{"title":"Hager","description":"\u003cp\u003eHager is a German-founded switchgear maker whose modular devices are common in UAE distribution boards. The 52 items here lean heavily towards earth-leakage protection — roughly half the page is RCCBs — alongside Type C MCBs, HHA moulded-case breakers, modular isolators, installation contactors and DIN-rail time switches.\u003c\/p\u003e\u003ch2\u003eHow do I read a Hager RCCB code?\u003c\/h2\u003e\u003cp\u003eThe catalogue numbers are systematic once the pattern is clear. Across the C-series RCCBs the second letter tracks sensitivity: \u003cstrong\u003eCD\u003c\/strong\u003e is 30mA, \u003cstrong\u003eCE\u003c\/strong\u003e is 100mA and \u003cstrong\u003eCF\u003c\/strong\u003e is 300mA. So CDC441J is a 40A four-pole 30mA device and CFC264J is a 63A two-pole 300mA one. When replacing like for like, match the full code on the existing unit, not the amperage alone: a 100mA device occupies the same space as a 30mA one and behaves very differently.\u003c\/p\u003e\u003ch2\u003eOnekonekt or the older C-series?\u003c\/h2\u003e\u003cp\u003eOnekonekt is Hager's newer modular platform, represented here by RCCBs including CCC217J at 10mA, CDC226J, CEC226J and CEC426J, plus the SBN464N 63A four-pole main switch. The longer-running C-series, listed as made in France, covers the heavier end with 100A two- and four-pole RCCBs. Mixing platforms in one board comes down to busbar and terminal compatibility, so check what the existing board is built around.\u003c\/p\u003e\u003ch2\u003eWhat else on this page mounts on the rail?\u003c\/h2\u003e\u003cp\u003eMCN, MW and MU series MCBs in one to four poles, the HLF390S 100A 10kA three-pole, JG and SBN modular isolators from 32A to 90A, ESC installation contactors from 25A to 63A for lighting and pump duty, and EHN daily and weekly time switches.\u003c\/p\u003e\u003cp\u003eDevice selection and any change inside a live board is work for a licensed electrician. Photograph your board and we will identify the replacements.\u003c\/p\u003e","products":[{"product_id":"hager-miniature-circuit-breaker-1p-made-in-france","title":"Hager MCB 1-Pole 6kA Type C Range — Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager MCB 1-Pole 6kA Type C Range — Made in France\u003c\/h2\u003e\n\u003cp\u003eThe Hager 1-Pole MCB range delivers dependable overcurrent protection for 230V circuits, Made in France and available across the full 6A-63A rating band from a single Hager product family (MCN106, MCN110A, MCN116, MCN120, MCN125, MCN132, MCN140, MCN150, MCN163). With a 6kA breaking capacity and Type C tripping curve, it suits residential consumer units and commercial distribution boards where a compact, single-module DIN-rail breaker is needed for lighting, socket, and general power circuits.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e9 current ratings in one range: 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A\u003c\/li\u003e\n\u003cli\u003e1-pole (1P), single-module (17.5mm) construction across every rating in the range\u003c\/li\u003e\n\u003cli\u003e6kA rated breaking capacity (Icn) to IEC 60898-1\u003c\/li\u003e\n\u003cli\u003eType C tripping curve — suited to circuits with moderate inrush current\u003c\/li\u003e\n\u003cli\u003eRated operating voltage 240-415V AC, 50-60Hz\u003c\/li\u003e\n\u003cli\u003eIP20 enclosure rating with -25°C to +70°C operating range\u003c\/li\u003e\n\u003cli\u003eScrew-terminal DIN-rail mounting (EN 60715) for fast panel installation\u003c\/li\u003e\n\u003cli\u003eMade in France to Hager's standard build quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eMCN1 Series — 1-Pole 6kA Type C MCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1 (Single Pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Ratings\u003c\/td\u003e\n\u003ctd\u003e6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Icn)\u003c\/td\u003e\n\u003ctd\u003e6 kA per IEC 60898-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Curve\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e240 - 415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 - 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V (4,000 V impulse withstand)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Width\u003c\/td\u003e\n\u003ctd\u003e1 module (17.5 mm) — same across all ratings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 60898-1, IEC 60947-2, IEC 60664\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in France\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential mains distribution and consumer units\u003c\/li\u003e\n\u003cli\u003eCommercial lighting, socket, and small power circuits\u003c\/li\u003e\n\u003cli\u003eCircuits with moderate inrush loads (motors, ballasts, transformers) suited to a Type C curve\u003c\/li\u003e\n\u003cli\u003eExpanding or retrofitting existing Hager DIN-rail distribution boards across the UAE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich rating (6A-63A) do I need for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe correct rating depends on the connected load and the cable's current-carrying capacity — an undersized breaker will nuisance-trip, an oversized one won't protect the cable. Always size the MCB to the circuit design, not just the appliance rating; a licensed electrician can confirm the correct choice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean?\u003c\/strong\u003e\u003cbr\u003eType C breakers trip instantaneously at roughly 5-10 times their rated current, giving them enough headroom to ride out the brief inrush of motors, transformers, and fluorescent\/LED lighting ballasts without nuisance tripping, while still tripping fast on a genuine fault.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other Hager DIN-rail distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes. It's a standard 1-module, DIN-rail (EN 60715) mounted breaker and clips directly into Hager's modular consumer units and distribution boards alongside other Hager DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need for a single-phase circuit?\u003c\/strong\u003e\u003cbr\u003eA single 1-pole (1P) breaker switches the line conductor only, which is the standard choice for individual single-phase final circuits (lighting, sockets). Where full double-pole isolation is required, a 2-pole device is used instead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"6A","offer_id":41559032954979,"sku":"MCN106","price":17.0,"currency_code":"AED","in_stock":true},{"title":"10A","offer_id":41559032987747,"sku":"MCN110A","price":17.0,"currency_code":"AED","in_stock":true},{"title":"16A","offer_id":41549413253219,"sku":"MCN116","price":17.0,"currency_code":"AED","in_stock":true},{"title":"20A","offer_id":41549413285987,"sku":"MCN120","price":23.0,"currency_code":"AED","in_stock":true},{"title":"25A","offer_id":41559033020515,"sku":"MCN125","price":17.0,"currency_code":"AED","in_stock":true},{"title":"32A","offer_id":41559033053283,"sku":"MCN132","price":17.0,"currency_code":"AED","in_stock":true},{"title":"40A","offer_id":41559033086051,"sku":"MCN140","price":17.0,"currency_code":"AED","in_stock":true},{"title":"50A","offer_id":41559033118819,"sku":"MCN150","price":17.0,"currency_code":"AED","in_stock":true},{"title":"63A","offer_id":41559033151587,"sku":"MCN163","price":17.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/hager-mcbs-6a-hager-miniature-circuit-breaker-mcb-1-pole-made-in-france-31538397282403.jpg?v=1787498087"},{"product_id":"hager-rccb-40a-4p-30ma-cdc441j","title":"Hager CDC441J RCCB 40A 4-Pole 30mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CDC441J RCCB 40A 4-Pole 30mA Type AC — ELCB\u003c\/h2\u003e\n\u003cp\u003eThe Hager CDC441J is a 40A, 4-pole residual current circuit breaker (RCCB\/ELCB) with 30mA Type AC sensitivity, made in France for reliable earth-leakage protection in UAE residential, commercial, and light industrial distribution boards. Its 30mA rating is calibrated for personnel protection, tripping fast enough to prevent electric shock on final circuits.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated current: 40A, 4-pole (3P+N) configuration\u003c\/li\u003e\n\u003cli\u003e30mA Type AC sensitivity — personnel protection level\u003c\/li\u003e\n\u003cli\u003eRated voltage: 240–415V AC, 50Hz\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Idm): 1.50kA; conditional short-circuit current (Inc): 6kA per EN 61008-1\u003c\/li\u003e\n\u003cli\u003eIP20 protection rating, compact 4-module DIN rail width\u003c\/li\u003e\n\u003cli\u003eScrew terminals (top) and biconnect terminals (bottom); 1–25mm² rigid \/ 1–16mm² flexible conductor capacity\u003c\/li\u003e\n\u003cli\u003eRated for 4,000 mechanical and 2,000 electrical operating cycles\u003c\/li\u003e\n\u003cli\u003eMade in France by Hager, compliant with IEC\/EN safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCDC441J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P (3P+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity (Idn)\u003c\/td\u003e\n\u003ctd\u003e30 mA, Type AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage (Ue)\u003c\/td\u003e\n\u003ctd\u003e240–415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Idm)\u003c\/td\u003e\n\u003ctd\u003e1.50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConditional Short-Circuit Current (Inc)\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail, 4 modules (70 mm width)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd\u003e1–25 mm² rigid \/ 1–16 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndurance\u003c\/td\u003e\n\u003ctd\u003e4,000 mechanical \/ 2,000 electrical cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential villas and apartments\u003c\/li\u003e\n\u003cli\u003eCommercial offices, schools, hospitals, and retail outlets\u003c\/li\u003e\n\u003cli\u003eLight industrial distribution boards\u003c\/li\u003e\n\u003cli\u003eCircuits requiring 30mA high-sensitivity personnel protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects a circuit from overload and short-circuit current. An RCCB\/RCD like the CDC441J monitors for earth leakage current and trips to prevent electric shock — it does not provide overload protection. The two are typically installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e30mA is the personnel-protection threshold: the CDC441J trips if it detects 30mA or more of current leaking to earth, fast enough to prevent dangerous electric shock. This makes it suitable for final circuits such as socket outlets and bathrooms, unlike higher-mA (100\/300mA) devices, which are used mainly for fire and equipment protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThe CDC441J is a 4-pole (3P+N) device for three-phase supplies with neutral, protecting all three phases and the neutral conductor. Use a 2-pole RCCB for single-phase circuits instead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution-board component that must be installed and commissioned by a licensed electrician in accordance with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41549417840739,"sku":"CDC441J","price":126.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CDC441J.webp?v=1786954814"},{"product_id":"hager-32a-3p-mcb-type-c-mcn332","title":"Hager MCN332 MCB 32A 3-Pole 6kA Type C — Made in France","description":"\u003cdiv\u003e\n\u003cp\u003eThe Hager MCN332 MCB is a 32A, 3-pole miniature circuit breaker designed to protect circuits from overloads and short circuits. With a 6kA breaking capacity and Type C tripping curve, it is suited for residential, commercial, and light industrial panels. Compact, durable, and easy to integrate into distribution boards, it’s a reliable choice for UAE installations.\u003c\/p\u003e \u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e32A rated current, 3P (three-pole) configuration\u003c\/li\u003e \u003cli\u003e6kA breaking capacity for reliable fault interruption\u003c\/li\u003e \u003cli\u003eType C tripping curve for moderate inrush protection\u003c\/li\u003e \u003cli\u003eCompact, durable design with long service life\u003c\/li\u003e \u003cli\u003eIEC safety standards compliant\u003c\/li\u003e \u003cli\u003eEasy integration into distribution boards and panels\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMCN332\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3P (Three Pole)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA (Icn per IEC 60898-1); 10kA (Icu per IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eTripping Curve\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eMCB (Miniature Circuit Breaker)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eIEC safety standards\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eResidential homes, villas, and apartments\u003c\/li\u003e \u003cli\u003eCommercial buildings: offices, schools, hospitals, and retail outlets\u003c\/li\u003e \u003cli\u003eLight industrial power distribution panels\u003c\/li\u003e \u003cli\u003eCircuit protection requiring Type C tripping characteristics\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (like the MCN332) protects the circuit and cabling against overload and short-circuit currents. An RCCB\/RCD instead protects against earth leakage and electric shock. The two devices do different jobs and are typically installed together, not as substitutes for one another.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does 3-pole (3P) mean and when do I need it?\u003c\/strong\u003e\u003cbr\u003eA 3-pole breaker switches all three live phases of a three-phase supply simultaneously. It's used for three-phase loads and distribution circuits, as opposed to a 1-pole or 2-pole device used on single-phase final circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the MCN332 compatible with existing Hager distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes. It's a standard DIN-rail (EN 60715) mounted MCB and integrates directly into Hager's modular consumer units and distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C tripping curve mean, and when would I choose it over Type B?\u003c\/strong\u003e\u003cbr\u003eType C trips at roughly 5-10 times rated current, giving it enough margin to handle the inrush of motors and transformers without nuisance tripping. Type B trips at a lower 3-5x threshold and suits purely resistive loads. Type C is the common choice for mixed commercial and light industrial panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797538807907,"sku":"MCN332","price":76.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MCN332.webp?v=1786954813"},{"product_id":"hager-40a-2p-mcb-type-c-mcn240","title":"Hager MCN240 MCB 40A 2-Pole 6kA Type C — Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager MCN240 MCB 40A 2-Pole 6kA Type C — Made in France\u003c\/h2\u003e\n\u003cp\u003eThe Hager MCN240 is a 40A, 2-pole miniature circuit breaker, Made in France, designed to protect electrical installations against overloads and short circuits. With a 6kA breaking capacity and a Type C tripping curve, it suits residential, commercial, and light industrial circuits with moderate inrush currents. The 2-pole (Line + Neutral) configuration provides full double-pole isolation and mounts easily into Hager DIN-rail distribution boards used across UAE installations.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: MCN240, 40A rated current, 2P (double pole) configuration\u003c\/li\u003e\n\u003cli\u003e6kA rated breaking capacity (Icn) to IEC 60898-1\u003c\/li\u003e\n\u003cli\u003eType C tripping curve for circuits with moderate inrush current\u003c\/li\u003e\n\u003cli\u003e2 modules (35mm total width) — compact double-pole DIN-rail footprint\u003c\/li\u003e\n\u003cli\u003eIP20 enclosure rating with a wide -25°C to +70°C operating range\u003c\/li\u003e\n\u003cli\u003eScrew-terminal connections, rigid conductors up to 35mm² \/ flexible up to 25mm²\u003c\/li\u003e\n\u003cli\u003eFully compliant with IEC 60898-1, IEC 60947-2, and IEC 60664\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMCN240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P (Double Pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Icn)\u003c\/td\u003e\n\u003ctd\u003e6 kA per IEC 60898-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Curve\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 - 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V (4,000 V impulse withstand)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Width\u003c\/td\u003e\n\u003ctd\u003e2 modules (35 mm total width)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Capacity\u003c\/td\u003e\n\u003ctd\u003eRigid 1-35 mm² \/ Flexible 1-25 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 60898-1, IEC 60947-2, IEC 60664\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in France\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential villas and apartments\u003c\/li\u003e\n\u003cli\u003eCommercial buildings: offices, schools, hospitals, retail outlets\u003c\/li\u003e\n\u003cli\u003eLight industrial power distribution systems\u003c\/li\u003e\n\u003cli\u003eCircuits requiring double-pole isolation with Type C tripping characteristics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (like the MCN240) protects the circuit and cabling against overload and short-circuit currents. An RCCB\/RCD instead protects against earth leakage and electric shock. The two devices do different jobs and are typically installed together, not as substitutes for one another.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does 2-pole (2P) mean and when do I need it?\u003c\/strong\u003e\u003cbr\u003eA 2-pole breaker switches both the line and neutral conductors together, giving full double-pole isolation. It's typically specified where a circuit or sub-board needs complete disconnection from supply, rather than the single-pole (line-only) switching used on standard final circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the MCN240 compatible with existing Hager distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes. It's a standard DIN-rail (EN 60715) mounted MCB and integrates directly into Hager's modular consumer units and distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between Type B and Type C tripping curves?\u003c\/strong\u003e\u003cbr\u003eType C trips at roughly 5-10 times rated current, giving it enough margin to handle the inrush of motors, transformers, and lighting ballasts without nuisance tripping. Type B trips at a lower 3-5x threshold and suits purely resistive loads. Type C is the common choice for mixed commercial and light industrial circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797538906211,"sku":"MCN240","price":82.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MCN240.webp?v=1786954812"},{"product_id":"hager-40a-2p-isolator-sbn240","title":"Hager SBN240 Isolator 40A 2-Pole — Main Switch Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager Isolator 40A 2P – SBN240\u003c\/h2\u003e\n\u003cp\u003eThe Hager SBN240 is a 40A, 2-pole isolator (switch-disconnector) used as a main switch or local isolation point ahead of MCBs and RCCBs in a distribution board. It provides safe, manual off-load disconnection for maintenance, testing, or emergency shutdown, and is Made in France to Hager's standard build quality for UAE residential, commercial, and light industrial installations.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e40 A rated current, 2-pole (2P) switch-disconnector for single-phase supplies\u003c\/li\u003e\n\u003cli\u003eRated operational voltage 400 V AC, rated insulation voltage 440 V\u003c\/li\u003e\n\u003cli\u003eShort-circuit making capacity 0.84 kA and 1-second short-time withstand of 0.60 kA\u003c\/li\u003e\n\u003cli\u003eCompact 2-module DIN rail enclosure (83 x 35 mm), fits standard consumer units and panels\u003c\/li\u003e\n\u003cli\u003eBiconnect aligned terminals top and bottom, accepting 2.5–16 mm² flexible or 2.5–25 mm² rigid conductors\u003c\/li\u003e\n\u003cli\u003eIP20 protection, 50–60 Hz operation, -20 °C to 70 °C operating range\u003c\/li\u003e\n\u003cli\u003eRated for 60,000 mechanical operations and 5,000 electrical (AC21\/AC22) cycles\u003c\/li\u003e\n\u003cli\u003eComplies with IEC 60947-3 and IEC 60669-2-4; RoHS compliant and REACH-SVHC free\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSBN240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eIsolator \/ Switch-Disconnector (Main Switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaking Capacity\u003c\/td\u003e\n\u003ctd\u003e0.84 kA at 415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Time Withstand\u003c\/td\u003e\n\u003ctd\u003e0.60 kA (1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eBiconnect aligned terminals, top and bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Capacity\u003c\/td\u003e\n\u003ctd\u003e2.5–16 mm² flexible \/ 2.5–25 mm² rigid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Width\u003c\/td\u003e\n\u003ctd\u003e2 modules (83 x 35 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDurability\u003c\/td\u003e\n\u003ctd\u003e60,000 mechanical operations \/ 5,000 electrical cycles (AC21\/AC22)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-3, IEC 60669-2-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in France\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain switch \/ isolation point ahead of an MCB or RCCB distribution board in villas and apartments\u003c\/li\u003e\n\u003cli\u003eCommercial buildings: offices, retail units, schools\u003c\/li\u003e\n\u003cli\u003eLight industrial panels requiring a lockable manual disconnect for maintenance\u003c\/li\u003e\n\u003cli\u003eAny 40A single-phase (2-pole) supply needing off-load isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the SBN240 an MCB or an isolator?\u003c\/strong\u003e\u003cbr\u003eIt's an isolator (switch-disconnector), not an MCB. It has no overload or short-circuit protection — it only provides a manual on\/off disconnect. Despite being listed under \"MCBs\" in some catalogue views, the SBN240 is a main switch\/isolator and should be paired with separate MCBs or RCCBs for circuit protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does 2-pole (2P) mean for this isolator?\u003c\/strong\u003e\u003cbr\u003e2-pole means it switches both the live and neutral conductors together on a single-phase supply, giving full off-load isolation of the circuit rather than switching just the live conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere should this isolator be installed?\u003c\/strong\u003e\u003cbr\u003eTypically as the main incoming switch or a local isolation point ahead of the MCBs\/RCCBs in a distribution board, so the whole board (or a section of it) can be isolated for maintenance without needing to trip individual breakers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is trade-only distribution board equipment and must be installed and connected by a licensed electrician in accordance with local wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan the SBN240 be used to switch a live circuit under load?\u003c\/strong\u003e\u003cbr\u003eIt is rated for on-load switching within its AC21\/AC22 utilisation category, but it is not a protective device — it should be operated as an isolator for maintenance and emergency disconnection, not as a substitute for a circuit breaker.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797539037283,"sku":"SBN240","price":45.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/SBN240.webp?v=1787498920"},{"product_id":"hager-100a-3p-mcb-10ka-hlf390s","title":"Hager HLF390S MCB 100A 3-Pole 10kA — Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager MCB 100A 3P 10kA – HLF390S (Miniature Circuit Breaker)\u003c\/h2\u003e\n\u003cp\u003eThe Hager HLF390S is a 3-pole miniature circuit breaker (MCB) that protects distribution circuits against overload and short-circuit faults. With a 100 A rated current, C-curve tripping, and 10 kA breaking capacity, it's built for higher-demand three-phase circuits in residential, commercial, and industrial panels, and is Made in France to Hager's standard build quality for UAE installations.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3-pole (3P) configuration for three-phase circuit protection\u003c\/li\u003e\n\u003cli\u003e100 A rated current for high-demand distribution circuits\u003c\/li\u003e\n\u003cli\u003eC-curve tripping characteristic, suited to circuits with moderate inrush current\u003c\/li\u003e\n\u003cli\u003e10 kA breaking capacity (Icn to IEC 60898-1, Icu to IEC 60947-2) for reliable fault interruption\u003c\/li\u003e\n\u003cli\u003eCompact 4.5-module width for space-efficient panel integration\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage 500 V, 6000 V impulse withstand, Pollution Degree 3\u003c\/li\u003e\n\u003cli\u003eIP20 protection, screw terminals (top and bottom), -25 °C to 70 °C operating range\u003c\/li\u003e\n\u003cli\u003eComplies with IEC 60898-1 and IEC 60947-2; RoHS compliant and REACH-SVHC free\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHLF390S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eMCB (Miniature Circuit Breaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Curve\u003c\/td\u003e\n\u003ctd\u003eC-curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e10 kA (Icn per IEC 60898-1, Icu per IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e6000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e3 (IEC 60664 \/ 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals, top and bottom; 360° mounting capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Width\u003c\/td\u003e\n\u003ctd\u003e4.5 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 °C to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 60898-1, IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in France\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential complexes and villas with three-phase supply\u003c\/li\u003e\n\u003cli\u003eCommercial offices, malls, schools, and healthcare facilities\u003c\/li\u003e\n\u003cli\u003eIndustrial power distribution systems\u003c\/li\u003e\n\u003cli\u003eProjects requiring high-capacity 3-pole, 100A circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10kA rating mean?\u003c\/strong\u003e\u003cbr\u003e10kA is the breaking capacity — the maximum short-circuit fault current the MCB can safely interrupt without damage. It's matched to the fault levels expected on typical UAE three-phase distribution circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is a C-curve MCB used for?\u003c\/strong\u003e\u003cbr\u003eC-curve breakers tolerate higher inrush\/starting currents (roughly 5–10x rated current) before tripping instantly, making them suitable for circuits with motors, transformers, or other inductive loads — as opposed to B-curve breakers used for simple resistive\/lighting circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need for this circuit?\u003c\/strong\u003e\u003cbr\u003eA 3-pole MCB switches and protects all three phases of a three-phase circuit simultaneously. Use a 3P breaker (like the HLF390S) for three-phase loads; single-phase circuits only need a 1P or 2P device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this MCB compatible with other Hager distribution boards?\u003c\/strong\u003e\u003cbr\u003eYes. The HLF390S is a standard DIN rail MCB and mounts directly onto Hager consumer units and panel boards alongside other Hager modular devices (RCCBs, RCBOs, isolators) on the same busbar system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCBs are installed inside a distribution board and connected to live supply conductors — this must be done by a licensed electrician in accordance with local wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797539102819,"sku":"HLF390S","price":438.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/HLF390S.webp?v=1786954811"},{"product_id":"hager-63a-4p-rccb-300ma-cfc464j","title":"Hager CFC464J RCCB 63A 4-Pole 300mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CFC464J RCCB 63A 4-Pole 300mA Type AC — ELCB\u003c\/h2\u003e\n\u003cp\u003eThe Hager CFC464J is a 63A, 4-pole residual current circuit breaker (RCCB\/ELCB) with 300mA Type AC sensitivity, made in France for earth-leakage protection on medium-to-large residential, commercial, and light industrial installations in the UAE. Its 300mA rating is calibrated for fire and equipment protection on distribution circuits rather than individual socket outlets.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated current: 63A, 4-pole (3P+N) configuration\u003c\/li\u003e\n\u003cli\u003e300mA Type AC sensitivity — fire\/equipment protection level\u003c\/li\u003e\n\u003cli\u003eRated voltage: 240–415V AC, 50Hz\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Idm): 1.50kA; conditional short-circuit current (Inc): 6kA per EN 61008-1\u003c\/li\u003e\n\u003cli\u003eIP20 protection rating, compact 4-module DIN rail width\u003c\/li\u003e\n\u003cli\u003eScrew terminals (top) and biconnect terminals (bottom); 1–25mm² rigid \/ 1–16mm² flexible conductor capacity\u003c\/li\u003e\n\u003cli\u003eRated for 4,000 mechanical and 2,000 electrical operating cycles\u003c\/li\u003e\n\u003cli\u003eMade in France by Hager, compliant with IEC\/EN safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCFC464J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e63 A (derates to 45 A at 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P (3P+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity (Idn)\u003c\/td\u003e\n\u003ctd\u003e300 mA, Type AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage (Ue)\u003c\/td\u003e\n\u003ctd\u003e240–415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Idm)\u003c\/td\u003e\n\u003ctd\u003e1.50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConditional Short-Circuit Current (Inc)\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e4,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting \/ Dimensions\u003c\/td\u003e\n\u003ctd\u003eDIN rail, 4 modules — 83 × 70 × 70 mm (H×W×D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd\u003e1–25 mm² rigid \/ 1–16 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +70°C (derated above 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndurance\u003c\/td\u003e\n\u003ctd\u003e4,000 mechanical \/ 2,000 electrical cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential villas and housing projects\u003c\/li\u003e\n\u003cli\u003eCommercial offices, schools, hospitals, and retail spaces\u003c\/li\u003e\n\u003cli\u003eIndustrial distribution panels\u003c\/li\u003e\n\u003cli\u003eInstallations requiring 63A, 4-pole, 300mA leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects a circuit from overload and short-circuit current. An RCCB\/RCD like the CFC464J monitors for earth leakage current and trips to prevent fire and equipment damage — it does not provide overload protection. The two are typically installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 300mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e300mA is a fire\/equipment-protection threshold rather than a personnel-protection one: the CFC464J trips on larger leakage currents, making it suited to main incomers and distribution circuits where nuisance tripping from cumulative leakage must be avoided, while 30mA devices are used on individual final circuits for shock protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThe CFC464J is a 4-pole (3P+N) device for three-phase supplies with neutral, protecting all three phases and the neutral conductor. Use a 2-pole RCCB for single-phase circuits instead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution-board component that must be installed and commissioned by a licensed electrician in accordance with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797539856483,"sku":"CFC464J","price":166.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CFC464J.webp?v=1786954809"},{"product_id":"hager-63a-4p-mcb-6ka-mcn463","title":"Hager MCN463 MCB 63A 4-Pole 6kA Type C — Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager MCN463 MCB 63A 4-Pole 6kA Type C\u003c\/h2\u003e\n\u003cp\u003eThe Hager MCN463 is a 63A, 4-pole miniature circuit breaker (MCB) built to protect distribution circuits from overloads and short circuits. With a Type C tripping curve and 6kA breaking capacity, it suits circuits with moderate inrush current — motors, transformers, and mixed commercial loads — across residential, commercial, and industrial panels. Made in France, it carries Hager's full European engineering and manufacturing standard for long service life in demanding installations.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e63A rated current, Type C tripping curve (5–10 × In) for loads with moderate inrush\u003c\/li\u003e\n\u003cli\u003e4-pole (4P) design — switches all phases plus neutral together\u003c\/li\u003e\n\u003cli\u003e6kA breaking capacity (Icn) for reliable fault clearance\u003c\/li\u003e\n\u003cli\u003e400V rated operational voltage, 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eCompact 4-module DIN rail mounting, IP20 enclosure\u003c\/li\u003e\n\u003cli\u003eScrew terminals rated 1–35mm² (rigid) \/ 1–25mm² (flexible) conductors\u003c\/li\u003e\n\u003cli\u003eComplies with IEC safety standards for miniature circuit breakers\u003c\/li\u003e\n\u003cli\u003eMade in France — genuine Hager build quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMCN463\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eMCB (Miniature Circuit Breaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P (Four Pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Curve\u003c\/td\u003e\n\u003ctd\u003eType C (5–10 × In)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Icn \/ Ics \/ Icu)\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Width\u003c\/td\u003e\n\u003ctd\u003e4 modules (DIN rail)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd\u003e1–35 mm² (rigid) \/ 1–25 mm² (flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC safety standards for MCBs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential villas and apartment complexes\u003c\/li\u003e\n\u003cli\u003eCommercial buildings: offices, schools, hospitals, retail spaces\u003c\/li\u003e\n\u003cli\u003eIndustrial distribution boards and panels\u003c\/li\u003e\n\u003cli\u003eProjects requiring robust 4-Pole 63A MCB protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (like the MCN463) protects circuits and wiring against overload and short-circuit current. An RCCB\/RCD protects people against earth leakage\/electric shock by monitoring current imbalance. The two do different jobs and are typically installed together in a distribution board, not as substitutes for each other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the MCN463 compatible with my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eYes. The MCN463 is a standard 4-module Hager DIN-rail MCB and clips directly onto Hager DB rails alongside other Hager MCBs, RCCBs, and accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the Type C curve mean, and is it right for my circuit?\u003c\/strong\u003e\u003cbr\u003eType C breakers trip on short circuit at 5–10 times their rated current, giving them tolerance for the inrush of motors, transformers, and other inductive loads. They're a common general-purpose choice for commercial and light industrial circuits; Type B is typically reserved for purely resistive residential circuits with low inrush.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need for a 4-pole circuit?\u003c\/strong\u003e\u003cbr\u003eA 4-pole (4P) breaker switches all three phases plus the neutral. Use 4P when you need to fully isolate a three-phase circuit, including the neutral conductor — common on larger commercial and industrial distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCBs are hardwired into a live distribution board and must be installed or replaced by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797540020323,"sku":"B001Z3VX02","price":178.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MCN463.webp?v=1786954808"},{"product_id":"hager-onekonekt-63a-4p-isolator","title":"Hager SBN464N Onekonekt Isolator 63A 4-Pole — Main Switch Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager Onekonekt Isolator 63A 4P – SBN464N\u003c\/h2\u003e\n\u003cp\u003eThe Hager SBN464N is a 63A, 4-pole isolator (switch-disconnector) from Hager's Onekonekt range, used as a main switch or local isolation point ahead of MCBs, RCCBs, and RCBOs in a distribution board. Onekonekt is Hager's captive\/tunnel terminal busbar connection system — devices clip securely onto a shared comb busbar without loose screw-terminal bus wiring, speeding up panel assembly and keeping bus connections tidy and secure. The SBN464N provides safe, manual off-load disconnection for maintenance, testing, or emergency shutdown across residential, commercial, and industrial installations, and is Made in France to Hager's standard build quality for UAE projects.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e63 A rated current, 4-pole (4P) switch-disconnector for three-phase supplies (with or without switched neutral, depending on wiring configuration)\u003c\/li\u003e\n\u003cli\u003eOnekonekt captive\/tunnel terminal design for tool-free, secure busbar connection alongside other Onekonekt devices\u003c\/li\u003e\n\u003cli\u003eProvides complete off-load circuit isolation for maintenance and emergency disconnection\u003c\/li\u003e\n\u003cli\u003eRobust, compact 4-module DIN rail enclosure for easy panel integration\u003c\/li\u003e\n\u003cli\u003eComplies with IEC 60947-3, the standard governing low-voltage switch-disconnectors\u003c\/li\u003e\n\u003cli\u003eIP20 protection, suitable for enclosed distribution board\/panel mounting\u003c\/li\u003e\n\u003cli\u003eNext-day delivery available in the UAE from Deluxe Electricals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager – Onekonekt range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSBN464N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eIsolator \/ Switch-Disconnector (Main Switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P (Four Pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal \/ Connection Type\u003c\/td\u003e\n\u003ctd\u003eOnekonekt captive\/tunnel busbar terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in France\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential main distribution panels\u003c\/li\u003e\n\u003cli\u003eCommercial facilities: offices, shops, schools, hospitals\u003c\/li\u003e\n\u003cli\u003eIndustrial power control panels\u003c\/li\u003e\n\u003cli\u003eMaintenance isolation for 63A three-phase circuits wired on a Onekonekt busbar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Onekonekt\" mean on this isolator?\u003c\/strong\u003e\u003cbr\u003eOnekonekt is Hager's captive\/tunnel terminal busbar connection system. Instead of individual screw-terminal bus wiring between devices, Onekonekt devices clip directly onto a shared comb busbar, giving a faster, tidier, and more secure bus connection across the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the SBN464N an MCB or an isolator?\u003c\/strong\u003e\u003cbr\u003eIt's an isolator (switch-disconnector), not an MCB. It has no overload or short-circuit protection — it provides a manual on\/off disconnect only, and should be paired with separate MCBs, RCCBs, or RCBOs for circuit protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does 4-pole (4P) mean for this isolator?\u003c\/strong\u003e\u003cbr\u003e4-pole means it switches all four conductors of a three-phase-plus-neutral supply together, giving full off-load isolation of the circuit rather than switching only the phase conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use this with non-Onekonekt Hager devices in the same board?\u003c\/strong\u003e\u003cbr\u003eThe Onekonekt captive terminal connects to a Onekonekt busbar system; for boards using standard bus wiring, a non-Onekonekt Hager isolator (e.g. the SBN463 range) with screw terminals may be a better match. Check your existing busbar\/comb type before mixing ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is trade-only distribution board equipment and must be installed and connected by a licensed electrician in accordance with local wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797540479075,"sku":"SBN464N","price":129.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/SBN464N.webp?v=1786954808"},{"product_id":"hager-rccb-40a-2p-300ma","title":"Hager CFC241J RCCB 40A 2-Pole 300mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003cp\u003eHager 40A 2P 300mA RCCB (CFC241J) delivers reliable earth-leakage protection for UAE residential and commercial electrical installations. This compact device detects ground faults and isolates circuits to prevent electric shocks and fire risks, ensuring safety for homes, offices, and construction sites.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: CFC241J\u003c\/li\u003e\n\u003cli\u003eRated Current: 40 A\u003c\/li\u003e\n\u003cli\u003ePoles: 2P\u003c\/li\u003e\n\u003cli\u003eSensitivity: 300 mA\u003c\/li\u003e\n\u003cli\u003eType: RCCB (ELCB) with earth leakage protection\u003c\/li\u003e\n\u003cli\u003eCompact design for easy installation\u003c\/li\u003e\n\u003cli\u003eIEC standards compliant\u003c\/li\u003e\n\u003cli\u003eSuitable for panel boards and consumer units in UAE projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCFC241J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eRCCB (ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth Leakage Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel \/ Consumer Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eResidential distribution boards and consumer units\u003c\/li\u003e\n\u003cli\u003eCommercial electrical panels and service boards\u003c\/li\u003e\n\u003cli\u003eAreas requiring reliable ground fault protection\u003c\/li\u003e\n\u003cli\u003eProjects prioritizing quick, safe isolation of leakage currents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an RCCB and an MCB?\u003c\/strong\u003e\u003cbr\u003eAn RCCB (ELCB) detects earth leakage current and disconnects the circuit to protect against electric shock — it does not protect against overload or short-circuit current. It's normally installed alongside MCBs, which handle overload and short-circuit protection; the two work together, not as substitutes for each other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 300mA rating mean, and do I need this sensitivity?\u003c\/strong\u003e\u003cbr\u003e300mA sensitivity is typically used for fire protection on distribution or fixed-appliance circuits, rather than direct personal shock protection — check your circuit's requirement before ordering. If you're unsure which sensitivity your board needs, an electrician can confirm from the circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole unit, suited to a single-phase circuit (with neutral switched). Match the pole count to your incoming supply and the circuit(s) you're protecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — an RCCB is installed inside a distribution board and connected to live busbars. This must be done by a licensed electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797540577379,"sku":"CFC241J","price":106.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CFC241J.webp?v=1786954789"},{"product_id":"hager-rccb-63a-4p-30ma","title":"Hager CDC464J RCCB 63A 4-Pole 30mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager RCCB (ELCB) 63A 4P 30mA – CDC464J\u003c\/h2\u003e\n\u003cp\u003eThe CDC464J is a four-pole RCCB (ELCB) with 63A rating and 30mA sensitivity, delivering fast earth-leakage protection for people and equipment in UAE installations. Reliable, compact, and panel-friendly for residential, commercial, and light industrial applications.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eBrand: Hager\u003c\/li\u003e \u003cli\u003eModel: CDC464J\u003c\/li\u003e \u003cli\u003eRated Current: 63A\u003c\/li\u003e \u003cli\u003ePoles: 4P\u003c\/li\u003e \u003cli\u003eSensitivity: 30mA\u003c\/li\u003e \u003cli\u003eDevice Type: RCCB \/ ELCB\u003c\/li\u003e \u003cli\u003eFast leakage tripping\u003c\/li\u003e \u003cli\u003eCompact, panel-mount design\u003c\/li\u003e \u003cli\u003eIEC safety standards compliant\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCDC464J\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC safety standards compliant\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eResidential villas and apartment complexes\u003c\/li\u003e \u003cli\u003eOffices, schools, hospitals, and retail spaces\u003c\/li\u003e \u003cli\u003eLight industrial distribution panels\u003c\/li\u003e \u003cli\u003eElectrical systems requiring 30mA high-sensitivity protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an RCCB and an MCB?\u003c\/strong\u003e\u003cbr\u003eAn RCCB (ELCB) detects earth leakage current and disconnects the circuit to protect against electric shock — it does not protect against overload or short-circuit current. It's normally installed alongside MCBs, which handle overload and short-circuit protection; the two work together, not as substitutes for each other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30mA rating mean, and do I need this sensitivity?\u003c\/strong\u003e\u003cbr\u003e30mA is the sensitivity required for personal shock protection on socket outlet and bathroom circuits per most wiring regulations. If you're unsure which sensitivity your board needs, an electrician can confirm from the circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 4-pole unit, suited to a three-phase circuit. Match the pole count to your incoming supply and the circuit(s) you're protecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — an RCCB is installed inside a distribution board and connected to live busbars. This must be done by a licensed electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797540741219,"sku":"Cdc464J","price":251.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CDC464J.webp?v=1786954806"},{"product_id":"hager-rccb-40a-2p-100ma","title":"Hager CEC241J RCCB 40A 2-Pole 100mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager RCCB (ELCB) 40A 2P 100mA – CEC241J\u003c\/h2\u003e\n\u003cp\u003eReliable earth-leakage protection for residential, commercial, and light industrial panels. The CEC241J delivers fast leakage tripping, compact installation, and IEC-compliant performance for UAE projects.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eBrand: Hager\u003c\/li\u003e \u003cli\u003eModel: CEC241J\u003c\/li\u003e \u003cli\u003eRated Current: 40A\u003c\/li\u003e \u003cli\u003ePoles: 2P (Double Pole)\u003c\/li\u003e \u003cli\u003eSensitivity: 100mA\u003c\/li\u003e \u003cli\u003eDevice Type: RCCB \/ ELCB\u003c\/li\u003e \u003cli\u003eFast tripping on leakage faults\u003c\/li\u003e \u003cli\u003eIEC standards compliant\u003c\/li\u003e \u003cli\u003eCompact design for easy panel installation\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eSpecification\u003c\/th\u003e \u003cth\u003eDetails\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eHager\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eModel\u003c\/td\u003e \u003ctd\u003eCEC241J\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRated Current\u003c\/td\u003e \u003ctd\u003e40A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePoles\u003c\/td\u003e \u003ctd\u003e2P (Double Pole)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSensitivity\u003c\/td\u003e \u003ctd\u003e100mA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDevice Type\u003c\/td\u003e \u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStandards\u003c\/td\u003e \u003ctd\u003eIEC compliant\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip characteristics\u003c\/td\u003e \u003ctd\u003eFast tripping on leakage faults\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eResidential apartments, villas, and homes\u003c\/li\u003e \u003cli\u003eOffices, schools, and retail spaces\u003c\/li\u003e \u003cli\u003eLight industrial power systems\u003c\/li\u003e \u003cli\u003ePanels requiring 100mA medium-sensitivity leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an RCCB and an MCB?\u003c\/strong\u003e\u003cbr\u003eAn RCCB (ELCB) detects earth leakage current and disconnects the circuit to protect against electric shock — it does not protect against overload or short-circuit current. It's normally installed alongside MCBs, which handle overload and short-circuit protection; the two work together, not as substitutes for each other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA rating mean, and do I need this sensitivity?\u003c\/strong\u003e\u003cbr\u003e100mA sensitivity is typically used for fire protection on distribution or fixed-appliance circuits, rather than direct personal shock protection — check your circuit's requirement before ordering. If you're unsure which sensitivity your board needs, an electrician can confirm from the circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole unit, suited to a single-phase circuit (with neutral switched). Match the pole count to your incoming supply and the circuit(s) you're protecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — an RCCB is installed inside a distribution board and connected to live busbars. This must be done by a licensed electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797540937827,"sku":"CEC241J","price":107.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CEC241J.webp?v=1786954804"},{"product_id":"hager-rccb-100a-4p-100ma","title":"Hager CE485Z RCCB 100A 4-Pole 100mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CE485Z RCCB 100A 4-Pole 100mA Type AC\u003c\/h2\u003e\n\u003cp\u003eThe Hager CE485Z is a 100A, 4-pole residual current circuit breaker (RCCB\/ELCB) with 100mA sensitivity, built to protect large residential, commercial, and industrial installations from earth leakage faults. Type AC sensing detects standard sinusoidal residual currents, disconnecting the circuit to reduce the risk of fire and equipment damage. Made in France, the CE485Z carries Hager's full European build and design standard for demanding distribution boards.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e100A rated current, 4-pole (4P) — switches all phases plus neutral\u003c\/li\u003e\n\u003cli\u003e100mA tripping sensitivity — sized for fire\/equipment protection on larger circuits, not personnel protection\u003c\/li\u003e\n\u003cli\u003eType AC residual current sensing for standard sinusoidal leakage currents\u003c\/li\u003e\n\u003cli\u003e1.5kA breaking capacity; 6kA rated conditional short-circuit current (per EN 61008-1)\u003c\/li\u003e\n\u003cli\u003eCompact 4-module DIN rail mounting, IP20 enclosure\u003c\/li\u003e\n\u003cli\u003eRated for 2000 electrical \/ 4000 mechanical operations\u003c\/li\u003e\n\u003cli\u003eScrew terminal connections\u003c\/li\u003e\n\u003cli\u003eComplies with IEC 61008-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCE485Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB (Residual Current Circuit Breaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Residual Operating Current (IΔn)\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P (Four Pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e1.5 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current\u003c\/td\u003e\n\u003ctd\u003e6 kA (per EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Width\u003c\/td\u003e\n\u003ctd\u003e4 modules (DIN rail)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Endurance\u003c\/td\u003e\n\u003ctd\u003e2000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Endurance\u003c\/td\u003e\n\u003ctd\u003e4000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial distribution boards and switchgear\u003c\/li\u003e\n\u003cli\u003eCommercial facilities: offices, malls, schools, hospitals\u003c\/li\u003e\n\u003cli\u003eLarge residential complexes and villas\u003c\/li\u003e\n\u003cli\u003eProjects requiring 100A 4-Pole protection at 100mA sensitivity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects circuits and wiring against overload and short-circuit current. An RCCB like the CE485Z protects against earth leakage by monitoring current imbalance and disconnecting the circuit — the two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e100mA RCCBs are sized for fire and equipment protection on larger circuits and sub-mains, not personal shock protection — that requires a 30mA device. A 100mA unit is a common choice as a main incomer or sub-distribution protection device upstream of 30mA final-circuit RCDs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need — why 4-pole?\u003c\/strong\u003e\u003cbr\u003eA 4-pole (4P) RCCB switches all three phases plus the neutral together. Use 4P for three-phase supplies or distribution boards where the neutral must also be isolated; 2-pole devices are used for single-phase circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be used alongside MCBs in the same board?\u003c\/strong\u003e\u003cbr\u003eYes. The CE485Z is typically installed upstream of the MCBs it protects, on the same Hager DIN rail, so a leakage fault trips the RCCB while overloads\/short circuits are still cleared by the individual MCBs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCCBs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797541134435,"sku":"CE485Z","price":405.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CE485Z.webp?v=1786954803"},{"product_id":"hager-rccb-100a-2p-100ma","title":"Hager CE285Z RCCB 100A 2-Pole 100mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CE285Z RCCB 100A 2-Pole 100mA Type AC\u003c\/h2\u003e\n\u003cp\u003eThe Hager CE285Z is a 100A, 2-pole residual current circuit breaker (RCCB\/ELCB) with 100mA sensitivity, designed to protect single-phase residential, commercial, and light industrial circuits from earth leakage faults. Type AC sensing detects standard sinusoidal residual currents, disconnecting the circuit to reduce shock, fire, and equipment-damage risk. Made in France, it carries Hager's full European design and manufacturing standard.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e100A rated current, 2-pole (2P) — switches line and neutral\u003c\/li\u003e\n\u003cli\u003e100mA tripping sensitivity — sized for fire\/equipment protection, not personnel protection\u003c\/li\u003e\n\u003cli\u003eType AC residual current sensing for standard sinusoidal leakage currents\u003c\/li\u003e\n\u003cli\u003e1.5kA breaking capacity; 6kA rated conditional short-circuit current (per EN 61008-1)\u003c\/li\u003e\n\u003cli\u003eCompact 2-module DIN rail mounting (35mm wide), IP20 enclosure\u003c\/li\u003e\n\u003cli\u003eRated for 2000 electrical \/ 4000 mechanical operations\u003c\/li\u003e\n\u003cli\u003eScrew terminal connections\u003c\/li\u003e\n\u003cli\u003eComplies with IEC 61008-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCE285Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB (Residual Current Circuit Breaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Residual Operating Current (IΔn)\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P (Double Pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e1.5 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current\u003c\/td\u003e\n\u003ctd\u003e6 kA (per EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Width\u003c\/td\u003e\n\u003ctd\u003e2 modules, 35 mm (DIN rail)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Endurance\u003c\/td\u003e\n\u003ctd\u003e2000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Endurance\u003c\/td\u003e\n\u003ctd\u003e4000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential villas and apartment complexes\u003c\/li\u003e\n\u003cli\u003eCommercial spaces: offices, schools, retail stores, hospitals\u003c\/li\u003e\n\u003cli\u003eIndustrial distribution boards and small control systems\u003c\/li\u003e\n\u003cli\u003eProjects requiring 100A 2-Pole medium-sensitivity protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects circuits and wiring against overload and short-circuit current. An RCCB like the CE285Z protects against earth leakage by monitoring current imbalance and disconnecting the circuit — the two are complementary and normally installed together.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e100mA RCCBs are sized for fire and equipment protection, not personal shock protection — that requires a 30mA device. A 100mA unit is a common choice as a main incomer or sub-distribution device upstream of 30mA final-circuit RCDs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need — what does 2-pole mean for this circuit?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (2P) RCCB switches the line and neutral conductors of a single-phase circuit. Use 2P for single-phase supplies and circuits; 4-pole devices are used where all three phases plus neutral need isolating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCCBs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be paired with MCBs on the same board?\u003c\/strong\u003e\u003cbr\u003eYes. The CE285Z is typically installed upstream of the MCBs it protects on the same Hager DIN rail, so an earth leakage fault trips the RCCB while overloads\/short circuits are cleared by the individual MCBs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797541265507,"sku":"CE285Z","price":200.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CE285Z.webp?v=1786954801"},{"product_id":"hager-rccb-40a-4p-300ma","title":"Hager CFC441J RCCB 40A 4-Pole 300mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CFC441J RCCB 40A 4-Pole 300mA Type AC (ELCB)\u003c\/h2\u003e\n\u003cp\u003eThe Hager CFC441J is a 4-pole residual current circuit breaker (RCCB\/ELCB) rated 40 A with 300 mA sensitivity, built for earth-leakage protection on larger residential, commercial, and light industrial distribution boards. Manufactured in France, it disconnects the circuit quickly on detecting a leakage fault, protecting connected equipment and reducing fire risk from earth faults. Type AC sensing suits standard AC installations.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4-pole (3P+N) RCCB for 3-phase, 4-wire distribution circuits\u003c\/li\u003e\n\u003cli\u003eRated current: 40 A\u003c\/li\u003e\n\u003cli\u003eSensitivity (rated residual operating current): 300 mA, Type AC\u003c\/li\u003e\n\u003cli\u003eRated conditional short-circuit current (Inc): 6 kA per EN 61008-1\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Idm): 1.5 kA\u003c\/li\u003e\n\u003cli\u003eCompact 4-module DIN rail enclosure (70 mm wide)\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage 500 V, impulse withstand 4,000 V\u003c\/li\u003e\n\u003cli\u003eComplies with IEC\/EN 61008-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCFC441J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P (3P+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Residual Operating Current (Idn)\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e240\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Idm)\u003c\/td\u003e\n\u003ctd\u003e1.5 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current (Inc)\u003c\/td\u003e\n\u003ctd\u003e6 kA (per EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e4,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail, 4 modules (70 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e83 x 70 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd\u003e1–25 mm² solid \/ 1–16 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eMade in France\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential apartment blocks and villas with 3-phase supply\u003c\/li\u003e\n\u003cli\u003eCommercial buildings — offices, schools, hospitals, retail\u003c\/li\u003e\n\u003cli\u003eIndustrial distribution boards and sub-panels\u003c\/li\u003e\n\u003cli\u003eCircuits requiring 300 mA fire\/equipment-protection level sensitivity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects against overload and short-circuit currents. An RCCB (residual current circuit breaker), also called an ELCB, monitors the balance of current between line and neutral conductors and disconnects the circuit when it detects earth leakage — protecting against electric shock and fire from insulation faults. The two devices protect against different fault types and are typically installed together on a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 300 mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e300 mA is a higher-threshold sensitivity generally used for fire and equipment protection on larger distribution circuits, rather than direct personnel protection (which typically uses 30 mA devices). It trips on the larger leakage currents typical of insulation faults or equipment failure, reducing fire risk on sub-mains and distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does 4-pole mean and do I need it for this circuit?\u003c\/strong\u003e\u003cbr\u003eA 4-pole (3P+N) RCCB switches all three phase conductors and the neutral together. It's used on 3-phase, 4-wire circuits — typically main incomers or distribution boards feeding 3-phase loads — so both phase and neutral are isolated together on a leakage trip.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component that must be installed and connected by a licensed electrician in accordance with local wiring regulations. Incorrect installation of an RCCB can leave circuits without leakage protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit a standard Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eYes. The CFC441J is part of Hager's modular DIN-rail range and installs alongside Hager MCBs, isolators, and other DB accessories in a standard Hager consumer unit or distribution board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797541691491,"sku":"CF441J","price":122.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CFC441J.webp?v=1786954801"},{"product_id":"hager-rccb-63a-4p-100ma","title":"Hager CEC464J RCCB 63A 4-Pole 100mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CEC464J RCCB 63A 4-Pole 100mA Type AC (ELCB)\u003c\/h2\u003e\n\u003cp\u003eThe Hager CEC464J is a 4-pole residual current circuit breaker (RCCB\/ELCB) rated 63 A with 100 mA sensitivity, designed for earth-leakage protection on higher-current residential, commercial, and industrial distribution boards. Manufactured in France, it monitors line and neutral current continuously and disconnects the circuit rapidly on detecting an earth fault, reducing the risk of electrical fire and equipment damage from insulation faults. Type AC sensing suits standard AC installations.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 63 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 4 (3P+N)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current:\u003c\/strong\u003e 100 mA, Type AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Conditional Short-Circuit Current (Inc):\u003c\/strong\u003e 6 kA per IEC 61008-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (Idm):\u003c\/strong\u003e 1,500 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC 61008-1, RoHS compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Hager, Made in France\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCEC464J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Residual Operating Current (Idn)\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e240\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Idm)\u003c\/td\u003e\n\u003ctd\u003e1,500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current (Inc)\u003c\/td\u003e\n\u003ctd\u003e6 kA (per EN\/IEC 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e4,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail, 4 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e83 x 70 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eMade in France\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential buildings and villas with higher-current 3-phase supply\u003c\/li\u003e\n\u003cli\u003eCommercial buildings — offices, schools, hospitals, retail\u003c\/li\u003e\n\u003cli\u003eIndustrial distribution boards and main incomers up to 63 A\u003c\/li\u003e\n\u003cli\u003eCircuits requiring 100 mA fire\/equipment-protection level sensitivity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects against overload and short-circuit currents. An RCCB (residual current circuit breaker), also called an ELCB, monitors the balance of current between line and neutral conductors and disconnects the circuit when it detects earth leakage — protecting against electric shock and fire from insulation faults. The two devices protect against different fault types and are typically installed together on a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100 mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e100 mA sits between 30 mA personnel-protection devices and 300 mA fire-protection devices. It is commonly used for equipment and fire protection on distribution circuits where a very low trip threshold isn't required, tripping on the larger leakage currents typical of insulation faults or equipment failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does 4-pole mean and do I need it for this circuit?\u003c\/strong\u003e\u003cbr\u003eA 4-pole RCCB switches all three phase conductors and the neutral together. It's used on 3-phase, 4-wire circuits — typically main incomers or distribution boards feeding 3-phase loads — so both phase and neutral are isolated together on a leakage trip.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component that must be installed and connected by a licensed electrician in accordance with local wiring regulations. Incorrect installation of an RCCB can leave circuits without leakage protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit a standard Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eYes. The CEC464J is part of Hager's modular DIN-rail range and installs alongside Hager MCBs, isolators, and other DB accessories in a standard Hager consumer unit or distribution board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797541888099,"sku":"CEC464J","price":192.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/hager-elcbs-default-title-hager-earth-leakage-circuit-breaker-63a-4pole-100ma-elcb-rccb-cec464j-31538396135523.jpg?v=1787498198"},{"product_id":"hager-onekonekt-25a-2p-100ma-rccb","title":"Hager CEC226J Onekonekt RCCB 25A 2-Pole 100mA Type AC — ELCB","description":"\u003cdiv\u003e\n\u003cp\u003eHager Onekonekt RCCB (ELCB) 25A 2P 100mA – CEC226J\u003c\/p\u003e \u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Hager CEC226J RCCB provides reliable earth-leakage protection with a 25A rating and 100mA sensitivity. It rapidly disconnects circuits on leakage, helping protect people and equipment in residential, commercial, and light industrial UAE installations.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eBrand: Hager – Onekonekt Series\u003c\/li\u003e \u003cli\u003eModel: CEC226J\u003c\/li\u003e \u003cli\u003eRated Current: 25A\u003c\/li\u003e \u003cli\u003ePoles: 2P (Double Pole)\u003c\/li\u003e \u003cli\u003eSensitivity: 100mA\u003c\/li\u003e \u003cli\u003eDevice Type: RCCB \/ ELCB\u003c\/li\u003e \u003cli\u003eRobust, compact design for easy panel installation\u003c\/li\u003e \u003cli\u003eFully compliant with IEC safety standards\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager – Onekonekt Series\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCEC226J\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P (Double Pole)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100mA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC safety standards compliant\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eResidential homes, villas, and apartments\u003c\/li\u003e \u003cli\u003eOffices, schools, and healthcare facilities\u003c\/li\u003e \u003cli\u003eCommercial buildings and retail outlets\u003c\/li\u003e \u003cli\u003eLight industrial power systems requiring reliable leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an RCCB and an MCB?\u003c\/strong\u003e\u003cbr\u003eAn RCCB (ELCB) detects earth leakage current and disconnects the circuit to protect against electric shock — it does not protect against overload or short-circuit current. It's normally installed alongside MCBs, which handle overload and short-circuit protection; the two work together, not as substitutes for each other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA rating mean, and do I need this sensitivity?\u003c\/strong\u003e\u003cbr\u003e100mA sensitivity is typically used for fire protection on distribution or fixed-appliance circuits, rather than direct personal shock protection — check your circuit's requirement before ordering. If you're unsure which sensitivity your board needs, an electrician can confirm from the circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole unit, suited to a single-phase circuit (with neutral switched). Match the pole count to your incoming supply and the circuit(s) you're protecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — an RCCB is installed inside a distribution board and connected to live busbars. This must be done by a licensed electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797542281315,"sku":"CEC226J","price":164.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CEC226J.webp?v=1786954799"},{"product_id":"hager-rccb-63a-2p-30ma","title":"Hager CDC264J RCCB 63A 2-Pole 30mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CDC264J RCCB 63A 2-Pole 30mA Type AC (ELCB)\u003c\/h2\u003e\n\u003cp\u003eThe Hager CDC264J RCCB (ELCB) delivers rapid disconnection at earth leakage currents, enhancing protection for people and equipment. Rated 63 A with a 30 mA sensitivity, it provides personnel-protection level earth-leakage protection for single-phase circuits. Manufactured in France and engineered to IEC standards, it offers reliable, fast fault isolation in UAE electrical installations, with a compact, durable design that fits neatly into distribution boards.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: Hager, Made in France\u003c\/li\u003e\n\u003cli\u003eModel: CDC264J\u003c\/li\u003e\n\u003cli\u003eRated Current: 63 A\u003c\/li\u003e\n\u003cli\u003ePoles: 2P (1P+N, Double Pole)\u003c\/li\u003e\n\u003cli\u003eSensitivity: 30 mA, Type AC — personnel protection level\u003c\/li\u003e\n\u003cli\u003eRated conditional short-circuit current (Inc): 6 kA per EN 61008-1\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Idm): 1.5 kA\u003c\/li\u003e\n\u003cli\u003eCompact, 2-module DIN rail enclosure (35 mm wide)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCDC264J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P (1P+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Residual Operating Current (Idn)\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e240 V AC (max. 415 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Idm)\u003c\/td\u003e\n\u003ctd\u003e1.5 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current (Inc)\u003c\/td\u003e\n\u003ctd\u003e6 kA (per EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e4,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail, 2 modules (35 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e83 x 35 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd\u003e1–25 mm² solid \/ 1–16 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eMade in France\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential homes and villas — single-phase final circuits\u003c\/li\u003e\n\u003cli\u003eCommercial buildings: offices, schools, healthcare facilities\u003c\/li\u003e\n\u003cli\u003eLight industrial distribution systems\u003c\/li\u003e\n\u003cli\u003eCircuits requiring 30 mA personnel-protection level sensitivity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects against overload and short-circuit currents. An RCCB (residual current circuit breaker), also called an ELCB, monitors the balance of current between line and neutral conductors and disconnects the circuit when it detects earth leakage — protecting against electric shock and fire from insulation faults. The two devices protect against different fault types and are typically installed together on a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30 mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e30 mA is the internationally recognised threshold for personnel protection — sensitive enough to disconnect the circuit before a leakage current through a person's body becomes dangerous. It's the standard sensitivity for socket outlets and other circuits directly accessible to people.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does 2-pole mean and do I need it for this circuit?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (1P+N) RCCB switches the line and neutral conductors together. It's used on single-phase circuits, so both conductors are isolated together the moment a leakage fault is detected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component that must be installed and connected by a licensed electrician in accordance with local wiring regulations. Incorrect installation of an RCCB can leave circuits without leakage protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit a standard Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eYes. The CDC264J is part of Hager's modular DIN-rail range and installs alongside Hager MCBs, isolators, and other DB accessories in a standard Hager consumer unit or distribution board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797544083555,"sku":"CDC264J","price":212.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CDC264J_cd1a618f-efd6-49a1-8608-93917dc6971a.webp?v=1786954798"},{"product_id":"hager-rccb-40a-2p-30ma","title":"Hager CDC241J RCCB 40A 2-Pole 30mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003cp\u003eThe Hager CDC241J RCCB (ELCB) 40A, 2P, 30mA delivers reliable earth-leakage protection for people and equipment. With a fast-acting trip and 30mA sensitivity, it suits UAE residential, commercial, and light industrial installations.\u003c\/p\u003e \u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e2-pole RCCB\/ELCB, 40A rated current\u003c\/li\u003e \u003cli\u003e30 mA earth-leakage sensitivity for enhanced personal safety\u003c\/li\u003e \u003cli\u003eFast-acting trip mechanism for rapid disconnection\u003c\/li\u003e \u003cli\u003eCompact, durable design for modular electrical panels\u003c\/li\u003e \u003cli\u003eIEC-compliant protection suitable for UAE electrical projects\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCDC241J\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003cp\u003eDatasheets: Download PDF\u003c\/p\u003e \u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eResidential properties: apartments, villas\u003c\/li\u003e \u003cli\u003eCommercial spaces: offices, schools, retail stores\u003c\/li\u003e \u003cli\u003eLight industrial power distribution panels\u003c\/li\u003e \u003cli\u003eElectrical panels requiring 30 mA protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an RCCB and an MCB?\u003c\/strong\u003e\u003cbr\u003eAn RCCB (ELCB) detects earth leakage current and disconnects the circuit to protect against electric shock — it does not protect against overload or short-circuit current. It's normally installed alongside MCBs, which handle overload and short-circuit protection; the two work together, not as substitutes for each other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30mA rating mean, and do I need this sensitivity?\u003c\/strong\u003e\u003cbr\u003e30mA is the sensitivity required for personal shock protection on socket outlet and bathroom circuits per most wiring regulations. If you're unsure which sensitivity your board needs, an electrician can confirm from the circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole unit, suited to a single-phase circuit (with neutral switched). Match the pole count to your incoming supply and the circuit(s) you're protecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — an RCCB is installed inside a distribution board and connected to live busbars. This must be done by a licensed electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797544116323,"sku":"CDC241J","price":153.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CDC241J.webp?v=1786954879"},{"product_id":"hager-rccb-40a-4p-100ma","title":"Hager CEC441J RCCB 40A 4-Pole 100mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CEC441J RCCB 40A 4-Pole 100mA Type AC – ELCB, Made in France\u003c\/h2\u003e\n\u003cp\u003eThe Hager CEC441J is a 4-pole residual current circuit breaker (RCCB\/ELCB) rated 40A with 100mA Type AC sensitivity, built for earth-leakage protection on UAE distribution boards in residential, commercial and light-industrial installations. Manufactured in France to IEC 61008-1, it combines fast leakage tripping with long-term mechanical reliability in standard DIN-rail enclosures.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated current 40A across 4 poles (4P), suited to three-phase-plus-neutral distribution circuits\u003c\/li\u003e\n\u003cli\u003eRated residual operating current (sensitivity): 100mA, Type AC — for equipment and fire protection on sub-main\/distribution circuits\u003c\/li\u003e\n\u003cli\u003eRated operational voltage 240\/415V AC, 50Hz\u003c\/li\u003e\n\u003cli\u003eRated conditional short-circuit current (Inc) 6kA to EN\/IEC 61008-1; breaking and opening capacity 1500A\u003c\/li\u003e\n\u003cli\u003eCompact DIN-rail mounting, 4 modules wide (70 x 83 x 70mm), screw terminals\u003c\/li\u003e\n\u003cli\u003eIP20 protection rating; rated insulation voltage 500V, impulse withstand 4000V\u003c\/li\u003e\n\u003cli\u003eMechanical endurance 4000 operations, electrical endurance 2000 cycles\u003c\/li\u003e\n\u003cli\u003eRated operating temperature -25°C to 40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCEC441J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100mA, Type AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e240\/415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking\/Opening Capacity\u003c\/td\u003e\n\u003ctd\u003e1500A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current (Inc)\u003c\/td\u003e\n\u003ctd\u003e6kA (EN\/IEC 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting \/ Width\u003c\/td\u003e\n\u003ctd\u003eDIN rail, 4 modules (70mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e70 x 83 x 70mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical \/ Electrical Endurance\u003c\/td\u003e\n\u003ctd\u003e4000 operations \/ 2000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential buildings and villas\u003c\/li\u003e\n\u003cli\u003eCommercial projects: offices, shops, schools, hospitals\u003c\/li\u003e\n\u003cli\u003eLight industrial power distribution systems\u003c\/li\u003e\n\u003cli\u003eInstallations requiring medium-sensitivity earth leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/ELCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (Miniature Circuit Breaker) protects against overload and short-circuit faults. An RCCB\/ELCB like the CEC441J monitors earth leakage current and trips on imbalance, protecting against electric shock and earth faults that an MCB cannot detect. They serve different protection functions and are often installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003eThe CEC441J trips when it detects a 100mA (0.1A) imbalance between live and neutral conductors. 100mA sensitivity is set for equipment and fire protection on distribution\/sub-main circuits, rather than the 30mA rating used for direct personnel shock protection on final circuits — it is typically paired with 30mA RCCBs\/RCBOs further downstream for full protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need — what does 4-pole (4P) mean for this circuit?\u003c\/strong\u003e\u003cbr\u003e4-pole means the device switches all four conductors of a three-phase-plus-neutral supply (3P+N). Use a 4-pole RCCB on three-phase distribution boards or where the neutral must also be isolated; single-phase circuits typically use a 2-pole (2P) device instead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. The CEC441J is a distribution board component and must be installed and commissioned by a licensed electrician in accordance with UAE wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the short-circuit\/breaking capacity of the CEC441J?\u003c\/strong\u003e\u003cbr\u003eIt has a rated conditional short-circuit current (Inc) of 6kA and a breaking\/opening capacity of 1500A, in line with IEC\/EN 61008-1 requirements — sufficient for typical residential and light-commercial distribution boards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797544149091,"sku":"Cec441J","price":166.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CEC441J.webp?v=1786954796"},{"product_id":"hager-rccb-63a-2p-100ma","title":"Hager CEC264J RCCB 63A 2-Pole 100mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager RCCB (ELCB) 63A 2P 100mA – CEC264J\u003c\/h2\u003e\n\u003cp\u003eThe Hager CEC264J RCCB delivers dependable earth leakage protection for residential, commercial, and light industrial installations. Designed with European precision, it safely disconnects on leakage faults to protect people and equipment.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e63 A rating with 2P (double pole) configuration\u003c\/li\u003e \u003cli\u003eSensitivity: 100 mA for reliable leakage detection\u003c\/li\u003e \u003cli\u003eRCCB \/ ELCB device type with fast tripping response\u003c\/li\u003e \u003cli\u003eCompact design for seamless panel integration\u003c\/li\u003e \u003cli\u003eIEC-standard compliant for UAE installations\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCEC264J\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P (Double Pole)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eTripping\u003c\/td\u003e\n\u003ctd\u003eFast, reliable leakage protection\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eIEC standards\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eCompact panel integration\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eResidential apartments, villas, and housing projects\u003c\/li\u003e \u003cli\u003eCommercial spaces: offices, schools, retail outlets\u003c\/li\u003e \u003cli\u003eLight industrial power distribution\u003c\/li\u003e \u003cli\u003eElectrical systems requiring medium-sensitivity leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an RCCB and an MCB?\u003c\/strong\u003e\u003cbr\u003eAn RCCB (ELCB) detects earth leakage current and disconnects the circuit to protect against electric shock — it does not protect against overload or short-circuit current. It's normally installed alongside MCBs, which handle overload and short-circuit protection; the two work together, not as substitutes for each other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA rating mean, and do I need this sensitivity?\u003c\/strong\u003e\u003cbr\u003e100mA sensitivity is typically used for fire protection on distribution or fixed-appliance circuits, rather than direct personal shock protection — check your circuit's requirement before ordering. If you're unsure which sensitivity your board needs, an electrician can confirm from the circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole unit, suited to a single-phase circuit (with neutral switched). Match the pole count to your incoming supply and the circuit(s) you're protecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — an RCCB is installed inside a distribution board and connected to live busbars. This must be done by a licensed electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797544280163,"sku":"CEC264J","price":167.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CEC264J.png?v=1786954787"},{"product_id":"hager-rccb-100a-4p-300ma","title":"Hager CF485Z RCCB 100A 4-Pole 300mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CF485Z RCCB 100A 4-Pole 300mA Type AC – ELCB, Made in France\u003c\/h2\u003e\n\u003cp\u003eThe Hager CF485Z is a high-capacity 4-pole residual current circuit breaker (RCCB\/ELCB) rated 100A with 300mA Type AC sensitivity, built for earth-leakage protection on heavy-duty distribution boards in residential, commercial and industrial installations across the UAE. Manufactured in France to EN 61008-1, it combines fast leakage tripping with a long service life in standard DIN-rail switchboards.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated current 100A across 4 poles (4P), suited to three-phase-plus-neutral distribution circuits\u003c\/li\u003e\n\u003cli\u003eRated residual operating current (sensitivity): 300mA, Type AC — for fire and equipment protection on incoming supply\/sub-main circuits\u003c\/li\u003e\n\u003cli\u003eRated conditional short-circuit current (Inc) 6kA to EN 61008-1; breaking and opening capacity 1.5kA\u003c\/li\u003e\n\u003cli\u003eCompact DIN-rail mounting, 4 modules wide (70 x 86 x 70mm), screw terminals\u003c\/li\u003e\n\u003cli\u003eIP20 protection rating; rated frequency 50Hz\u003c\/li\u003e\n\u003cli\u003eLow power loss: 30.2W total at rated current (11.9W per pole)\u003c\/li\u003e\n\u003cli\u003eMechanical endurance 4000 operations, electrical endurance 2000 cycles\u003c\/li\u003e\n\u003cli\u003eRated operating temperature -25°C to 40°C, derated at higher ambient temperatures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCF485Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e300mA, Type AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking\/Opening Capacity\u003c\/td\u003e\n\u003ctd\u003e1.5kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current (Inc)\u003c\/td\u003e\n\u003ctd\u003e6kA (EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstand Non-Tripping Surge\u003c\/td\u003e\n\u003ctd\u003e0.25kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e30.2W total \/ 11.9W per pole at rated current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting \/ Width\u003c\/td\u003e\n\u003ctd\u003eDIN rail, 4 modules (70mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e70 x 86 x 70mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical \/ Electrical Endurance\u003c\/td\u003e\n\u003ctd\u003e4000 operations \/ 2000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to 40°C (derated to 59A at 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Altitude \/ Pollution Degree\u003c\/td\u003e\n\u003ctd\u003e2000m \/ Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eEN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial distribution panels and switchgear\u003c\/li\u003e\n\u003cli\u003eCommercial buildings: malls, offices, hospitals, schools\u003c\/li\u003e\n\u003cli\u003eLarge residential complexes and villas\u003c\/li\u003e\n\u003cli\u003eProjects requiring high-capacity, heavy-duty leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/ELCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects against overload and short-circuit faults. An RCCB\/ELCB like the CF485Z monitors earth leakage current and trips on imbalance, protecting against electric shock and earth faults an MCB cannot detect. The two are complementary and commonly installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 300mA sensitivity rating mean — will it protect against electric shock?\u003c\/strong\u003e\u003cbr\u003eThe CF485Z trips at a 300mA earth-leakage imbalance. This is a fire\/equipment-protection sensitivity — typically used as main incoming or sub-main protection on larger boards — rather than the 30mA rating required for direct personnel shock protection on final circuits, which should use separate 30mA RCCBs\/RCBOs downstream.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need — what does 4-pole (4P) mean for this circuit?\u003c\/strong\u003e\u003cbr\u003e4-pole means the device switches all four conductors of a three-phase-plus-neutral supply. Use a 4-pole RCCB on three-phase boards or where neutral isolation is required; single-phase circuits typically use a 2-pole device instead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. The CF485Z is a distribution board\/panel component rated up to 100A and must be installed and commissioned by a licensed electrician in accordance with UAE wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat size board or application is the 100A CF485Z suited for?\u003c\/strong\u003e\u003cbr\u003eIts 100A rating and 6kA short-circuit rating make it suitable for main incoming protection on larger residential complexes, commercial buildings and light-industrial distribution boards where high-capacity earth-leakage protection is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797544837219,"sku":"CF485Z","price":353.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CF485Z.webp?v=1786954880"},{"product_id":"hager-63a-2p-300ma-elcb-rccb","title":"Hager CFC264J RCCB 63A 2-Pole 300mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager 63A 2P 300mA ELCB\/RCCB CFC264J\u003c\/h2\u003e\n\u003cp\u003eEnsure reliable earth leakage protection in UAE installations with the Hager CFC264J ELCB\/RCCB. This 2-pole device delivers robust fault protection with a 300 mA residual current rating, safeguarding electrical systems against earth faults.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCurrent rating: 63 A\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n\u003cli\u003eRated residual operating current: 300 mA\u003c\/li\u003e\n\u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n\u003cli\u003eCompliance: IEC 61008-1\u003c\/li\u003e\n\u003cli\u003eBrand: Hager\u003c\/li\u003e\n\u003cli\u003eType: Standard Circuit Breaker\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCFC264J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent rating\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated residual current\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eIEC 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential distribution boards requiring earth leakage protection\u003c\/li\u003e\n\u003cli\u003eCommercial facilities needing robust RCCB protection for critical circuits\u003c\/li\u003e\n\u003cli\u003eSafety-conscious installations where leakage protection reduces shock risk\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an RCCB and an MCB?\u003c\/strong\u003e\u003cbr\u003eAn RCCB (ELCB) detects earth leakage current and disconnects the circuit to protect against electric shock — it does not protect against overload or short-circuit current. It's normally installed alongside MCBs, which handle overload and short-circuit protection; the two work together, not as substitutes for each other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 300mA rating mean, and do I need this sensitivity?\u003c\/strong\u003e\u003cbr\u003e300mA sensitivity is typically used for fire protection on distribution or fixed-appliance circuits, rather than direct personal shock protection — check your circuit's requirement before ordering. If you're unsure which sensitivity your board needs, an electrician can confirm from the circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole unit, suited to a single-phase circuit (with neutral switched). Match the pole count to your incoming supply and the circuit(s) you're protecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — an RCCB is installed inside a distribution board and connected to live busbars. This must be done by a licensed electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797545328739,"sku":"CFC264J","price":129.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CFC264J.webp?v=1786954880"},{"product_id":"hager-onekonekt-rccb-25a-4p-100ma","title":"Hager CEC426J Onekonekt RCCB 25A 4-Pole 100mA Type AC — ELCB","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CEC426J Onekonekt RCCB 25A 4-Pole 100mA Type AC – ELCB\u003c\/h2\u003e\n\u003cp\u003eThe Hager CEC426J is a 25A, 4-pole residual current circuit breaker (RCCB\/ELCB) with 100mA Type AC sensitivity from Hager's Onekonekt range, built for earth-leakage protection on UAE distribution boards in residential and light-commercial installations. Its bottom terminal is a bi-connect design that accepts either cables or Hager's Onekonekt busbar system, letting electricians wire panels faster while still working exactly like a standard screw terminal when a busbar isn't used.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated current 25A across 4 poles (3P+N), for three-phase-plus-neutral distribution circuits\u003c\/li\u003e\n\u003cli\u003eRated residual operating current (sensitivity): 100mA, Type AC — for equipment protection on distribution circuits\u003c\/li\u003e\n\u003cli\u003eRated operational voltage 240\/415V AC, 50Hz\u003c\/li\u003e\n\u003cli\u003eOnekonekt bi-connect bottom terminal accepts either cables or a Hager busbar, with a screw top terminal\u003c\/li\u003e\n\u003cli\u003eRated conditional short-circuit current (Inc) 6kA to EN 61008-1; breaking capacity 1.5kA\u003c\/li\u003e\n\u003cli\u003eWide conductor range: 1–25mm² solid \/ 1–16mm² flexible, tightening torque 2.8Nm\u003c\/li\u003e\n\u003cli\u003eCompact DIN-rail mounting, 4 modules wide (70 x 83 x 70mm); IP20 protection\u003c\/li\u003e\n\u003cli\u003eMechanical endurance 4000 operations, electrical endurance 2000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries \/ Model\u003c\/td\u003e\n\u003ctd\u003eOnekonekt CEC426J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P (3P+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100mA, Type AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e240\/415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Idm)\u003c\/td\u003e\n\u003ctd\u003e1.5kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current (Inc)\u003c\/td\u003e\n\u003ctd\u003e6kA (EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew top \/ Onekonekt bi-connect bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Range\u003c\/td\u003e\n\u003ctd\u003e1–25mm² solid, 1–16mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting \/ Width\u003c\/td\u003e\n\u003ctd\u003eDIN rail, 4 modules (70mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e70 x 83 x 70mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical \/ Electrical Endurance\u003c\/td\u003e\n\u003ctd\u003e4000 operations \/ 2000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to 60°C rated (derated to 18A at 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN 61008-1 \/ IEC safety standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential homes and villas\u003c\/li\u003e\n\u003cli\u003eCommercial spaces: offices, schools, healthcare facilities\u003c\/li\u003e\n\u003cli\u003eIndustrial power distribution systems\u003c\/li\u003e\n\u003cli\u003eProjects requiring medium-sensitivity earth leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/ELCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects against overload and short-circuit faults. An RCCB\/ELCB like the CEC426J monitors earth leakage current and trips on imbalance, protecting against electric shock and earth faults an MCB cannot detect. The two are complementary and commonly fitted together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003eThe CEC426J trips at a 100mA earth-leakage imbalance, a sensitivity set for equipment and fire protection on distribution circuits rather than the 30mA rating used for direct personnel shock protection on final circuits — pair it with 30mA RCCBs\/RCBOs downstream where personnel protection is required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need — what does 4-pole (3P+N) mean for this circuit?\u003c\/strong\u003e\u003cbr\u003e4-pole (3 phase + neutral) means the device switches all four conductors of a three-phase supply, including the neutral. Use it on three-phase distribution boards; single-phase circuits typically use a 2-pole device instead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. The CEC426J is a distribution board component and must be installed and commissioned by a licensed electrician in accordance with UAE wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is Onekonekt, and can I still wire this with standard cables?\u003c\/strong\u003e\u003cbr\u003eOnekonekt is Hager's bi-connect terminal and busbar system for modular protection devices. The CEC426J's bottom terminal accepts either standard cables in the terminal cage or a Hager Onekonekt busbar — busbars simply speed up panel wiring on multi-way boards, and standard cable connection works exactly as normal when a busbar isn't used.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797545394275,"sku":"CEC426J","price":171.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CEC426J.webp?v=1786954796"},{"product_id":"hager-rccb-100a-2p-300ma","title":"Hager CF285Z RCCB 100A 2-Pole 300mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CF285Z RCCB 100A 2-Pole 300mA Type AC — ELCB\u003c\/h2\u003e\n\u003cp\u003eThe Hager RCCB (ELCB) 100A 2-Pole 300mA – CF285Z delivers reliable protection against earth leakage faults, safeguarding both people and electrical installations. Made in France and built to IEC 61008-1, this high-current residual current device is designed for demanding residential, commercial, and industrial distribution boards where fire and equipment protection at the incomer or sub-main level is required.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: \u003cstrong\u003eHager\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel: \u003cstrong\u003eCF285Z\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRated Current: \u003cstrong\u003e100A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePoles: \u003cstrong\u003e2P (Double Pole)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSensitivity: \u003cstrong\u003e300mA, Type AC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDevice Type: RCCB \/ ELCB (Earth Leakage Circuit Breaker)\u003c\/li\u003e\n\u003cli\u003eFast tripping response to leakage currents\u003c\/li\u003e\n\u003cli\u003eRobust construction for demanding, high-current applications\u003c\/li\u003e\n\u003cli\u003eComplies with IEC 61008-1 for global safety assurance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCF285Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Residual Operating Current (IΔn)\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Type\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking\/Opening Capacity\u003c\/td\u003e\n\u003ctd\u003e1500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current (Inc, per EN 61008-1)\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Withstand (8\/20 µs wave, non-tripping)\u003c\/td\u003e\n\u003ctd\u003e0.25 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e14.3 W total (7.6 W per pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e83 x 35 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Width\u003c\/td\u003e\n\u003ctd\u003e2 modules (DIN 43880 size 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail, type O (symmetrical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Index\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\/Transport Temperature\u003c\/td\u003e\n\u003ctd\u003e-55°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e2 (IEC 60664 \/ IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Endurance\u003c\/td\u003e\n\u003ctd\u003e4000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Endurance\u003c\/td\u003e\n\u003ctd\u003e2000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential apartment blocks and villas\u003c\/li\u003e\n\u003cli\u003eCommercial facilities: offices, shops, schools\u003c\/li\u003e\n\u003cli\u003eIndustrial power distribution systems\u003c\/li\u003e\n\u003cli\u003eAny high-current circuit requiring earth leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (Miniature Circuit Breaker) protects a circuit against overload and short-circuit faults. An RCCB (Residual Current Circuit Breaker), also known as an ELCB, continuously monitors for earth leakage current and disconnects the supply if current is escaping to earth – protecting against electric shock and fire in a way an MCB cannot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 300mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e300mA is a higher-sensitivity threshold aimed at fire and equipment protection rather than personal shock protection (which typically needs 30mA). The CF285Z is best used as a main incomer or sub-main device protecting large distribution circuits, with 30mA RCCBs\/RCBOs used further downstream on final circuits for personnel protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need for this circuit?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole (2P) device, switching both line and neutral. It is intended for single-phase distribution boards and incomers; three-phase boards require a 4-pole equivalent.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution-board-mounted device and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the CF285Z suitable as a main switch\/incomer for a large board?\u003c\/strong\u003e\u003cbr\u003eYes – at 100A with 300mA sensitivity and a 6kA rated conditional short-circuit current, it is designed for high-load main or sub-main incomer protection on residential, commercial, and industrial boards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797545427043,"sku":"CF285Z","price":255.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CF285Z.webp?v=1786954793"},{"product_id":"hager-rccb-100a-4p-30ma","title":"Hager CD485Z RCCB 100A 4-Pole 30mA Type AC — ELCB Made in France","description":"\u003cdiv\u003eThe Hager RCCB (ELCB) CD485Z delivers robust earth-leakage protection for high-load electrical systems. With a 100A rating and 4 poles, it safeguards people and equipment from dangerous earth faults in residential, commercial, and industrial installations across the UAE. \u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e4P design for comprehensive line and neutral protection\u003c\/li\u003e \u003cli\u003e30 mA residual current sensitivity for enhanced personal safety\u003c\/li\u003e \u003cli\u003eFast disconnection on earth leakage faults to minimize risk\u003c\/li\u003e \u003cli\u003e100A rated current, ideal for heavy-duty applications\u003c\/li\u003e \u003cli\u003eEuropean build quality for demanding environments\u003c\/li\u003e \u003cli\u003eIEC standards-compliant protection\u003c\/li\u003e \u003cli\u003eSuitable for industrial control panels, distribution boards, and large-scale installations\u003c\/li\u003e \u003cli\u003eAvailable with fast UAE-wide delivery from Deluxe Electricals\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003eElectrical characteristics\u003c\/h3\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCD485Z\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC compliant\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eIndustrial control panels and distribution boards\u003c\/li\u003e \u003cli\u003eCommercial buildings such as malls, offices, and schools\u003c\/li\u003e \u003cli\u003eLarge residential complexes with high electrical load\u003c\/li\u003e \u003cli\u003eAny high-load installation requiring reliable earth leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an RCCB and an MCB?\u003c\/strong\u003e\u003cbr\u003eAn RCCB (ELCB) detects earth leakage current and disconnects the circuit to protect against electric shock — it does not protect against overload or short-circuit current. It's normally installed alongside MCBs, which handle overload and short-circuit protection; the two work together, not as substitutes for each other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30mA rating mean, and do I need this sensitivity?\u003c\/strong\u003e\u003cbr\u003e30mA is the sensitivity required for personal shock protection on socket outlet and bathroom circuits per most wiring regulations. If you're unsure which sensitivity your board needs, an electrician can confirm from the circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 4-pole unit, suited to a three-phase circuit. Match the pole count to your incoming supply and the circuit(s) you're protecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — an RCCB is installed inside a distribution board and connected to live busbars. This must be done by a licensed electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797546082403,"sku":"CD485Z","price":391.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CD485Z.webp?v=1786954793"},{"product_id":"hager-onekonekt-rccb-25a-2p-30ma","title":"Hager CDC226J Onekonekt RCCB 25A 2-Pole 30mA Type AC — ELCB","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CDC226J Onekonekt RCCB 25A 2-Pole 30mA Type AC — ELCB\u003c\/h2\u003e\n\u003cp\u003eThe Hager Onekonekt RCCB (ELCB) 25A 2-Pole 30mA – CDC226J offers reliable protection against earth leakage currents, safeguarding both people and electrical systems. Part of Hager's Onekonekt modular protection range and engineered to European quality standards, this breaker ensures fast, reliable disconnection to prevent electric shocks and fire hazards on residential and light commercial final circuits.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: \u003cstrong\u003eHager – Onekonekt Series\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel: \u003cstrong\u003eCDC226J\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRated Current: \u003cstrong\u003e25A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePoles: \u003cstrong\u003e2P (Double Pole)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSensitivity: \u003cstrong\u003e30mA, Type AC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDevice Type: Residual Current Circuit Breaker (RCCB \/ ELCB)\u003c\/li\u003e\n\u003cli\u003eEnsures personal safety by cutting power during leakage faults\u003c\/li\u003e\n\u003cli\u003eCompact design for easy installation in panels and consumer units\u003c\/li\u003e\n\u003cli\u003eBuilt to IEC standards for global compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCDC226J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eOnekonekt – Hager's unified modular protection range, compatible with Hager single\/three-phase busbars\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e2P (1P+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Residual Operating Current (IΔn)\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Type\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e4,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e1.5 kA (1500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e83 x 35 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Width\u003c\/td\u003e\n\u003ctd\u003e2 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminal (BIconnect bottom connection, busbar-compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Capacity\u003c\/td\u003e\n\u003ctd\u003e1–25 mm² solid \/ 1–16 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Index\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e2.32 W at rated current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Endurance\u003c\/td\u003e\n\u003ctd\u003e4000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Endurance\u003c\/td\u003e\n\u003ctd\u003e2000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Derating\u003c\/td\u003e\n\u003ctd\u003eRated 25 A up to 65°C ambient; derates to 21 A at 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential properties (apartments, villas)\u003c\/li\u003e\n\u003cli\u003eOffices, shops, and commercial spaces\u003c\/li\u003e\n\u003cli\u003eSchools, healthcare facilities, and public buildings\u003c\/li\u003e\n\u003cli\u003eLight industrial panels and projects requiring high safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (Miniature Circuit Breaker) protects a circuit against overload and short-circuit faults. An RCCB (Residual Current Circuit Breaker), also known as an ELCB, continuously monitors for earth leakage current and disconnects the supply if current is escaping to earth – protecting against electric shock and fire in a way an MCB cannot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e30mA is the internationally recognised threshold for personnel protection against electric shock, making the CDC226J suitable for final circuits – sockets, lighting, and general power – where there is direct risk of human contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need for this circuit?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole (2P, 1P+N) device switching both line and neutral, suited to single-phase circuits. Three-phase circuits require a 4-pole equivalent.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution-board-mounted device and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is Onekonekt?\u003c\/strong\u003e\u003cbr\u003eOnekonekt is Hager's unified range of modular protection devices – MCBs, RCCBs, RCBOs, and main switches – designed to fit a common single- or three-phase busbar system with BIconnect terminals, so devices can be wired from cables or fed directly from the busbar, speeding up panel-building and reducing wiring errors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797546147939,"sku":"CDC226J","price":122.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CDC226J.webp?v=1786954791"},{"product_id":"hager-onekonekt-rccb-16a-2p-10ma","title":"Hager CCC217J Onekonekt RCCB 16A 2-Pole 10mA Type AC — ELCB","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CCC217J Onekonekt RCCB 16A 2-Pole 10mA Type AC — ELCB\u003c\/h2\u003e\n\u003cp\u003eThe Hager Onekonekt RCCB (ELCB) 16A 2-Pole 10mA – CCC217J provides advanced, high-sensitivity earth-leakage protection for residential, commercial, and light industrial applications. Designed to disconnect the circuit the instant leakage current is detected, this RCCB is built for locations where an extra margin of shock protection is needed, beyond the standard 30mA threshold.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: \u003cstrong\u003eHager – Onekonekt Series\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel: \u003cstrong\u003eCCC217J\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRated Current: \u003cstrong\u003e16A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePoles: \u003cstrong\u003e2P (Double Pole)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSensitivity: \u003cstrong\u003e10mA, Type AC (high-sensitivity)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eFunction: Residual Current Circuit Breaker (RCCB \/ ELCB)\u003c\/li\u003e\n\u003cli\u003eFast and reliable disconnection on earth-leakage faults\u003c\/li\u003e\n\u003cli\u003eCompact design for easy panel integration\u003c\/li\u003e\n\u003cli\u003eComplies with IEC 61008-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCCC217J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eOnekonekt – Hager's unified modular protection range, compatible with Hager single\/three-phase busbars\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Residual Operating Current (IΔn)\u003c\/td\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Type\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e1500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e83 x 35 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Width\u003c\/td\u003e\n\u003ctd\u003e2 modules (DIN 43880 size 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminal (BIconnect bottom connection, busbar-compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Capacity\u003c\/td\u003e\n\u003ctd\u003e1–25 mm² rigid \/ 1–16 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Index\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\/Transport Temperature\u003c\/td\u003e\n\u003ctd\u003e-55°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Endurance\u003c\/td\u003e\n\u003ctd\u003e4000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Endurance\u003c\/td\u003e\n\u003ctd\u003e2000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliant\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential apartments and villas\u003c\/li\u003e\n\u003cli\u003eCommercial buildings, offices, and shops\u003c\/li\u003e\n\u003cli\u003eEducational and healthcare facilities\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels requiring high safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (Miniature Circuit Breaker) protects a circuit against overload and short-circuit faults. An RCCB (Residual Current Circuit Breaker), also known as an ELCB, continuously monitors for earth leakage current and disconnects the supply if current is escaping to earth – protecting against electric shock and fire in a way an MCB cannot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10mA sensitivity rating mean, and why is it so low?\u003c\/strong\u003e\u003cbr\u003e10mA is a specialist high-sensitivity rating, well below the standard 30mA personnel-protection threshold. RCCBs at this sensitivity are typically specified for locations needing an extra safety margin – such as medical equipment supplies, bathrooms\/wet areas, swimming pools, or sensitive electronic loads – where standard 30mA protection is not considered enough. Note: the manufacturer datasheet confirms the 10mA rating itself but does not name a specific end-use; the examples above reflect standard industry practice for this sensitivity class.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need for this circuit?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole (2P) device switching both line and neutral, suited to single-phase circuits. Three-phase circuits require a 4-pole equivalent.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution-board-mounted device and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is Onekonekt?\u003c\/strong\u003e\u003cbr\u003eOnekonekt is Hager's unified range of modular protection devices – MCBs, RCCBs, RCBOs, and main switches – designed to fit a common single- or three-phase busbar system with BIconnect terminals, so devices can be wired from cables or fed directly from the busbar, speeding up panel-building and reducing wiring errors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797546868835,"sku":"CCC217J","price":244.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CCC217J.webp?v=1786954888"},{"product_id":"hager-esc225-25a-2-pole-installation-contactor-230v-ac","title":"Hager ESC225 25A 2-Pole Installation Contactor 230V AC","description":"\u003ch2\u003eHager ESC225 25A 2-Pole Installation Contactor 230V AC\u003c\/h2\u003e\u003cp\u003eThe Hager ESC225 is a 25A 2-pole installation contactor with a 230V AC coil for lighting, heating, and general load switching in UAE residential and commercial distribution boards. Compact and reliable, it is ideal for timer-controlled and BMS-controlled circuit switching.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e25A 2-pole installation contactor for single-phase load switching\u003c\/li\u003e\n\u003cli\u003e230V AC 50\/60Hz coil for UAE standard panel supply\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting for DB installation\u003c\/li\u003e\n\u003cli\u003eSuitable for lighting, heating, and general switching\u003c\/li\u003e\n\u003cli\u003eGenuine Hager contactor quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eESC225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e230V AC 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLighting circuit control in residential and commercial buildings\u003c\/li\u003e\n\u003cli\u003eHeating and HVAC load switching\u003c\/li\u003e\n\u003cli\u003eTimer and BMS-controlled switching\u003c\/li\u003e\n\u003cli\u003eBuilding services distribution panel applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is an installation contactor used for?\u003c\/strong\u003e\u003cbr\u003eA contactor switches a circuit remotely or automatically in response to a control signal — commonly used for lighting, heating, or HVAC loads controlled by a time switch, sensor, or building management system, rather than a manual switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole, 25A unit. Match the pole count to the circuit being switched — single-phase loads need the corresponding pole count.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — a contactor is wired into a distribution board alongside its control circuit and must be installed by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be paired with a time switch?\u003c\/strong\u003e\u003cbr\u003eYes — pairing a contactor with a Hager time switch (e.g. the EHN range) is a common way to give a manually-rated circuit automated, scheduled control without exceeding the time switch's own contact rating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163344072803,"sku":"ESC225","price":60.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/ESC225.webp?v=1786966496"},{"product_id":"hager-esc240-40a-2-pole-installation-contactor-230v-ac","title":"Hager ESC240 40A 2-Pole Installation Contactor 230V AC","description":"\u003ch2\u003eHager ESC240 40A 2-Pole Installation Contactor 230V AC\u003c\/h2\u003e\u003cp\u003eThe Hager ESC240 is a 40A 2-pole installation contactor with a 230V AC coil for higher-current lighting, heating, and general load switching in UAE commercial and residential distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e40A 2-pole installation contactor\u003c\/li\u003e\n\u003cli\u003e230V AC 50\/60Hz coil\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eESC240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e230V AC 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCommercial lighting and power circuit control\u003c\/li\u003e\n\u003cli\u003eHeating and HVAC load switching\u003c\/li\u003e\n\u003cli\u003eTimer and BMS-controlled circuit switching\u003c\/li\u003e\n\u003cli\u003eBuilding services panel load management\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is an installation contactor used for?\u003c\/strong\u003e\u003cbr\u003eA contactor switches a circuit remotely or automatically in response to a control signal — commonly used for lighting, heating, or HVAC loads controlled by a time switch, sensor, or building management system, rather than a manual switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole, 40A unit. Match the pole count to the circuit being switched — single-phase loads need the corresponding pole count.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — a contactor is wired into a distribution board alongside its control circuit and must be installed by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be paired with a time switch?\u003c\/strong\u003e\u003cbr\u003eYes — pairing a contactor with a Hager time switch (e.g. the EHN range) is a common way to give a manually-rated circuit automated, scheduled control without exceeding the time switch's own contact rating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163345285219,"sku":"ESC240","price":95.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/ESC240.webp?v=1786966498"},{"product_id":"hager-esc340-40a-3-pole-installation-contactor-230v-ac","title":"Hager ESC340 40A 3-Pole Installation Contactor 230V AC","description":"\u003ch2\u003eHager ESC340 40A 3-Pole Installation Contactor 230V AC\u003c\/h2\u003e\u003cp\u003eThe Hager ESC340 is a 40A 3-pole installation contactor with a 230V AC coil for three-phase load switching in UAE commercial and industrial buildings. Suitable for lighting, HVAC, and general three-phase load management from DIN-rail panels.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e40A 3-pole installation contactor for three-phase switching\u003c\/li\u003e\n\u003cli\u003e230V AC 50\/60Hz coil\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eESC340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e230V AC 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThree-phase lighting and general load control\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial building services switching\u003c\/li\u003e\n\u003cli\u003eTimer and BMS-controlled three-phase switching\u003c\/li\u003e\n\u003cli\u003eHVAC and distribution panel applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is an installation contactor used for?\u003c\/strong\u003e\u003cbr\u003eA contactor switches a circuit remotely or automatically in response to a control signal — commonly used for lighting, heating, or HVAC loads controlled by a time switch, sensor, or building management system, rather than a manual switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole, 40A unit. Match the pole count to the circuit being switched — three-phase loads need the corresponding pole count.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — a contactor is wired into a distribution board alongside its control circuit and must be installed by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be paired with a time switch?\u003c\/strong\u003e\u003cbr\u003eYes — pairing a contactor with a Hager time switch (e.g. the EHN range) is a common way to give a manually-rated circuit automated, scheduled control without exceeding the time switch's own contact rating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163345317987,"sku":"ESC340","price":97.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/ESC340.webp?v=1786966499"},{"product_id":"hager-esc440-40a-4-pole-installation-contactor-230v-ac","title":"Hager ESC440 40A 4-Pole Installation Contactor 230V AC","description":"\u003ch2\u003eHager ESC440 40A 4-Pole Installation Contactor 230V AC\u003c\/h2\u003e\u003cp\u003eThe Hager ESC440 is a 40A 4-pole installation contactor with a 230V AC coil for three-phase + neutral load switching in UAE commercial and industrial buildings. Suitable for four-wire lighting, HVAC, and general load management panels.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e40A 4-pole installation contactor for 3-phase + neutral switching\u003c\/li\u003e\n\u003cli\u003e230V AC 50\/60Hz coil\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eESC440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e230V AC 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFour-wire three-phase load switching in commercial DBs\u003c\/li\u003e\n\u003cli\u003eBuilding services and HVAC circuit control\u003c\/li\u003e\n\u003cli\u003eTimer and BMS-controlled four-pole switching\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial building load management\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is an installation contactor used for?\u003c\/strong\u003e\u003cbr\u003eA contactor switches a circuit remotely or automatically in response to a control signal — commonly used for lighting, heating, or HVAC loads controlled by a time switch, sensor, or building management system, rather than a manual switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 4-pole, 40A unit. Match the pole count to the circuit being switched — three-phase loads need the corresponding pole count.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — a contactor is wired into a distribution board alongside its control circuit and must be installed by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be paired with a time switch?\u003c\/strong\u003e\u003cbr\u003eYes — pairing a contactor with a Hager time switch (e.g. the EHN range) is a common way to give a manually-rated circuit automated, scheduled control without exceeding the time switch's own contact rating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163347087459,"sku":"ESC440","price":135.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/ESC440.webp?v=1786966501"},{"product_id":"hager-esc463-63a-4-pole-installation-contactor-230v-ac","title":"Hager ESC463 63A 4-Pole Installation Contactor 230V AC","description":"\u003ch2\u003eHager ESC463 63A 4-Pole Installation Contactor 230V AC\u003c\/h2\u003e\n\u003cp\u003eThe Hager ESC463 is a 63A 4-pole installation contactor with a 230V AC coil for high-current three-phase + neutral load switching in UAE commercial and industrial buildings. Ideal for large lighting, HVAC, and power load management in four-wire panels.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e63A 4-pole installation contactor for 3-phase + neutral high-current switching\u003c\/li\u003e\n\u003cli\u003e230V AC 50\/60Hz coil\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager ESC quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 99.9215%; height: 156.818px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003cth style=\"width: 45.1341%; height: 19.6023px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"width: 51.9187%; height: 19.6023px;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 45.1341%; height: 19.6023px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 51.9187%; height: 19.6023px;\"\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 45.1341%; height: 19.6023px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 51.9187%; height: 19.6023px;\"\u003eESC463\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 45.1341%; height: 19.6023px;\"\u003eArticle Number\u003c\/td\u003e\n\u003ctd style=\"width: 51.9187%; height: 19.6023px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 45.1341%; height: 19.6023px;\"\u003eRated Current\u003c\/td\u003e\n\u003ctd style=\"width: 51.9187%; height: 19.6023px;\"\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 45.1341%; height: 19.6023px;\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"width: 51.9187%; height: 19.6023px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 45.1341%; height: 19.6023px;\"\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 51.9187%; height: 19.6023px;\"\u003e230V AC 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 45.1341%; height: 19.6023px;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"width: 51.9187%; height: 19.6023px;\"\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-current four-pole load switching in commercial panels\u003c\/li\u003e\n\u003cli\u003eThree-phase + neutral HVAC and building services control\u003c\/li\u003e\n\u003cli\u003eTimer and BMS-controlled four-wire switching\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial load management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is an installation contactor used for?\u003c\/strong\u003e\u003cbr\u003eA contactor switches a circuit remotely or automatically in response to a control signal — commonly used for lighting, heating, or HVAC loads controlled by a time switch, sensor, or building management system, rather than a manual switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 4-pole, 63A unit. Match the pole count to the circuit being switched — three-phase loads need the corresponding pole count.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — a contactor is wired into a distribution board alongside its control circuit and must be installed by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be paired with a time switch?\u003c\/strong\u003e\u003cbr\u003eYes — pairing a contactor with a Hager time switch (e.g. the EHN range) is a common way to give a manually-rated circuit automated, scheduled control without exceeding the time switch's own contact rating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163347972195,"sku":"ESC463","price":120.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/ESC463.webp?v=1786966503"},{"product_id":"hager-jg340in-40a-3-pole-modular-isolator","title":"Hager JG340IN 40A 3-Pole Modular Isolator","description":"\u003ch2\u003eHager JG340IN 40A 3-Pole Modular Isolator\u003c\/h2\u003e\u003cp\u003eThe Hager JG340IN is a 40A 3-pole modular isolator for main incoming or sub-main isolation in UAE three-phase distribution boards. DIN rail-mountable for integration in standard commercial and industrial panel installations.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e40A 3-pole modular isolator for three-phase incoming isolation\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF indication\u003c\/li\u003e\n\u003cli\u003eGenuine Hager quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eJG340IN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThree-phase main incoming isolation in commercial DBs\u003c\/li\u003e\n\u003cli\u003eSub-main isolation in industrial and commercial panels\u003c\/li\u003e\n\u003cli\u003eFM and maintenance isolation switch\u003c\/li\u003e\n\u003cli\u003ePanel incoming protection replacement\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is a modular isolator used for?\u003c\/strong\u003e\u003cbr\u003eAn isolator provides on-load or off-load disconnection of a circuit for maintenance and safety — it does not provide overload or short-circuit protection like an MCB, so it's typically used alongside protective devices, not instead of them.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole, 40A unit. Match the pole count to what you need to isolate — a three-phase supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — isolators are installed inside a distribution board and connected to live busbars, and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this the same as a main switch?\u003c\/strong\u003e\u003cbr\u003eIt's often used as one — a modular isolator of this type is commonly fitted as the main incomer disconnect on a distribution board, or to isolate a sub-circuit for safe maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163349479523,"sku":"JG340IN","price":70.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/JG220U_2.webp?v=1786966505"},{"product_id":"hager-sbn490n-90a-4-pole-modular-isolator","title":"Hager SBN490N 90A 4-Pole Modular Isolator","description":"\u003ch2\u003eHager SBN490N 90A 4-Pole Modular Isolator\u003c\/h2\u003e\u003cp\u003eThe Hager SBN490N is a 90A 4-pole modular isolator for high-current three-phase + neutral main incoming isolation in UAE commercial and industrial distribution boards. Its 90A rating suits larger incoming circuits in commercial buildings and light industrial panels.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e90A 4-pole modular isolator for 3-phase + neutral isolation\u003c\/li\u003e\n\u003cli\u003eHigh-current incoming isolation for commercial and industrial DBs\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSBN490N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e90A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-current main incoming isolation in 4-pole commercial DBs\u003c\/li\u003e\n\u003cli\u003eThree-phase + neutral sub-main isolation\u003c\/li\u003e\n\u003cli\u003eIndustrial and commercial panel incoming switch\u003c\/li\u003e\n\u003cli\u003eFM and maintenance isolation replacement\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is a modular isolator used for?\u003c\/strong\u003e\u003cbr\u003eAn isolator provides on-load or off-load disconnection of a circuit for maintenance and safety — it does not provide overload or short-circuit protection like an MCB, so it's typically used alongside protective devices, not instead of them.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 4-pole, 90A unit. Match the pole count to what you need to isolate — a three-phase supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — isolators are installed inside a distribution board and connected to live busbars, and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this the same as a main switch?\u003c\/strong\u003e\u003cbr\u003eIt's often used as one — a modular isolator of this type is commonly fitted as the main incomer disconnect on a distribution board, or to isolate a sub-circuit for safe maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163349577827,"sku":"SBN490N","price":145.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/SBN490N.webp?v=1786965567"},{"product_id":"hager-jg232in-32a-2-pole-modular-isolator","title":"Hager JG232IN 32A 2-Pole Modular Isolator","description":"\u003ch2\u003eHager JG232IN 32A 2-Pole Modular Isolator\u003c\/h2\u003e\u003cp\u003eThe Hager JG232IN is a 32A 2-pole modular isolator for main incoming or sub-main isolation in UAE single-phase residential and commercial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e32A 2-pole modular isolator for single-phase isolation\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF indication\u003c\/li\u003e\n\u003cli\u003eGenuine Hager quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eJG232IN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMain incoming isolation in residential consumer units\u003c\/li\u003e\n\u003cli\u003eSingle-phase sub-main isolation in commercial DBs\u003c\/li\u003e\n\u003cli\u003eFM and maintenance isolation replacement\u003c\/li\u003e\n\u003cli\u003eConsumer unit main switch\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is a modular isolator used for?\u003c\/strong\u003e\u003cbr\u003eAn isolator provides on-load or off-load disconnection of a circuit for maintenance and safety — it does not provide overload or short-circuit protection like an MCB, so it's typically used alongside protective devices, not instead of them.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole, 32A unit. Match the pole count to what you need to isolate — both live and neutral on a single-phase supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — isolators are installed inside a distribution board and connected to live busbars, and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this the same as a main switch?\u003c\/strong\u003e\u003cbr\u003eIt's often used as one — a modular isolator of this type is commonly fitted as the main incomer disconnect on a distribution board, or to isolate a sub-circuit for safe maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163349643363,"sku":"JG232IN","price":75.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/JG220U.webp?v=1786965569"},{"product_id":"hager-jg240in-40a-2-pole-modular-isolator","title":"Hager JG240IN 40A 2-Pole Modular Isolator","description":"\u003ch2\u003eHager JG240IN 40A 2-Pole Modular Isolator\u003c\/h2\u003e\u003cp\u003eThe Hager JG240IN is a 40A 2-pole modular isolator for main incoming or sub-main isolation in UAE residential and commercial single-phase distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e40A 2-pole modular isolator for single-phase isolation\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF indication\u003c\/li\u003e\n\u003cli\u003eGenuine Hager quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eJG240IN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMain incoming isolation in residential consumer units\u003c\/li\u003e\n\u003cli\u003eSingle-phase sub-main isolation in commercial DBs\u003c\/li\u003e\n\u003cli\u003eFM and maintenance isolation switch replacement\u003c\/li\u003e\n\u003cli\u003eGeneral building incoming isolation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is a modular isolator used for?\u003c\/strong\u003e\u003cbr\u003eAn isolator provides on-load or off-load disconnection of a circuit for maintenance and safety — it does not provide overload or short-circuit protection like an MCB, so it's typically used alongside protective devices, not instead of them.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole, 40A unit. Match the pole count to what you need to isolate — both live and neutral on a single-phase supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — isolators are installed inside a distribution board and connected to live busbars, and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this the same as a main switch?\u003c\/strong\u003e\u003cbr\u003eIt's often used as one — a modular isolator of this type is commonly fitted as the main incomer disconnect on a distribution board, or to isolate a sub-circuit for safe maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163349676131,"sku":"JG240IN","price":70.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/JG220U.webp?v=1786965569"},{"product_id":"hager-mcn120-1-pole-20a-mcb-type-c-6ka","title":"Hager MCN120 1-Pole 20A MCB Type C 6kA","description":"\u003ch2\u003eHager MCN120 1-Pole 20A MCB Type C 6kA\u003c\/h2\u003e\u003cp\u003eThe Hager MCN120 is a 1-pole 20A Type C MCB with 6kA breaking capacity for single-phase circuit protection in UAE residential and commercial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1-pole 20A Type C MCB with 6kA breaking capacity\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eCompact design for DB installation\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MCN quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMCN120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230\/400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSingle-phase circuit protection in residential DBs\u003c\/li\u003e\n\u003cli\u003eLighting and power circuit MCB protection\u003c\/li\u003e\n\u003cli\u003eCommercial distribution board circuit protection\u003c\/li\u003e\n\u003cli\u003eGeneral building services circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Type C\" mean on this MCB?\u003c\/strong\u003e\u003cbr\u003eType C describes the tripping curve — it allows a higher inrush current (roughly 5–10 times the rated current) before tripping on short-circuit, which suits motors, transformers, and other inductive loads that draw a brief high current at switch-on without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA rating mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the breaking capacity — the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 1-pole, 20A unit. Use 1-pole for a single live conductor on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — MCBs are installed inside a distribution board on live busbars and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eGenuine Hager MCBs clip directly onto standard 35mm DIN rail and are designed to work across the Hager DB range — check your board's existing MCB range\/series if you need an exact match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163349708899,"sku":"MCN120","price":23.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MCN120.webp?v=1786965569"},{"product_id":"hager-mw210-2-pole-10a-mcb-type-c-6ka","title":"Hager MW210 2-Pole 10A MCB Type C 6kA","description":"\u003ch2\u003eHager MW210 2-Pole 10A MCB Type C 6kA\u003c\/h2\u003e\u003cp\u003eThe Hager MW210 is a 2-pole 10A Type C MCB with 6kA breaking capacity for double-pole circuit protection in UAE residential and commercial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2-pole 10A Type C MCB, 6kA\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MW quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMW210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230\/400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDouble-pole circuit protection in residential and commercial DBs\u003c\/li\u003e\n\u003cli\u003eLighting and small load double-pole switching\u003c\/li\u003e\n\u003cli\u003eConsumer unit and panel circuit protection\u003c\/li\u003e\n\u003cli\u003eGeneral building services circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Type C\" mean on this MCB?\u003c\/strong\u003e\u003cbr\u003eType C describes the tripping curve — it allows a higher inrush current (roughly 5–10 times the rated current) before tripping on short-circuit, which suits motors, transformers, and other inductive loads that draw a brief high current at switch-on without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA rating mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the breaking capacity — the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole, 10A unit. Use 2-pole to switch both live and neutral on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — MCBs are installed inside a distribution board on live busbars and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eGenuine Hager MCBs clip directly onto standard 35mm DIN rail and are designed to work across the Hager DB range — check your board's existing MCB range\/series if you need an exact match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163349774435,"sku":"MW210","price":60.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MW210.webp?v=1786965572"},{"product_id":"hager-mw220-2-pole-20a-mcb-type-c-6ka","title":"Hager MW220 2-Pole 20A MCB Type C 6kA","description":"\u003ch2\u003eHager MW220 2-Pole 20A MCB Type C 6kA\u003c\/h2\u003e\u003cp\u003eThe Hager MW220 is a 2-pole 20A Type C MCB with 6kA breaking capacity for double-pole circuit protection in UAE residential and commercial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2-pole 20A Type C MCB, 6kA\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MW quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMW220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230\/400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDouble-pole socket and power circuit protection\u003c\/li\u003e\n\u003cli\u003eResidential and commercial DB circuit protection\u003c\/li\u003e\n\u003cli\u003eAppliance and high-load double-pole switching\u003c\/li\u003e\n\u003cli\u003eGeneral building circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Type C\" mean on this MCB?\u003c\/strong\u003e\u003cbr\u003eType C describes the tripping curve — it allows a higher inrush current (roughly 5–10 times the rated current) before tripping on short-circuit, which suits motors, transformers, and other inductive loads that draw a brief high current at switch-on without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA rating mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the breaking capacity — the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole, 20A unit. Use 2-pole to switch both live and neutral on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — MCBs are installed inside a distribution board on live busbars and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eGenuine Hager MCBs clip directly onto standard 35mm DIN rail and are designed to work across the Hager DB range — check your board's existing MCB range\/series if you need an exact match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163349807203,"sku":"MW220","price":60.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MW220_1.webp?v=1786965573"},{"product_id":"hager-mw232-2-pole-32a-mcb-type-c-6ka","title":"Hager MW232 2-Pole 32A MCB Type C 6kA","description":"\u003ch2\u003eHager MW232 2-Pole 32A MCB Type C 6kA\u003c\/h2\u003e\u003cp\u003eThe Hager MW232 is a 2-pole 32A Type C MCB with 6kA breaking capacity for high-current double-pole circuit protection in UAE residential and commercial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2-pole 32A Type C MCB, 6kA\u003c\/li\u003e\n\u003cli\u003eDouble-pole protection for high-load circuits\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MW quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMW232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230\/400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-load double-pole circuit protection\u003c\/li\u003e\n\u003cli\u003eCooker, shower, and appliance circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial DB sub-main protection\u003c\/li\u003e\n\u003cli\u003eGeneral high-current circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Type C\" mean on this MCB?\u003c\/strong\u003e\u003cbr\u003eType C describes the tripping curve — it allows a higher inrush current (roughly 5–10 times the rated current) before tripping on short-circuit, which suits motors, transformers, and other inductive loads that draw a brief high current at switch-on without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA rating mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the breaking capacity — the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole, 32A unit. Use 2-pole to switch both live and neutral on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — MCBs are installed inside a distribution board on live busbars and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eGenuine Hager MCBs clip directly onto standard 35mm DIN rail and are designed to work across the Hager DB range — check your board's existing MCB range\/series if you need an exact match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163349839971,"sku":"MW232","price":60.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MW232.webp?v=1786965575"},{"product_id":"hager-mcn210-2-pole-10a-mcb-type-c-6ka","title":"Hager MCN210 2-Pole 10A MCB Type C 6kA","description":"\u003ch2\u003eHager MCN210 2-Pole 10A MCB Type C 6kA\u003c\/h2\u003e\u003cp\u003eThe Hager MCN210 is a 2-pole 10A Type C MCB with 6kA breaking capacity for double-pole lighting and circuit protection in UAE residential and commercial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2-pole 10A Type C MCB, 6kA\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MCN quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMCN210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230\/400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDouble-pole lighting and circuit protection\u003c\/li\u003e\n\u003cli\u003eResidential and commercial DB circuit protection\u003c\/li\u003e\n\u003cli\u003eConsumer unit and panel protection\u003c\/li\u003e\n\u003cli\u003eGeneral building services circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Type C\" mean on this MCB?\u003c\/strong\u003e\u003cbr\u003eType C describes the tripping curve — it allows a higher inrush current (roughly 5–10 times the rated current) before tripping on short-circuit, which suits motors, transformers, and other inductive loads that draw a brief high current at switch-on without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA rating mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the breaking capacity — the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole, 10A unit. Use 2-pole to switch both live and neutral on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — MCBs are installed inside a distribution board on live busbars and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eGenuine Hager MCBs clip directly onto standard 35mm DIN rail and are designed to work across the Hager DB range — check your board's existing MCB range\/series if you need an exact match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163349872739,"sku":"MCN210","price":60.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MCN210.webp?v=1786965577"},{"product_id":"hager-mcn232-2-pole-32a-mcb-type-c-6ka","title":"Hager MCN232 2-Pole 32A MCB Type C 6kA","description":"\u003ch2\u003eHager MCN232 2-Pole 32A MCB Type C 6kA\u003c\/h2\u003e\u003cp\u003eThe Hager MCN232 is a 2-pole 32A Type C MCB with 6kA breaking capacity for high-current double-pole circuit protection in UAE residential and commercial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2-pole 32A Type C MCB, 6kA\u003c\/li\u003e\n\u003cli\u003eHigh-current double-pole protection\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MCN quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMCN232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230\/400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-current double-pole circuit protection\u003c\/li\u003e\n\u003cli\u003eCooker and appliance circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial DB sub-main MCB protection\u003c\/li\u003e\n\u003cli\u003eGeneral high-current circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Type C\" mean on this MCB?\u003c\/strong\u003e\u003cbr\u003eType C describes the tripping curve — it allows a higher inrush current (roughly 5–10 times the rated current) before tripping on short-circuit, which suits motors, transformers, and other inductive loads that draw a brief high current at switch-on without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA rating mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the breaking capacity — the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole, 32A unit. Use 2-pole to switch both live and neutral on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — MCBs are installed inside a distribution board on live busbars and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eGenuine Hager MCBs clip directly onto standard 35mm DIN rail and are designed to work across the Hager DB range — check your board's existing MCB range\/series if you need an exact match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163349938275,"sku":"MCN232","price":60.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_71dc7150-bd5d-4b4b-bc94-5582955f39aa.webp?v=1786965577"},{"product_id":"hager-mw340-3-pole-40a-mcb-type-c-6ka","title":"Hager MW340 3-Pole 40A MCB Type C 6kA","description":"\u003ch2\u003eHager MW340 3-Pole 40A MCB Type C 6kA\u003c\/h2\u003e\u003cp\u003eThe Hager MW340 is a 3-pole 40A Type C MCB with 6kA breaking capacity for three-phase motor and power circuit protection in UAE commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pole 40A Type C MCB, 6kA for three-phase circuit protection\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MW quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMW340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThree-phase motor feeder circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial DB three-phase circuits\u003c\/li\u003e\n\u003cli\u003eHVAC and building services three-phase protection\u003c\/li\u003e\n\u003cli\u003eGeneral three-phase power circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Type C\" mean on this MCB?\u003c\/strong\u003e\u003cbr\u003eType C describes the tripping curve — it allows a higher inrush current (roughly 5–10 times the rated current) before tripping on short-circuit, which suits motors, transformers, and other inductive loads that draw a brief high current at switch-on without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA rating mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the breaking capacity — the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole, 40A unit. Use 3 or 4 poles for a three-phase circuit, with 4-pole also switching neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — MCBs are installed inside a distribution board on live busbars and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eGenuine Hager MCBs clip directly onto standard 35mm DIN rail and are designed to work across the Hager DB range — check your board's existing MCB range\/series if you need an exact match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163350364259,"sku":"MW340","price":60.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MW340.webp?v=1786965578"},{"product_id":"hager-mu325a-3-pole-25a-mcb-type-c-6ka","title":"Hager 3-Pole 25A MCB Type C 6kA MU325A","description":"\u003ch2\u003eHager MU325A 3-Pole 25A MCB Type C 6kA\u003c\/h2\u003e\u003cp\u003eThe Hager MU325A is a 3-pole 25A Type C MCB with 6kA breaking capacity for three-phase circuit protection in UAE commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pole 25A Type C MCB, 6kA\u003c\/li\u003e\n\u003cli\u003eThree-phase motor and power circuit protection\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MU quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMU325A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThree-phase motor feeder and power circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial distribution boards\u003c\/li\u003e\n\u003cli\u003eHVAC and building services three-phase circuits\u003c\/li\u003e\n\u003cli\u003eGeneral three-phase MCB protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Type C\" mean on this MCB?\u003c\/strong\u003e\u003cbr\u003eType C describes the tripping curve — it allows a higher inrush current (roughly 5–10 times the rated current) before tripping on short-circuit, which suits motors, transformers, and other inductive loads that draw a brief high current at switch-on without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA rating mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the breaking capacity — the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole, 25A unit. Use 3 or 4 poles for a three-phase circuit, with 4-pole also switching neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — MCBs are installed inside a distribution board on live busbars and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eGenuine Hager MCBs clip directly onto standard 35mm DIN rail and are designed to work across the Hager DB range — check your board's existing MCB range\/series if you need an exact match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163350397027,"sku":"MU325A","price":85.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MU325A_1.webp?v=1786965580"},{"product_id":"hager-mcn363-3-pole-63a-mcb-type-c-6ka","title":"Hager MCN363 3-Pole 63A MCB Type C 6kA","description":"\u003ch2\u003eHager MCN363 3-Pole 63A MCB Type C 6kA\u003c\/h2\u003e\u003cp\u003eThe Hager MCN363 is a 3-pole 63A Type C MCB with 6kA breaking capacity for high-current three-phase sub-main and incoming circuit protection in UAE commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pole 63A high-current MCB with 6kA breaking capacity\u003c\/li\u003e\n\u003cli\u003eThree-phase sub-main and incoming protection\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MCN quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMCN363\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThree-phase sub-main and incoming circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial distribution boards\u003c\/li\u003e\n\u003cli\u003eLarge HVAC and building services circuit protection\u003c\/li\u003e\n\u003cli\u003ePanel incoming and sub-main MCB\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Type C\" mean on this MCB?\u003c\/strong\u003e\u003cbr\u003eType C describes the tripping curve — it allows a higher inrush current (roughly 5–10 times the rated current) before tripping on short-circuit, which suits motors, transformers, and other inductive loads that draw a brief high current at switch-on without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA rating mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the breaking capacity — the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole, 63A unit. Use 3 or 4 poles for a three-phase circuit, with 4-pole also switching neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — MCBs are installed inside a distribution board on live busbars and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eGenuine Hager MCBs clip directly onto standard 35mm DIN rail and are designed to work across the Hager DB range — check your board's existing MCB range\/series if you need an exact match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163350429795,"sku":"MCN363","price":90.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MCN363.webp?v=1786965581"},{"product_id":"hager-mu463a-4-pole-63a-mcb-type-c-6ka","title":"Hager MU463A 4-Pole 63A MCB Type C 6kA","description":"\u003ch2\u003eHager MU463A 4-Pole 63A MCB Type C 6kA\u003c\/h2\u003e\u003cp\u003eThe Hager MU463A is a 4-pole 63A Type C MCB with 6kA breaking capacity for three-phase + neutral high-current incoming and sub-main circuit protection in UAE commercial and industrial distribution boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4-pole 63A MCB for three-phase + neutral circuit protection\u003c\/li\u003e\n\u003cli\u003eType C, 6kA breaking capacity\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MU quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMU463A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFour-pole three-phase + neutral incoming circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial DB sub-main MCB\u003c\/li\u003e\n\u003cli\u003eHVAC and building services distribution\u003c\/li\u003e\n\u003cli\u003ePanel incoming and sub-main four-pole protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does \"Type C\" mean on this MCB?\u003c\/strong\u003e\u003cbr\u003eType C describes the tripping curve — it allows a higher inrush current (roughly 5–10 times the rated current) before tripping on short-circuit, which suits motors, transformers, and other inductive loads that draw a brief high current at switch-on without nuisance tripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6kA rating mean?\u003c\/strong\u003e\u003cbr\u003e6kA is the breaking capacity — the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 4-pole, 63A unit. Use 3 or 4 poles for a three-phase circuit, with 4-pole also switching neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — MCBs are installed inside a distribution board on live busbars and must be fitted by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit my existing Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eGenuine Hager MCBs clip directly onto standard 35mm DIN rail and are designed to work across the Hager DB range — check your board's existing MCB range\/series if you need an exact match.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163350462563,"sku":"MU463A","price":185.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/MU463A.webp?v=1786965583"},{"product_id":"hager-ha100z-3-pole-100a-mccb","title":"Hager MCCB 3-Pole 100A HHA100Z","description":"\u003cdiv\u003e\n\u003ch2\u003eHager HHA100Z 3-Pole 100A MCCB\u003c\/h2\u003e\n\u003cp\u003eThe Hager HHA100Z is a 3-pole, 100A moulded case circuit breaker (MCCB) with a fixed thermal-magnetic trip unit, built for sub-main feeder and incoming circuit protection in UAE commercial and industrial distribution boards. It handles higher fault currents than a standard MCB, making it the right choice for main and sub-main protection on three-phase supplies.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3-pole, 100A rated current for three-phase incoming\/feeder protection\u003c\/li\u003e\n\u003cli\u003eFixed thermal-magnetic (TM F\/F) trip unit, fixed front DIN-rail mounting\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: Icu 25kA @ 400V AC \/ 35kA @ 240V AC (IEC 60947-2)\u003c\/li\u003e\n\u003cli\u003eService breaking capacity: Ics 25kA @ 230V AC \/ 20kA @ 400V AC\u003c\/li\u003e\n\u003cli\u003eRated operational voltage (Ue): 220–415V AC, 50–60Hz\u003c\/li\u003e\n\u003cli\u003eIP4X protection, compact frame (130 × 75 × 68mm)\u003c\/li\u003e\n\u003cli\u003eRated for 20,000 mechanical and 10,000 electrical operations\u003c\/li\u003e\n\u003cli\u003eGenuine Hager, Made in France, compliant with IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHHA100Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eMCCB (Moulded Case Circuit Breaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage (Ue)\u003c\/td\u003e\n\u003ctd\u003e220–415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e25 kA @ 400V AC \/ 35 kA @ 240V AC \/ 4 kA @ 690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Breaking Capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003e25 kA @ 230V AC \/ 20 kA @ 400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Unit\u003c\/td\u003e\n\u003ctd\u003eTM F\/F (thermal-magnetic, fixed settings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFixed, front-mounted, DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd\u003e4–95 mm² rigid \/ 4–70 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndurance\u003c\/td\u003e\n\u003ctd\u003e20,000 mechanical \/ 10,000 electrical operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree-phase sub-main feeder protection\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial DB incoming protection\u003c\/li\u003e\n\u003cli\u003eHigh-current circuit MCCB protection\u003c\/li\u003e\n\u003cli\u003eBuilding services main distribution protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an MCCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) like the HHA100Z is built for higher currents and fault levels — up to 25kA breaking capacity here — and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen do I need an MCCB instead of an MCB?\u003c\/strong\u003e\u003cbr\u003eUse an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board, rather than on individual final circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThe HHA100Z is a 3-pole device for three-phase circuits without a switched neutral, suited to three-phase feeders and main incomers on a 3-wire supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163350495331,"sku":"HA100Z","price":180.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/HHA100Z.webp?v=1786965636"},{"product_id":"hager-ha125z-3-pole-125a-mccb","title":"Hager MCCB 3-Pole 125A HHA125Z","description":"\u003ch2\u003eHager HA125Z 3-Pole 125A MCCB\u003c\/h2\u003e\n\u003cp\u003eThe Hager HA125Z is a 3-pole 125A MCCB for main incoming and sub-main feeder protection in UAE commercial and industrial distribution switchgear and distribution boards.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3-pole 125A MCCB for high-current incoming and feeder protection\u003c\/li\u003e\n\u003cli\u003eFixed front mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MCCB quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHHA125Z\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain incoming protection in commercial switchgear\u003c\/li\u003e\n\u003cli\u003eThree-phase sub-main feeder MCCB\u003c\/li\u003e\n\u003cli\u003eIndustrial panel incoming protection\u003c\/li\u003e\n\u003cli\u003eLarge building services main distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCCB and an MCB?\u003c\/strong\u003e\u003cbr\u003eMCCBs (moulded case circuit breakers) handle higher current ratings than standard MCBs and are typically used as main incomers or sub-main protection in distribution boards, rather than on individual final circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole, 125A unit, sized for a three-phase supply or sub-main.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — an MCCB of this rating is installed as part of a distribution board's main protection and must be fitted and commissioned by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere is this typically used?\u003c\/strong\u003e\u003cbr\u003eAs the main incomer or sub-main breaker in commercial, industrial, or larger residential distribution boards, protecting the downstream final-circuit MCBs and RCCBs.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163350528099,"sku":"HHA125Z","price":225.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/HHA125Z.webp?v=1786965639"},{"product_id":"hager-hha063z-3-pole-63a-mccb","title":"Hager MCCB 3-Pole 63A HHA063Z","description":"\u003ch2\u003eHager HHA063Z 3-Pole 63A MCCB\u003c\/h2\u003e\u003cp\u003eThe Hager HHA063Z is a 3-pole 63A MCCB for sub-main feeder and incoming circuit protection in UAE commercial and industrial distribution boards, providing reliable protection for higher-current three-phase circuits.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pole 63A MCCB for three-phase circuit protection\u003c\/li\u003e\n\u003cli\u003eFixed front mounting\u003c\/li\u003e\n\u003cli\u003eGenuine Hager MCCB quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHHA063Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThree-phase sub-main and incoming circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial DB MCCB protection\u003c\/li\u003e\n\u003cli\u003eMotor feeder and power circuit protection\u003c\/li\u003e\n\u003cli\u003eBuilding services main distribution protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCCB and an MCB?\u003c\/strong\u003e\u003cbr\u003eMCCBs (moulded case circuit breakers) handle higher current ratings than standard MCBs and are typically used as main incomers or sub-main protection in distribution boards, rather than on individual final circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 3-pole, 63A unit, sized for a three-phase supply or sub-main.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — an MCCB of this rating is installed as part of a distribution board's main protection and must be fitted and commissioned by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere is this typically used?\u003c\/strong\u003e\u003cbr\u003eAs the main incomer or sub-main breaker in commercial, industrial, or larger residential distribution boards, protecting the downstream final-circuit MCBs and RCCBs.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":44163350560867,"sku":"HHA063Z","price":190.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/HHA063Z.webp?v=1786965641"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/collections\/pngegg_2423a83b-b8b3-4663-aa62-7feb19709074.png?v=1771090181","url":"https:\/\/www.deluxeuae.com\/collections\/hager-switchgear-distribution-uae.oembed?page=2","provider":"Deluxe Electricals","version":"1.0","type":"link"}