{"title":"ELCBs","description":"\u003cp\u003eShop earth leakage circuit breakers — ELCBs, also sold as RCCBs — for villas, apartments and commercial boards across the UAE. ABB and Hager devices in 2-pole and 4-pole, 16A to 100A, with 10mA, 30mA, 100mA and 300mA sensitivities.\u003c\/p\u003e\u003ch2\u003eWhich mA sensitivity do I need?\u003c\/h2\u003e\u003cp\u003eThe mA figure is the leakage current at which the device trips, and it decides what is being protected. \u003cstrong\u003e30mA\u003c\/strong\u003e is the shock-protection figure — socket circuits, bathrooms, kitchens and outdoor supplies. \u003cstrong\u003e10mA\u003c\/strong\u003e is more sensitive again, for a single high-risk circuit. \u003cstrong\u003e100mA and 300mA\u003c\/strong\u003e are fire and equipment protection at distribution level, sitting upstream of the 30mA devices; they will not protect a person from electric shock. Fitting a 300mA unit where a 30mA is called for is the most common mistake we see on replacements.\u003c\/p\u003e\u003ch2\u003e2-pole or 4-pole?\u003c\/h2\u003e\u003cp\u003eCount the phases. \u003cstrong\u003e2-pole\u003c\/strong\u003e switches line and neutral on a single-phase 230V board. \u003cstrong\u003e4-pole\u003c\/strong\u003e switches three lines and neutral on a 400V three-phase board. The ampere rating — 25A, 40A, 63A or 100A — is the current the device can carry, not the level at which it protects, and an RCCB gives no overload protection on its own; that stays the job of the breaker beside it.\u003c\/p\u003e\u003ch2\u003eType AC or Type A?\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eType AC\u003c\/strong\u003e responds to conventional alternating leakage. \u003cstrong\u003eType A\u003c\/strong\u003e also detects pulsating DC leakage, which is what electronics, variable-speed drives and many modern appliances produce. Replacing like-for-like keeps an existing board consistent; changing sensitivity, type or pole count should be confirmed by a licensed electrician against the circuits involved.\u003c\/p\u003e","products":[{"product_id":"hager-rccb-40a-4p-30ma-cdc441j","title":"Hager CDC441J RCCB 40A 4-Pole 30mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CDC441J RCCB 40A 4-Pole 30mA Type AC — ELCB\u003c\/h2\u003e\n\u003cp\u003eThe Hager CDC441J is a 40A, 4-pole residual current circuit breaker (RCCB\/ELCB) with 30mA Type AC sensitivity, made in France for reliable earth-leakage protection in UAE residential, commercial, and light industrial distribution boards. Its 30mA rating is calibrated for personnel protection, tripping fast enough to prevent electric shock on final circuits.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated current: 40A, 4-pole (3P+N) configuration\u003c\/li\u003e\n\u003cli\u003e30mA Type AC sensitivity — personnel protection level\u003c\/li\u003e\n\u003cli\u003eRated voltage: 240–415V AC, 50Hz\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Idm): 1.50kA; conditional short-circuit current (Inc): 6kA per EN 61008-1\u003c\/li\u003e\n\u003cli\u003eIP20 protection rating, compact 4-module DIN rail width\u003c\/li\u003e\n\u003cli\u003eScrew terminals (top) and biconnect terminals (bottom); 1–25mm² rigid \/ 1–16mm² flexible conductor capacity\u003c\/li\u003e\n\u003cli\u003eRated for 4,000 mechanical and 2,000 electrical operating cycles\u003c\/li\u003e\n\u003cli\u003eMade in France by Hager, compliant with IEC\/EN safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCDC441J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P (3P+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity (Idn)\u003c\/td\u003e\n\u003ctd\u003e30 mA, Type AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage (Ue)\u003c\/td\u003e\n\u003ctd\u003e240–415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Idm)\u003c\/td\u003e\n\u003ctd\u003e1.50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConditional Short-Circuit Current (Inc)\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail, 4 modules (70 mm width)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd\u003e1–25 mm² rigid \/ 1–16 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndurance\u003c\/td\u003e\n\u003ctd\u003e4,000 mechanical \/ 2,000 electrical cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential villas and apartments\u003c\/li\u003e\n\u003cli\u003eCommercial offices, schools, hospitals, and retail outlets\u003c\/li\u003e\n\u003cli\u003eLight industrial distribution boards\u003c\/li\u003e\n\u003cli\u003eCircuits requiring 30mA high-sensitivity personnel protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects a circuit from overload and short-circuit current. An RCCB\/RCD like the CDC441J monitors for earth leakage current and trips to prevent electric shock — it does not provide overload protection. The two are typically installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e30mA is the personnel-protection threshold: the CDC441J trips if it detects 30mA or more of current leaking to earth, fast enough to prevent dangerous electric shock. This makes it suitable for final circuits such as socket outlets and bathrooms, unlike higher-mA (100\/300mA) devices, which are used mainly for fire and equipment protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThe CDC441J is a 4-pole (3P+N) device for three-phase supplies with neutral, protecting all three phases and the neutral conductor. Use a 2-pole RCCB for single-phase circuits instead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution-board component that must be installed and commissioned by a licensed electrician in accordance with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41549417840739,"sku":"CDC441J","price":126.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CDC441J.webp?v=1786954814"},{"product_id":"abb-elcb-rccb-63a-4-pole-30ma","title":"ABB RCCB 63 Amp 4-Pole 30mA Type AC — FH204 ELCB","description":"\u003cdiv\u003e\n\u003ch2\u003eABB FH204 AC-63\/0.03 — 63A, 4P RCCB, 30mA\u003c\/h2\u003e\n\u003cp\u003eABB FH204 AC-63\/0.03 is a four-pole RCCB (Residual Current Circuit Breaker) rated at 63A, with 30mA residual current sensitivity. Designed to reliably detect earth leakage and protect personnel and equipment across UAE installations. Ideal for distribution boards and panel mounting in residential, commercial, and industrial projects.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e63A rated current with 4-pole configuration\u003c\/li\u003e\n\u003cli\u003e30mA residual current sensitivity for enhanced safety\u003c\/li\u003e\n\u003cli\u003eAC-type protection for earth leakage faults\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting for quick and clean panel integration\u003c\/li\u003e\n\u003cli\u003eProven ABB reliability for UAE electrical installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse;\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFH204 AC-63\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Type\u003c\/td\u003e\n\u003ctd\u003eAC Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistribution boards and commercial electrical panels\u003c\/li\u003e\n\u003cli\u003eIndustrial installations requiring reliable earth leakage protection\u003c\/li\u003e\n\u003cli\u003eResidential main panels and safety-critical circuits where leakage faults pose risk\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects circuits and wiring against overload and short-circuit current. An RCCB like this one protects against earth leakage by monitoring current imbalance and disconnecting the circuit — the two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e30mA RCCBs are sized for personnel\/shock protection on final circuits — the standard choice for socket outlets and circuits people directly touch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this a 4-pole ELCB or RCCB?\u003c\/strong\u003e\u003cbr\u003eYes — RCCB and ELCB are two names for the same type of device. This model is a 4-pole unit rated 63A with 30mA sensitivity, switching all three phases plus neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes it mount on DIN rail?\u003c\/strong\u003e\u003cbr\u003eYes, it's designed for standard DIN rail mounting in distribution boards and panels alongside other DIN-rail devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCCBs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41549422100579,"sku":"FH204 AC-63\/0,03","price":160.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000172350_400x400_d867bf6e-40c5-48a4-b064-9f8dcee142e6.jpg?v=1787498107"},{"product_id":"abb-elcb-rccb-40a-4p-30ma-fh204","title":"ABB FH204 RCCB 40A 4-Pole 30mA Type AC — ELCB","description":"\u003cdiv\u003e\n\u003cp\u003eABB ELCB\/RCCB 40A, 4-pole, 30 mA residual-current device (FH204 AC-40\/0,03) provides reliable protection against electric shocks and equipment damage by continuously monitoring current and tripping on leakage. Designed for 400V systems, it suits UAE installations where safety and reliability are critical.\u003c\/p\u003e \u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eRated current: 40A\u003c\/li\u003e \u003cli\u003eNumber of poles: 4\u003c\/li\u003e \u003cli\u003eResidual current: 30 mA\u003c\/li\u003e \u003cli\u003eOperating characteristic: Instantaneous\u003c\/li\u003e \u003cli\u003eRated voltage: 400V\u003c\/li\u003e \u003cli\u003ePower loss: 3.2 W per pole (rated conditions)\u003c\/li\u003e \u003cli\u003eStandards: IEC 61008\u003c\/li\u003e \u003cli\u003eRoHS compliant\u003c\/li\u003e \u003cli\u003eDimensions: 70 × 85 × 69 mm; Weight: 0.360 kg\u003c\/li\u003e \u003cli\u003eModel: FH204 AC-40\/0,03\u003c\/li\u003e \u003cli\u003eEAN: 8012542895206\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFH204 AC-40\/0,03\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eRated current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eNumber of poles\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eResidual current\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eOperating characteristic\u003c\/td\u003e\n\u003ctd\u003eInstantaneous\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e400V\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e3.2 W per pole (rated conditions)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61008\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003ctd\u003eCompliant (EU 2011\/65\/EU)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDimensions (W×H×D)\u003c\/td\u003e\n\u003ctd\u003e70 × 85 × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.360 kg\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e1 unit per package; gross weight 0.403 kg\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e8012542895206\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eResidential distribution boards and home electrical protection\u003c\/li\u003e \u003cli\u003eCommercial spaces and offices needing reliable leakage protection\u003c\/li\u003e \u003cli\u003eIndustrial panels with 4-wire 400V systems requiring 30 mA discrimination\u003c\/li\u003e \u003cli\u003eEasy retrofit into ABB-compatible panels for UAE projects\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects circuits and wiring against overload and short-circuit current. An RCCB like this one protects against earth leakage by monitoring current imbalance and disconnecting the circuit — the two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e30mA RCCBs are sized for personnel\/shock protection on final circuits — the standard choice for socket outlets and circuits people directly touch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 4-pole (4P) RCCB switches all three phases plus neutral together. Use 4P for three-phase supplies or distribution boards where the neutral must also be isolated; 2-pole devices are used for single-phase circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be used alongside MCBs in the same board?\u003c\/strong\u003e\u003cbr\u003eYes. This RCCB is typically installed upstream of the MCBs it protects, on the same DIN rail, so a leakage fault trips the RCCB while overloads\/short circuits are still cleared by the individual MCBs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCCBs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797518852195,"sku":"FH204 AC-40\/0, 03","price":129.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-elcbs-default-title-abb-earth-leakage-circuit-breaker-40a-4-pole-30ma-elcb-rccb-fh204-ac-40-0-03-31538351407203.jpg?v=1787498173"},{"product_id":"abb-elcb-rccb-100a-4p-300ma-f204","title":"ABB F204 RCCB 100A 4-Pole 300mA Type AC — ELCB","description":"\u003cdiv\u003e\n\u003ch2\u003eABB ELCB\/RCCB 100A 4P 300mA F204\u003c\/h2\u003e\n\u003cp\u003eABB Earth Leakage Circuit Breaker (ELCB\/RCCB) 4-pole, 100 A, 300 mA residual current rating. Built for durability and reliable protection in UAE electrical installations.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFour-pole (4P) residual current circuit breaker (RCCB) for earth-leakage protection\u003c\/li\u003e\n\u003cli\u003eRated current: 100 A with 300 mA residual current sensitivity\u003c\/li\u003e\n\u003cli\u003eType AC sensitivity: detects sinusoidal AC residual fault currents\u003c\/li\u003e\n\u003cli\u003eConditional short-circuit rating: 10 kA\u003c\/li\u003e\n\u003cli\u003eComplies with IEC 61008\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting for standard distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e \u003cli\u003eBrand: ABB\u003c\/li\u003e \u003cli\u003eCurrent rating: 100 A\u003c\/li\u003e \u003cli\u003eType: ELCB\/RCCB, 4P\u003c\/li\u003e \u003cli\u003eResidual current rating: 300 mA\u003c\/li\u003e \u003cli\u003eModel: F204\u003c\/li\u003e \u003cli\u003eDurable construction for long service life\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eSpecification\u003c\/th\u003e \u003cth\u003eValue\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eABB\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eProduct type\u003c\/td\u003e \u003ctd\u003eELCB \/ RCCB\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCurrent rating\u003c\/td\u003e \u003ctd\u003e100 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePoles\u003c\/td\u003e \u003ctd\u003e4P\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eResidual current rating\u003c\/td\u003e \u003ctd\u003e300 mA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eModel\u003c\/td\u003e \u003ctd\u003eF204\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eProtection for distribution boards in commercial and residential UAE projects\u003c\/li\u003e \u003cli\u003eSuitable for 4-pole protection in main and sub-distribution panels\u003c\/li\u003e \u003cli\u003eIdeal for electrical rooms and control panels requiring reliable earth leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects circuits and wiring against overload and short-circuit current. An RCCB like this one protects against earth leakage by monitoring current imbalance and disconnecting the circuit — the two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 300mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e300mA RCCBs are sized for fire and equipment protection on larger circuits and sub-mains, not personal shock protection — that requires a 30mA device. A 300mA unit is a common choice as a main incomer or sub-distribution protection device upstream of 30mA final-circuit RCDs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 4-pole (4P) RCCB switches all three phases plus neutral together. Use 4P for three-phase supplies or distribution boards where the neutral must also be isolated; 2-pole devices are used for single-phase circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be used alongside MCBs in the same board?\u003c\/strong\u003e\u003cbr\u003eYes. This RCCB is typically installed upstream of the MCBs it protects, on the same DIN rail, so a leakage fault trips the RCCB while overloads\/short circuits are still cleared by the individual MCBs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCCBs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797519638627,"sku":"F204 100A\/0.30","price":363.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/IMAGE-EDIT_a27f5d89-5a78-44c2-b88c-7b6e212fbef0.png?v=1786954782"},{"product_id":"abb-elcb-rccb-25a-2p-30ma-fh202","title":"ABB FH202 RCCB 25A 2-Pole 30mA Type AC — ELCB","description":"\u003cdiv\u003e\n\u003cp\u003eABB ELCB\/RCCB FH202, 25A 2P 30mA, delivers reliable earth leakage protection for UAE electrical installations. The 2-pole device detects residual current and interrupts power to prevent electrical shocks and leakage faults in residential, commercial, and light-industrial panels. With DIN rail mounting and ABB durability, this unit is a dependable choice for UAE projects.\u003c\/p\u003e \u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eCurrent rating: 25 A\u003c\/li\u003e \u003cli\u003ePoles: 2P\u003c\/li\u003e \u003cli\u003eSensitivity: 30 mA\u003c\/li\u003e \u003cli\u003eType: ELCB\/RCCB (earth leakage protection)\u003c\/li\u003e \u003cli\u003eDIN rail mounting for quick, secure installation\u003c\/li\u003e \u003cli\u003eBrand: ABB – renowned reliability for UAE deployments\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eSpecification\u003c\/th\u003e \u003cth\u003eValue\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eProduct Type\u003c\/td\u003e \u003ctd\u003eStandard earth leakage circuit breaker (RCCB\/ELCB)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eABB\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eModel\u003c\/td\u003e \u003ctd\u003eFH202\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCurrent Rating\u003c\/td\u003e \u003ctd\u003e25 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePoles\u003c\/td\u003e \u003ctd\u003e2P\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSensitivity\u003c\/td\u003e \u003ctd\u003e30 mA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMounting\u003c\/td\u003e \u003ctd\u003eDIN Rail\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eApplications\u003c\/td\u003e \u003ctd\u003eResidential, Industrial, Commercial\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eIdeal for UAE residential mains, office fit-outs, and light-industrial power distributions where residual current protection is required. Protects occupants and equipment from leakage faults and electrical shocks in distribution boards and panel boards.\u003c\/p\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects circuits and wiring against overload and short-circuit current. An RCCB like this one protects against earth leakage by monitoring current imbalance and disconnecting the circuit — the two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e30mA RCCBs are sized for personnel\/shock protection on final circuits — the standard choice for socket outlets and circuits people directly touch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (2P) RCCB switches live and neutral on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be used alongside MCBs in the same board?\u003c\/strong\u003e\u003cbr\u003eYes. This RCCB is typically installed upstream of the MCBs it protects, on the same DIN rail, so a leakage fault trips the RCCB while overloads\/short circuits are still cleared by the individual MCBs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCCBs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797519704163,"sku":"FH202 25A\/0.03\/2P","price":184.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/abb-elcbs-default-title-abb-earth-leakage-circuit-breaker-elcb-rccb-25a-2p-30ma-fh202-25a-0-03-2p-2csf202006r1250-31538352455779.jpg?v=1787498178"},{"product_id":"abb-f202-100a-2p-100ma-rccb","title":"ABB F202 RCCB 100A 2-Pole 100mA Type A — ELCB","description":"\u003cdiv\u003e\n\u003ch2\u003eABB ELCB\/RCCB 100A 2P 100mA F202 A-100\/0.1\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2-pole RCCB for compact panel layouts\u003c\/li\u003e\n\u003cli\u003eCurrent rating: 100 A\u003c\/li\u003e\n\u003cli\u003eResidual current rating: 100 mA\u003c\/li\u003e\n\u003cli\u003eCharacteristic: F202\u003c\/li\u003e\n\u003cli\u003eEarth leakage protection to prevent electrical fires\u003c\/li\u003e\n\u003cli\u003eReliable ABB build quality, suitable for UAE installations\u003c\/li\u003e\n\u003cli\u003eDesigned for residential, commercial and light industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eELCB \/ RCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF202 A-100\/0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Rating\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharacteristic\u003c\/td\u003e\n\u003ctd\u003eF202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eEarth leakage protection; overcurrent safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplications\u003c\/td\u003e\n\u003ctd\u003eResidential, Commercial, Light Industrial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eDatasheets: Download PDF\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain distribution boards in homes and apartments\u003c\/li\u003e\n\u003cli\u003eSmall to medium commercial installations\u003c\/li\u003e\n\u003cli\u003eLight industrial panels and workshops\u003c\/li\u003e\n\u003cli\u003eRenewal projects where reliable earth leakage protection is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects circuits and wiring against overload and short-circuit current. An RCCB like this one protects against earth leakage by monitoring current imbalance and disconnecting the circuit — the two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e100mA RCCBs are sized for fire and equipment protection on larger circuits and sub-mains, not personal shock protection — that requires a 30mA device. A 100mA unit is a common choice as a main incomer or sub-distribution protection device upstream of 30mA final-circuit RCDs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (2P) RCCB switches live and neutral on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be used alongside MCBs in the same board?\u003c\/strong\u003e\u003cbr\u003eYes. This RCCB is typically installed upstream of the MCBs it protects, on the same DIN rail, so a leakage fault trips the RCCB while overloads\/short circuits are still cleared by the individual MCBs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCCBs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797519802467,"sku":"F202-100A","price":199.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000330800_master.png?v=1787499458"},{"product_id":"abb-f204-100a-4p-30ma-rccb","title":"ABB F204 RCCB 100A 4-Pole 30mA Type A — ELCB","description":"\u003cdiv\u003e\n\u003cp\u003eABB ELCB\/RCCB 100A 4P 30mA F204 is a four-pole residual current device designed for robust leakage protection in UAE installations. With 100 A rated current and 30 mA sensitivity, it helps prevent electrical fires and electric shock in residential, commercial, and industrial panels.\u003c\/p\u003e \u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eCurrent Rating: 100 A\u003c\/li\u003e \u003cli\u003eNumber of Poles: 4\u003c\/li\u003e \u003cli\u003eSensitivity: 30 mA\u003c\/li\u003e \u003cli\u003eTechnical Characteristic: F204\u003c\/li\u003e \u003cli\u003eProduct Type: Standard Earth Leakage Circuit Breaker (ELCB\/RCCB)\u003c\/li\u003e \u003cli\u003eBrand: ABB\u003c\/li\u003e \u003cli\u003eApplications: Residential, commercial and industrial installations\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eCurrent rating\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eNumber of poles\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eTechnical characteristic\u003c\/td\u003e\n\u003ctd\u003eF204\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eStandard Earth Leakage Circuit Breaker (ELCB\/RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eModel\/Code\u003c\/td\u003e\n\u003ctd\u003eF204 100A\/0.03\/4P\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eResidential electrical panels in UAE homes and apartments\u003c\/li\u003e \u003cli\u003eCommercial distribution boards for offices and retail spaces\u003c\/li\u003e \u003cli\u003eLight industrial equipment protection in workshops and factories\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects circuits and wiring against overload and short-circuit current. An RCCB like this one protects against earth leakage by monitoring current imbalance and disconnecting the circuit — the two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e30mA RCCBs are sized for personnel\/shock protection on final circuits — the standard choice for socket outlets and circuits people directly touch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 4-pole (4P) RCCB switches all three phases plus neutral together. Use 4P for three-phase supplies or distribution boards where the neutral must also be isolated; 2-pole devices are used for single-phase circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be used alongside MCBs in the same board?\u003c\/strong\u003e\u003cbr\u003eYes. This RCCB is typically installed upstream of the MCBs it protects, on the same DIN rail, so a leakage fault trips the RCCB while overloads\/short circuits are still cleared by the individual MCBs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCCBs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41797520654435,"sku":"F204 100A\/0.03\/","price":355.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000082910-400x400.png?v=1786954785"},{"product_id":"hager-63a-4p-rccb-300ma-cfc464j","title":"Hager CFC464J RCCB 63A 4-Pole 300mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CFC464J RCCB 63A 4-Pole 300mA Type AC — ELCB\u003c\/h2\u003e\n\u003cp\u003eThe Hager CFC464J is a 63A, 4-pole residual current circuit breaker (RCCB\/ELCB) with 300mA Type AC sensitivity, made in France for earth-leakage protection on medium-to-large residential, commercial, and light industrial installations in the UAE. Its 300mA rating is calibrated for fire and equipment protection on distribution circuits rather than individual socket outlets.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated current: 63A, 4-pole (3P+N) configuration\u003c\/li\u003e\n\u003cli\u003e300mA Type AC sensitivity — fire\/equipment protection level\u003c\/li\u003e\n\u003cli\u003eRated voltage: 240–415V AC, 50Hz\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Idm): 1.50kA; conditional short-circuit current (Inc): 6kA per EN 61008-1\u003c\/li\u003e\n\u003cli\u003eIP20 protection rating, compact 4-module DIN rail width\u003c\/li\u003e\n\u003cli\u003eScrew terminals (top) and biconnect terminals (bottom); 1–25mm² rigid \/ 1–16mm² flexible conductor capacity\u003c\/li\u003e\n\u003cli\u003eRated for 4,000 mechanical and 2,000 electrical operating cycles\u003c\/li\u003e\n\u003cli\u003eMade in France by Hager, compliant with IEC\/EN safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCFC464J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e63 A (derates to 45 A at 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P (3P+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity (Idn)\u003c\/td\u003e\n\u003ctd\u003e300 mA, Type AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage (Ue)\u003c\/td\u003e\n\u003ctd\u003e240–415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Idm)\u003c\/td\u003e\n\u003ctd\u003e1.50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConditional Short-Circuit Current (Inc)\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e4,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting \/ Dimensions\u003c\/td\u003e\n\u003ctd\u003eDIN rail, 4 modules — 83 × 70 × 70 mm (H×W×D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd\u003e1–25 mm² rigid \/ 1–16 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +70°C (derated above 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndurance\u003c\/td\u003e\n\u003ctd\u003e4,000 mechanical \/ 2,000 electrical cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential villas and housing projects\u003c\/li\u003e\n\u003cli\u003eCommercial offices, schools, hospitals, and retail spaces\u003c\/li\u003e\n\u003cli\u003eIndustrial distribution panels\u003c\/li\u003e\n\u003cli\u003eInstallations requiring 63A, 4-pole, 300mA leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects a circuit from overload and short-circuit current. An RCCB\/RCD like the CFC464J monitors for earth leakage current and trips to prevent fire and equipment damage — it does not provide overload protection. The two are typically installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 300mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e300mA is a fire\/equipment-protection threshold rather than a personnel-protection one: the CFC464J trips on larger leakage currents, making it suited to main incomers and distribution circuits where nuisance tripping from cumulative leakage must be avoided, while 30mA devices are used on individual final circuits for shock protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThe CFC464J is a 4-pole (3P+N) device for three-phase supplies with neutral, protecting all three phases and the neutral conductor. Use a 2-pole RCCB for single-phase circuits instead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution-board component that must be installed and commissioned by a licensed electrician in accordance with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797539856483,"sku":"CFC464J","price":166.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CFC464J.webp?v=1786954809"},{"product_id":"hager-rccb-40a-2p-300ma","title":"Hager CFC241J RCCB 40A 2-Pole 300mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003cp\u003eHager 40A 2P 300mA RCCB (CFC241J) delivers reliable earth-leakage protection for UAE residential and commercial electrical installations. This compact device detects ground faults and isolates circuits to prevent electric shocks and fire risks, ensuring safety for homes, offices, and construction sites.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: CFC241J\u003c\/li\u003e\n\u003cli\u003eRated Current: 40 A\u003c\/li\u003e\n\u003cli\u003ePoles: 2P\u003c\/li\u003e\n\u003cli\u003eSensitivity: 300 mA\u003c\/li\u003e\n\u003cli\u003eType: RCCB (ELCB) with earth leakage protection\u003c\/li\u003e\n\u003cli\u003eCompact design for easy installation\u003c\/li\u003e\n\u003cli\u003eIEC standards compliant\u003c\/li\u003e\n\u003cli\u003eSuitable for panel boards and consumer units in UAE projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCFC241J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eRCCB (ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth Leakage Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel \/ Consumer Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eResidential distribution boards and consumer units\u003c\/li\u003e\n\u003cli\u003eCommercial electrical panels and service boards\u003c\/li\u003e\n\u003cli\u003eAreas requiring reliable ground fault protection\u003c\/li\u003e\n\u003cli\u003eProjects prioritizing quick, safe isolation of leakage currents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an RCCB and an MCB?\u003c\/strong\u003e\u003cbr\u003eAn RCCB (ELCB) detects earth leakage current and disconnects the circuit to protect against electric shock — it does not protect against overload or short-circuit current. It's normally installed alongside MCBs, which handle overload and short-circuit protection; the two work together, not as substitutes for each other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 300mA rating mean, and do I need this sensitivity?\u003c\/strong\u003e\u003cbr\u003e300mA sensitivity is typically used for fire protection on distribution or fixed-appliance circuits, rather than direct personal shock protection — check your circuit's requirement before ordering. If you're unsure which sensitivity your board needs, an electrician can confirm from the circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole unit, suited to a single-phase circuit (with neutral switched). Match the pole count to your incoming supply and the circuit(s) you're protecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — an RCCB is installed inside a distribution board and connected to live busbars. This must be done by a licensed electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797540577379,"sku":"CFC241J","price":106.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CFC241J.webp?v=1786954789"},{"product_id":"hager-rccb-63a-4p-30ma","title":"Hager CDC464J RCCB 63A 4-Pole 30mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager RCCB (ELCB) 63A 4P 30mA – CDC464J\u003c\/h2\u003e\n\u003cp\u003eThe CDC464J is a four-pole RCCB (ELCB) with 63A rating and 30mA sensitivity, delivering fast earth-leakage protection for people and equipment in UAE installations. Reliable, compact, and panel-friendly for residential, commercial, and light industrial applications.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eBrand: Hager\u003c\/li\u003e \u003cli\u003eModel: CDC464J\u003c\/li\u003e \u003cli\u003eRated Current: 63A\u003c\/li\u003e \u003cli\u003ePoles: 4P\u003c\/li\u003e \u003cli\u003eSensitivity: 30mA\u003c\/li\u003e \u003cli\u003eDevice Type: RCCB \/ ELCB\u003c\/li\u003e \u003cli\u003eFast leakage tripping\u003c\/li\u003e \u003cli\u003eCompact, panel-mount design\u003c\/li\u003e \u003cli\u003eIEC safety standards compliant\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCDC464J\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC safety standards compliant\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eResidential villas and apartment complexes\u003c\/li\u003e \u003cli\u003eOffices, schools, hospitals, and retail spaces\u003c\/li\u003e \u003cli\u003eLight industrial distribution panels\u003c\/li\u003e \u003cli\u003eElectrical systems requiring 30mA high-sensitivity protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an RCCB and an MCB?\u003c\/strong\u003e\u003cbr\u003eAn RCCB (ELCB) detects earth leakage current and disconnects the circuit to protect against electric shock — it does not protect against overload or short-circuit current. It's normally installed alongside MCBs, which handle overload and short-circuit protection; the two work together, not as substitutes for each other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30mA rating mean, and do I need this sensitivity?\u003c\/strong\u003e\u003cbr\u003e30mA is the sensitivity required for personal shock protection on socket outlet and bathroom circuits per most wiring regulations. If you're unsure which sensitivity your board needs, an electrician can confirm from the circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 4-pole unit, suited to a three-phase circuit. Match the pole count to your incoming supply and the circuit(s) you're protecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — an RCCB is installed inside a distribution board and connected to live busbars. This must be done by a licensed electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797540741219,"sku":"Cdc464J","price":251.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CDC464J.webp?v=1786954806"},{"product_id":"hager-rccb-40a-2p-100ma","title":"Hager CEC241J RCCB 40A 2-Pole 100mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager RCCB (ELCB) 40A 2P 100mA – CEC241J\u003c\/h2\u003e\n\u003cp\u003eReliable earth-leakage protection for residential, commercial, and light industrial panels. The CEC241J delivers fast leakage tripping, compact installation, and IEC-compliant performance for UAE projects.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eBrand: Hager\u003c\/li\u003e \u003cli\u003eModel: CEC241J\u003c\/li\u003e \u003cli\u003eRated Current: 40A\u003c\/li\u003e \u003cli\u003ePoles: 2P (Double Pole)\u003c\/li\u003e \u003cli\u003eSensitivity: 100mA\u003c\/li\u003e \u003cli\u003eDevice Type: RCCB \/ ELCB\u003c\/li\u003e \u003cli\u003eFast tripping on leakage faults\u003c\/li\u003e \u003cli\u003eIEC standards compliant\u003c\/li\u003e \u003cli\u003eCompact design for easy panel installation\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eSpecification\u003c\/th\u003e \u003cth\u003eDetails\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eBrand\u003c\/td\u003e \u003ctd\u003eHager\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eModel\u003c\/td\u003e \u003ctd\u003eCEC241J\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRated Current\u003c\/td\u003e \u003ctd\u003e40A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePoles\u003c\/td\u003e \u003ctd\u003e2P (Double Pole)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSensitivity\u003c\/td\u003e \u003ctd\u003e100mA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDevice Type\u003c\/td\u003e \u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStandards\u003c\/td\u003e \u003ctd\u003eIEC compliant\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip characteristics\u003c\/td\u003e \u003ctd\u003eFast tripping on leakage faults\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eResidential apartments, villas, and homes\u003c\/li\u003e \u003cli\u003eOffices, schools, and retail spaces\u003c\/li\u003e \u003cli\u003eLight industrial power systems\u003c\/li\u003e \u003cli\u003ePanels requiring 100mA medium-sensitivity leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an RCCB and an MCB?\u003c\/strong\u003e\u003cbr\u003eAn RCCB (ELCB) detects earth leakage current and disconnects the circuit to protect against electric shock — it does not protect against overload or short-circuit current. It's normally installed alongside MCBs, which handle overload and short-circuit protection; the two work together, not as substitutes for each other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA rating mean, and do I need this sensitivity?\u003c\/strong\u003e\u003cbr\u003e100mA sensitivity is typically used for fire protection on distribution or fixed-appliance circuits, rather than direct personal shock protection — check your circuit's requirement before ordering. If you're unsure which sensitivity your board needs, an electrician can confirm from the circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole unit, suited to a single-phase circuit (with neutral switched). Match the pole count to your incoming supply and the circuit(s) you're protecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — an RCCB is installed inside a distribution board and connected to live busbars. This must be done by a licensed electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797540937827,"sku":"CEC241J","price":107.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CEC241J.webp?v=1786954804"},{"product_id":"hager-rccb-100a-4p-100ma","title":"Hager CE485Z RCCB 100A 4-Pole 100mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CE485Z RCCB 100A 4-Pole 100mA Type AC\u003c\/h2\u003e\n\u003cp\u003eThe Hager CE485Z is a 100A, 4-pole residual current circuit breaker (RCCB\/ELCB) with 100mA sensitivity, built to protect large residential, commercial, and industrial installations from earth leakage faults. Type AC sensing detects standard sinusoidal residual currents, disconnecting the circuit to reduce the risk of fire and equipment damage. Made in France, the CE485Z carries Hager's full European build and design standard for demanding distribution boards.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e100A rated current, 4-pole (4P) — switches all phases plus neutral\u003c\/li\u003e\n\u003cli\u003e100mA tripping sensitivity — sized for fire\/equipment protection on larger circuits, not personnel protection\u003c\/li\u003e\n\u003cli\u003eType AC residual current sensing for standard sinusoidal leakage currents\u003c\/li\u003e\n\u003cli\u003e1.5kA breaking capacity; 6kA rated conditional short-circuit current (per EN 61008-1)\u003c\/li\u003e\n\u003cli\u003eCompact 4-module DIN rail mounting, IP20 enclosure\u003c\/li\u003e\n\u003cli\u003eRated for 2000 electrical \/ 4000 mechanical operations\u003c\/li\u003e\n\u003cli\u003eScrew terminal connections\u003c\/li\u003e\n\u003cli\u003eComplies with IEC 61008-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCE485Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB (Residual Current Circuit Breaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Residual Operating Current (IΔn)\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P (Four Pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e1.5 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current\u003c\/td\u003e\n\u003ctd\u003e6 kA (per EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Width\u003c\/td\u003e\n\u003ctd\u003e4 modules (DIN rail)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Endurance\u003c\/td\u003e\n\u003ctd\u003e2000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Endurance\u003c\/td\u003e\n\u003ctd\u003e4000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial distribution boards and switchgear\u003c\/li\u003e\n\u003cli\u003eCommercial facilities: offices, malls, schools, hospitals\u003c\/li\u003e\n\u003cli\u003eLarge residential complexes and villas\u003c\/li\u003e\n\u003cli\u003eProjects requiring 100A 4-Pole protection at 100mA sensitivity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects circuits and wiring against overload and short-circuit current. An RCCB like the CE485Z protects against earth leakage by monitoring current imbalance and disconnecting the circuit — the two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e100mA RCCBs are sized for fire and equipment protection on larger circuits and sub-mains, not personal shock protection — that requires a 30mA device. A 100mA unit is a common choice as a main incomer or sub-distribution protection device upstream of 30mA final-circuit RCDs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need — why 4-pole?\u003c\/strong\u003e\u003cbr\u003eA 4-pole (4P) RCCB switches all three phases plus the neutral together. Use 4P for three-phase supplies or distribution boards where the neutral must also be isolated; 2-pole devices are used for single-phase circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be used alongside MCBs in the same board?\u003c\/strong\u003e\u003cbr\u003eYes. The CE485Z is typically installed upstream of the MCBs it protects, on the same Hager DIN rail, so a leakage fault trips the RCCB while overloads\/short circuits are still cleared by the individual MCBs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCCBs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797541134435,"sku":"CE485Z","price":405.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CE485Z.webp?v=1786954803"},{"product_id":"hager-rccb-100a-2p-100ma","title":"Hager CE285Z RCCB 100A 2-Pole 100mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CE285Z RCCB 100A 2-Pole 100mA Type AC\u003c\/h2\u003e\n\u003cp\u003eThe Hager CE285Z is a 100A, 2-pole residual current circuit breaker (RCCB\/ELCB) with 100mA sensitivity, designed to protect single-phase residential, commercial, and light industrial circuits from earth leakage faults. Type AC sensing detects standard sinusoidal residual currents, disconnecting the circuit to reduce shock, fire, and equipment-damage risk. Made in France, it carries Hager's full European design and manufacturing standard.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e100A rated current, 2-pole (2P) — switches line and neutral\u003c\/li\u003e\n\u003cli\u003e100mA tripping sensitivity — sized for fire\/equipment protection, not personnel protection\u003c\/li\u003e\n\u003cli\u003eType AC residual current sensing for standard sinusoidal leakage currents\u003c\/li\u003e\n\u003cli\u003e1.5kA breaking capacity; 6kA rated conditional short-circuit current (per EN 61008-1)\u003c\/li\u003e\n\u003cli\u003eCompact 2-module DIN rail mounting (35mm wide), IP20 enclosure\u003c\/li\u003e\n\u003cli\u003eRated for 2000 electrical \/ 4000 mechanical operations\u003c\/li\u003e\n\u003cli\u003eScrew terminal connections\u003c\/li\u003e\n\u003cli\u003eComplies with IEC 61008-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCE285Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB (Residual Current Circuit Breaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Residual Operating Current (IΔn)\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P (Double Pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e1.5 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current\u003c\/td\u003e\n\u003ctd\u003e6 kA (per EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Width\u003c\/td\u003e\n\u003ctd\u003e2 modules, 35 mm (DIN rail)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Endurance\u003c\/td\u003e\n\u003ctd\u003e2000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Endurance\u003c\/td\u003e\n\u003ctd\u003e4000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential villas and apartment complexes\u003c\/li\u003e\n\u003cli\u003eCommercial spaces: offices, schools, retail stores, hospitals\u003c\/li\u003e\n\u003cli\u003eIndustrial distribution boards and small control systems\u003c\/li\u003e\n\u003cli\u003eProjects requiring 100A 2-Pole medium-sensitivity protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects circuits and wiring against overload and short-circuit current. An RCCB like the CE285Z protects against earth leakage by monitoring current imbalance and disconnecting the circuit — the two are complementary and normally installed together.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e100mA RCCBs are sized for fire and equipment protection, not personal shock protection — that requires a 30mA device. A 100mA unit is a common choice as a main incomer or sub-distribution device upstream of 30mA final-circuit RCDs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need — what does 2-pole mean for this circuit?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (2P) RCCB switches the line and neutral conductors of a single-phase circuit. Use 2P for single-phase supplies and circuits; 4-pole devices are used where all three phases plus neutral need isolating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCCBs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be paired with MCBs on the same board?\u003c\/strong\u003e\u003cbr\u003eYes. The CE285Z is typically installed upstream of the MCBs it protects on the same Hager DIN rail, so an earth leakage fault trips the RCCB while overloads\/short circuits are cleared by the individual MCBs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797541265507,"sku":"CE285Z","price":200.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CE285Z.webp?v=1786954801"},{"product_id":"hager-rccb-40a-4p-300ma","title":"Hager CFC441J RCCB 40A 4-Pole 300mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CFC441J RCCB 40A 4-Pole 300mA Type AC (ELCB)\u003c\/h2\u003e\n\u003cp\u003eThe Hager CFC441J is a 4-pole residual current circuit breaker (RCCB\/ELCB) rated 40 A with 300 mA sensitivity, built for earth-leakage protection on larger residential, commercial, and light industrial distribution boards. Manufactured in France, it disconnects the circuit quickly on detecting a leakage fault, protecting connected equipment and reducing fire risk from earth faults. Type AC sensing suits standard AC installations.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4-pole (3P+N) RCCB for 3-phase, 4-wire distribution circuits\u003c\/li\u003e\n\u003cli\u003eRated current: 40 A\u003c\/li\u003e\n\u003cli\u003eSensitivity (rated residual operating current): 300 mA, Type AC\u003c\/li\u003e\n\u003cli\u003eRated conditional short-circuit current (Inc): 6 kA per EN 61008-1\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Idm): 1.5 kA\u003c\/li\u003e\n\u003cli\u003eCompact 4-module DIN rail enclosure (70 mm wide)\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage 500 V, impulse withstand 4,000 V\u003c\/li\u003e\n\u003cli\u003eComplies with IEC\/EN 61008-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCFC441J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P (3P+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Residual Operating Current (Idn)\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e240\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Idm)\u003c\/td\u003e\n\u003ctd\u003e1.5 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current (Inc)\u003c\/td\u003e\n\u003ctd\u003e6 kA (per EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e4,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail, 4 modules (70 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e83 x 70 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd\u003e1–25 mm² solid \/ 1–16 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eMade in France\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential apartment blocks and villas with 3-phase supply\u003c\/li\u003e\n\u003cli\u003eCommercial buildings — offices, schools, hospitals, retail\u003c\/li\u003e\n\u003cli\u003eIndustrial distribution boards and sub-panels\u003c\/li\u003e\n\u003cli\u003eCircuits requiring 300 mA fire\/equipment-protection level sensitivity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects against overload and short-circuit currents. An RCCB (residual current circuit breaker), also called an ELCB, monitors the balance of current between line and neutral conductors and disconnects the circuit when it detects earth leakage — protecting against electric shock and fire from insulation faults. The two devices protect against different fault types and are typically installed together on a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 300 mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e300 mA is a higher-threshold sensitivity generally used for fire and equipment protection on larger distribution circuits, rather than direct personnel protection (which typically uses 30 mA devices). It trips on the larger leakage currents typical of insulation faults or equipment failure, reducing fire risk on sub-mains and distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does 4-pole mean and do I need it for this circuit?\u003c\/strong\u003e\u003cbr\u003eA 4-pole (3P+N) RCCB switches all three phase conductors and the neutral together. It's used on 3-phase, 4-wire circuits — typically main incomers or distribution boards feeding 3-phase loads — so both phase and neutral are isolated together on a leakage trip.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component that must be installed and connected by a licensed electrician in accordance with local wiring regulations. Incorrect installation of an RCCB can leave circuits without leakage protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit a standard Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eYes. The CFC441J is part of Hager's modular DIN-rail range and installs alongside Hager MCBs, isolators, and other DB accessories in a standard Hager consumer unit or distribution board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797541691491,"sku":"CF441J","price":122.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CFC441J.webp?v=1786954801"},{"product_id":"hager-rccb-63a-4p-100ma","title":"Hager CEC464J RCCB 63A 4-Pole 100mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CEC464J RCCB 63A 4-Pole 100mA Type AC (ELCB)\u003c\/h2\u003e\n\u003cp\u003eThe Hager CEC464J is a 4-pole residual current circuit breaker (RCCB\/ELCB) rated 63 A with 100 mA sensitivity, designed for earth-leakage protection on higher-current residential, commercial, and industrial distribution boards. Manufactured in France, it monitors line and neutral current continuously and disconnects the circuit rapidly on detecting an earth fault, reducing the risk of electrical fire and equipment damage from insulation faults. Type AC sensing suits standard AC installations.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 63 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 4 (3P+N)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current:\u003c\/strong\u003e 100 mA, Type AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Conditional Short-Circuit Current (Inc):\u003c\/strong\u003e 6 kA per IEC 61008-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (Idm):\u003c\/strong\u003e 1,500 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC 61008-1, RoHS compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Hager, Made in France\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCEC464J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Residual Operating Current (Idn)\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e240\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Idm)\u003c\/td\u003e\n\u003ctd\u003e1,500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current (Inc)\u003c\/td\u003e\n\u003ctd\u003e6 kA (per EN\/IEC 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e4,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail, 4 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e83 x 70 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eMade in France\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential buildings and villas with higher-current 3-phase supply\u003c\/li\u003e\n\u003cli\u003eCommercial buildings — offices, schools, hospitals, retail\u003c\/li\u003e\n\u003cli\u003eIndustrial distribution boards and main incomers up to 63 A\u003c\/li\u003e\n\u003cli\u003eCircuits requiring 100 mA fire\/equipment-protection level sensitivity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects against overload and short-circuit currents. An RCCB (residual current circuit breaker), also called an ELCB, monitors the balance of current between line and neutral conductors and disconnects the circuit when it detects earth leakage — protecting against electric shock and fire from insulation faults. The two devices protect against different fault types and are typically installed together on a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100 mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e100 mA sits between 30 mA personnel-protection devices and 300 mA fire-protection devices. It is commonly used for equipment and fire protection on distribution circuits where a very low trip threshold isn't required, tripping on the larger leakage currents typical of insulation faults or equipment failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does 4-pole mean and do I need it for this circuit?\u003c\/strong\u003e\u003cbr\u003eA 4-pole RCCB switches all three phase conductors and the neutral together. It's used on 3-phase, 4-wire circuits — typically main incomers or distribution boards feeding 3-phase loads — so both phase and neutral are isolated together on a leakage trip.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component that must be installed and connected by a licensed electrician in accordance with local wiring regulations. Incorrect installation of an RCCB can leave circuits without leakage protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit a standard Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eYes. The CEC464J is part of Hager's modular DIN-rail range and installs alongside Hager MCBs, isolators, and other DB accessories in a standard Hager consumer unit or distribution board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797541888099,"sku":"CEC464J","price":192.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/hager-elcbs-default-title-hager-earth-leakage-circuit-breaker-63a-4pole-100ma-elcb-rccb-cec464j-31538396135523.jpg?v=1787498198"},{"product_id":"hager-onekonekt-25a-2p-100ma-rccb","title":"Hager CEC226J Onekonekt RCCB 25A 2-Pole 100mA Type AC — ELCB","description":"\u003cdiv\u003e\n\u003cp\u003eHager Onekonekt RCCB (ELCB) 25A 2P 100mA – CEC226J\u003c\/p\u003e \u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Hager CEC226J RCCB provides reliable earth-leakage protection with a 25A rating and 100mA sensitivity. It rapidly disconnects circuits on leakage, helping protect people and equipment in residential, commercial, and light industrial UAE installations.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eBrand: Hager – Onekonekt Series\u003c\/li\u003e \u003cli\u003eModel: CEC226J\u003c\/li\u003e \u003cli\u003eRated Current: 25A\u003c\/li\u003e \u003cli\u003ePoles: 2P (Double Pole)\u003c\/li\u003e \u003cli\u003eSensitivity: 100mA\u003c\/li\u003e \u003cli\u003eDevice Type: RCCB \/ ELCB\u003c\/li\u003e \u003cli\u003eRobust, compact design for easy panel installation\u003c\/li\u003e \u003cli\u003eFully compliant with IEC safety standards\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager – Onekonekt Series\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCEC226J\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P (Double Pole)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100mA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC safety standards compliant\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eResidential homes, villas, and apartments\u003c\/li\u003e \u003cli\u003eOffices, schools, and healthcare facilities\u003c\/li\u003e \u003cli\u003eCommercial buildings and retail outlets\u003c\/li\u003e \u003cli\u003eLight industrial power systems requiring reliable leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an RCCB and an MCB?\u003c\/strong\u003e\u003cbr\u003eAn RCCB (ELCB) detects earth leakage current and disconnects the circuit to protect against electric shock — it does not protect against overload or short-circuit current. It's normally installed alongside MCBs, which handle overload and short-circuit protection; the two work together, not as substitutes for each other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA rating mean, and do I need this sensitivity?\u003c\/strong\u003e\u003cbr\u003e100mA sensitivity is typically used for fire protection on distribution or fixed-appliance circuits, rather than direct personal shock protection — check your circuit's requirement before ordering. If you're unsure which sensitivity your board needs, an electrician can confirm from the circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole unit, suited to a single-phase circuit (with neutral switched). Match the pole count to your incoming supply and the circuit(s) you're protecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — an RCCB is installed inside a distribution board and connected to live busbars. This must be done by a licensed electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797542281315,"sku":"CEC226J","price":164.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CEC226J.webp?v=1786954799"},{"product_id":"hager-rccb-63a-2p-30ma","title":"Hager CDC264J RCCB 63A 2-Pole 30mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CDC264J RCCB 63A 2-Pole 30mA Type AC (ELCB)\u003c\/h2\u003e\n\u003cp\u003eThe Hager CDC264J RCCB (ELCB) delivers rapid disconnection at earth leakage currents, enhancing protection for people and equipment. Rated 63 A with a 30 mA sensitivity, it provides personnel-protection level earth-leakage protection for single-phase circuits. Manufactured in France and engineered to IEC standards, it offers reliable, fast fault isolation in UAE electrical installations, with a compact, durable design that fits neatly into distribution boards.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: Hager, Made in France\u003c\/li\u003e\n\u003cli\u003eModel: CDC264J\u003c\/li\u003e\n\u003cli\u003eRated Current: 63 A\u003c\/li\u003e\n\u003cli\u003ePoles: 2P (1P+N, Double Pole)\u003c\/li\u003e\n\u003cli\u003eSensitivity: 30 mA, Type AC — personnel protection level\u003c\/li\u003e\n\u003cli\u003eRated conditional short-circuit current (Inc): 6 kA per EN 61008-1\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Idm): 1.5 kA\u003c\/li\u003e\n\u003cli\u003eCompact, 2-module DIN rail enclosure (35 mm wide)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCDC264J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P (1P+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Residual Operating Current (Idn)\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e240 V AC (max. 415 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Idm)\u003c\/td\u003e\n\u003ctd\u003e1.5 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current (Inc)\u003c\/td\u003e\n\u003ctd\u003e6 kA (per EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e4,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail, 2 modules (35 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e83 x 35 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd\u003e1–25 mm² solid \/ 1–16 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eMade in France\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential homes and villas — single-phase final circuits\u003c\/li\u003e\n\u003cli\u003eCommercial buildings: offices, schools, healthcare facilities\u003c\/li\u003e\n\u003cli\u003eLight industrial distribution systems\u003c\/li\u003e\n\u003cli\u003eCircuits requiring 30 mA personnel-protection level sensitivity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (miniature circuit breaker) protects against overload and short-circuit currents. An RCCB (residual current circuit breaker), also called an ELCB, monitors the balance of current between line and neutral conductors and disconnects the circuit when it detects earth leakage — protecting against electric shock and fire from insulation faults. The two devices protect against different fault types and are typically installed together on a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30 mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e30 mA is the internationally recognised threshold for personnel protection — sensitive enough to disconnect the circuit before a leakage current through a person's body becomes dangerous. It's the standard sensitivity for socket outlets and other circuits directly accessible to people.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does 2-pole mean and do I need it for this circuit?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (1P+N) RCCB switches the line and neutral conductors together. It's used on single-phase circuits, so both conductors are isolated together the moment a leakage fault is detected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution board component that must be installed and connected by a licensed electrician in accordance with local wiring regulations. Incorrect installation of an RCCB can leave circuits without leakage protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this fit a standard Hager distribution board?\u003c\/strong\u003e\u003cbr\u003eYes. The CDC264J is part of Hager's modular DIN-rail range and installs alongside Hager MCBs, isolators, and other DB accessories in a standard Hager consumer unit or distribution board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797544083555,"sku":"CDC264J","price":212.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CDC264J_cd1a618f-efd6-49a1-8608-93917dc6971a.webp?v=1786954798"},{"product_id":"hager-rccb-40a-2p-30ma","title":"Hager CDC241J RCCB 40A 2-Pole 30mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003cp\u003eThe Hager CDC241J RCCB (ELCB) 40A, 2P, 30mA delivers reliable earth-leakage protection for people and equipment. With a fast-acting trip and 30mA sensitivity, it suits UAE residential, commercial, and light industrial installations.\u003c\/p\u003e \u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e2-pole RCCB\/ELCB, 40A rated current\u003c\/li\u003e \u003cli\u003e30 mA earth-leakage sensitivity for enhanced personal safety\u003c\/li\u003e \u003cli\u003eFast-acting trip mechanism for rapid disconnection\u003c\/li\u003e \u003cli\u003eCompact, durable design for modular electrical panels\u003c\/li\u003e \u003cli\u003eIEC-compliant protection suitable for UAE electrical projects\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCDC241J\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003cp\u003eDatasheets: Download PDF\u003c\/p\u003e \u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eResidential properties: apartments, villas\u003c\/li\u003e \u003cli\u003eCommercial spaces: offices, schools, retail stores\u003c\/li\u003e \u003cli\u003eLight industrial power distribution panels\u003c\/li\u003e \u003cli\u003eElectrical panels requiring 30 mA protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an RCCB and an MCB?\u003c\/strong\u003e\u003cbr\u003eAn RCCB (ELCB) detects earth leakage current and disconnects the circuit to protect against electric shock — it does not protect against overload or short-circuit current. It's normally installed alongside MCBs, which handle overload and short-circuit protection; the two work together, not as substitutes for each other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30mA rating mean, and do I need this sensitivity?\u003c\/strong\u003e\u003cbr\u003e30mA is the sensitivity required for personal shock protection on socket outlet and bathroom circuits per most wiring regulations. If you're unsure which sensitivity your board needs, an electrician can confirm from the circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole unit, suited to a single-phase circuit (with neutral switched). Match the pole count to your incoming supply and the circuit(s) you're protecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — an RCCB is installed inside a distribution board and connected to live busbars. This must be done by a licensed electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797544116323,"sku":"CDC241J","price":153.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CDC241J.webp?v=1786954879"},{"product_id":"hager-rccb-40a-4p-100ma","title":"Hager CEC441J RCCB 40A 4-Pole 100mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CEC441J RCCB 40A 4-Pole 100mA Type AC – ELCB, Made in France\u003c\/h2\u003e\n\u003cp\u003eThe Hager CEC441J is a 4-pole residual current circuit breaker (RCCB\/ELCB) rated 40A with 100mA Type AC sensitivity, built for earth-leakage protection on UAE distribution boards in residential, commercial and light-industrial installations. Manufactured in France to IEC 61008-1, it combines fast leakage tripping with long-term mechanical reliability in standard DIN-rail enclosures.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated current 40A across 4 poles (4P), suited to three-phase-plus-neutral distribution circuits\u003c\/li\u003e\n\u003cli\u003eRated residual operating current (sensitivity): 100mA, Type AC — for equipment and fire protection on sub-main\/distribution circuits\u003c\/li\u003e\n\u003cli\u003eRated operational voltage 240\/415V AC, 50Hz\u003c\/li\u003e\n\u003cli\u003eRated conditional short-circuit current (Inc) 6kA to EN\/IEC 61008-1; breaking and opening capacity 1500A\u003c\/li\u003e\n\u003cli\u003eCompact DIN-rail mounting, 4 modules wide (70 x 83 x 70mm), screw terminals\u003c\/li\u003e\n\u003cli\u003eIP20 protection rating; rated insulation voltage 500V, impulse withstand 4000V\u003c\/li\u003e\n\u003cli\u003eMechanical endurance 4000 operations, electrical endurance 2000 cycles\u003c\/li\u003e\n\u003cli\u003eRated operating temperature -25°C to 40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCEC441J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100mA, Type AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e240\/415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking\/Opening Capacity\u003c\/td\u003e\n\u003ctd\u003e1500A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current (Inc)\u003c\/td\u003e\n\u003ctd\u003e6kA (EN\/IEC 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting \/ Width\u003c\/td\u003e\n\u003ctd\u003eDIN rail, 4 modules (70mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e70 x 83 x 70mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical \/ Electrical Endurance\u003c\/td\u003e\n\u003ctd\u003e4000 operations \/ 2000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential buildings and villas\u003c\/li\u003e\n\u003cli\u003eCommercial projects: offices, shops, schools, hospitals\u003c\/li\u003e\n\u003cli\u003eLight industrial power distribution systems\u003c\/li\u003e\n\u003cli\u003eInstallations requiring medium-sensitivity earth leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/ELCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB (Miniature Circuit Breaker) protects against overload and short-circuit faults. An RCCB\/ELCB like the CEC441J monitors earth leakage current and trips on imbalance, protecting against electric shock and earth faults that an MCB cannot detect. They serve different protection functions and are often installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003eThe CEC441J trips when it detects a 100mA (0.1A) imbalance between live and neutral conductors. 100mA sensitivity is set for equipment and fire protection on distribution\/sub-main circuits, rather than the 30mA rating used for direct personnel shock protection on final circuits — it is typically paired with 30mA RCCBs\/RCBOs further downstream for full protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need — what does 4-pole (4P) mean for this circuit?\u003c\/strong\u003e\u003cbr\u003e4-pole means the device switches all four conductors of a three-phase-plus-neutral supply (3P+N). Use a 4-pole RCCB on three-phase distribution boards or where the neutral must also be isolated; single-phase circuits typically use a 2-pole (2P) device instead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. The CEC441J is a distribution board component and must be installed and commissioned by a licensed electrician in accordance with UAE wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the short-circuit\/breaking capacity of the CEC441J?\u003c\/strong\u003e\u003cbr\u003eIt has a rated conditional short-circuit current (Inc) of 6kA and a breaking\/opening capacity of 1500A, in line with IEC\/EN 61008-1 requirements — sufficient for typical residential and light-commercial distribution boards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797544149091,"sku":"Cec441J","price":166.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CEC441J.webp?v=1786954796"},{"product_id":"hager-rccb-63a-2p-100ma","title":"Hager CEC264J RCCB 63A 2-Pole 100mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager RCCB (ELCB) 63A 2P 100mA – CEC264J\u003c\/h2\u003e\n\u003cp\u003eThe Hager CEC264J RCCB delivers dependable earth leakage protection for residential, commercial, and light industrial installations. Designed with European precision, it safely disconnects on leakage faults to protect people and equipment.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e63 A rating with 2P (double pole) configuration\u003c\/li\u003e \u003cli\u003eSensitivity: 100 mA for reliable leakage detection\u003c\/li\u003e \u003cli\u003eRCCB \/ ELCB device type with fast tripping response\u003c\/li\u003e \u003cli\u003eCompact design for seamless panel integration\u003c\/li\u003e \u003cli\u003eIEC-standard compliant for UAE installations\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCEC264J\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P (Double Pole)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eTripping\u003c\/td\u003e\n\u003ctd\u003eFast, reliable leakage protection\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eIEC standards\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eCompact panel integration\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eResidential apartments, villas, and housing projects\u003c\/li\u003e \u003cli\u003eCommercial spaces: offices, schools, retail outlets\u003c\/li\u003e \u003cli\u003eLight industrial power distribution\u003c\/li\u003e \u003cli\u003eElectrical systems requiring medium-sensitivity leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an RCCB and an MCB?\u003c\/strong\u003e\u003cbr\u003eAn RCCB (ELCB) detects earth leakage current and disconnects the circuit to protect against electric shock — it does not protect against overload or short-circuit current. It's normally installed alongside MCBs, which handle overload and short-circuit protection; the two work together, not as substitutes for each other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA rating mean, and do I need this sensitivity?\u003c\/strong\u003e\u003cbr\u003e100mA sensitivity is typically used for fire protection on distribution or fixed-appliance circuits, rather than direct personal shock protection — check your circuit's requirement before ordering. If you're unsure which sensitivity your board needs, an electrician can confirm from the circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole unit, suited to a single-phase circuit (with neutral switched). Match the pole count to your incoming supply and the circuit(s) you're protecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — an RCCB is installed inside a distribution board and connected to live busbars. This must be done by a licensed electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797544280163,"sku":"CEC264J","price":167.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CEC264J.png?v=1786954787"},{"product_id":"hager-rccb-100a-4p-300ma","title":"Hager CF485Z RCCB 100A 4-Pole 300mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CF485Z RCCB 100A 4-Pole 300mA Type AC – ELCB, Made in France\u003c\/h2\u003e\n\u003cp\u003eThe Hager CF485Z is a high-capacity 4-pole residual current circuit breaker (RCCB\/ELCB) rated 100A with 300mA Type AC sensitivity, built for earth-leakage protection on heavy-duty distribution boards in residential, commercial and industrial installations across the UAE. Manufactured in France to EN 61008-1, it combines fast leakage tripping with a long service life in standard DIN-rail switchboards.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated current 100A across 4 poles (4P), suited to three-phase-plus-neutral distribution circuits\u003c\/li\u003e\n\u003cli\u003eRated residual operating current (sensitivity): 300mA, Type AC — for fire and equipment protection on incoming supply\/sub-main circuits\u003c\/li\u003e\n\u003cli\u003eRated conditional short-circuit current (Inc) 6kA to EN 61008-1; breaking and opening capacity 1.5kA\u003c\/li\u003e\n\u003cli\u003eCompact DIN-rail mounting, 4 modules wide (70 x 86 x 70mm), screw terminals\u003c\/li\u003e\n\u003cli\u003eIP20 protection rating; rated frequency 50Hz\u003c\/li\u003e\n\u003cli\u003eLow power loss: 30.2W total at rated current (11.9W per pole)\u003c\/li\u003e\n\u003cli\u003eMechanical endurance 4000 operations, electrical endurance 2000 cycles\u003c\/li\u003e\n\u003cli\u003eRated operating temperature -25°C to 40°C, derated at higher ambient temperatures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCF485Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e300mA, Type AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking\/Opening Capacity\u003c\/td\u003e\n\u003ctd\u003e1.5kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current (Inc)\u003c\/td\u003e\n\u003ctd\u003e6kA (EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstand Non-Tripping Surge\u003c\/td\u003e\n\u003ctd\u003e0.25kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e30.2W total \/ 11.9W per pole at rated current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting \/ Width\u003c\/td\u003e\n\u003ctd\u003eDIN rail, 4 modules (70mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e70 x 86 x 70mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical \/ Electrical Endurance\u003c\/td\u003e\n\u003ctd\u003e4000 operations \/ 2000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to 40°C (derated to 59A at 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Altitude \/ Pollution Degree\u003c\/td\u003e\n\u003ctd\u003e2000m \/ Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eEN 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial distribution panels and switchgear\u003c\/li\u003e\n\u003cli\u003eCommercial buildings: malls, offices, hospitals, schools\u003c\/li\u003e\n\u003cli\u003eLarge residential complexes and villas\u003c\/li\u003e\n\u003cli\u003eProjects requiring high-capacity, heavy-duty leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/ELCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects against overload and short-circuit faults. An RCCB\/ELCB like the CF485Z monitors earth leakage current and trips on imbalance, protecting against electric shock and earth faults an MCB cannot detect. The two are complementary and commonly installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 300mA sensitivity rating mean — will it protect against electric shock?\u003c\/strong\u003e\u003cbr\u003eThe CF485Z trips at a 300mA earth-leakage imbalance. This is a fire\/equipment-protection sensitivity — typically used as main incoming or sub-main protection on larger boards — rather than the 30mA rating required for direct personnel shock protection on final circuits, which should use separate 30mA RCCBs\/RCBOs downstream.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need — what does 4-pole (4P) mean for this circuit?\u003c\/strong\u003e\u003cbr\u003e4-pole means the device switches all four conductors of a three-phase-plus-neutral supply. Use a 4-pole RCCB on three-phase boards or where neutral isolation is required; single-phase circuits typically use a 2-pole device instead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. The CF485Z is a distribution board\/panel component rated up to 100A and must be installed and commissioned by a licensed electrician in accordance with UAE wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat size board or application is the 100A CF485Z suited for?\u003c\/strong\u003e\u003cbr\u003eIts 100A rating and 6kA short-circuit rating make it suitable for main incoming protection on larger residential complexes, commercial buildings and light-industrial distribution boards where high-capacity earth-leakage protection is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797544837219,"sku":"CF485Z","price":353.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CF485Z.webp?v=1786954880"},{"product_id":"hager-63a-2p-300ma-elcb-rccb","title":"Hager CFC264J RCCB 63A 2-Pole 300mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager 63A 2P 300mA ELCB\/RCCB CFC264J\u003c\/h2\u003e\n\u003cp\u003eEnsure reliable earth leakage protection in UAE installations with the Hager CFC264J ELCB\/RCCB. This 2-pole device delivers robust fault protection with a 300 mA residual current rating, safeguarding electrical systems against earth faults.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCurrent rating: 63 A\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n\u003cli\u003eRated residual operating current: 300 mA\u003c\/li\u003e\n\u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n\u003cli\u003eCompliance: IEC 61008-1\u003c\/li\u003e\n\u003cli\u003eBrand: Hager\u003c\/li\u003e\n\u003cli\u003eType: Standard Circuit Breaker\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCFC264J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent rating\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated residual current\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eIEC 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential distribution boards requiring earth leakage protection\u003c\/li\u003e\n\u003cli\u003eCommercial facilities needing robust RCCB protection for critical circuits\u003c\/li\u003e\n\u003cli\u003eSafety-conscious installations where leakage protection reduces shock risk\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an RCCB and an MCB?\u003c\/strong\u003e\u003cbr\u003eAn RCCB (ELCB) detects earth leakage current and disconnects the circuit to protect against electric shock — it does not protect against overload or short-circuit current. It's normally installed alongside MCBs, which handle overload and short-circuit protection; the two work together, not as substitutes for each other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 300mA rating mean, and do I need this sensitivity?\u003c\/strong\u003e\u003cbr\u003e300mA sensitivity is typically used for fire protection on distribution or fixed-appliance circuits, rather than direct personal shock protection — check your circuit's requirement before ordering. If you're unsure which sensitivity your board needs, an electrician can confirm from the circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole unit, suited to a single-phase circuit (with neutral switched). Match the pole count to your incoming supply and the circuit(s) you're protecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — an RCCB is installed inside a distribution board and connected to live busbars. This must be done by a licensed electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797545328739,"sku":"CFC264J","price":129.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CFC264J.webp?v=1786954880"},{"product_id":"hager-onekonekt-rccb-25a-4p-100ma","title":"Hager CEC426J Onekonekt RCCB 25A 4-Pole 100mA Type AC — ELCB","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CEC426J Onekonekt RCCB 25A 4-Pole 100mA Type AC – ELCB\u003c\/h2\u003e\n\u003cp\u003eThe Hager CEC426J is a 25A, 4-pole residual current circuit breaker (RCCB\/ELCB) with 100mA Type AC sensitivity from Hager's Onekonekt range, built for earth-leakage protection on UAE distribution boards in residential and light-commercial installations. Its bottom terminal is a bi-connect design that accepts either cables or Hager's Onekonekt busbar system, letting electricians wire panels faster while still working exactly like a standard screw terminal when a busbar isn't used.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated current 25A across 4 poles (3P+N), for three-phase-plus-neutral distribution circuits\u003c\/li\u003e\n\u003cli\u003eRated residual operating current (sensitivity): 100mA, Type AC — for equipment protection on distribution circuits\u003c\/li\u003e\n\u003cli\u003eRated operational voltage 240\/415V AC, 50Hz\u003c\/li\u003e\n\u003cli\u003eOnekonekt bi-connect bottom terminal accepts either cables or a Hager busbar, with a screw top terminal\u003c\/li\u003e\n\u003cli\u003eRated conditional short-circuit current (Inc) 6kA to EN 61008-1; breaking capacity 1.5kA\u003c\/li\u003e\n\u003cli\u003eWide conductor range: 1–25mm² solid \/ 1–16mm² flexible, tightening torque 2.8Nm\u003c\/li\u003e\n\u003cli\u003eCompact DIN-rail mounting, 4 modules wide (70 x 83 x 70mm); IP20 protection\u003c\/li\u003e\n\u003cli\u003eMechanical endurance 4000 operations, electrical endurance 2000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries \/ Model\u003c\/td\u003e\n\u003ctd\u003eOnekonekt CEC426J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P (3P+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100mA, Type AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e240\/415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity (Idm)\u003c\/td\u003e\n\u003ctd\u003e1.5kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current (Inc)\u003c\/td\u003e\n\u003ctd\u003e6kA (EN 61008-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew top \/ Onekonekt bi-connect bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Range\u003c\/td\u003e\n\u003ctd\u003e1–25mm² solid, 1–16mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting \/ Width\u003c\/td\u003e\n\u003ctd\u003eDIN rail, 4 modules (70mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e70 x 83 x 70mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical \/ Electrical Endurance\u003c\/td\u003e\n\u003ctd\u003e4000 operations \/ 2000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to 60°C rated (derated to 18A at 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN 61008-1 \/ IEC safety standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential homes and villas\u003c\/li\u003e\n\u003cli\u003eCommercial spaces: offices, schools, healthcare facilities\u003c\/li\u003e\n\u003cli\u003eIndustrial power distribution systems\u003c\/li\u003e\n\u003cli\u003eProjects requiring medium-sensitivity earth leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/ELCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects against overload and short-circuit faults. An RCCB\/ELCB like the CEC426J monitors earth leakage current and trips on imbalance, protecting against electric shock and earth faults an MCB cannot detect. The two are complementary and commonly fitted together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003eThe CEC426J trips at a 100mA earth-leakage imbalance, a sensitivity set for equipment and fire protection on distribution circuits rather than the 30mA rating used for direct personnel shock protection on final circuits — pair it with 30mA RCCBs\/RCBOs downstream where personnel protection is required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need — what does 4-pole (3P+N) mean for this circuit?\u003c\/strong\u003e\u003cbr\u003e4-pole (3 phase + neutral) means the device switches all four conductors of a three-phase supply, including the neutral. Use it on three-phase distribution boards; single-phase circuits typically use a 2-pole device instead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. The CEC426J is a distribution board component and must be installed and commissioned by a licensed electrician in accordance with UAE wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is Onekonekt, and can I still wire this with standard cables?\u003c\/strong\u003e\u003cbr\u003eOnekonekt is Hager's bi-connect terminal and busbar system for modular protection devices. The CEC426J's bottom terminal accepts either standard cables in the terminal cage or a Hager Onekonekt busbar — busbars simply speed up panel wiring on multi-way boards, and standard cable connection works exactly as normal when a busbar isn't used.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797545394275,"sku":"CEC426J","price":171.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CEC426J.webp?v=1786954796"},{"product_id":"hager-rccb-100a-2p-300ma","title":"Hager CF285Z RCCB 100A 2-Pole 300mA Type AC — ELCB Made in France","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CF285Z RCCB 100A 2-Pole 300mA Type AC — ELCB\u003c\/h2\u003e\n\u003cp\u003eThe Hager RCCB (ELCB) 100A 2-Pole 300mA – CF285Z delivers reliable protection against earth leakage faults, safeguarding both people and electrical installations. Made in France and built to IEC 61008-1, this high-current residual current device is designed for demanding residential, commercial, and industrial distribution boards where fire and equipment protection at the incomer or sub-main level is required.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: \u003cstrong\u003eHager\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel: \u003cstrong\u003eCF285Z\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRated Current: \u003cstrong\u003e100A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePoles: \u003cstrong\u003e2P (Double Pole)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSensitivity: \u003cstrong\u003e300mA, Type AC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDevice Type: RCCB \/ ELCB (Earth Leakage Circuit Breaker)\u003c\/li\u003e\n\u003cli\u003eFast tripping response to leakage currents\u003c\/li\u003e\n\u003cli\u003eRobust construction for demanding, high-current applications\u003c\/li\u003e\n\u003cli\u003eComplies with IEC 61008-1 for global safety assurance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCF285Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Residual Operating Current (IΔn)\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Type\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking\/Opening Capacity\u003c\/td\u003e\n\u003ctd\u003e1500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current (Inc, per EN 61008-1)\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Withstand (8\/20 µs wave, non-tripping)\u003c\/td\u003e\n\u003ctd\u003e0.25 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e14.3 W total (7.6 W per pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e83 x 35 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Width\u003c\/td\u003e\n\u003ctd\u003e2 modules (DIN 43880 size 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail, type O (symmetrical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Index\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\/Transport Temperature\u003c\/td\u003e\n\u003ctd\u003e-55°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e2 (IEC 60664 \/ IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Endurance\u003c\/td\u003e\n\u003ctd\u003e4000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Endurance\u003c\/td\u003e\n\u003ctd\u003e2000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential apartment blocks and villas\u003c\/li\u003e\n\u003cli\u003eCommercial facilities: offices, shops, schools\u003c\/li\u003e\n\u003cli\u003eIndustrial power distribution systems\u003c\/li\u003e\n\u003cli\u003eAny high-current circuit requiring earth leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (Miniature Circuit Breaker) protects a circuit against overload and short-circuit faults. An RCCB (Residual Current Circuit Breaker), also known as an ELCB, continuously monitors for earth leakage current and disconnects the supply if current is escaping to earth – protecting against electric shock and fire in a way an MCB cannot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 300mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e300mA is a higher-sensitivity threshold aimed at fire and equipment protection rather than personal shock protection (which typically needs 30mA). The CF285Z is best used as a main incomer or sub-main device protecting large distribution circuits, with 30mA RCCBs\/RCBOs used further downstream on final circuits for personnel protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need for this circuit?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole (2P) device, switching both line and neutral. It is intended for single-phase distribution boards and incomers; three-phase boards require a 4-pole equivalent.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution-board-mounted device and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the CF285Z suitable as a main switch\/incomer for a large board?\u003c\/strong\u003e\u003cbr\u003eYes – at 100A with 300mA sensitivity and a 6kA rated conditional short-circuit current, it is designed for high-load main or sub-main incomer protection on residential, commercial, and industrial boards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797545427043,"sku":"CF285Z","price":255.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CF285Z.webp?v=1786954793"},{"product_id":"hager-rccb-100a-4p-30ma","title":"Hager CD485Z RCCB 100A 4-Pole 30mA Type AC — ELCB Made in France","description":"\u003cdiv\u003eThe Hager RCCB (ELCB) CD485Z delivers robust earth-leakage protection for high-load electrical systems. With a 100A rating and 4 poles, it safeguards people and equipment from dangerous earth faults in residential, commercial, and industrial installations across the UAE. \u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e4P design for comprehensive line and neutral protection\u003c\/li\u003e \u003cli\u003e30 mA residual current sensitivity for enhanced personal safety\u003c\/li\u003e \u003cli\u003eFast disconnection on earth leakage faults to minimize risk\u003c\/li\u003e \u003cli\u003e100A rated current, ideal for heavy-duty applications\u003c\/li\u003e \u003cli\u003eEuropean build quality for demanding environments\u003c\/li\u003e \u003cli\u003eIEC standards-compliant protection\u003c\/li\u003e \u003cli\u003eSuitable for industrial control panels, distribution boards, and large-scale installations\u003c\/li\u003e \u003cli\u003eAvailable with fast UAE-wide delivery from Deluxe Electricals\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003eElectrical characteristics\u003c\/h3\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCD485Z\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRCCB \/ ELCB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC compliant\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eIndustrial control panels and distribution boards\u003c\/li\u003e \u003cli\u003eCommercial buildings such as malls, offices, and schools\u003c\/li\u003e \u003cli\u003eLarge residential complexes with high electrical load\u003c\/li\u003e \u003cli\u003eAny high-load installation requiring reliable earth leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an RCCB and an MCB?\u003c\/strong\u003e\u003cbr\u003eAn RCCB (ELCB) detects earth leakage current and disconnects the circuit to protect against electric shock — it does not protect against overload or short-circuit current. It's normally installed alongside MCBs, which handle overload and short-circuit protection; the two work together, not as substitutes for each other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30mA rating mean, and do I need this sensitivity?\u003c\/strong\u003e\u003cbr\u003e30mA is the sensitivity required for personal shock protection on socket outlet and bathroom circuits per most wiring regulations. If you're unsure which sensitivity your board needs, an electrician can confirm from the circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eThis is a 4-pole unit, suited to a three-phase circuit. Match the pole count to your incoming supply and the circuit(s) you're protecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo — an RCCB is installed inside a distribution board and connected to live busbars. This must be done by a licensed electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797546082403,"sku":"CD485Z","price":391.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CD485Z.webp?v=1786954793"},{"product_id":"hager-onekonekt-rccb-25a-2p-30ma","title":"Hager CDC226J Onekonekt RCCB 25A 2-Pole 30mA Type AC — ELCB","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CDC226J Onekonekt RCCB 25A 2-Pole 30mA Type AC — ELCB\u003c\/h2\u003e\n\u003cp\u003eThe Hager Onekonekt RCCB (ELCB) 25A 2-Pole 30mA – CDC226J offers reliable protection against earth leakage currents, safeguarding both people and electrical systems. Part of Hager's Onekonekt modular protection range and engineered to European quality standards, this breaker ensures fast, reliable disconnection to prevent electric shocks and fire hazards on residential and light commercial final circuits.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: \u003cstrong\u003eHager – Onekonekt Series\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel: \u003cstrong\u003eCDC226J\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRated Current: \u003cstrong\u003e25A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePoles: \u003cstrong\u003e2P (Double Pole)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSensitivity: \u003cstrong\u003e30mA, Type AC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDevice Type: Residual Current Circuit Breaker (RCCB \/ ELCB)\u003c\/li\u003e\n\u003cli\u003eEnsures personal safety by cutting power during leakage faults\u003c\/li\u003e\n\u003cli\u003eCompact design for easy installation in panels and consumer units\u003c\/li\u003e\n\u003cli\u003eBuilt to IEC standards for global compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCDC226J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eOnekonekt – Hager's unified modular protection range, compatible with Hager single\/three-phase busbars\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e2P (1P+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Residual Operating Current (IΔn)\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Type\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e4,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e1.5 kA (1500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e83 x 35 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Width\u003c\/td\u003e\n\u003ctd\u003e2 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminal (BIconnect bottom connection, busbar-compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Capacity\u003c\/td\u003e\n\u003ctd\u003e1–25 mm² solid \/ 1–16 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Index\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e2.32 W at rated current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Endurance\u003c\/td\u003e\n\u003ctd\u003e4000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Endurance\u003c\/td\u003e\n\u003ctd\u003e2000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Derating\u003c\/td\u003e\n\u003ctd\u003eRated 25 A up to 65°C ambient; derates to 21 A at 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential properties (apartments, villas)\u003c\/li\u003e\n\u003cli\u003eOffices, shops, and commercial spaces\u003c\/li\u003e\n\u003cli\u003eSchools, healthcare facilities, and public buildings\u003c\/li\u003e\n\u003cli\u003eLight industrial panels and projects requiring high safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (Miniature Circuit Breaker) protects a circuit against overload and short-circuit faults. An RCCB (Residual Current Circuit Breaker), also known as an ELCB, continuously monitors for earth leakage current and disconnects the supply if current is escaping to earth – protecting against electric shock and fire in a way an MCB cannot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 30mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e30mA is the internationally recognised threshold for personnel protection against electric shock, making the CDC226J suitable for final circuits – sockets, lighting, and general power – where there is direct risk of human contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need for this circuit?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole (2P, 1P+N) device switching both line and neutral, suited to single-phase circuits. Three-phase circuits require a 4-pole equivalent.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution-board-mounted device and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is Onekonekt?\u003c\/strong\u003e\u003cbr\u003eOnekonekt is Hager's unified range of modular protection devices – MCBs, RCCBs, RCBOs, and main switches – designed to fit a common single- or three-phase busbar system with BIconnect terminals, so devices can be wired from cables or fed directly from the busbar, speeding up panel-building and reducing wiring errors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797546147939,"sku":"CDC226J","price":122.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CDC226J.webp?v=1786954791"},{"product_id":"hager-onekonekt-rccb-16a-2p-10ma","title":"Hager CCC217J Onekonekt RCCB 16A 2-Pole 10mA Type AC — ELCB","description":"\u003cdiv\u003e\n\u003ch2\u003eHager CCC217J Onekonekt RCCB 16A 2-Pole 10mA Type AC — ELCB\u003c\/h2\u003e\n\u003cp\u003eThe Hager Onekonekt RCCB (ELCB) 16A 2-Pole 10mA – CCC217J provides advanced, high-sensitivity earth-leakage protection for residential, commercial, and light industrial applications. Designed to disconnect the circuit the instant leakage current is detected, this RCCB is built for locations where an extra margin of shock protection is needed, beyond the standard 30mA threshold.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: \u003cstrong\u003eHager – Onekonekt Series\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel: \u003cstrong\u003eCCC217J\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRated Current: \u003cstrong\u003e16A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePoles: \u003cstrong\u003e2P (Double Pole)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSensitivity: \u003cstrong\u003e10mA, Type AC (high-sensitivity)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eFunction: Residual Current Circuit Breaker (RCCB \/ ELCB)\u003c\/li\u003e\n\u003cli\u003eFast and reliable disconnection on earth-leakage faults\u003c\/li\u003e\n\u003cli\u003eCompact design for easy panel integration\u003c\/li\u003e\n\u003cli\u003eComplies with IEC 61008-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCCC217J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eOnekonekt – Hager's unified modular protection range, compatible with Hager single\/three-phase busbars\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Residual Operating Current (IΔn)\u003c\/td\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current Type\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e1500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Conditional Short-Circuit Current\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e83 x 35 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Width\u003c\/td\u003e\n\u003ctd\u003e2 modules (DIN 43880 size 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminal (BIconnect bottom connection, busbar-compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Capacity\u003c\/td\u003e\n\u003ctd\u003e1–25 mm² rigid \/ 1–16 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Index\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\/Transport Temperature\u003c\/td\u003e\n\u003ctd\u003e-55°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Endurance\u003c\/td\u003e\n\u003ctd\u003e4000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Endurance\u003c\/td\u003e\n\u003ctd\u003e2000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC 61008-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliant\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential apartments and villas\u003c\/li\u003e\n\u003cli\u003eCommercial buildings, offices, and shops\u003c\/li\u003e\n\u003cli\u003eEducational and healthcare facilities\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels requiring high safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB (Miniature Circuit Breaker) protects a circuit against overload and short-circuit faults. An RCCB (Residual Current Circuit Breaker), also known as an ELCB, continuously monitors for earth leakage current and disconnects the supply if current is escaping to earth – protecting against electric shock and fire in a way an MCB cannot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10mA sensitivity rating mean, and why is it so low?\u003c\/strong\u003e\u003cbr\u003e10mA is a specialist high-sensitivity rating, well below the standard 30mA personnel-protection threshold. RCCBs at this sensitivity are typically specified for locations needing an extra safety margin – such as medical equipment supplies, bathrooms\/wet areas, swimming pools, or sensitive electronic loads – where standard 30mA protection is not considered enough. Note: the manufacturer datasheet confirms the 10mA rating itself but does not name a specific end-use; the examples above reflect standard industry practice for this sensitivity class.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need for this circuit?\u003c\/strong\u003e\u003cbr\u003eThis is a 2-pole (2P) device switching both line and neutral, suited to single-phase circuits. Three-phase circuits require a 4-pole equivalent.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. This is a distribution-board-mounted device and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is Onekonekt?\u003c\/strong\u003e\u003cbr\u003eOnekonekt is Hager's unified range of modular protection devices – MCBs, RCCBs, RCBOs, and main switches – designed to fit a common single- or three-phase busbar system with BIconnect terminals, so devices can be wired from cables or fed directly from the busbar, speeding up panel-building and reducing wiring errors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"Hager","offers":[{"title":"Default Title","offer_id":41797546868835,"sku":"CCC217J","price":244.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/CCC217J.webp?v=1786954888"},{"product_id":"abb-elcb-f204-ac-40-0-1-4-pole-40a-100ma","title":"ABB ELCB F204 AC-40\/0.1 4-Pole 40A 100mA","description":"\u003ch2\u003eABB ELCB F204 AC-40\/0.1 4-Pole 40A 100mA\u003c\/h2\u003e\u003cp\u003eThe ABB F204 AC-40\/0.1 is a 4-pole Type AC RCCB rated 40A with 100mA tripping sensitivity for fire protection and general earth fault protection in UAE three-phase distribution boards and commercial installations. The 100mA sensitivity is ideal for main incoming fire-protection ELCB applications.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e40A 4-pole RCCB for three-phase DB incoming protection\u003c\/li\u003e\n\u003cli\u003e100mA fire-protection sensitivity (Type AC)\u003c\/li\u003e\n\u003cli\u003eSelective coordination with 30mA downstream RCCBs\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine ABB F200 series quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF204 AC-40\/0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e2CSF204005R2400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMain incoming fire protection in commercial DBs\u003c\/li\u003e\n\u003cli\u003eThree-phase distribution board incoming protection\u003c\/li\u003e\n\u003cli\u003eSelective ELCB schemes with 30mA downstream devices\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial building earth fault protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects circuits and wiring against overload and short-circuit current. An RCCB like this one protects against earth leakage by monitoring current imbalance and disconnecting the circuit — the two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e100mA RCCBs are sized for fire and equipment protection on larger circuits and sub-mains, not personal shock protection — that requires a 30mA device. A 100mA unit is a common choice as a main incomer or sub-distribution protection device upstream of 30mA final-circuit RCDs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 4-pole (4P) RCCB switches all three phases plus neutral together. Use 4P for three-phase supplies or distribution boards where the neutral must also be isolated; 2-pole devices are used for single-phase circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be used alongside MCBs in the same board?\u003c\/strong\u003e\u003cbr\u003eYes. This RCCB is typically installed upstream of the MCBs it protects, on the same DIN rail, so a leakage fault trips the RCCB while overloads\/short circuits are still cleared by the individual MCBs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCCBs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140747849827,"sku":"2CSF204005R2400","price":135.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/ELCB_RCCB_ABB_40A_4-Pole_100mA_FH204_AC_40_0.1_1024x1024_1f292c47-d394-4814-8c10-bde327187f78.webp?v=1786966190"},{"product_id":"abb-elcb-rccb-fh204-ac-63-0-1-4-pole-63a-100ma","title":"ABB ELCB\/RCCB FH204 AC-63\/0.1 4-Pole 63A 100mA","description":"\u003ch2\u003eABB ELCB\/RCCB FH204 AC-63\/0.1 4-Pole 63A 100mA\u003c\/h2\u003e\u003cp\u003eThe ABB FH204 AC-63\/0.1 is a 4-pole RCCB rated 63A with 100mA sensitivity for fire-protection earth fault protection on larger incoming circuits in UAE commercial distribution boards. It provides reliable leakage protection at the main incoming level where selective coordination with downstream 30mA devices is required.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e63A 4-pole RCCB for large three-phase incoming protection\u003c\/li\u003e\n\u003cli\u003e100mA sensitivity for fire-protection upstream ELCB duty\u003c\/li\u003e\n\u003cli\u003eType AC for sinusoidal AC residual currents\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine ABB FH200 series quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFH204 AC-63\/0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e2CSF204006R2630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMain incoming protection in commercial and industrial DBs\u003c\/li\u003e\n\u003cli\u003eSelective coordination with 30mA downstream devices\u003c\/li\u003e\n\u003cli\u003eThree-phase sub-main fire protection circuits\u003c\/li\u003e\n\u003cli\u003eFM and maintenance incoming protection replacements\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects circuits and wiring against overload and short-circuit current. An RCCB like this one protects against earth leakage by monitoring current imbalance and disconnecting the circuit — the two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e100mA RCCBs are sized for fire and equipment protection on larger circuits and sub-mains, not personal shock protection — that requires a 30mA device. A 100mA unit is a common choice as a main incomer or sub-distribution protection device upstream of 30mA final-circuit RCDs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 4-pole (4P) RCCB switches all three phases plus neutral together. Use 4P for three-phase supplies or distribution boards where the neutral must also be isolated; 2-pole devices are used for single-phase circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be used alongside MCBs in the same board?\u003c\/strong\u003e\u003cbr\u003eYes. This RCCB is typically installed upstream of the MCBs it protects, on the same DIN rail, so a leakage fault trips the RCCB while overloads\/short circuits are still cleared by the individual MCBs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCCBs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140747882595,"sku":"2CSF204006R2630","price":170.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000171034_400x400_1f5dbb64-9dcc-4fba-9f9a-0b925dd8f78c.png?v=1786966241"},{"product_id":"abb-elcb-rccb-fh202-ac-40-0-1-2-pole-40a-100ma","title":"ABB ELCB\/RCCB FH202 AC-40\/0.1 2-Pole 40A 100mA","description":"\u003ch2\u003eABB ELCB\/RCCB FH202 AC-40\/0.1 2-Pole 40A 100mA\u003c\/h2\u003e\u003cp\u003eThe ABB FH202 AC-40\/0.1 is a 2-pole RCCB rated 40A with 100mA sensitivity for earth fault and fire protection on single-phase incoming circuits in UAE residential and commercial distribution boards. The 100mA sensitivity provides the appropriate level of protection for upstream fire-protection ELCB applications on 2-pole boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e40A 2-pole RCCB for single-phase incoming protection\u003c\/li\u003e\n\u003cli\u003e100mA sensitivity for fire-protection upstream duty\u003c\/li\u003e\n\u003cli\u003eType AC for sinusoidal AC residual currents\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting for DB installation\u003c\/li\u003e\n\u003cli\u003eGenuine ABB FH200 series quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFH202 AC-40\/0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e2CSF202006R2400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eResidential and commercial single-phase DB incoming protection\u003c\/li\u003e\n\u003cli\u003eFire protection ELCB on single-phase boards\u003c\/li\u003e\n\u003cli\u003eUpstream coordination with 30mA downstream RCCBs\u003c\/li\u003e\n\u003cli\u003eConsumer unit main incoming protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects circuits and wiring against overload and short-circuit current. An RCCB like this one protects against earth leakage by monitoring current imbalance and disconnecting the circuit — the two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e100mA RCCBs are sized for fire and equipment protection on larger circuits and sub-mains, not personal shock protection — that requires a 30mA device. A 100mA unit is a common choice as a main incomer or sub-distribution protection device upstream of 30mA final-circuit RCDs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (2P) RCCB switches live and neutral on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be used alongside MCBs in the same board?\u003c\/strong\u003e\u003cbr\u003eYes. This RCCB is typically installed upstream of the MCBs it protects, on the same DIN rail, so a leakage fault trips the RCCB while overloads\/short circuits are still cleared by the individual MCBs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCCBs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140747980899,"sku":"2CSF202006R2400","price":135.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/ELCB_RCCB_ABB_40A_2-Pole_100mA_FH202_AC_40_0.1.webp?v=1786966253"},{"product_id":"abb-rccb-elcb-f204-100a-4-pole-100ma","title":"ABB RCCB\/ELCB F204 100A 4-Pole 100mA","description":"\u003ch2\u003eABB RCCB\/ELCB F204 100A 4-Pole 100mA\u003c\/h2\u003e\u003cp\u003eThe ABB F204 100A\/0.10\/4P is a 4-pole RCCB rated 100A with 100mA sensitivity for main incoming earth fault protection on large three-phase distribution boards in UAE commercial and industrial buildings. Its 100A rating makes it suitable for high-current incoming circuits where three-phase protection is required.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e100A 4-pole RCCB for high-current three-phase incoming protection\u003c\/li\u003e\n\u003cli\u003e100mA fire-protection sensitivity (Type AC)\u003c\/li\u003e\n\u003cli\u003eProvides selective coordination with downstream 30mA devices\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine ABB F200 series quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF204 AC-100\/0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e2CSF204005R2900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMain incoming protection on large 3-phase commercial DBs\u003c\/li\u003e\n\u003cli\u003eIndustrial distribution board earth fault protection\u003c\/li\u003e\n\u003cli\u003eSelective protection schemes with 30mA downstream ELCBs\u003c\/li\u003e\n\u003cli\u003eLarge commercial building three-phase incoming protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects circuits and wiring against overload and short-circuit current. An RCCB like this one protects against earth leakage by monitoring current imbalance and disconnecting the circuit — the two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e100mA RCCBs are sized for fire and equipment protection on larger circuits and sub-mains, not personal shock protection — that requires a 30mA device. A 100mA unit is a common choice as a main incomer or sub-distribution protection device upstream of 30mA final-circuit RCDs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 4-pole (4P) RCCB switches all three phases plus neutral together. Use 4P for three-phase supplies or distribution boards where the neutral must also be isolated; 2-pole devices are used for single-phase circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be used alongside MCBs in the same board?\u003c\/strong\u003e\u003cbr\u003eYes. This RCCB is typically installed upstream of the MCBs it protects, on the same DIN rail, so a leakage fault trips the RCCB while overloads\/short circuits are still cleared by the individual MCBs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCCBs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140748144739,"sku":"2CSF204005R2900","price":345.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000331028_400x400_bd60148f-fda7-4df2-aa1b-e9ab2dc20bcb.png?v=1786966255"},{"product_id":"abb-rccb-elcb-fh202-63a-2-pole-100ma","title":"ABB RCCB\/ELCB FH202 63A 2-Pole 100mA","description":"\u003ch2\u003eABB RCCB\/ELCB FH202 63A 2-Pole 100mA\u003c\/h2\u003e\u003cp\u003eThe ABB FH202 63A\/0.10\/2P is a 2-pole RCCB rated 63A with 100mA sensitivity for earth fault and fire protection on larger single-phase incoming circuits in UAE residential and commercial distribution boards. It is suitable for use as an upstream fire-protection ELCB on higher-current single-phase boards.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e63A 2-pole RCCB for single-phase high-current incoming protection\u003c\/li\u003e\n\u003cli\u003e100mA sensitivity for fire-protection upstream duty\u003c\/li\u003e\n\u003cli\u003eType AC for sinusoidal AC residual currents\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting\u003c\/li\u003e\n\u003cli\u003eGenuine ABB FH200 series quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFH202 AC-63\/0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e2CSF202006R2630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLarge single-phase incoming earth fault protection\u003c\/li\u003e\n\u003cli\u003eUpstream fire-protection ELCB on single-phase boards\u003c\/li\u003e\n\u003cli\u003eFM replacement for single-phase distribution boards\u003c\/li\u003e\n\u003cli\u003eResidential and commercial consumer unit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects circuits and wiring against overload and short-circuit current. An RCCB like this one protects against earth leakage by monitoring current imbalance and disconnecting the circuit — the two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 100mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e100mA RCCBs are sized for fire and equipment protection on larger circuits and sub-mains, not personal shock protection — that requires a 30mA device. A 100mA unit is a common choice as a main incomer or sub-distribution protection device upstream of 30mA final-circuit RCDs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 2-pole (2P) RCCB switches live and neutral on a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be used alongside MCBs in the same board?\u003c\/strong\u003e\u003cbr\u003eYes. This RCCB is typically installed upstream of the MCBs it protects, on the same DIN rail, so a leakage fault trips the RCCB while overloads\/short circuits are still cleared by the individual MCBs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCCBs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44140748177507,"sku":"2CSF202006R2630","price":175.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000328152_400x400_25f81c2f-df32-4a90-9155-474893dc6433.png?v=1786966262"},{"product_id":"abb-bmfw440-ac300-4p-40a-300ma-rccb","title":"ABB BMFW440\/AC300 Residual Current Circuit Breaker AC Type, 4P, 40A, 300mA","description":"\u003ch2\u003eABB BMFW440\/AC300 4-Pole 40A 300mA RCCB\u003c\/h2\u003e\n\u003cp\u003eThe BMFW440\/AC300 is a 4-pole 40A residual current circuit breaker (RCCB) with a 300mA AC-type sensitivity from ABB's Formula DIN Rail range. It protects people and installations against earth fault currents and is manufactured to IEC standards, making it suitable for three-phase distribution boards across UAE residential, commercial, and light industrial installations.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e4-pole configuration for three-phase and neutral circuit protection against earth leakage faults\u003c\/li\u003e\n  \u003cli\u003e300mA AC-type sensitivity suitable for general protection against fault currents in standard distribution circuits\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage of 230\/400V with a 4kV rated impulse withstand voltage for reliable insulation performance\u003c\/li\u003e\n  \u003cli\u003eIP20 degree of protection with an operating temperature range of -25°C to +55°C, suited to UAE ambient conditions\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB Formula Din Rail quality — rated for 10,000 electrical and mechanical operating cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMFW440\/AC300\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eRCCB (ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e300mA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage Type\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Voltage (Ur)\u003c\/td\u003e\n\u003ctd\u003e230\/400V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eConnecting Capacity\u003c\/td\u003e\n\u003ctd\u003eFlexible 35mm² \/ Solid 25mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eElectrical \u0026amp; Mechanical Endurance\u003c\/td\u003e\n\u003ctd\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAmbient Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth fault protection for three-phase distribution boards in villas and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eMain incomer protection for sub-distribution boards in FM-managed facilities\u003c\/li\u003e\n  \u003cli\u003eFault current protection for HVAC and pump motor circuits in commercial installations\u003c\/li\u003e\n  \u003cli\u003eGeneral earth leakage protection in retail, warehouse, and light industrial panels across the UAE\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects circuits and wiring against overload and short-circuit current. An RCCB like this one protects against earth leakage by monitoring current imbalance and disconnecting the circuit — the two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 300mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e300mA RCCBs are sized for fire and equipment protection on larger circuits and sub-mains, not personal shock protection — that requires a 30mA device. A 300mA unit is a common choice as a main incomer or sub-distribution protection device upstream of 30mA final-circuit RCDs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 4-pole (4P) RCCB switches all three phases plus neutral together. Use 4P for three-phase supplies or distribution boards where the neutral must also be isolated; 2-pole devices are used for single-phase circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be used alongside MCBs in the same board?\u003c\/strong\u003e\u003cbr\u003eYes. This RCCB is typically installed upstream of the MCBs it protects, on the same DIN rail, so a leakage fault trips the RCCB while overloads\/short circuits are still cleared by the individual MCBs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCCBs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44352331939939,"sku":"1SYF604062R3400","price":290.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000216758_400x400_03f1c91a-6a7c-4792-8b4e-6533eb6499f7.png?v=1787498884"},{"product_id":"abb-bmfw463-ac300-4p-63a-300ma-rccb","title":"ABB BMFW463\/AC300 Residual Current Circuit Breaker AC Type, 4P, 63A, 300mA","description":"\u003ch2\u003eABB BMFW463\/AC300 4-Pole 63A 300mA RCCB\u003c\/h2\u003e\n\u003cp\u003eThe BMFW463\/AC300 is a 4-pole 63A residual current circuit breaker (RCCB) with a 300mA AC-type sensitivity from ABB's Formula DIN Rail range. It protects people and installations against earth fault currents and is manufactured to IEC standards, making it well suited to higher-load three-phase distribution boards across UAE residential, commercial, and light industrial installations.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e4-pole configuration for three-phase and neutral circuit protection against earth leakage faults\u003c\/li\u003e\n  \u003cli\u003e63A rated current supports higher-load distribution circuits than smaller-frame RCCBs in the same series\u003c\/li\u003e\n  \u003cli\u003e300mA AC-type sensitivity suitable for general protection against fault currents in standard distribution circuits\u003c\/li\u003e\n  \u003cli\u003eIP20 degree of protection with an operating temperature range of -25°C to +55°C, suited to UAE ambient conditions\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB Formula Din Rail quality — rated for 10,000 electrical and mechanical operating cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMFW463\/AC300\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eRCCB (ELCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e300mA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage Type\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Voltage (Ur)\u003c\/td\u003e\n\u003ctd\u003e230\/400V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eConnecting Capacity\u003c\/td\u003e\n\u003ctd\u003eFlexible 35mm² \/ Solid 25mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eElectrical \u0026amp; Mechanical Endurance\u003c\/td\u003e\n\u003ctd\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAmbient Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth fault protection for higher-capacity three-phase distribution boards in villas and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eMain incomer protection for sub-distribution boards in FM-managed facilities\u003c\/li\u003e\n  \u003cli\u003eFault current protection for HVAC, chiller, and pump motor circuits in commercial installations\u003c\/li\u003e\n  \u003cli\u003eGeneral earth leakage protection in retail, warehouse, and light industrial panels across the UAE\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between an MCB and an RCCB\/RCD?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects circuits and wiring against overload and short-circuit current. An RCCB like this one protects against earth leakage by monitoring current imbalance and disconnecting the circuit — the two are complementary and are normally installed together in a distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 300mA sensitivity rating mean?\u003c\/strong\u003e\u003cbr\u003e300mA RCCBs are sized for fire and equipment protection on larger circuits and sub-mains, not personal shock protection — that requires a 30mA device. A 300mA unit is a common choice as a main incomer or sub-distribution protection device upstream of 30mA final-circuit RCDs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles do I need?\u003c\/strong\u003e\u003cbr\u003eA 4-pole (4P) RCCB switches all three phases plus neutral together. Use 4P for three-phase supplies or distribution boards where the neutral must also be isolated; 2-pole devices are used for single-phase circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this be used alongside MCBs in the same board?\u003c\/strong\u003e\u003cbr\u003eYes. This RCCB is typically installed upstream of the MCBs it protects, on the same DIN rail, so a leakage fault trips the RCCB while overloads\/short circuits are still cleared by the individual MCBs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I install this myself?\u003c\/strong\u003e\u003cbr\u003eNo. RCCBs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44352345702499,"sku":"1SYF604062R3630","price":251.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000216761_400x400_aa9d06fe-3c62-4982-a929-80ea9c6780d0.png?v=1787498885"}],"url":"https:\/\/www.deluxeuae.com\/collections\/elcbs.oembed","provider":"Deluxe Electricals","version":"1.0","type":"link"}