resistive and lightly inductive loads\u003c\/li\u003e\n  \u003cli\u003eBottom-fitting auxiliary contact compatibility, saving up to 50% panel space compared to side-mounted accessories\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB S200 series quality — consistent performance and reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS202-C6\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Short-Circuit Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA (AC\/DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Ultimate Breaking Capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e20kA (230V) \/ 10kA (400V)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e400V AC (IEC 60898-1) \/ 440V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail (TH35-15 \/ TH35-7.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (IP40 with enclosure\/cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMechanical Endurance\u003c\/td\u003e\n\u003ctd\u003e20,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.224 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLow-current lighting and control circuit protection in commercial distribution boards\u003c\/li\u003e\n  \u003cli\u003eSmall appliance and single-phase equipment circuit protection in UAE installations\u003c\/li\u003e\n  \u003cli\u003eControl panel circuit protection for automation and BMS systems\u003c\/li\u003e\n  \u003cli\u003eDistribution board circuit protection where a low-rated 2-pole breaker is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e10kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (2P) breaker switches both live and neutral together, giving full isolation on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44346846675043,"sku":"2CDS252001R0064","price":54.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000010010_400x400_af8cc8d0-ba7f-41ac-81c3-509d3867c872.png?v=1787498873"},{"product_id":"abb-s202-c25-2-pole-25a-6ka-type-c-mcb","title":"ABB MCB S200 - 2P - 25A 6kA S202-C25","description":"\u003ch2\u003eABB S202-C25 2-Pole 25A 6kA Type C MCB\u003c\/h2\u003e\n\u003cp\u003eThe ABB S202-C25 is a 2-pole, 25A Type C miniature circuit breaker with 6kA breaking capacity from the ABB System pro M compact S200 series. Combining a delayed thermal tripping mechanism for overload protection with an electromechanical mechanism for short circuit protection, it is current limiting and suited to single-phase and split load circuit protection across residential, commercial and industrial UAE installations.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e2-pole 25A Type C MCB for single-phase circuit protection requiring double-pole isolation\u003c\/li\u003e\n  \u003cli\u003e6kA breaking capacity matching standard UAE residential and commercial fault levels\u003c\/li\u003e\n  \u003cli\u003eType C tripping characteristic suitable for resistive and lightly inductive loads\u003c\/li\u003e\n  \u003cli\u003eBottom-fitting auxiliary contact compatibility, saving up to 50% panel space compared to side-mounted accessories\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB S200 series quality — consistent performance and reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS202-C25\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Short-Circuit Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA (AC\/DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Ultimate Breaking Capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e20kA (230V) \/ 10kA (400V)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e400V AC (IEC 60898-1) \/ 440V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail (TH35-15 \/ TH35-7.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (IP40 with enclosure\/cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMechanical Endurance\u003c\/td\u003e\n\u003ctd\u003e20,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSingle-phase power circuit protection requiring double-pole isolation in distribution boards\u003c\/li\u003e\n  \u003cli\u003eWater heater, AC unit, and appliance circuit protection in UAE residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eSplit-phase load protection in villa and apartment consumer units\u003c\/li\u003e\n  \u003cli\u003eDistribution board upgrades requiring reliable 2-pole circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (2P) breaker switches both live and neutral together, giving full isolation on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44346853589091,"sku":"2CDS252001R0254","price":54.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000008755_400x400_484d3015-ec3f-4c4a-afb2-6091c03f4697.png?v=1787498877"},{"product_id":"abb-sh201-c40-1-pole-40a-6ka-type-c-mcb","title":"ABB SH201-C40 MCB, 1 Pole, 40 Amp 2CDS211001R0404","description":"\u003ch2\u003eABB SH201-C40 1-Pole 40A 6kA Type C MCB\u003c\/h2\u003e\n\u003cp\u003eThe SH201-C40 is a 1-pole 40A Type C miniature circuit breaker with 6kA breaking capacity from the ABB SH200 Compact Home series. Combining a delayed thermal tripping mechanism for overload protection with an electromechanical mechanism for short-circuit protection, it is a reliable, current-limiting choice for higher-current single-phase circuits in UAE residential and light commercial distribution boards.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1-pole 40A Type C MCB suitable for single-phase circuits with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003e6kA breaking capacity at 230\/400V AC for standard UAE residential and commercial fault levels\u003c\/li\u003e\n  \u003cli\u003eDual tripping mechanism — delayed thermal for overload, electromechanical for short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eCurrent-limiting design complying with IEC\/EN 60898-1 for residential applications\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB SH200 series quality — consistent performance and reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSH201-C40\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigher-current single-phase circuit protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eSub-main and feeder circuit protection in villas and apartments across the UAE\u003c\/li\u003e\n  \u003cli\u003eGeneral power circuit protection for appliances and equipment requiring 40A capacity\u003c\/li\u003e\n  \u003cli\u003eConsumer unit and distribution board MCB replacement or upgrade\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 1-pole (1P) breaker switches the line conductor only — the standard choice for individual single-phase final circuits (lighting, sockets).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44358452543587,"sku":"SH201-C40","price":14.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000245987_400x400_4739d450-7ee0-4731-9459-1cad995ee81a.jpg?v=1787498372"},{"product_id":"abb-sh201-c6-1-pole-6a-6ka-type-c-mcb","title":"ABB SH201-C6 1-Pole 6A 6kA Type C MCB","description":"\u003cp\u003eThe SH201-C6 is a 1-pole 6A Type C miniature circuit breaker with 6kA breaking capacity from the ABB SH200 Compact Home series. Combining a delayed thermal tripping mechanism for overload protection with an electromechanical mechanism for short-circuit protection, it is a current-limiting choice for low-current lighting and control circuits in UAE residential and commercial distribution boards.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1-pole 6A Type C MCB suited to low-current lighting and control circuit protection\u003c\/li\u003e\n\u003cli\u003e6kA breaking capacity at 230\/400V AC for standard UAE residential and commercial fault levels\u003c\/li\u003e\n\u003cli\u003eDual tripping mechanism — delayed thermal for overload, electromechanical for short-circuit protection\u003c\/li\u003e\n\u003cli\u003eCurrent-limiting design complying with IEC\/EN 60898-1 for residential applications\u003c\/li\u003e\n\u003cli\u003eGenuine ABB SH200 series quality — consistent performance and reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSH201-C6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow-current lighting circuit protection in residential and commercial distribution boards\u003c\/li\u003e\n\u003cli\u003eControl and signaling circuit protection in panel builds across the UAE\u003c\/li\u003e\n\u003cli\u003eSmall appliance and low-load circuit protection in consumer units\u003c\/li\u003e\n\u003cli\u003eDistribution board MCB replacement for lighting sub-circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast\/LED-driver inrush without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 1-pole (1P) breaker switches the line conductor only — the standard choice for individual single-phase final circuits (lighting, sockets).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44358651773027,"sku":"SH201-C6","price":13.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000003515_400x400_e3bc87c0-0c15-4906-bb13-1d55832ad78a.png?v=1787498893"},{"product_id":"abb-sh201-c20-1-pole-20a-6ka-type-c-mcb","title":"ABB MCB 20A 6Ka Single Pole Breaker S201M-C20","description":"\u003ch2\u003eABB SH201-C20 1-Pole 20A 6kA Type C MCB\u003c\/h2\u003e\n\u003cp\u003eThe SH201-C20 is a 1-pole 20A Type C miniature circuit breaker with 6kA breaking capacity from the ABB SH200 Compact Home series. Combining a delayed thermal tripping mechanism for overload protection with an electromechanical mechanism for short-circuit protection, it is a current-limiting choice for general lighting and power circuits in UAE residential and commercial distribution boards.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1-pole 20A Type C MCB suitable for general lighting and power circuit protection\u003c\/li\u003e\n  \u003cli\u003e6kA breaking capacity at 230\/400V AC for standard UAE residential and commercial fault levels\u003c\/li\u003e\n  \u003cli\u003eDual tripping mechanism — delayed thermal for overload, electromechanical for short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eCurrent-limiting design complying with IEC\/EN 60898-1 for residential applications\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB SH200 series quality — consistent performance and reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSH201-C20\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGeneral lighting and power circuit protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eSocket outlet circuit protection in commercial and residential installations across the UAE\u003c\/li\u003e\n  \u003cli\u003eSmall to medium appliance circuit protection in consumer units\u003c\/li\u003e\n  \u003cli\u003eDistribution board MCB replacement for standard lighting and power sub-circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44358816661603,"sku":"SH201-C20","price":14.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000245984_400x400_5f94ce7c-a889-4534-a5b3-92ae8bd8b583.jpg?v=1787498377"},{"product_id":"abb-s203-c100-3-pole-100a-6ka-type-c-mcb","title":"Abb Miniature Circuit Breaker 100A 3P 6kA S203-C100","description":"\u003ch2\u003eABB S203-C100 3-Pole 100A 6kA Type C MCB\u003c\/h2\u003e\n\u003cp\u003eThe ABB S203-C100 is a 3-pole 100A Type C miniature circuit breaker with 6kA breaking capacity from the ABB S200 series. Rated for 400V AC operation and built to withstand ambient temperatures from -25°C to +55°C, it is well suited for three-phase circuit protection in UAE distribution boards where reliable performance in high-heat environments is essential.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3-pole 100A Type C MCB for three-phase distribution circuit protection\u003c\/li\u003e\n  \u003cli\u003e6kA breaking capacity at 400V AC, with a rated conditional short-circuit current of 20kA at 400V\u003c\/li\u003e\n  \u003cli\u003eType C tripping characteristic suitable for circuits with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eRated for continuous operation across a wide -25°C to +55°C ambient temperature range, suitable for UAE climate conditions\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB S200 series quality — consistent performance and reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS203-C100\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Icu, 400V AC)\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current (Inc, 400V)\u003c\/td\u003e\n\u003ctd\u003e20kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail (TH35-15 \/ TH35-7.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (IP40 with cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 60898-1, IEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThree-phase distribution circuit protection in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eMain and sub-main protection in DIN rail distribution boards\u003c\/li\u003e\n  \u003cli\u003eMotor and general power circuit protection in UAE panel installations\u003c\/li\u003e\n  \u003cli\u003eDistribution board upgrades requiring compact 3-pole 100A protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB\/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA breaking capacity mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 3-pole (3P) breaker switches all three phases on a three-phase circuit without a switched neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other ABB DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44364328337507,"sku":"2CDS253001R0824","price":348.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000088367_400x400_b6796ce0-a64d-429a-8e2c-83ce39d7b021.jpg?v=1787498381"}],"url":"https:\/\/www.deluxeuae.com\/collections\/mcbs.oembed?page=3","provider":"Deluxe Electricals","version":"1.0","type":"link"}