{"title":"Cable \u0026 Wires","description":"\u003cp\u003eShop RR Kabel cable and wire for UAE installations — single-core building wire, finely stranded panel wire, multi-core PVC flexible cable and XLPE\/SWA armoured cable, in sizes from 0.5mm² to 120mm², including green and yellow earth wire.\u003c\/p\u003e\u003ch2\u003eBuilding wire, panel wire or flexible cable?\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eBuilding wire\u003c\/strong\u003e is single-core and relatively stiff — the conductor pulled through conduit and trunking in a fixed installation, bought as separate colours. \u003cstrong\u003ePanel wire\u003c\/strong\u003e is also single-core but finely stranded, so it turns tight corners inside distribution boards and control panels. \u003cstrong\u003eMulti-core flexible cable\u003c\/strong\u003e carries two to five cores under one sheath, for appliance tails, machine drops and equipment connections where the run has to move.\u003c\/p\u003e\u003ch2\u003eWhen do I need armoured cable?\u003c\/h2\u003e\u003cp\u003eXLPE\/SWA cable adds a steel wire layer beneath the outer sheath, giving mechanical protection wherever a run leaves a protected indoor route: buried lengths, external walls, plant yards, submains between buildings, and feeds to pumps and chillers. Stocked in three- and four-core, 4mm² to 95mm². Plain PVC cable is not a substitute in those positions.\u003c\/p\u003e\u003ch2\u003eDoes UAE heat change what I should order?\u003c\/h2\u003e\u003cp\u003eIt does. A conductor's current-carrying capacity is quoted against a reference ambient temperature and falls as the surrounding air gets hotter, which matters in roof voids, plant rooms and outdoor risers here. Bunching several cables together reduces it again, and a long run brings voltage drop into the calculation. Insulation temperature ratings also differ between products, so read what is printed on the sheath.\u003c\/p\u003e\u003cp\u003eCable sizing and the installation of fixed wiring is a licensed electrician's decision, made against the real load, route and protective device. Send us your cable schedule and we will quote the lengths in AED.\u003c\/p\u003e","products":[{"product_id":"rr-building-wire-1-0mm-single-core","title":"RR Kabel 1.0mm² Single-Core Building Wire","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Building Wire 1.0mm² Single Core\u003c\/h2\u003e\n\u003cp\u003eThe RR Building Wire 1.0mm² Single Core is a general-purpose fixed-wiring conductor for light electrical circuits in residential and commercial buildings. Available per metre, it is ideal for UAE contractors and electricians needing reliable, flexible ordering for small circuit runs, junction boxes, and internal wiring projects.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1.0mm² cross-section for light-duty fixed wiring circuits\u003c\/li\u003e\n\u003cli\u003eSingle-core construction for easy circuit segregation\u003c\/li\u003e\n\u003cli\u003ePVC insulation rated for standard building wiring applications\u003c\/li\u003e\n\u003cli\u003eSold per metre — order exactly the length you need\u003c\/li\u003e\n\u003cli\u003eGenuine RR Cables quality, trusted across the UAE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e1.0mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e450\/750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Packing\u003c\/td\u003e\n\u003ctd\u003e100m standard coil (longer lengths available on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-15°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDomestic lighting circuits and socket ring mains\u003c\/li\u003e\n\u003cli\u003eInternal fixed wiring in residential properties\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical installations\u003c\/li\u003e\n\u003cli\u003eJunction box and panel internal wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 1.0mm² cross-section rating mean, and how do I pick the right size for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe mm² figure is the conductor's copper cross-sectional area, which determines how much current the wire can safely carry and its voltage drop over distance. Larger cross-sections carry higher currents over longer runs. Confirm the correct size for your circuit's load and cable length against the applicable wiring regulations (or ask our technical team) before ordering — this listing is for the conductor itself, not a substitute for a proper circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this wire is sold per metre, so you enter the exact quantity of metres you need at checkout and are charged accordingly. There's no minimum roll or coil requirement; order 5 metres or 500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between Single-Core Building Wire and RR Kabel's Flexible Panel Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire uses a solid or low-strand-count conductor designed for fixed, permanent installation in walls, conduit, and trunking. Flexible Panel Wire uses a finer, multi-strand flexible conductor designed for movement and repeated flexing inside control panels and switchboards. Use Building Wire for fixed circuit wiring; use Flexible Panel Wire for panel\/control cabinet internal wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eYes. Fixed building wiring must be installed and terminated by a licensed electrician in line with UAE wiring regulations — this is a supply-only conductor, not a DIY plug-and-play product.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy do the colours (Red\/Yellow\/Blue\/Black) matter, and can I mix colours in one order?\u003c\/strong\u003e\u003cbr\u003eColour-coding identifies phase, neutral, and circuit function so an electrician can trace and safely isolate circuits later. You can order any mix of colours and lengths in the same purchase — each colour is simply a separate variant of the same 1.0mm² wire.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Red","offer_id":44138575298659,"sku":"RR-BW-1.0-RED","price":18.0,"currency_code":"AED","in_stock":true},{"title":"Yellow","offer_id":44138575331427,"sku":"RR-BW-1.0-YLW","price":18.0,"currency_code":"AED","in_stock":true},{"title":"Blue","offer_id":44138575364195,"sku":"RR-BW-1.0-BLK-3","price":18.0,"currency_code":"AED","in_stock":true},{"title":"Black","offer_id":44138575396963,"sku":"RR-BW-1.0-BLK-4","price":18.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_ad880ecf-53ff-4f7b-941a-1a9991e806f4.png?v=1786965892"},{"product_id":"rr-building-wire-1-5mm-single-core","title":"RR Kabel 1.5mm² Single-Core Building Wire","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Building Wire 1.5mm² Single Core\u003c\/h2\u003e\n\u003cp\u003eThe RR Building Wire 1.5mm² Single Core is one of the most widely used conductors in UAE residential and commercial wiring. Available in Black, Red, White, and Yellow\/Green, it suits lighting circuits, socket outlets, and fixed wiring installations. Sold per metre for precise project ordering.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1.5mm² conductor — the standard size for lighting and light power circuits\u003c\/li\u003e\n\u003cli\u003eAvailable in multiple colours for phase, neutral, and earth identification\u003c\/li\u003e\n\u003cli\u003ePVC insulation for reliable performance in fixed wiring applications\u003c\/li\u003e\n\u003cli\u003eSold per metre — no minimum roll quantity required\u003c\/li\u003e\n\u003cli\u003eGenuine RR Cables product, widely used by UAE contractors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e1.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e450\/750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Colours\u003c\/td\u003e\n\u003ctd\u003eBlack, Red, White, Yellow\/Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Packing\u003c\/td\u003e\n\u003ctd\u003e100m standard coil (longer lengths available on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-15°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential and commercial lighting circuits\u003c\/li\u003e\n\u003cli\u003eSocket outlet and ring main wiring\u003c\/li\u003e\n\u003cli\u003eFixed internal wiring in buildings\u003c\/li\u003e\n\u003cli\u003eEarth continuity conductors (Yellow\/Green)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 1.5mm² cross-section rating mean, and how do I pick the right size for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe mm² figure is the conductor's copper cross-sectional area, which determines how much current the wire can safely carry and its voltage drop over distance. Larger cross-sections carry higher currents over longer runs. Confirm the correct size for your circuit's load and cable length against the applicable wiring regulations (or ask our technical team) before ordering — this listing is for the conductor itself, not a substitute for a proper circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this wire is sold per metre, so you enter the exact quantity of metres you need at checkout and are charged accordingly. There's no minimum roll or coil requirement; order 5 metres or 500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between Single-Core Building Wire and RR Kabel's Flexible Panel Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire uses a solid or low-strand-count conductor designed for fixed, permanent installation in walls, conduit, and trunking. Flexible Panel Wire uses a finer, multi-strand flexible conductor designed for movement and repeated flexing inside control panels and switchboards. Use Building Wire for fixed circuit wiring; use Flexible Panel Wire for panel\/control cabinet internal wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eYes. Fixed building wiring must be installed and terminated by a licensed electrician in line with UAE wiring regulations — this is a supply-only conductor, not a DIY plug-and-play product.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy do the colours (Red\/Yellow\/Blue\/Black) matter, and can I mix colours in one order?\u003c\/strong\u003e\u003cbr\u003eColour-coding identifies phase, neutral, and circuit function so an electrician can trace and safely isolate circuits later. You can order any mix of colours and lengths in the same purchase — each colour is simply a separate variant of the same 1.5mm² wire.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Red","offer_id":44124918120547,"sku":"RR-BW-1.5-BLK","price":18.0,"currency_code":"AED","in_stock":true},{"title":"Yellow","offer_id":44138600464483,"sku":"RR-BW-1.5-BLK-1","price":18.0,"currency_code":"AED","in_stock":true},{"title":"Blue","offer_id":44138600497251,"sku":"RR-BW-1.5-BLK-2","price":18.0,"currency_code":"AED","in_stock":true},{"title":"Black","offer_id":44138600530019,"sku":"RR-BW-1.5-BLK-3","price":18.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_ad880ecf-53ff-4f7b-941a-1a9991e806f4.png?v=1786965892"},{"product_id":"rr-building-wire-120mm-single-core","title":"RR Kabel 120mm² Single-Core Building Wire","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Building Wire 120mm² Single Core\u003c\/h2\u003e\n\u003cp\u003eThe RR Building Wire 120mm² Single Core is a very large cross-section conductor for main incoming supply cables, high-capacity sub-mains, and heavy industrial distribution in UAE large commercial and industrial projects. It handles the highest current demands in building electrical systems and is suited for cable tray and trunking installation.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e120mm² conductor for main incoming and high-capacity distribution circuits\u003c\/li\u003e\n\u003cli\u003eExceptional current-carrying capacity for large commercial loads\u003c\/li\u003e\n\u003cli\u003ePVC insulation for cable tray and trunking installations\u003c\/li\u003e\n\u003cli\u003eSold per metre for precise large-project quantities\u003c\/li\u003e\n\u003cli\u003eGenuine RR Cables quality for demanding specifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e120mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e450\/750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Packing\u003c\/td\u003e\n\u003ctd\u003e100m standard coil (longer lengths available on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-15°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain incoming supply and switchgear connections\u003c\/li\u003e\n\u003cli\u003eHigh-capacity sub-main distribution runs\u003c\/li\u003e\n\u003cli\u003eLarge industrial plant and machinery feeder cables\u003c\/li\u003e\n\u003cli\u003eData centre and critical infrastructure power distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 120mm² cross-section rating mean, and how do I pick the right size for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe mm² figure is the conductor's copper cross-sectional area, which determines how much current the wire can safely carry and its voltage drop over distance. Larger cross-sections carry higher currents over longer runs. Confirm the correct size for your circuit's load and cable length against the applicable wiring regulations (or ask our technical team) before ordering — this listing is for the conductor itself, not a substitute for a proper circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this wire is sold per metre, so you enter the exact quantity of metres you need at checkout and are charged accordingly. There's no minimum roll or coil requirement; order 5 metres or 500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between Single-Core Building Wire and RR Kabel's Flexible Panel Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire uses a solid or low-strand-count conductor designed for fixed, permanent installation in walls, conduit, and trunking. Flexible Panel Wire uses a finer, multi-strand flexible conductor designed for movement and repeated flexing inside control panels and switchboards. Use Building Wire for fixed circuit wiring; use Flexible Panel Wire for panel\/control cabinet internal wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eYes. Fixed building wiring must be installed and terminated by a licensed electrician in line with UAE wiring regulations — this is a supply-only conductor, not a DIY plug-and-play product.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy do the colours (Red\/Yellow\/Blue\/Black) matter, and can I mix colours in one order?\u003c\/strong\u003e\u003cbr\u003eColour-coding identifies phase, neutral, and circuit function so an electrician can trace and safely isolate circuits later. You can order any mix of colours and lengths in the same purchase — each colour is simply a separate variant of the same 120mm² wire.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Red","offer_id":44124918284387,"sku":"RR-BW-120-RED","price":75.0,"currency_code":"AED","in_stock":true},{"title":"Yellow","offer_id":44138609508451,"sku":"RR-BW-120-YEL","price":75.0,"currency_code":"AED","in_stock":true},{"title":"Blue","offer_id":44138609541219,"sku":"RR-BW-120-BL","price":75.0,"currency_code":"AED","in_stock":true},{"title":"Black","offer_id":44138609573987,"sku":"RR-BW-120-BLK","price":75.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_ad880ecf-53ff-4f7b-941a-1a9991e806f4.png?v=1786965892"},{"product_id":"rr-building-wire-2-5mm-single-core","title":"RR Kabel 2.5mm² Single-Core Building Wire","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Building Wire 2.5mm² Single Core\u003c\/h2\u003e\n\u003cp\u003eThe RR Building Wire 2.5mm² Single Core is the standard conductor for power socket circuits, cooker connections, and general power wiring in UAE residential and commercial properties. Available in Yellow\/Green for earth applications, sold per metre for accurate project quantities.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2.5mm² conductor for power circuits up to 20A\u003c\/li\u003e\n\u003cli\u003eSingle-core for flexible circuit design and colour coding\u003c\/li\u003e\n\u003cli\u003ePVC insulation suitable for concealed and conduit wiring\u003c\/li\u003e\n\u003cli\u003eSold per metre for precise ordering\u003c\/li\u003e\n\u003cli\u003eGenuine RR Cables quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e2.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e450\/750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Packing\u003c\/td\u003e\n\u003ctd\u003e100m standard coil (longer lengths available on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-15°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSocket outlet ring main circuits\u003c\/li\u003e\n\u003cli\u003eCooker and appliance connection wiring\u003c\/li\u003e\n\u003cli\u003eGeneral power wiring in homes and offices\u003c\/li\u003e\n\u003cli\u003eEarth continuity conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 2.5mm² cross-section rating mean, and how do I pick the right size for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe mm² figure is the conductor's copper cross-sectional area, which determines how much current the wire can safely carry and its voltage drop over distance. Larger cross-sections carry higher currents over longer runs. Confirm the correct size for your circuit's load and cable length against the applicable wiring regulations (or ask our technical team) before ordering — this listing is for the conductor itself, not a substitute for a proper circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this wire is sold per metre, so you enter the exact quantity of metres you need at checkout and are charged accordingly. There's no minimum roll or coil requirement; order 5 metres or 500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between Single-Core Building Wire and RR Kabel's Flexible Panel Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire uses a solid or low-strand-count conductor designed for fixed, permanent installation in walls, conduit, and trunking. Flexible Panel Wire uses a finer, multi-strand flexible conductor designed for movement and repeated flexing inside control panels and switchboards. Use Building Wire for fixed circuit wiring; use Flexible Panel Wire for panel\/control cabinet internal wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eYes. Fixed building wiring must be installed and terminated by a licensed electrician in line with UAE wiring regulations — this is a supply-only conductor, not a DIY plug-and-play product.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy do the colours (Red\/Yellow\/Blue\/Black) matter, and can I mix colours in one order?\u003c\/strong\u003e\u003cbr\u003eColour-coding identifies phase, neutral, and circuit function so an electrician can trace and safely isolate circuits later. You can order any mix of colours and lengths in the same purchase — each colour is simply a separate variant of the same 2.5mm² wire.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Red","offer_id":44124918317155,"sku":"RR-BW-2.5-YG","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Yellow","offer_id":44138612195427,"sku":"RR-BW-2.5-YG-1","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Blue","offer_id":44138612228195,"sku":"RR-BW-2.5-YG-2","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Black","offer_id":44138612260963,"sku":"RR-BW-2.5-YG-3","price":19.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_ad880ecf-53ff-4f7b-941a-1a9991e806f4.png?v=1786965892"},{"product_id":"rr-building-wire-25mm-single-core","title":"RR Kabel 25mm² Single-Core Building Wire","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Building Wire 25mm² Single Core\u003c\/h2\u003e\n\u003cp\u003eThe RR Building Wire 25mm² Single Core is a large-section conductor for sub-main distribution, high-current feeder cables, and industrial power wiring in UAE buildings. Suitable for installation in conduit, trunking, and cable trays where high current-carrying capacity is required at medium distribution voltage levels.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e25mm² conductor for heavy sub-main and feeder applications\u003c\/li\u003e\n\u003cli\u003eSingle-core for flexible multi-phase circuit construction\u003c\/li\u003e\n\u003cli\u003ePVC insulation for conduit and trunking installations\u003c\/li\u003e\n\u003cli\u003eSold per metre for accurate large-project ordering\u003c\/li\u003e\n\u003cli\u003eGenuine RR Cables quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e25mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e450\/750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Packing\u003c\/td\u003e\n\u003ctd\u003e100m standard coil (longer lengths available on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-15°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSub-main distribution board feeder cables\u003c\/li\u003e\n\u003cli\u003eIndustrial machinery and plant power wiring\u003c\/li\u003e\n\u003cli\u003eHigh-current commercial installation wiring\u003c\/li\u003e\n\u003cli\u003eConduit and cable tray installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 25mm² cross-section rating mean, and how do I pick the right size for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe mm² figure is the conductor's copper cross-sectional area, which determines how much current the wire can safely carry and its voltage drop over distance. Larger cross-sections carry higher currents over longer runs. Confirm the correct size for your circuit's load and cable length against the applicable wiring regulations (or ask our technical team) before ordering — this listing is for the conductor itself, not a substitute for a proper circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this wire is sold per metre, so you enter the exact quantity of metres you need at checkout and are charged accordingly. There's no minimum roll or coil requirement; order 5 metres or 500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between Single-Core Building Wire and RR Kabel's Flexible Panel Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire uses a solid or low-strand-count conductor designed for fixed, permanent installation in walls, conduit, and trunking. Flexible Panel Wire uses a finer, multi-strand flexible conductor designed for movement and repeated flexing inside control panels and switchboards. Use Building Wire for fixed circuit wiring; use Flexible Panel Wire for panel\/control cabinet internal wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eYes. Fixed building wiring must be installed and terminated by a licensed electrician in line with UAE wiring regulations — this is a supply-only conductor, not a DIY plug-and-play product.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy do the colours (Red\/Yellow\/Blue\/Black) matter, and can I mix colours in one order?\u003c\/strong\u003e\u003cbr\u003eColour-coding identifies phase, neutral, and circuit function so an electrician can trace and safely isolate circuits later. You can order any mix of colours and lengths in the same purchase — each colour is simply a separate variant of the same 25mm² wire.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Red","offer_id":44124918349923,"sku":"RR-BW-25-NAT","price":29.0,"currency_code":"AED","in_stock":true},{"title":"Yellow","offer_id":44138613178467,"sku":"RR-BW-25-NAT-1","price":29.0,"currency_code":"AED","in_stock":true},{"title":"Blue","offer_id":44138613211235,"sku":"RR-BW-25-NAT-2","price":29.0,"currency_code":"AED","in_stock":true},{"title":"Black","offer_id":44138613244003,"sku":"RR-BW-25-NAT-3","price":29.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_ad880ecf-53ff-4f7b-941a-1a9991e806f4.png?v=1786965892"},{"product_id":"rr-building-wire-35mm-single-core","title":"RR Kabel 35mm² Single-Core Building Wire","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Building Wire 35mm² Single Core\u003c\/h2\u003e\n\u003cp\u003eThe RR Building Wire 35mm² Single Core is a large cross-section conductor for main distribution feeders, sub-mains, and heavy industrial power circuits in UAE commercial and industrial projects. It provides the current capacity required for high-load three-phase and single-phase distribution runs in conduit or cable tray.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e35mm² cross-section for main feeder and sub-main distribution\u003c\/li\u003e\n\u003cli\u003eHigh current-carrying capacity for heavy commercial loads\u003c\/li\u003e\n\u003cli\u003ePVC insulation for conduit and tray installations\u003c\/li\u003e\n\u003cli\u003eSold per metre for large-project precision ordering\u003c\/li\u003e\n\u003cli\u003eGenuine RR Cables quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e35mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e450\/750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Packing\u003c\/td\u003e\n\u003ctd\u003e100m standard coil (longer lengths available on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-15°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain distribution board feeder wiring\u003c\/li\u003e\n\u003cli\u003eHeavy industrial machinery power supply\u003c\/li\u003e\n\u003cli\u003eThree-phase sub-main distribution runs\u003c\/li\u003e\n\u003cli\u003eLarge commercial and industrial building electrical systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 35mm² cross-section rating mean, and how do I pick the right size for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe mm² figure is the conductor's copper cross-sectional area, which determines how much current the wire can safely carry and its voltage drop over distance. Larger cross-sections carry higher currents over longer runs. Confirm the correct size for your circuit's load and cable length against the applicable wiring regulations (or ask our technical team) before ordering — this listing is for the conductor itself, not a substitute for a proper circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this wire is sold per metre, so you enter the exact quantity of metres you need at checkout and are charged accordingly. There's no minimum roll or coil requirement; order 5 metres or 500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between Single-Core Building Wire and RR Kabel's Flexible Panel Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire uses a solid or low-strand-count conductor designed for fixed, permanent installation in walls, conduit, and trunking. Flexible Panel Wire uses a finer, multi-strand flexible conductor designed for movement and repeated flexing inside control panels and switchboards. Use Building Wire for fixed circuit wiring; use Flexible Panel Wire for panel\/control cabinet internal wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eYes. Fixed building wiring must be installed and terminated by a licensed electrician in line with UAE wiring regulations — this is a supply-only conductor, not a DIY plug-and-play product.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy do the colours (Red\/Yellow\/Blue\/Black) matter, and can I mix colours in one order?\u003c\/strong\u003e\u003cbr\u003eColour-coding identifies phase, neutral, and circuit function so an electrician can trace and safely isolate circuits later. You can order any mix of colours and lengths in the same purchase — each colour is simply a separate variant of the same 35mm² wire.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Red","offer_id":44124918382691,"sku":"RR-BW-35-YG","price":30.0,"currency_code":"AED","in_stock":true},{"title":"Yellow","offer_id":44138621894755,"sku":"RR-BW-35-YG-1","price":30.0,"currency_code":"AED","in_stock":true},{"title":"Blue","offer_id":44138621927523,"sku":"RR-BW-35-YG-2","price":30.0,"currency_code":"AED","in_stock":true},{"title":"Black","offer_id":44138621960291,"sku":"RR-BW-35-YG-3","price":30.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_ad880ecf-53ff-4f7b-941a-1a9991e806f4.png?v=1786965892"},{"product_id":"rr-building-wire-4-0mm-single-core","title":"RR Kabel 4.0mm² Single-Core Building Wire","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Building Wire 4.0mm² Single Core\u003c\/h2\u003e\n\u003cp\u003eThe RR Building Wire 4.0mm² Single Core is a heavy-duty single-core conductor for power circuits, sub-mains, and high-load fixed wiring in UAE commercial and industrial buildings. Available in Black, Blue, Red, Yellow, and Yellow\/Green, it covers all phase, neutral, and earth requirements. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4.0mm² conductor for circuits up to 32A\u003c\/li\u003e\n\u003cli\u003eFull colour range: Black, Blue, Red, Yellow, Yellow\/Green\u003c\/li\u003e\n\u003cli\u003ePVC insulation for conduit, trunking, and tray installations\u003c\/li\u003e\n\u003cli\u003eSold per metre for flexible project ordering\u003c\/li\u003e\n\u003cli\u003eGenuine RR Cables quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e4.0mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e450\/750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Colours\u003c\/td\u003e\n\u003ctd\u003eBlack, Blue, Red, Yellow, Yellow\/Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Packing\u003c\/td\u003e\n\u003ctd\u003e100m standard coil (longer lengths available on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-15°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShower, cooker, and high-load appliance circuits\u003c\/li\u003e\n\u003cli\u003eSub-main distribution wiring\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial power distribution\u003c\/li\u003e\n\u003cli\u003eEarth bonding conductors (Yellow\/Green)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 4.0mm² cross-section rating mean, and how do I pick the right size for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe mm² figure is the conductor's copper cross-sectional area, which determines how much current the wire can safely carry and its voltage drop over distance. Larger cross-sections carry higher currents over longer runs. Confirm the correct size for your circuit's load and cable length against the applicable wiring regulations (or ask our technical team) before ordering — this listing is for the conductor itself, not a substitute for a proper circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this wire is sold per metre, so you enter the exact quantity of metres you need at checkout and are charged accordingly. There's no minimum roll or coil requirement; order 5 metres or 500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between Single-Core Building Wire and RR Kabel's Flexible Panel Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire uses a solid or low-strand-count conductor designed for fixed, permanent installation in walls, conduit, and trunking. Flexible Panel Wire uses a finer, multi-strand flexible conductor designed for movement and repeated flexing inside control panels and switchboards. Use Building Wire for fixed circuit wiring; use Flexible Panel Wire for panel\/control cabinet internal wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eYes. Fixed building wiring must be installed and terminated by a licensed electrician in line with UAE wiring regulations — this is a supply-only conductor, not a DIY plug-and-play product.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy do the colours (Red\/Yellow\/Blue\/Black) matter, and can I mix colours in one order?\u003c\/strong\u003e\u003cbr\u003eColour-coding identifies phase, neutral, and circuit function so an electrician can trace and safely isolate circuits later. You can order any mix of colours and lengths in the same purchase — each colour is simply a separate variant of the same 4.0mm² wire.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Red","offer_id":44124918415459,"sku":"RR-BW-4.0-BLK","price":21.0,"currency_code":"AED","in_stock":true},{"title":"Yellow","offer_id":44138623205475,"sku":"RR-BW-4.0-BLK-1","price":21.0,"currency_code":"AED","in_stock":true},{"title":"Blue","offer_id":44138623238243,"sku":"RR-BW-4.0-BLK-2","price":21.0,"currency_code":"AED","in_stock":true},{"title":"Black","offer_id":44138623271011,"sku":"RR-BW-4.0-BLK-3","price":21.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_ad880ecf-53ff-4f7b-941a-1a9991e806f4.png?v=1786965892"},{"product_id":"rr-building-wire-6-0mm-single-core","title":"RR Kabel 6.0mm² Single-Core Building Wire","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Building Wire 6.0mm² Single Core\u003c\/h2\u003e\n\u003cp\u003eThe RR Building Wire 6.0mm² Single Core is a robust conductor for high-current fixed wiring, sub-mains, and distribution circuits in UAE commercial and industrial installations. Available in Black, Blue, Red, and Yellow, it is suitable for conduit and trunking installations where reliable current-carrying capacity is required.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e6.0mm² conductor rated up to 41A in conduit\u003c\/li\u003e\n\u003cli\u003eAvailable in Black, Blue, Red, and Yellow\u003c\/li\u003e\n\u003cli\u003ePVC insulation for standard building wiring environments\u003c\/li\u003e\n\u003cli\u003eSold per metre for accurate project quantities\u003c\/li\u003e\n\u003cli\u003eGenuine RR Cables quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e6.0mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e450\/750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Colours\u003c\/td\u003e\n\u003ctd\u003eBlack, Blue, Red, Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Packing\u003c\/td\u003e\n\u003ctd\u003e100m standard coil (longer lengths available on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-15°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSub-main and distribution board wiring\u003c\/li\u003e\n\u003cli\u003eHigh-load appliance and HVAC circuits\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial power installations\u003c\/li\u003e\n\u003cli\u003eConduit and cable tray installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6.0mm² cross-section rating mean, and how do I pick the right size for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe mm² figure is the conductor's copper cross-sectional area, which determines how much current the wire can safely carry and its voltage drop over distance. Larger cross-sections carry higher currents over longer runs. Confirm the correct size for your circuit's load and cable length against the applicable wiring regulations (or ask our technical team) before ordering — this listing is for the conductor itself, not a substitute for a proper circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this wire is sold per metre, so you enter the exact quantity of metres you need at checkout and are charged accordingly. There's no minimum roll or coil requirement; order 5 metres or 500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between Single-Core Building Wire and RR Kabel's Flexible Panel Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire uses a solid or low-strand-count conductor designed for fixed, permanent installation in walls, conduit, and trunking. Flexible Panel Wire uses a finer, multi-strand flexible conductor designed for movement and repeated flexing inside control panels and switchboards. Use Building Wire for fixed circuit wiring; use Flexible Panel Wire for panel\/control cabinet internal wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eYes. Fixed building wiring must be installed and terminated by a licensed electrician in line with UAE wiring regulations — this is a supply-only conductor, not a DIY plug-and-play product.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy do the colours (Red\/Yellow\/Blue\/Black) matter, and can I mix colours in one order?\u003c\/strong\u003e\u003cbr\u003eColour-coding identifies phase, neutral, and circuit function so an electrician can trace and safely isolate circuits later. You can order any mix of colours and lengths in the same purchase — each colour is simply a separate variant of the same 6.0mm² wire.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Red","offer_id":44124918644835,"sku":"RR-BW-6.0-RED","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Yellow","offer_id":44124918677603,"sku":"RR-BW-6.0-YEL","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Blue","offer_id":44124918612067,"sku":"RR-BW-6.0-BLU","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Black","offer_id":44124918579299,"sku":"RR-BW-6.0-BLK","price":19.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_ad880ecf-53ff-4f7b-941a-1a9991e806f4.png?v=1786965892"},{"product_id":"rr-flexible-panel-wire-0-5mm-single-core","title":"RR Kabel 0.5mm² Single-Core Flexible Panel Wire","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Kabel 0.5mm² Single-Core Flexible Panel Wire\u003c\/h2\u003e\n\u003cp\u003eThe RR Flexible Panel Wire 0.5mm² Single Core is a fine-stranded conductor for internal wiring in control panels, instrument enclosures, and low-current circuit connections. Available in Black, Red, Blue, Yellow, and Yellow\/Green. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e0.5mm² fine-stranded conductor for flexible panel wiring\u003c\/li\u003e\n\u003cli\u003e5 colours for circuit identification\u003c\/li\u003e\n\u003cli\u003ePVC insulation for standard panel environments\u003c\/li\u003e\n\u003cli\u003eSold per metre\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCross-Section\u003c\/td\u003e\n\u003ctd\u003e0.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Type\u003c\/td\u003e\n\u003ctd\u003eFlexible (fine stranded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Colours\u003c\/td\u003e\n\u003ctd\u003eBlack, Red, Blue, Yellow, Yellow\/Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standard\u003c\/td\u003e\n\u003ctd\u003eEN 50525-2-31 (H05V-K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Class\u003c\/td\u003e\n\u003ctd\u003eClass 5 flexible, per EN 60228\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInternal control panel and instrument wiring\u003c\/li\u003e\n\u003cli\u003ePLC and relay panel interconnections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 0.5mm² cross-section rating mean?\u003c\/strong\u003e\u003cbr\u003eThe cross-section is the copper conductor's area in square millimetres, which determines how much current it can safely carry. 0.5mm² is suited to low-current control, signal, and instrumentation circuits (e.g. PLC I\/O, relay coils, indicator lamps) — always size the conductor to the connected load and the protective device rating, and check with your panel builder if unsure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this wire is sold per metre, so you can order any length you need rather than a fixed drum quantity. The listed price is per metre; set the quantity to the number of metres required at checkout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between Flexible Panel Wire and RR Kabel's Single-Core Building Wire?\u003c\/strong\u003e\u003cbr\u003eFlexible Panel Wire uses a fine, multi-strand copper conductor for routing inside control panels and enclosures where wires are frequently bent, formed, and ferruled. RR Kabel's Building Wire range uses a solid\/coarser-stranded conductor for fixed wall and conduit installation in general building wiring, and isn't designed for the tight bends and repeated flexing found inside a panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003ePanel and control wiring of this type is typically installed by a qualified panel builder or licensed electrician as part of a switchboard, DB, or control panel build, in line with UAE wiring practice — it isn't intended as a DIY connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy is the conductor fine-stranded instead of solid?\u003c\/strong\u003e\u003cbr\u003eFine stranding keeps the wire flexible enough to route through crowded panel enclosures and terminate onto ferrules, terminal blocks, and DIN-rail devices without work-hardening or cracking — something a solid conductor can't do reliably in this application.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Red","offer_id":44139278499939,"sku":"RR-S\/C-0.5MM-100Y-RED","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Yellow","offer_id":44124919562339,"sku":"RR-S\/C-0.5MM-100Y-YLW","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Blue","offer_id":44139278532707,"sku":"RR-S\/C-0.5MM-100Y-BL","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Black","offer_id":44124919529571,"sku":"RR-S\/C-0.5MM-100Y-BLK","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Yellow\/Green","offer_id":44139278565475,"sku":"RR-S\/C-0.5MM-100Y-YG","price":22.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/ChatGPT_Image_Apr_23_2026_10_14_03_PM.png?v=1786965932"},{"product_id":"rr-flexible-panel-wire-1-0mm-single-core","title":"RR Kabel 1.0mm² Single-Core Flexible Panel Wire","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Kabel 1.0mm² Single-Core Flexible Panel Wire\u003c\/h2\u003e\n\u003cp\u003eThe RR Flexible Panel Wire 1.0mm² Single Core is a fine-stranded, flexible conductor for internal wiring in switchgear, control panels, and distribution boards. Available in 5 colours. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1.0mm² fine-stranded conductor for flexible panel routing\u003c\/li\u003e\n\u003cli\u003e5 colours for circuit identification\u003c\/li\u003e\n\u003cli\u003ePVC insulation rated for panel wiring environments\u003c\/li\u003e\n\u003cli\u003eSold per metre\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCross-Section\u003c\/td\u003e\n\u003ctd\u003e1.0mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Type\u003c\/td\u003e\n\u003ctd\u003eFlexible (fine stranded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Colours\u003c\/td\u003e\n\u003ctd\u003eBlack, Red, Blue, Yellow, Yellow\/Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Standard\u003c\/td\u003e\n\u003ctd\u003eEN 50525-2-31 (H05V-K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Class\u003c\/td\u003e\n\u003ctd\u003eClass 5 flexible, per EN 60228\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistribution board and switchgear internal wiring\u003c\/li\u003e\n\u003cli\u003ePLC input\/output and signal wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 1.0mm² cross-section rating mean?\u003c\/strong\u003e\u003cbr\u003eThe cross-section is the copper conductor's area in square millimetres, which determines how much current it can safely carry. 1.0mm² suits control circuits and lightly-loaded auxiliary wiring within panels — always size the conductor to the connected load and the protective device rating, and check with your panel builder if unsure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this wire is sold per metre, so you can order any length you need rather than a fixed drum quantity. The listed price is per metre; set the quantity to the number of metres required at checkout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between Flexible Panel Wire and RR Kabel's Single-Core Building Wire?\u003c\/strong\u003e\u003cbr\u003eFlexible Panel Wire uses a fine, multi-strand copper conductor for routing inside control panels and enclosures where wires are frequently bent, formed, and ferruled. RR Kabel's Building Wire range uses a solid\/coarser-stranded conductor for fixed wall and conduit installation in general building wiring, and isn't designed for the tight bends and repeated flexing found inside a panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003ePanel and control wiring of this type is typically installed by a qualified panel builder or licensed electrician as part of a switchboard, DB, or control panel build, in line with UAE wiring practice — it isn't intended as a DIY connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy is the conductor fine-stranded instead of solid?\u003c\/strong\u003e\u003cbr\u003eFine stranding keeps the wire flexible enough to route through crowded panel enclosures and terminate onto ferrules, terminal blocks, and DIN-rail devices without work-hardening or cracking — something a solid conductor can't do reliably in this application.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Red","offer_id":44139275157603,"sku":"RR-S\/C-1MM-100YRED","price":20.0,"currency_code":"AED","in_stock":true},{"title":"Yellow","offer_id":44139275190371,"sku":"RR-S\/C-1MM-100Y-YLW","price":20.0,"currency_code":"AED","in_stock":true},{"title":"Blue","offer_id":44139275223139,"sku":"RR-S\/C-1MM-100Y-BL","price":20.0,"currency_code":"AED","in_stock":true},{"title":"Black","offer_id":44124919627875,"sku":"RR-S\/C-1MM-100Y-BLK","price":20.0,"currency_code":"AED","in_stock":true},{"title":"Yellow\/Green","offer_id":44139275255907,"sku":"RR-S\/C-1MM-100Y-YG","price":20.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/ChatGPT_Image_Apr_23_2026_10_14_03_PM.png?v=1786965932"},{"product_id":"rr-flexible-panel-wire-1-5mm-single-core","title":"RR Kabel 1.5mm² Single-Core Flexible Panel Wire","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Flexible Panel Wire 1.5mm² Single Core\u003c\/h2\u003e\n\u003cp\u003eThe RR Flexible Panel Wire 1.5mm² Single Core is the most widely used panel wire size for internal distribution board and control panel wiring across UAE commercial and industrial projects. Available in five colours — Black, Blue, Red, Yellow, and Yellow\/Green — it covers standard circuit colour-coding requirements in a single product range. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1.5mm² fine-stranded conductor for versatile panel wiring\u003c\/li\u003e\n\u003cli\u003eFive colours available for circuit colour-coding, including Yellow\/Green for earth\u003c\/li\u003e\n\u003cli\u003ePVC insulation rated for panel and switchgear environments\u003c\/li\u003e\n\u003cli\u003eFlexible stranding for ease of routing and termination\u003c\/li\u003e\n\u003cli\u003eSold per metre for precise project quantities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e1.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Type\u003c\/td\u003e\n\u003ctd\u003eFlexible (fine stranded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Colours\u003c\/td\u003e\n\u003ctd\u003eBlack, Blue, Red, Yellow, Yellow\/Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistribution board internal wiring\u003c\/li\u003e\n\u003cli\u003eMCC and switchgear panel wiring\u003c\/li\u003e\n\u003cli\u003eControl and relay panel circuit connections\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and PLC panel wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 1.5mm² cross-section rating mean, and is it the right size?\u003c\/strong\u003e\u003cbr\u003eThe cross-section is the copper conductor's area in square millimetres, which determines how much current it can safely carry. 1.5mm² is one of the most common panel wiring sizes, suited to general control and DB internal wiring circuits — always size the conductor to the connected load and the protective device rating, and check with your panel builder if unsure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this wire is sold per metre, so you can order any length you need rather than a fixed drum quantity. The listed price is per metre; set the quantity to the number of metres required at checkout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between Flexible Panel Wire and RR Kabel's Single-Core Building Wire?\u003c\/strong\u003e\u003cbr\u003eFlexible Panel Wire uses a fine, multi-strand copper conductor for routing inside control panels and enclosures where wires are frequently bent, formed, and ferruled. RR Kabel's Building Wire range uses a solid\/coarser-stranded conductor for fixed wall and conduit installation in general building wiring, and isn't designed for the tight bends and repeated flexing found inside a panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003ePanel and control wiring of this type is typically installed by a qualified panel builder or licensed electrician as part of a switchboard, DB, or control panel build, in line with UAE wiring practice — it isn't intended as a DIY connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy does the Yellow\/Green colour matter?\u003c\/strong\u003e\u003cbr\u003eYellow\/Green striped insulation is the internationally recognised colour code for protective earth (PE) conductors. Using the dedicated Yellow\/Green variant for earth\/bonding connections — rather than a generic colour — keeps panel wiring compliant with standard colour-coding practice and easy to identify during maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Red","offer_id":44124919758947,"sku":"RR-S\/C-1.5MM-100YRED","price":22.0,"currency_code":"AED","in_stock":true},{"title":"Yellow","offer_id":44124919791715,"sku":"RR-FPW-1.5-YEL","price":22.0,"currency_code":"AED","in_stock":true},{"title":"Blue","offer_id":44124919726179,"sku":"RR-S\/C-1.5MM-100YBLUE","price":22.0,"currency_code":"AED","in_stock":true},{"title":"Black","offer_id":44124919693411,"sku":"RR-FPW-1.5-BLK","price":22.0,"currency_code":"AED","in_stock":true},{"title":"Yellow\/Green","offer_id":44139273846883,"sku":"RR-FPW-1.5-YG","price":22.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/ChatGPT_Image_Apr_23_2026_10_14_03_PM.png?v=1786965932"},{"product_id":"rr-flexible-panel-wire-10mm-single-core","title":"RR Kabel 10mm² Single-Core Flexible Panel Wire","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Flexible Panel Wire 10mm² Single Core\u003c\/h2\u003e\n\u003cp\u003eThe RR Flexible Panel Wire 10mm² Single Core is a large-section flexible conductor for high-current main connections, busbar links, and heavy power wiring inside large industrial panels and MCCs. Its fine-stranded 10mm² conductor provides the combination of current capacity and flexibility required for demanding UAE industrial panel installations. Available in Black, Blue, Red, Yellow, and Yellow\/Green. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e10mm² fine-stranded conductor for heavy panel power connections\u003c\/li\u003e\n\u003cli\u003eHigh current-carrying capacity for main panel distribution\u003c\/li\u003e\n\u003cli\u003eFine stranding for flexibility despite large cross-section\u003c\/li\u003e\n\u003cli\u003ePVC insulation for panel and enclosure environments\u003c\/li\u003e\n\u003cli\u003eSold per metre for precise project ordering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e10mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Type\u003c\/td\u003e\n\u003ctd\u003eFlexible (fine stranded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Colours\u003c\/td\u003e\n\u003ctd\u003eBlack, Blue, Red, Yellow, Yellow\/Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain incomer and sub-main panel connections\u003c\/li\u003e\n\u003cli\u003eLarge MCC and switchgear busbar links\u003c\/li\u003e\n\u003cli\u003eIndustrial motor feeder connections within panels\u003c\/li\u003e\n\u003cli\u003eHigh-current earth bonding inside large enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10mm² cross-section rating mean, and is it the right size?\u003c\/strong\u003e\u003cbr\u003eThe cross-section is the copper conductor's area in square millimetres, which determines how much current it can safely carry. 10mm² suits high-current main connections and busbar links in industrial panels and MCCs — always size the conductor to the connected load and the protective device rating, and confirm with your panel builder or electrical engineer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this wire is sold per metre, so you can order any length you need rather than a fixed drum quantity. The listed price is per metre; set the quantity to the number of metres required at checkout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between Flexible Panel Wire and RR Kabel's Single-Core Building Wire?\u003c\/strong\u003e\u003cbr\u003eFlexible Panel Wire uses a fine, multi-strand copper conductor for routing inside control panels and enclosures where wires are frequently bent, formed, and ferruled. RR Kabel's Building Wire range uses a solid\/coarser-stranded conductor for fixed wall and conduit installation in general building wiring, and isn't designed for the tight bends and repeated flexing found inside a panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003ePanel and control wiring of this type — especially at this current-carrying size — is installed by a qualified panel builder or licensed electrician as part of a switchboard, MCC, or control panel build, in line with UAE wiring practice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy is fine-stranded construction used at a large cross-section like 10mm²?\u003c\/strong\u003e\u003cbr\u003eFine stranding keeps even a large-section conductor flexible enough to route and bend through crowded panel enclosures and terminate onto lugs or busbars — a solid conductor at this size would be far too stiff to work with inside a panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Red","offer_id":44139270930531,"sku":"RR-FPW-10-RED","price":20.0,"currency_code":"AED","in_stock":true},{"title":"Yellow","offer_id":44139270963299,"sku":"RR-FPW-10-YLW","price":20.0,"currency_code":"AED","in_stock":true},{"title":"Blue","offer_id":44139270996067,"sku":"RR-FPW-10-BL","price":20.0,"currency_code":"AED","in_stock":true},{"title":"Black","offer_id":44139271028835,"sku":"RR-FPW-10-BLK","price":20.0,"currency_code":"AED","in_stock":true},{"title":"Yellow\/Green","offer_id":44139271061603,"sku":"RR-FPW-10-YG","price":20.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/ChatGPT_Image_Apr_23_2026_10_14_03_PM.png?v=1786965932"},{"product_id":"rr-flexible-panel-wire-2-5mm-single-core","title":"RR Kabel 2.5mm² Single-Core Flexible Panel Wire","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Flexible Panel Wire 2.5mm² Single Core\u003c\/h2\u003e\n\u003cp\u003eThe RR Flexible Panel Wire 2.5mm² Single Core is a versatile, finely stranded conductor for power connections and control wiring inside distribution boards, MCCs, and industrial panels. Available in Black, Blue, Red, Yellow, and Yellow\/Green, it covers all standard circuit colour-coding requirements for UAE panel builders and contractors. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2.5mm² fine-stranded conductor for power and control panel wiring\u003c\/li\u003e\n\u003cli\u003eAvailable in Black, Blue, Red, Yellow, and Yellow\/Green\u003c\/li\u003e\n\u003cli\u003ePVC insulation for standard panel wiring environments\u003c\/li\u003e\n\u003cli\u003eFlexible stranding for easy routing and crimped termination\u003c\/li\u003e\n\u003cli\u003eSold per metre for accurate panel build quantities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e2.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Type\u003c\/td\u003e\n\u003ctd\u003eFlexible (fine stranded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Colours\u003c\/td\u003e\n\u003ctd\u003eBlack, Blue, Red, Yellow, Yellow\/Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMCC and power distribution panel wiring\u003c\/li\u003e\n\u003cli\u003eDistribution board busbar connections\u003c\/li\u003e\n\u003cli\u003eIndustrial control and automation panel builds\u003c\/li\u003e\n\u003cli\u003eEarth bonding connections within panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 2.5mm² cross-section rating mean, and is it the right size?\u003c\/strong\u003e\u003cbr\u003eThe cross-section is the copper conductor's area in square millimetres, which determines how much current it can safely carry. 2.5mm² suits power and control wiring carrying moderate load current inside panels and DBs — always size the conductor to the connected load and the protective device rating, and check with your panel builder if unsure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this wire is sold per metre, so you can order any length you need rather than a fixed drum quantity. The listed price is per metre; set the quantity to the number of metres required at checkout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between Flexible Panel Wire and RR Kabel's Single-Core Building Wire?\u003c\/strong\u003e\u003cbr\u003eFlexible Panel Wire uses a fine, multi-strand copper conductor for routing inside control panels and enclosures where wires are frequently bent, formed, and ferruled. RR Kabel's Building Wire range uses a solid\/coarser-stranded conductor for fixed wall and conduit installation in general building wiring, and isn't designed for the tight bends and repeated flexing found inside a panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003ePanel and control wiring of this type is typically installed by a qualified panel builder or licensed electrician as part of a switchboard, DB, or control panel build, in line with UAE wiring practice — it isn't intended as a DIY connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy does the Yellow\/Green colour matter?\u003c\/strong\u003e\u003cbr\u003eYellow\/Green striped insulation is the internationally recognised colour code for protective earth (PE) conductors. Using the dedicated Yellow\/Green variant for earth\/bonding connections keeps panel wiring compliant with standard colour-coding practice and easy to identify during maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Red","offer_id":44124920053859,"sku":"RR-S\/C-2.5MM-100-RED","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Yellow","offer_id":44138899800163,"sku":"RR-S\/C-2.5MM-100-YLW","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Blue","offer_id":44124920021091,"sku":"RR-S\/C-2.5MM-100-BLUE","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Black","offer_id":44124919988323,"sku":"RR-S\/C-2.5MM-100-BLK","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Yellow\/Green","offer_id":44124920086627,"sku":"RR-S\/C-2.5MM-100-YG","price":21.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/ChatGPT_Image_Apr_23_2026_10_14_03_PM.png?v=1786965932"},{"product_id":"rr-flexible-panel-wire-4-0mm-single-core","title":"RR Kabel 4.0mm² Single-Core Flexible Panel Wire","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Flexible Panel Wire 4.0mm² Single Core\u003c\/h2\u003e\n\u003cp\u003eThe RR Flexible Panel Wire 4.0mm² Single Core is a heavy-duty flexible conductor for high-current connections inside MCCs, power distribution panels, and industrial control enclosures. Available in five colours — Black, Blue, Red, Yellow, and Yellow\/Green — it provides full colour-coded wiring for three-phase and earth connections in UAE industrial panel builds. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4.0mm² fine-stranded conductor for high-current panel connections\u003c\/li\u003e\n\u003cli\u003eFive colours available for complete three-phase and earth identification\u003c\/li\u003e\n\u003cli\u003ePVC insulation for standard panel environments\u003c\/li\u003e\n\u003cli\u003eFlexible construction for routing within large panel enclosures\u003c\/li\u003e\n\u003cli\u003eSold per metre for exact project quantities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e4.0mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Type\u003c\/td\u003e\n\u003ctd\u003eFlexible (fine stranded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Colours\u003c\/td\u003e\n\u003ctd\u003eBlack, Blue, Red, Yellow, Yellow\/Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMCC busbar and incomer connections\u003c\/li\u003e\n\u003cli\u003eHigh-current power distribution panel wiring\u003c\/li\u003e\n\u003cli\u003eIndustrial drive and motor control panel builds\u003c\/li\u003e\n\u003cli\u003eMain earth bonding within large panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 4.0mm² cross-section rating mean, and is it the right size?\u003c\/strong\u003e\u003cbr\u003eThe cross-section is the copper conductor's area in square millimetres, which determines how much current it can safely carry. 4.0mm² suits higher-current power connections such as MCC feeders and three-phase\/earth wiring within panels — always size the conductor to the connected load and the protective device rating, and check with your panel builder if unsure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this wire is sold per metre, so you can order any length you need rather than a fixed drum quantity. The listed price is per metre; set the quantity to the number of metres required at checkout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between Flexible Panel Wire and RR Kabel's Single-Core Building Wire?\u003c\/strong\u003e\u003cbr\u003eFlexible Panel Wire uses a fine, multi-strand copper conductor for routing inside control panels and enclosures where wires are frequently bent, formed, and ferruled. RR Kabel's Building Wire range uses a solid\/coarser-stranded conductor for fixed wall and conduit installation in general building wiring, and isn't designed for the tight bends and repeated flexing found inside a panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003ePanel and control wiring of this type is typically installed by a qualified panel builder or licensed electrician as part of a switchboard, MCC, or control panel build, in line with UAE wiring practice — it isn't intended as a DIY connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy is fine-stranded construction used instead of solid at 4.0mm²?\u003c\/strong\u003e\u003cbr\u003eFine stranding keeps the conductor flexible enough to route and bend through crowded panel enclosures and terminate onto ferrules or lugs — a solid conductor at this size would be far stiffer and harder to route cleanly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Red","offer_id":44124920348771,"sku":"RR-FPW-4.0-RED","price":18.0,"currency_code":"AED","in_stock":true},{"title":"Yellow","offer_id":44124920381539,"sku":"RR-FPW-4.0-YEL","price":18.0,"currency_code":"AED","in_stock":true},{"title":"Blue","offer_id":44124920316003,"sku":"RR-FPW-4.0-BLU","price":18.0,"currency_code":"AED","in_stock":true},{"title":"Black","offer_id":44124920283235,"sku":"RR-FPW-4.0-BLK","price":18.0,"currency_code":"AED","in_stock":true},{"title":"Yellow\/Green","offer_id":44124920414307,"sku":"RR-FPW-4.0-YG","price":21.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/ChatGPT_Image_Apr_23_2026_10_14_03_PM.png?v=1786965932"},{"product_id":"rr-flexible-panel-wire-6-0mm-single-core","title":"RR Kabel 6.0mm² Single-Core Flexible Panel Wire","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Flexible Panel Wire 6.0mm² Single Core\u003c\/h2\u003e\n\u003cp\u003eThe RR Flexible Panel Wire 6.0mm² Single Core is a high-current flexible conductor for main busbar connections, incomer wiring, and large power circuit terminations inside industrial panels and MCCs. Its fine-stranded construction allows routing through large enclosures with ease. Available in Black, Blue, Red, Yellow, and Yellow\/Green. Sold per metre for accurate panel build ordering across UAE projects.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e6.0mm² fine-stranded conductor for heavy panel power connections\u003c\/li\u003e\n\u003cli\u003eHigh current capacity for incomer and main distribution wiring\u003c\/li\u003e\n\u003cli\u003ePVC insulation for panel and enclosure environments\u003c\/li\u003e\n\u003cli\u003eFlexible stranding for routing in large industrial enclosures\u003c\/li\u003e\n\u003cli\u003eSold per metre for precise ordering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e6.0mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Type\u003c\/td\u003e\n\u003ctd\u003eFlexible (fine stranded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Colours\u003c\/td\u003e\n\u003ctd\u003eBlack, Blue, Red, Yellow, Yellow\/Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain incomer and busbar connections in large panels\u003c\/li\u003e\n\u003cli\u003eMCC and switchgear high-current internal connections\u003c\/li\u003e\n\u003cli\u003eIndustrial motor and drive panel wiring\u003c\/li\u003e\n\u003cli\u003eMain earth bonding within large enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6.0mm² cross-section rating mean, and is it the right size?\u003c\/strong\u003e\u003cbr\u003eThe cross-section is the copper conductor's area in square millimetres, which determines how much current it can safely carry. 6.0mm² suits heavier power connections such as incomer wiring and busbar links inside larger panels — always size the conductor to the connected load and the protective device rating, and confirm with your panel builder or electrical engineer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this wire is sold per metre, so you can order any length you need rather than a fixed drum quantity. The listed price is per metre; set the quantity to the number of metres required at checkout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between Flexible Panel Wire and RR Kabel's Single-Core Building Wire?\u003c\/strong\u003e\u003cbr\u003eFlexible Panel Wire uses a fine, multi-strand copper conductor for routing inside control panels and enclosures where wires are frequently bent, formed, and ferruled. RR Kabel's Building Wire range uses a solid\/coarser-stranded conductor for fixed wall and conduit installation in general building wiring, and isn't designed for the tight bends and repeated flexing found inside a panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003ePanel and control wiring of this type — especially at this current-carrying size — is installed by a qualified panel builder or licensed electrician as part of a switchboard, MCC, or control panel build, in line with UAE wiring practice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy is fine-stranded construction used at a large cross-section like 6.0mm²?\u003c\/strong\u003e\u003cbr\u003eFine stranding keeps even a large-section conductor flexible enough to route and bend through crowded panel enclosures and terminate onto lugs or busbars — a solid conductor at this size would be far too stiff to work with inside a panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Red","offer_id":44137223553123,"sku":"RR-FPW-6.0-RED","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Yellow","offer_id":44137223585891,"sku":"RR-FPW-6.0-YEL","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Blue","offer_id":44137223618659,"sku":"RR-FPW-6.0-BL","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Black","offer_id":44137223651427,"sku":"RR-FPW-6.0-BLK","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Yellow\/Green","offer_id":44137223684195,"sku":"RR-FPW-6.0-Y\/G","price":21.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/ChatGPT_Image_Apr_23_2026_10_14_03_PM.png?v=1786965932"},{"product_id":"rr-panel-wire-35mm-single-core","title":"RR Kabel 35mm² Single-Core Flexible Panel Wire","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Panel Wire 35mm² Single Core\u003c\/h2\u003e\n\u003cp\u003eThe RR Panel Wire 35mm² Single Core is a very large-section flexible conductor for main incomer connections, high-capacity busbar links, and heavy distribution wiring inside large industrial switchgear and MCCs. It provides the current capacity and flexibility required for the heaviest panel power connections in UAE industrial and commercial installations. Available in Black, Blue, Red, Yellow, and Yellow\/Green. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e35mm² stranded conductor for main incomer and busbar connections\u003c\/li\u003e\n\u003cli\u003eVery high current capacity for heavy panel power wiring\u003c\/li\u003e\n\u003cli\u003eStranded construction for manageable flexibility at large cross-section\u003c\/li\u003e\n\u003cli\u003ePVC insulation for panel and enclosure environments\u003c\/li\u003e\n\u003cli\u003eSold per metre for large-project quantities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e35mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Type\u003c\/td\u003e\n\u003ctd\u003eStranded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Colours\u003c\/td\u003e\n\u003ctd\u003eBlack, Blue, Red, Yellow, Yellow\/Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain incomer connections in large MCCs and switchgear\u003c\/li\u003e\n\u003cli\u003eHigh-capacity busbar links and distribution connections\u003c\/li\u003e\n\u003cli\u003eIndustrial plant main power wiring within panels\u003c\/li\u003e\n\u003cli\u003eLarge commercial building main distribution board connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 35mm² cross-section rating mean, and is it the right size?\u003c\/strong\u003e\u003cbr\u003eThe cross-section is the copper conductor's area in square millimetres, which determines how much current it can safely carry. 35mm² is a large cross-section suited to main incomer connections and high-capacity busbar links in large MCCs and switchgear — always size the conductor to the connected load and the protective device rating, and confirm with your panel builder or electrical engineer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this wire is sold per metre, so you can order any length you need rather than a fixed drum quantity. The listed price is per metre; set the quantity to the number of metres required at checkout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between Panel Wire and RR Kabel's Single-Core Building Wire?\u003c\/strong\u003e\u003cbr\u003ePanel Wire at this size uses a stranded copper conductor sized for high-current main connections and busbar links inside large panels and switchgear. RR Kabel's Building Wire range is designed for fixed wall\/conduit installation in general building wiring rather than for termination onto busbars and heavy-duty lugs inside a panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eMain incomer and busbar-level panel wiring at this size is installed by a qualified panel builder or licensed electrician as part of a switchboard or MCC build, in line with UAE wiring practice — not a DIY connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy is stranded construction used at a large cross-section like 35mm²?\u003c\/strong\u003e\u003cbr\u003eStranding keeps a large-section conductor manageable enough to route, bend, and terminate onto lugs and busbars inside a panel — a solid conductor at this size would be extremely stiff and impractical to install.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Red","offer_id":44137217163363,"sku":"RR-PW-35-RED","price":38.0,"currency_code":"AED","in_stock":true},{"title":"Yellow","offer_id":44137217196131,"sku":"RR-PW-35-YLW","price":38.0,"currency_code":"AED","in_stock":true},{"title":"Blue","offer_id":44137217228899,"sku":"RR-PW-35-BL","price":38.0,"currency_code":"AED","in_stock":true},{"title":"Black","offer_id":44137217261667,"sku":"RR-PW-35-BLK","price":38.0,"currency_code":"AED","in_stock":true},{"title":"Yellow\/Green","offer_id":44137224372323,"sku":null,"price":42.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/ChatGPT_Image_Apr_23_2026_10_14_03_PM.png?v=1786965932"},{"product_id":"rr-solid-wire-0-75mm-single-core-105-c","title":"RR Kabel 0.75mm² Single-Core Solid Wire 105°C","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Solid Wire 0.75mm² Single Core 105°C\u003c\/h2\u003e\n\u003cp\u003eThe RR Solid Wire 0.75mm² Single Core 105°C is a heat-rated solid conductor for internal panel wiring, instrument connections, and light control circuits where elevated operating temperatures are expected. Its 105°C rating makes it suitable for switchgear and control panel environments across UAE commercial and industrial installations.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e0.75mm² solid conductor for compact panel and instrument wiring\u003c\/li\u003e\n\u003cli\u003e105°C temperature rating for high-ambient panel environments\u003c\/li\u003e\n\u003cli\u003ePVC insulation for reliable performance in enclosed panels\u003c\/li\u003e\n\u003cli\u003eSold per metre for precise ordering\u003c\/li\u003e\n\u003cli\u003eGenuine RR Cables quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e0.75mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Type\u003c\/td\u003e\n\u003ctd\u003eSolid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Rating\u003c\/td\u003e\n\u003ctd\u003e105°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInternal switchgear and distribution board wiring\u003c\/li\u003e\n\u003cli\u003eInstrument and control panel connections\u003c\/li\u003e\n\u003cli\u003eLow-voltage control circuits in industrial panels\u003c\/li\u003e\n\u003cli\u003eEquipment interconnection in high-ambient enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 0.75mm² cross-section mean, and is it enough for my circuit?\u003c\/strong\u003e\u003cbr\u003e0.75mm² is a small conductor sized for low-current control, instrument, and internal panel wiring — not for general power circuits. It's intended for switchgear\/control-panel interconnections and instrument loops, not for supplying sockets or appliances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this wire is sold per metre, so you enter the exact quantity of metres you need at checkout and are charged accordingly. There's no minimum roll or coil requirement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this 105°C Solid Wire and RR Kabel's standard Single-Core Building Wire?\u003c\/strong\u003e\u003cbr\u003eStandard Single-Core Building Wire is PVC-insulated for general fixed wiring in walls, conduit, and trunking, rated to around 70°C. This 105°C solid wire uses a higher-temperature-rated insulation intended for internal switchgear and control-panel wiring, where ambient temperatures inside an enclosure can run significantly hotter than open building wiring. Use the 105°C wire for panel\/instrument interconnections, not as a substitute for general circuit wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eYes — this is typically installed by a qualified panel builder or licensed electrician as part of a switchgear or control panel build, not a DIY wiring product.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy are different colours (Red\/White\/Black) used, and can I mix colours in one order?\u003c\/strong\u003e\u003cbr\u003eColour-coding inside a panel helps an electrician trace individual control\/instrument circuits during wiring and later maintenance. You can order any mix of colours and lengths in the same purchase — each colour is a separate variant of the same 0.75mm² wire.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Red","offer_id":44136491057251,"sku":"RR-SW-0.75-RED-1","price":18.0,"currency_code":"AED","in_stock":true},{"title":"White","offer_id":44136491090019,"sku":"RR-SW-0.75-WHI-2","price":18.0,"currency_code":"AED","in_stock":true},{"title":"Black","offer_id":44136491122787,"sku":"RR-SW-0.75-BLK-3","price":18.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/images.jpg?v=1786966048"},{"product_id":"rr-pvc-flexible-cable-0-75mm-2-core","title":"RR Kabel 0.75mm² 2-Core PVC Flexible Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR PVC Flexible Cable 0.75mm² 2-Core\u003c\/h2\u003e\n\u003cp\u003eThe RR PVC Flexible Cable 0.75mm² 2-Core is a light-duty flexible cable for portable appliances, lamp connections, and low-current two-wire circuits. Its fine-stranded construction provides the flexibility needed for moveable equipment and pendant lighting in UAE residential, hospitality, and commercial environments. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e0.75mm² fine-stranded 2-core construction for light flexible applications\u003c\/li\u003e\n\u003cli\u003ePVC insulation and sheath for durability in light-duty use\u003c\/li\u003e\n\u003cli\u003eFlexible construction for pendants, lamps, and portable devices\u003c\/li\u003e\n\u003cli\u003eSuitable for 220–240V AC supply applications\u003c\/li\u003e\n\u003cli\u003eSold per metre for precise ordering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e0.75mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eBare copper, fine-wire flexible stranding (Class 5, EN 60228)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6500 \/ equivalent BS EN 50525-2-11 (H05VV-F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5°C to +70°C (flexing); up to +70°C fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePendant lamp and chandelier flex connections\u003c\/li\u003e\n\u003cli\u003eLight portable appliances and table lamps\u003c\/li\u003e\n\u003cli\u003eLow-current two-wire equipment connections\u003c\/li\u003e\n\u003cli\u003eResidential and hospitality lighting installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 0.75mm² cross-section rating mean, and is it right for my circuit?\u003c\/strong\u003e\u003cbr\u003e0.75mm² is the copper conductor's cross-sectional area, which determines its safe current-carrying capacity. This size suits light loads such as pendant lamps, low-wattage fixtures, and small portable devices — for higher-current appliances (heaters, fans, power tools) step up to 1.5mm² or 2.5mm². If you're unsure of the load, check with a qualified electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this cable is sold per metre, so you order the exact length you need and are charged at the per-metre rate. There's no fixed roll minimum, though we can also supply full coils for larger projects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this and RR Kabel's single-core Building Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire is a solid or semi-flexible single conductor designed for fixed installation inside conduit or trunking. This PVC Flexible Cable is a fine-stranded, genuinely flexible 2-core cable meant for connections that move or need to be routed to portable\/moveable equipment, such as lamp flex or appliance leads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs a 2-core (no earth) cable safe for all appliances?\u003c\/strong\u003e\u003cbr\u003eA 2-core cable has no protective earth conductor, so it's suitable only for double-insulated (Class II) appliances and fittings that don't require earthing. If your equipment has an earth terminal or metal casing requiring a safety earth, use the 3-core version instead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eFinal connections into fixed lighting circuits, junction boxes, or permanent fittings should be made by a licensed electrician in line with UAE wiring regulations. This product is intended for trade and contractor use, not DIY household wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44127529631843,"sku":"RR-PFC-0.75-2C-WHT","price":17.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/2c2.avif?v=1786966054"},{"product_id":"rr-pvc-flexible-cable-1-0mm-2-core","title":"RR Kabel 1.0mm² 2-Core PVC Flexible Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR PVC Flexible Cable 1.0mm² 2-Core\u003c\/h2\u003e\n\u003cp\u003eThe RR PVC Flexible Cable 1.0mm² 2-Core is a general-purpose flexible cable for portable equipment, extension connections, and two-wire appliance leads across UAE residential and commercial applications. Its 1.0mm² conductor offers greater current capacity than 0.75mm² flex, making it suitable for heavier portable loads. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1.0mm² fine-stranded 2-core for portable equipment connections\u003c\/li\u003e\n\u003cli\u003eHigher current capacity than 0.75mm² equivalent flex\u003c\/li\u003e\n\u003cli\u003ePVC insulation and sheath for robust everyday use\u003c\/li\u003e\n\u003cli\u003eFlexible construction suitable for moveable appliances\u003c\/li\u003e\n\u003cli\u003eSold per metre for exact quantity ordering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e1.0mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eBare copper, fine-wire flexible stranding (Class 5, EN 60228)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6500 \/ equivalent BS EN 50525-2-11 (H05VV-F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5°C to +70°C (flexing); up to +70°C fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePortable appliance and equipment connections\u003c\/li\u003e\n\u003cli\u003eExtension lead construction and repair\u003c\/li\u003e\n\u003cli\u003eTwo-wire domestic and commercial equipment leads\u003c\/li\u003e\n\u003cli\u003eLight power tool and device connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 1.0mm² cross-section rating mean, and how do I pick the right size?\u003c\/strong\u003e\u003cbr\u003e1.0mm² refers to the copper conductor's cross-sectional area, which sets its current-carrying capacity — this size handles moderate portable loads better than 0.75mm² flex. For heavier appliances like heaters or power tools, 1.5mm² or 2.5mm² is usually the better choice. Check the appliance's rated current or ask an electrician if unsure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this cable is sold per metre at a fixed per-metre rate, so you only pay for the length you need. No roll minimum applies, and full coils are available for bulk project orders.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this and RR Kabel's single-core Building Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire is a solid single conductor for fixed installation in conduit or trunking. This 2-core PVC Flexible Cable is fine-stranded for genuine flexibility, designed for connections to portable or moveable equipment rather than permanent building circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs a 2-core (no earth) cable suitable for my appliance?\u003c\/strong\u003e\u003cbr\u003e2-core cable carries no protective earth, so it's intended for double-insulated (Class II) equipment only. Appliances requiring an earth connection need the 3-core version.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eConnections into fixed circuits, distribution points, or permanent fittings should be carried out by a licensed electrician per UAE wiring regulations. This is a trade\/contractor-supply product, not intended for DIY household wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44127529893987,"sku":"RR-PFC-1.0-2C-WHT","price":18.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/2c2.avif?v=1786966054"},{"product_id":"rr-pvc-flexible-cable-1-0mm-3-core","title":"RR Kabel 1.0mm² 3-Core PVC Flexible Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR PVC Flexible Cable 1.0mm² 3-Core\u003c\/h2\u003e\n\u003cp\u003eThe RR PVC Flexible Cable 1.0mm² 3-Core is a standard three-wire flexible cable for earthed portable appliances, power tools, and equipment connections requiring a protective earth conductor. Its fine-stranded construction provides the flexibility required for regularly moved equipment in UAE residential, commercial, and light industrial environments. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1.0mm² fine-stranded 3-core with earth conductor included\u003c\/li\u003e\n\u003cli\u003eSuitable for Class I (earthed) portable appliances and tools\u003c\/li\u003e\n\u003cli\u003ePVC insulation and sheath for robust everyday performance\u003c\/li\u003e\n\u003cli\u003eFlexible construction for moveable equipment connections\u003c\/li\u003e\n\u003cli\u003eSold per metre for accurate ordering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e1.0mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eBare copper, fine-wire flexible stranding (Class 5, EN 60228)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6500 \/ equivalent BS EN 50525-2-11 (H05VV-F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5°C to +70°C (flexing); up to +70°C fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEarthed portable appliance and power tool connections\u003c\/li\u003e\n\u003cli\u003eDomestic and commercial equipment leads with earth\u003c\/li\u003e\n\u003cli\u003eExtension lead and distribution board flex\u003c\/li\u003e\n\u003cli\u003eLight-duty three-wire equipment connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 1.0mm² cross-section rating mean, and how do I pick the right size?\u003c\/strong\u003e\u003cbr\u003e1.0mm² is the copper conductor's cross-sectional area, which determines how much current it can safely carry. This size suits light-to-moderate earthed loads; for higher-current tools and appliances, 1.5mm² or 2.5mm² 3-core is usually more appropriate. Check the appliance rating or ask an electrician if unsure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — sold per metre at a fixed per-metre rate, so you pay only for the length required. No roll minimum, and full coils are available for larger orders.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this and RR Kabel's single-core Building Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire is a solid single conductor for fixed wiring in conduit. This 3-core PVC Flexible Cable is fine-stranded for real flexibility and includes its own earth core, designed for connecting portable or moveable equipment rather than permanent circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy does this have 3 cores instead of 2?\u003c\/strong\u003e\u003cbr\u003eThe third core is a protective earth conductor, required for Class I appliances and power tools with exposed metal parts. If your equipment is double-insulated (Class II) and doesn't need an earth, the 2-core version is sufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eConnections into fixed circuits, distribution boards, or permanent equipment should be made by a licensed electrician per UAE wiring regulations. This is a trade\/contractor-supply product, not intended for DIY household wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44127529926755,"sku":"RR-FLX-3C1MM-WHITE-100Y","price":19.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_e65289d5-150a-4318-9681-6f517e4a11f0.png?v=1786966062"},{"product_id":"rr-pvc-flexible-cable-1-5mm-2-core","title":"RR Kabel 1.5mm² 2-Core PVC Flexible Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR PVC Flexible Cable 1.5mm² 2-Core\u003c\/h2\u003e\n\u003cp\u003eThe RR PVC Flexible Cable 1.5mm² 2-Core is a versatile two-wire flexible cable for portable heaters, fans, and higher-current appliances requiring a non-earthed connection. Its 1.5mm² conductor handles currents up to 16A, making it suitable for a wide range of UAE residential and commercial portable equipment applications. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1.5mm² fine-stranded 2-core for higher-current portable applications\u003c\/li\u003e\n\u003cli\u003eUp to 16A current capacity for heaters and fans\u003c\/li\u003e\n\u003cli\u003ePVC insulation and sheath for robust everyday durability\u003c\/li\u003e\n\u003cli\u003eFine-stranded conductor for flexible, easy-routing connections\u003c\/li\u003e\n\u003cli\u003eSold per metre for precise quantities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e1.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eBare copper, fine-wire flexible stranding (Class 5, EN 60228)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6500 \/ equivalent BS EN 50525-2-11 (H05VV-F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5°C to +70°C (flexing); up to +70°C fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePortable heaters, fans, and air coolers\u003c\/li\u003e\n\u003cli\u003eTwo-wire higher-current appliance connections\u003c\/li\u003e\n\u003cli\u003eCommercial and residential equipment leads\u003c\/li\u003e\n\u003cli\u003eExtension lead construction for higher-load devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 1.5mm² cross-section rating mean, and is it right for my load?\u003c\/strong\u003e\u003cbr\u003e1.5mm² is the copper conductor's cross-sectional area, giving this cable a safe current capacity of up to around 16A — enough for most portable heaters, fans, and general appliances. For heavier loads (power tools, industrial equipment) step up to 2.5mm². Confirm the appliance's rated current or check with an electrician if unsure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — sold per metre at a fixed per-metre rate, so you order and pay for exactly the length you need. No roll minimum, and full coils are available for bulk project orders.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this and RR Kabel's single-core Building Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire is a solid single conductor intended for fixed installation in conduit or trunking. This 2-core PVC Flexible Cable is fine-stranded for genuine flexibility, built for connecting portable or moveable equipment rather than permanent circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs a 2-core (no earth) cable safe for my appliance?\u003c\/strong\u003e\u003cbr\u003e2-core cable has no protective earth conductor, so it's suitable only for double-insulated (Class II) appliances. If your equipment needs an earth connection, use the 3-core 1.5mm² version instead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eConnections into fixed circuits, sockets, or permanent equipment should be made by a licensed electrician per UAE wiring regulations. This is a trade\/contractor-supply product, not intended for DIY household wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44127530057827,"sku":"RR-PFC-1.5-2C-NAT","price":19.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/2c2.avif?v=1786966054"},{"product_id":"rr-pvc-flexible-cable-1-5mm-3-core","title":"RR Kabel 1.5mm² 3-Core PVC Flexible Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR PVC Flexible Cable 1.5mm² 3-Core\u003c\/h2\u003e\n\u003cp\u003eThe RR PVC Flexible Cable 1.5mm² 3-Core is the most commonly used flexible cable for earthed portable appliances, power tools, and general-purpose equipment leads in UAE homes, offices, and commercial properties. Available in Black and White, it provides the flexibility and current capacity needed for reliable everyday connections. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1.5mm² fine-stranded 3-core with protective earth conductor\u003c\/li\u003e\n\u003cli\u003eAvailable in Black and White for easy identification\u003c\/li\u003e\n\u003cli\u003eHandles up to 16A for a wide range of appliances\u003c\/li\u003e\n\u003cli\u003ePVC insulation and sheath for durable everyday performance\u003c\/li\u003e\n\u003cli\u003eSold per metre — no roll minimum required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e1.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eBare copper, fine-wire flexible stranding (Class 5, EN 60228)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6500 \/ equivalent BS EN 50525-2-11 (H05VV-F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5°C to +70°C (flexing); up to +70°C fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Colours\u003c\/td\u003e\n\u003ctd\u003eBlack, White\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePortable appliances and power tool leads\u003c\/li\u003e\n\u003cli\u003eDomestic and commercial equipment with protective earth\u003c\/li\u003e\n\u003cli\u003eExtension lead construction and repair\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose three-wire flexible connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 1.5mm² cross-section rating mean, and is it right for my load?\u003c\/strong\u003e\u003cbr\u003e1.5mm² is the copper conductor's cross-sectional area, giving this cable a safe current capacity of up to around 16A — suitable for most earthed portable appliances and power tools. For heavier industrial loads, step up to 2.5mm² 3-core. Check the appliance's rated current or ask an electrician if unsure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — sold per metre at a fixed per-metre rate, so you pay only for the length required. No roll minimum, and full coils are available for larger orders.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs there any difference between the Black and White versions besides colour?\u003c\/strong\u003e\u003cbr\u003eNo — both are the same 1.5mm² 3-core PVC flexible cable built to the same specification. The colour is purely for identification or aesthetic matching (e.g. site colour-coding or matching appliance casing), so choose whichever suits your installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this and RR Kabel's single-core Building Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire is a solid single conductor for fixed installation in conduit. This 3-core PVC Flexible Cable is fine-stranded for real flexibility and includes its own earth core, built for connecting portable or moveable equipment rather than permanent building circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eConnections into fixed circuits, sockets, or permanent equipment should be made by a licensed electrician per UAE wiring regulations. This is a trade\/contractor-supply product, not intended for DIY household wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"RRKabel","offers":[{"title":"Black","offer_id":44127530090595,"sku":"RR-FLX-CAB-BLK-1.5MMX3C","price":18.0,"currency_code":"AED","in_stock":true},{"title":"White","offer_id":44127530123363,"sku":"RR-PFC-1.5-3C-WHT","price":18.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_a153d8a4-29ff-461d-b386-dc98fd2f476d.png?v=1786966059"},{"product_id":"rr-pvc-flexible-cable-10mm-5-core","title":"RR Kabel 10mm² 5-Core PVC Flexible Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR PVC Flexible Cable 10mm² 5-Core\u003c\/h2\u003e\n\u003cp\u003eThe RR PVC Flexible Cable 10mm² 5-Core is a very large-section five-wire flexible cable for full three-phase supply to major industrial machinery, large motors, and high-power site equipment. Its 10mm² conductors provide the high current capacity required for the largest portable and semi-fixed equipment in UAE industrial and construction environments. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e10mm² stranded 5-core for high-current three-phase flexible supply\u003c\/li\u003e\n\u003cli\u003eFull L1, L2, L3, N, and E in one cable for complete three-phase connection\u003c\/li\u003e\n\u003cli\u003eHigh current capacity for large industrial motors and plant\u003c\/li\u003e\n\u003cli\u003ePVC insulation and sheath for robust industrial use\u003c\/li\u003e\n\u003cli\u003eSold per metre for large project ordering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e10mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge three-phase motor and pump connections\u003c\/li\u003e\n\u003cli\u003eMajor industrial machinery flexible supply leads\u003c\/li\u003e\n\u003cli\u003eHigh-power construction site equipment connections\u003c\/li\u003e\n\u003cli\u003eIndustrial plant and process equipment three-phase supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10mm² cross-section rating mean, and is it right for my equipment?\u003c\/strong\u003e\u003cbr\u003e10mm² is the copper conductor's cross-sectional area — a large size that gives this cable a high current capacity suited to large motors, pumps, and heavy three-phase machinery. Always match cable size to the equipment's rated current and cable run length; consult an electrician for load and voltage-drop calculations on large installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — sold per metre at a fixed per-metre rate, so you order exactly the length required for your run. No roll minimum, though full drums are typically used for large industrial and site projects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this flexible cable and RR Kabel's XLPE\/SWA Armoured Cable?\u003c\/strong\u003e\u003cbr\u003eXLPE\/SWA armoured cable is a fixed power cable with a steel-wire armour layer, designed for permanent underground or direct-burial installation. This 10mm² 5-core PVC Flexible Cable has no armour and is designed to flex — it's for portable or semi-fixed connections to machinery and equipment that may be moved or reconnected, not for burial or permanent fixed power distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy does this cable have 5 cores?\u003c\/strong\u003e\u003cbr\u003eFive cores provide a complete three-phase supply in a single cable: three line conductors (L1, L2, L3), a neutral (N), and a protective earth (E) — everything needed to connect large three-phase equipment without running separate cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eYes. At this size and current rating, termination and connection should always be carried out by a licensed electrician or qualified panel\/electrical engineer per UAE wiring regulations — this is a trade\/contractor-supply product for industrial and commercial installation, not for DIY use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44127530156131,"sku":"RR-PFC-10-5C-WHT","price":48.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_e1ace322-e64a-44b0-b10d-83f4adde80a6.jpg?v=1786966066"},{"product_id":"rr-pvc-flexible-cable-2-5mm-3-core","title":"RR Kabel 2.5mm² 3-Core PVC Flexible Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR PVC Flexible Cable 2.5mm² 3-Core\u003c\/h2\u003e\n\u003cp\u003eThe RR PVC Flexible Cable 2.5mm² 3-Core is a heavy-duty flexible cable for high-current portable equipment, power tools, and appliance connections requiring an earth conductor. Its 2.5mm² conductor is rated up to 25A, making it the right choice for UAE contractors and FM teams connecting industrial equipment, site tools, and high-load appliances. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2.5mm² fine-stranded 3-core with protective earth conductor\u003c\/li\u003e\n\u003cli\u003eRated up to 25A for heavy portable equipment\u003c\/li\u003e\n\u003cli\u003eAvailable in Black and White\u003c\/li\u003e\n\u003cli\u003ePVC insulation and sheath for durable performance\u003c\/li\u003e\n\u003cli\u003eSold per metre for flexible project ordering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e2.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eBare copper, fine-wire flexible stranding (Class 5, EN 60228)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6500 \/ equivalent BS EN 50525-2-11 (H05VV-F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5°C to +70°C (flexing); up to +70°C fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Colours\u003c\/td\u003e\n\u003ctd\u003eBlack, White\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeavy portable power tools and equipment leads\u003c\/li\u003e\n\u003cli\u003eSite and industrial equipment flexible connections\u003c\/li\u003e\n\u003cli\u003eHigh-load appliance connection cables\u003c\/li\u003e\n\u003cli\u003eCommercial kitchen and HVAC equipment leads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 2.5mm² cross-section rating mean, and is it right for my load?\u003c\/strong\u003e\u003cbr\u003e2.5mm² is the copper conductor's cross-sectional area, giving this cable a current capacity up to around 25A — suited to heavy power tools, site equipment, and high-load appliances. For lighter loads, 1.5mm² is usually sufficient; for larger three-phase machinery, larger cross-sections or more cores may be needed. Confirm with the equipment's rated current or ask an electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — sold per metre at a fixed per-metre rate, so you order and pay for exactly the length you need. No roll minimum, and full coils are available for bulk project orders.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs there any difference between the Black and White versions besides colour?\u003c\/strong\u003e\u003cbr\u003eNo — both are the same 2.5mm² 3-core PVC flexible cable to the same specification. Colour is chosen for identification purposes (e.g. matching site colour-coding or equipment casing).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this and RR Kabel's single-core Building Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire is a solid single conductor for fixed installation in conduit or trunking. This 3-core PVC Flexible Cable is fine-stranded for genuine flexibility and includes its own earth core, designed for connecting portable or moveable equipment rather than permanent circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eConnections into fixed circuits, distribution boards, or permanent equipment should be made by a licensed electrician per UAE wiring regulations, particularly at this current rating. This is a trade\/contractor-supply product, not intended for DIY household wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"RRKabel","offers":[{"title":"Black","offer_id":44127530188899,"sku":"RR-PFC-2.5-3C-BLK","price":18.0,"currency_code":"AED","in_stock":true},{"title":"White","offer_id":44127530221667,"sku":"RR-PFC-2.5-3C-WHT","price":18.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_a153d8a4-29ff-461d-b386-dc98fd2f476d.png?v=1786966059"},{"product_id":"rr-pvc-flexible-cable-2-5mm-4-core","title":"RR Kabel 2.5mm² 4-Core PVC Flexible Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR PVC Flexible Cable 2.5mm² 4-Core\u003c\/h2\u003e\n\u003cp\u003eThe RR PVC Flexible Cable 2.5mm² 4-Core is a four-wire flexible cable for three-phase equipment connections without neutral, single-phase connections with earth and switching conductor, or any application requiring four independently insulated cores in one flexible cable. Sold per metre for UAE industrial, commercial, and contractor projects.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2.5mm² fine-stranded 4-core for multi-circuit flexible connections\u003c\/li\u003e\n\u003cli\u003eSuitable for three-phase or complex single-phase equipment leads\u003c\/li\u003e\n\u003cli\u003ePVC insulation and sheath for robust performance\u003c\/li\u003e\n\u003cli\u003eFlexible construction for moveable and semi-fixed equipment\u003c\/li\u003e\n\u003cli\u003eSold per metre for precise project quantities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e2.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eBare copper, fine-wire flexible stranding (Class 5, EN 60228)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6500 \/ equivalent BS EN 50525-2-11 (H05VV-F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5°C to +70°C (flexing); up to +70°C fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree-phase portable equipment and tool connections\u003c\/li\u003e\n\u003cli\u003eIndustrial machinery flexible supply leads\u003c\/li\u003e\n\u003cli\u003eFour-wire commercial equipment connections\u003c\/li\u003e\n\u003cli\u003eSite distribution board flexible connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 2.5mm² cross-section rating mean, and is it right for my load?\u003c\/strong\u003e\u003cbr\u003e2.5mm² is the copper conductor's cross-sectional area, giving this cable a current capacity suited to moderate three-phase or multi-circuit loads. For larger industrial motors, a larger cross-section (e.g. our 10mm² 5-core) may be needed — check the equipment's rated current or ask an electrician if unsure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — sold per metre at a fixed per-metre rate, so you pay only for the length required. No roll minimum, and full coils are available for larger project orders.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy 4 cores instead of 3 or 5?\u003c\/strong\u003e\u003cbr\u003eFour cores suit applications needing one more conductor than a standard 3-core cable but without a full 5-core three-phase-plus-neutral-plus-earth setup — for example, three-phase supply without neutral, or single-phase supply with earth plus a separate switching\/control conductor. Confirm the exact core function required for your equipment before wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this and RR Kabel's single-core Building Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire is a solid single conductor for fixed installation in conduit. This 4-core PVC Flexible Cable is fine-stranded for genuine flexibility, built to connect portable or semi-fixed equipment rather than permanent building circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eYes — connections for three-phase or multi-circuit equipment should be made by a licensed electrician or qualified panel\/electrical engineer per UAE wiring regulations. This is a trade\/contractor-supply product, not intended for DIY use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44127530254435,"sku":"RR-PFC-2.5-4C-NAT","price":18.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_0ffb5a3f-9068-42e0-9e95-578c02ed8f78.jpg?v=1786966064"},{"product_id":"rr-pvc-flexible-cable-2-5mm-5-core","title":"RR Kabel 2.5mm² 5-Core PVC Flexible Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR PVC Flexible Cable 2.5mm² 5-Core\u003c\/h2\u003e\n\u003cp\u003eThe RR PVC Flexible Cable 2.5mm² 5-Core is a five-wire flexible cable for three-phase plus neutral plus earth connections, suitable for connecting three-phase motors, drives, and industrial equipment with full supply and earth conductors in a single flexible cable. Widely used by UAE contractors, FM teams, and industrial installers. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2.5mm² fine-stranded 5-core for three-phase with neutral and earth\u003c\/li\u003e\n\u003cli\u003eComplete three-phase supply in one flexible cable\u003c\/li\u003e\n\u003cli\u003ePVC insulation and sheath for durable industrial use\u003c\/li\u003e\n\u003cli\u003eFlexible construction for moveable and semi-fixed equipment\u003c\/li\u003e\n\u003cli\u003eSold per metre for accurate project quantities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e2.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree-phase motor and drive flexible connections\u003c\/li\u003e\n\u003cli\u003eFive-wire industrial equipment supply leads\u003c\/li\u003e\n\u003cli\u003eSite distribution board three-phase flexible runs\u003c\/li\u003e\n\u003cli\u003eCommercial HVAC and industrial machinery connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 2.5mm² cross-section rating mean, and how do I know it's the right size for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe mm² figure is the conductor's cross-sectional area, which determines how much current it can safely carry and its resistance over distance. 2.5mm² 5-core is sized for lighter three-phase motor and equipment connections — always confirm load current, cable run length, and voltage drop against the specific equipment's rating (or ask a licensed electrician) before selecting a cross-section.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this cable is sold per metre, so you simply order the exact length your run requires and the price scales with quantity. There's no fixed reel size to buy into for small quantities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this multicore Flexible Cable and RR Kabel's Single-Core Building Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire is a solid single conductor per cable, designed for fixed conduit runs in walls and containment. This PVC Flexible Cable bundles multiple fine-stranded cores (here, 5) under one common sheath, so it flexes and is built for connecting equipment that's moved, vibrates, or needs a single supply lead rather than several separate conductors run in parallel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eYes — three-phase motor and equipment connections should be terminated and installed by a licensed electrician in line with UAE wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does each of the 5 cores carry?\u003c\/strong\u003e\u003cbr\u003eThe five cores provide the three phase conductors (L1, L2, L3), a neutral, and an earth — a complete three-phase supply with protective earth in a single flexible cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44127530287203,"sku":"RR-PFC-2.5-5C-NAT","price":28.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_e1ace322-e64a-44b0-b10d-83f4adde80a6.jpg?v=1786966066"},{"product_id":"rr-pvc-flexible-cable-25mm-5-core","title":"RR Kabel 25mm² 5-Core PVC Flexible Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR PVC Flexible Cable 25mm² 5-Core\u003c\/h2\u003e\n\u003cp\u003eThe RR PVC Flexible Cable 25mm² 5-Core is a premium large-section five-wire flexible cable for the most demanding three-phase industrial connections in UAE projects. Designed for large motors, heavy compressors, and major industrial plant, its 25mm² conductors deliver exceptional current capacity in a single manageable flexible cable. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e25mm² stranded 5-core for the most demanding three-phase connections\u003c\/li\u003e\n\u003cli\u003eExceptional current capacity for large industrial motors and plant\u003c\/li\u003e\n\u003cli\u003eFull five-wire supply — L1, L2, L3, N, and E in one cable\u003c\/li\u003e\n\u003cli\u003ePVC insulation and sheath for industrial-grade durability\u003c\/li\u003e\n\u003cli\u003eSold per metre for large-project precision ordering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e25mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge industrial motor, pump, and compressor connections\u003c\/li\u003e\n\u003cli\u003eMajor construction site plant and generator connections\u003c\/li\u003e\n\u003cli\u003eHeavy industrial process equipment three-phase supply\u003c\/li\u003e\n\u003cli\u003eLarge data centre and critical facility equipment connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 25mm² cross-section rating mean, and how do I know it's the right size for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe mm² figure is the conductor's cross-sectional area, which sets how much current it can safely carry over a given run length. 25mm² is a large-section flexible cable for high-current three-phase loads such as large motors and compressors — always verify load current, run length, and voltage drop against the equipment's nameplate rating (or ask a licensed electrician) before selecting a cross-section this size.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this cable is sold per metre, so you order the exact length your run requires and the price scales with quantity, even at this large cross-section.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this multicore Flexible Cable and RR Kabel's Single-Core Building Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire is a solid single conductor per cable, made for fixed conduit runs in walls and containment. This PVC Flexible Cable bundles multiple fine-stranded cores (here, 5) under one common sheath so it can flex, making it suited to connecting large equipment where routing several separate single-core conductors isn't practical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eYes — at this cross-section it's feeding significant three-phase loads, so termination and installation should be carried out by a licensed electrician per UAE wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does each of the 5 cores carry?\u003c\/strong\u003e\u003cbr\u003eThe five cores provide the three phase conductors (L1, L2, L3), a neutral, and an earth — a complete three-phase supply with protective earth in a single heavy-duty flexible cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44127530319971,"sku":"RR-PFC-25-5C-NAT","price":105.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_e1ace322-e64a-44b0-b10d-83f4adde80a6.jpg?v=1786966066"},{"product_id":"rr-pvc-flexible-cable-4-0mm-5-core","title":"RR Kabel 4.0mm² 5-Core PVC Flexible Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR PVC Flexible Cable 4.0mm² 5-Core\u003c\/h2\u003e\n\u003cp\u003eThe RR PVC Flexible Cable 4.0mm² 5-Core is a five-wire flexible cable for three-phase with neutral and earth connections to heavy portable industrial equipment and machinery. Its 4.0mm² conductors provide the current capacity for demanding three-phase flexible connections across UAE industrial sites and commercial buildings. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4.0mm² fine-stranded 5-core for heavy three-phase flexible connections\u003c\/li\u003e\n\u003cli\u003eFull three-phase, neutral, and earth in one cable\u003c\/li\u003e\n\u003cli\u003ePVC insulation and sheath for industrial-grade durability\u003c\/li\u003e\n\u003cli\u003eFlexible construction for moveable three-phase equipment\u003c\/li\u003e\n\u003cli\u003eSold per metre for accurate project quantities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e4.0mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree-phase industrial machinery flexible supply\u003c\/li\u003e\n\u003cli\u003eHeavy portable equipment and site tool connections\u003c\/li\u003e\n\u003cli\u003eFive-wire motor and drive flexible leads\u003c\/li\u003e\n\u003cli\u003eIndustrial plant and commercial three-phase connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 4.0mm² cross-section rating mean, and how do I know it's the right size for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe mm² figure is the conductor's cross-sectional area, which determines how much current it can safely carry over a given run length. 4.0mm² 5-core is sized for heavier three-phase motor and machinery connections — always confirm load current, run length, and voltage drop against the equipment's rating (or ask a licensed electrician) before selecting a cross-section.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this cable is sold per metre, so you order the exact length your run requires and the price scales with quantity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this multicore Flexible Cable and RR Kabel's Single-Core Building Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire is a solid single conductor per cable, designed for fixed conduit runs in walls and containment. This PVC Flexible Cable bundles multiple fine-stranded cores (here, 5) under one common sheath, so it flexes and is built as a single supply lead for equipment that's moved, vibrates, or needs a combined three-phase feed rather than several separate conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eYes — three-phase machinery connections at this current rating should be terminated and installed by a licensed electrician per UAE wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does each of the 5 cores carry?\u003c\/strong\u003e\u003cbr\u003eThe five cores provide the three phase conductors (L1, L2, L3), a neutral, and an earth — a complete three-phase supply with protective earth in a single flexible cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44127530451043,"sku":"RR-PFC-4.0-5C-NAT","price":26.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_e1ace322-e64a-44b0-b10d-83f4adde80a6.jpg?v=1786966066"},{"product_id":"rr-pvc-flexible-cable-6-0mm-4-core","title":"RR Kabel 6.0mm² 4-Core PVC Flexible Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR PVC Flexible Cable 6.0mm² 4-Core\u003c\/h2\u003e\n\u003cp\u003eThe RR PVC Flexible Cable 6.0mm² 4-Core is a heavy-duty four-wire flexible cable for high-current three-phase equipment without separate neutral, industrial machinery, and large portable equipment connections. Its 6.0mm² conductors deliver the current capacity required for demanding three-phase applications across UAE industrial and commercial projects. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e6.0mm² fine-stranded 4-core for heavy three-phase flexible connections\u003c\/li\u003e\n\u003cli\u003eHigh current capacity for large industrial equipment\u003c\/li\u003e\n\u003cli\u003ePVC insulation and sheath for industrial-grade durability\u003c\/li\u003e\n\u003cli\u003eFlexible construction for moveable and semi-fixed heavy equipment\u003c\/li\u003e\n\u003cli\u003eSold per metre for precise ordering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e6.0mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeavy three-phase industrial machinery connections\u003c\/li\u003e\n\u003cli\u003eLarge portable equipment and site plant leads\u003c\/li\u003e\n\u003cli\u003eCommercial HVAC and chiller flexible supply\u003c\/li\u003e\n\u003cli\u003eIndustrial process equipment flexible connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6.0mm² cross-section rating mean, and how do I know it's the right size for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe mm² figure is the conductor's cross-sectional area, which determines how much current it can safely carry over a given run length. 6.0mm² 4-core is sized for high-current three-phase machinery without a neutral requirement — always confirm load current, run length, and voltage drop against the equipment's rating (or ask a licensed electrician) before selecting a cross-section.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this cable is sold per metre, so you order the exact length your run requires and the price scales with quantity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this multicore Flexible Cable and RR Kabel's Single-Core Building Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire is a solid single conductor per cable, designed for fixed conduit runs in walls and containment. This PVC Flexible Cable bundles multiple fine-stranded cores (here, 4) under one common sheath, so it flexes and is built as a single supply lead for equipment that's moved or vibrates, rather than several separate conductors run in parallel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eYes — three-phase machinery connections at this current rating should be terminated and installed by a licensed electrician per UAE wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does each of the 4 cores carry?\u003c\/strong\u003e\u003cbr\u003eThe four cores are the three phase conductors (L1, L2, L3) plus an earth — used where the load doesn't require a neutral, such as three-phase motor connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44127530483811,"sku":"RR-PFC-6.0-4C-WHT","price":30.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_d104cee5-1635-4738-a16a-16ddce1d3105.jpg?v=1786966129"},{"product_id":"rr-pvc-flexible-cable-6-0mm-5-core","title":"RR Kabel 6.0mm² 5-Core PVC Flexible Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR PVC Flexible Cable 6.0mm² 5-Core\u003c\/h2\u003e\n\u003cp\u003eThe RR PVC Flexible Cable 6.0mm² 5-Core delivers full three-phase, neutral, and earth supply in a single heavy-duty flexible cable. Its 6.0mm² conductors are suited for the heaviest portable industrial equipment, large motors, and site plant connections across UAE construction and industrial projects. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e6.0mm² fine-stranded 5-core for complete three-phase flexible supply\u003c\/li\u003e\n\u003cli\u003eFull L1, L2, L3, N, and E in one heavy-duty cable\u003c\/li\u003e\n\u003cli\u003ePVC insulation and sheath for robust industrial performance\u003c\/li\u003e\n\u003cli\u003eFlexible stranding for manageable routing at large cross-section\u003c\/li\u003e\n\u003cli\u003eSold per metre for project-accurate ordering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e6.0mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeavy industrial machinery three-phase flexible supply\u003c\/li\u003e\n\u003cli\u003eLarge site plant and equipment connections\u003c\/li\u003e\n\u003cli\u003eIndustrial process three-phase motor flexible leads\u003c\/li\u003e\n\u003cli\u003eCommercial building services heavy equipment connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6.0mm² cross-section rating mean, and how do I know it's the right size for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe mm² figure is the conductor's cross-sectional area, which determines how much current it can safely carry over a given run length. 6.0mm² 5-core is sized for heavy three-phase equipment needing a neutral — always confirm load current, run length, and voltage drop against the equipment's rating (or ask a licensed electrician) before selecting a cross-section.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this cable is sold per metre, so you order the exact length your run requires and the price scales with quantity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this multicore Flexible Cable and RR Kabel's Single-Core Building Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire is a solid single conductor per cable, designed for fixed conduit runs in walls and containment. This PVC Flexible Cable bundles multiple fine-stranded cores (here, 5) under one common sheath, so it flexes and is built as a single supply lead for large equipment rather than several separate conductors run in parallel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eYes — three-phase machinery connections at this current rating should be terminated and installed by a licensed electrician per UAE wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does each of the 5 cores carry?\u003c\/strong\u003e\u003cbr\u003eThe five cores provide the three phase conductors (L1, L2, L3), a neutral, and an earth — a complete three-phase supply with protective earth in a single heavy-duty flexible cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44127530549347,"sku":"RR-PFC-6.0-5C-NAT","price":32.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_e1ace322-e64a-44b0-b10d-83f4adde80a6.jpg?v=1786966066"},{"product_id":"rr-pvc-flexible-cable-16mm-5-core","title":"RR Kabel 16mm² 5-Core PVC Flexible Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR PVC Flexible Cable 16mm² 5-Core\u003c\/h2\u003e\n\u003cp\u003eThe RR PVC Flexible Cable 16mm² 5-Core is a large-section five-wire flexible cable for the highest-current three-phase portable connections in UAE industrial projects. Its 16mm² conductors are suited for connecting large industrial motors, compressors, and high-power plant requiring full three-phase, neutral, and earth supply in a single flexible cable. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16mm² stranded 5-core for very high-current three-phase applications\u003c\/li\u003e\n\u003cli\u003eFull five-wire supply for complete three-phase equipment connections\u003c\/li\u003e\n\u003cli\u003ePVC insulation and sheath for industrial durability\u003c\/li\u003e\n\u003cli\u003eStranded construction for flexibility at large cross-section\u003c\/li\u003e\n\u003cli\u003eSold per metre for precision project ordering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e16mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300\/500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge industrial motor and compressor connections\u003c\/li\u003e\n\u003cli\u003eHigh-power three-phase site plant and equipment\u003c\/li\u003e\n\u003cli\u003eIndustrial process machinery three-phase flexible supply\u003c\/li\u003e\n\u003cli\u003eLarge commercial HVAC and refrigeration equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 16mm² cross-section rating mean, and how do I know it's the right size for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe mm² figure is the conductor's cross-sectional area, which determines how much current it can safely carry over a given run length. 16mm² 5-core is a large-section flexible cable for very high-current three-phase loads such as large motors and compressors — always verify load current, run length, and voltage drop against the equipment's nameplate rating (or ask a licensed electrician) before selecting a cross-section this size.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this cable is sold per metre, so you order the exact length your run requires and the price scales with quantity, even at this large cross-section.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this multicore Flexible Cable and RR Kabel's Single-Core Building Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire is a solid single conductor per cable, made for fixed conduit runs in walls and containment. This PVC Flexible Cable bundles multiple fine-stranded cores (here, 5) under one common sheath so it can flex, making it suited to connecting large equipment where routing several separate single-core conductors isn't practical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eYes — at this cross-section it's feeding significant three-phase loads, so termination and installation should be carried out by a licensed electrician per UAE wiring regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does each of the 5 cores carry?\u003c\/strong\u003e\u003cbr\u003eThe five cores provide the three phase conductors (L1, L2, L3), a neutral, and an earth — a complete three-phase supply with protective earth in a single heavy-duty flexible cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44127530582115,"sku":"RR-PFC-16-5C-NAT","price":55.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_e1ace322-e64a-44b0-b10d-83f4adde80a6.jpg?v=1786966066"},{"product_id":"rr-single-core-cable-10mm","title":"RR Kabel 10mm² Single-Core Building Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Single Core Cable 10mm²\u003c\/h2\u003e\n\u003cp\u003eThe RR Single Core Cable 10mm² is a heavy-duty single-core conductor for high-current power circuits, sub-mains, and distribution wiring in UAE commercial and industrial buildings. Available in Black, Blue, Red, and Yellow, it provides full colour-coding for three-phase and neutral conductors in conduit and trunking installations. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e10mm² conductor for high-current power and sub-main circuits\u003c\/li\u003e\n\u003cli\u003eAvailable in Black, Blue, Red, and Yellow for phase and neutral identification\u003c\/li\u003e\n\u003cli\u003ePVC insulation for conduit and trunking installations\u003c\/li\u003e\n\u003cli\u003eSold per metre for accurate project ordering\u003c\/li\u003e\n\u003cli\u003eGenuine RR Cables quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e10mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e450\/750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Colours\u003c\/td\u003e\n\u003ctd\u003eBlack, Blue, Red, Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Packing\u003c\/td\u003e\n\u003ctd\u003e100m standard coil (longer lengths available on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-15°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSub-main and distribution feeder circuits\u003c\/li\u003e\n\u003cli\u003eHigh-current commercial power installations\u003c\/li\u003e\n\u003cli\u003eIndustrial distribution board wiring\u003c\/li\u003e\n\u003cli\u003eConduit and trunking three-phase installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10mm² cross-section rating mean, and how do I pick the right size for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe mm² figure is the conductor's copper cross-sectional area, which determines how much current the wire can safely carry and its voltage drop over distance. Larger cross-sections carry higher currents over longer runs. Confirm the correct size for your circuit's load and cable length against the applicable wiring regulations (or ask our technical team) before ordering — this listing is for the conductor itself, not a substitute for a proper circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this wire is sold per metre, so you enter the exact quantity of metres you need at checkout and are charged accordingly. There's no minimum roll or coil requirement; order 5 metres or 500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between Single-Core Building Wire and RR Kabel's Flexible Panel Wire?\u003c\/strong\u003e\u003cbr\u003eBuilding Wire uses a solid or low-strand-count conductor designed for fixed, permanent installation in walls, conduit, and trunking. Flexible Panel Wire uses a finer, multi-strand flexible conductor designed for movement and repeated flexing inside control panels and switchboards. Use Building Wire for fixed circuit wiring; use Flexible Panel Wire for panel\/control cabinet internal wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by an electrician?\u003c\/strong\u003e\u003cbr\u003eYes. Fixed building wiring must be installed and terminated by a licensed electrician in line with UAE wiring regulations — this is a supply-only conductor, not a DIY plug-and-play product.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy do the colours (Red\/Yellow\/Blue\/Black) matter, and can I mix colours in one order?\u003c\/strong\u003e\u003cbr\u003eColour-coding identifies phase, neutral, and circuit function so an electrician can trace and safely isolate circuits later. You can order any mix of colours and lengths in the same purchase — each colour is simply a separate variant of the same 10mm² wire.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Black","offer_id":44127530614883,"sku":"RR-SC-10-BLK","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Blue","offer_id":44127530647651,"sku":"RR-SC-10-BLU","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Red","offer_id":44127530680419,"sku":"RR-SC-10-RED","price":19.0,"currency_code":"AED","in_stock":true},{"title":"Yellow","offer_id":44127530713187,"sku":"RR-SC-10-YEL","price":19.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_ad880ecf-53ff-4f7b-941a-1a9991e806f4.png?v=1786965892"},{"product_id":"rr-single-core-earth-wire-10mm","title":"RR Kabel 10mm² Single-Core Earth Wire — Green\/Yellow PVC","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Single Core Earth Wire 10mm²\u003c\/h2\u003e\n\u003cp\u003eThe RR Single Core Earth Wire 10mm² is a Yellow\/Green single-core conductor for main protective earth connections, main bonding conductors, and high fault-current earth paths in UAE commercial and industrial electrical installations. Its 10mm² cross-section provides robust fault current capacity for sub-main earthing systems. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e10mm² conductor for main earth and primary bonding applications\u003c\/li\u003e\n\u003cli\u003eYellow\/Green insulation for compliant earth conductor identification\u003c\/li\u003e\n\u003cli\u003eRobust fault current capacity for sub-main and main earthing\u003c\/li\u003e\n\u003cli\u003ePVC insulation for conduit and trunking installations\u003c\/li\u003e\n\u003cli\u003eSold per metre for accurate project quantities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e10mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eYellow\/Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003ePlain annealed copper, stranded (Class 2), per BS EN 60228 \/ IEC 60228\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e450\/750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6004 (now BS EN 50525-2-31 – H07V-R design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain protective earth conductors in commercial distribution boards\u003c\/li\u003e\n\u003cli\u003eMain equipotential bonding in industrial installations\u003c\/li\u003e\n\u003cli\u003eSub-main circuit protective conductors\u003c\/li\u003e\n\u003cli\u003eStructural steelwork and service bonding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy is this wire green\/yellow, and does the colour-coding actually matter?\u003c\/strong\u003e\u003cbr\u003eGreen\/yellow dual-colour insulation is the internationally recognised marking (IEC 60446, carried through into BS 7671 and UAE wiring regulations) reserved exclusively for protective earth (PE) and bonding conductors — no other core in an installation is permitted to use this colour combination. That matters beyond labelling: fast, unambiguous identification during installation, inspection, and fault-finding prevents an earth conductor being confused with a live or neutral core, which is one of the most common causes of a miswired protective connection. The bonding function itself depends on it — every exposed metal enclosure, gland, and extraneous conductive part (structural steel, pipework) must be traced back to the main earthing terminal to form a continuous, low-impedance path, so that under a fault an RCD or circuit breaker trips fast enough to clear the touch-voltage hazard. A conductor that is hard to identify is one that is easy to omit, damage, or disconnect during future works — the colour is what keeps that path intact and verifiable at every stage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10mm² rating mean, and how do I size the earth conductor for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe 10mm² figure is the copper conductor's cross-sectional area, which determines how much fault current it can carry momentarily without overheating before the protective device (fuse, MCB, or RCD) clears the fault. As a general principle under IEC 60364-5-54 \/ BS 7671 Table 54.7 — the basis for UAE wiring regulations — the protective\/earth conductor is sized relative to the associated line conductor: matching cross-section up to 16mm² of line conductor, then roughly half (minimum 16mm²) for larger line conductors. In this catalogue, this 10mm² size is typically specified for sub-main and main earthing runs and main bonding conductors feeding commercial\/industrial distribution boards. Always confirm the exact size against your specific circuit design, fault-current calculation, and local wiring regulations — a qualified electrical engineer or electrician should verify the value for your project.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this earth wire is sold per metre, so you can order any length to match your run (for example 37m or 158m). The listed price is per metre; enter the quantity in metres you need and we cut and supply that exact length. For large or full-reel quantities, contact us for coil pricing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this Earth Wire and RR Kabel's Single-Core Building Wire (line\/neutral) range?\u003c\/strong\u003e\u003cbr\u003eBoth share the same underlying construction — single-core, stranded plain annealed copper, PVC insulated, rated 450\/750V to the H07V-R design (BS EN 50525-2-31, the harmonised successor to BS 6004). The difference is purely the insulation colour and its designated function: the Building Wire range (single colours — red, blue, black, yellow) carries line and neutral conductors, while this Green\/Yellow product is manufactured and colour-coded exclusively as the protective earth\/bonding conductor. The two should never be substituted for one another on site.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by a licensed electrician?\u003c\/strong\u003e\u003cbr\u003eYes. Earthing and bonding conductors are safety-critical fixed wiring — correct sizing, termination, and continuity testing must be carried out by a licensed electrician in accordance with UAE wiring regulations (based on BS 7671\/IEC 60364), including verification of earth continuity and loop impedance before the installation is energised.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44127530745955,"sku":"RR-SCE-10-YG","price":19.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/GYEARTH1_s_dbdd488f-d777-4727-8e35-25a8c012b559.jpg?v=1786966148"},{"product_id":"rr-single-core-earth-wire-4-0mm","title":"RR Kabel 4mm² Single-Core Earth Wire — Green\/Yellow PVC","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Single Core Earth Wire 4.0mm²\u003c\/h2\u003e\n\u003cp\u003eThe RR Single Core Earth Wire 4.0mm² is a Yellow\/Green single-core conductor dedicated to protective earth and equipotential bonding applications in UAE residential, commercial, and industrial installations. Its 4.0mm² cross-section is suitable for circuit protective conductors and supplementary bonding connections. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4.0mm² conductor for circuit protective earth and bonding\u003c\/li\u003e\n\u003cli\u003eYellow\/Green insulation for instant earth conductor identification\u003c\/li\u003e\n\u003cli\u003ePVC insulation for fixed wiring in conduit and trunking\u003c\/li\u003e\n\u003cli\u003eComplies with earth conductor colour-coding requirements\u003c\/li\u003e\n\u003cli\u003eSold per metre for precise ordering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e4.0mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eYellow\/Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003ePlain annealed copper, stranded (Class 2), per BS EN 60228 \/ IEC 60228\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e450\/750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6004 (now BS EN 50525-2-31 – H07V-R design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCircuit protective conductors (CPC) in fixed wiring installations\u003c\/li\u003e\n\u003cli\u003eSupplementary and equipotential bonding\u003c\/li\u003e\n\u003cli\u003eConsumer unit and distribution board earth connections\u003c\/li\u003e\n\u003cli\u003eStructural steelwork and extraneous conductive parts bonding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy is this wire green\/yellow, and does the colour-coding actually matter?\u003c\/strong\u003e\u003cbr\u003eGreen\/yellow dual-colour insulation is the internationally recognised marking (IEC 60446, carried through into BS 7671 and UAE wiring regulations) reserved exclusively for protective earth (PE) and bonding conductors — no other core in an installation is permitted to use this colour combination. That matters beyond labelling: fast, unambiguous identification during installation, inspection, and fault-finding prevents an earth conductor being confused with a live or neutral core, which is one of the most common causes of a miswired protective connection. The bonding function itself depends on it — every exposed metal enclosure, gland, and extraneous conductive part (structural steel, pipework) must be traced back to the main earthing terminal to form a continuous, low-impedance path, so that under a fault an RCD or circuit breaker trips fast enough to clear the touch-voltage hazard. A conductor that is hard to identify is one that is easy to omit, damage, or disconnect during future works — the colour is what keeps that path intact and verifiable at every stage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 4.0mm² rating mean, and how do I size the earth conductor for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe 4.0mm² figure is the copper conductor's cross-sectional area, which determines how much fault current it can carry momentarily without overheating before the protective device (fuse, MCB, or RCD) clears the fault. As a general principle under IEC 60364-5-54 \/ BS 7671 Table 54.7 — the basis for UAE wiring regulations — the protective\/earth conductor is sized relative to the associated line conductor: matching cross-section up to 16mm² of line conductor, then roughly half (minimum 16mm²) for larger line conductors. In this catalogue, this 4.0mm² size is typically specified as the circuit protective conductor (CPC) for final sub-circuits and consumer-unit earth connections. Always confirm the exact size against your specific circuit design, fault-current calculation, and local wiring regulations — a qualified electrical engineer or electrician should verify the value for your project.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this earth wire is sold per metre, so you can order any length to match your run (for example 37m or 158m). The listed price is per metre; enter the quantity in metres you need and we cut and supply that exact length. For large or full-reel quantities, contact us for coil pricing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this Earth Wire and RR Kabel's Single-Core Building Wire (line\/neutral) range?\u003c\/strong\u003e\u003cbr\u003eBoth share the same underlying construction — single-core, stranded plain annealed copper, PVC insulated, rated 450\/750V to the H07V-R design (BS EN 50525-2-31, the harmonised successor to BS 6004). The difference is purely the insulation colour and its designated function: the Building Wire range (single colours — red, blue, black, yellow) carries line and neutral conductors, while this Green\/Yellow product is manufactured and colour-coded exclusively as the protective earth\/bonding conductor. The two should never be substituted for one another on site.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by a licensed electrician?\u003c\/strong\u003e\u003cbr\u003eYes. Earthing and bonding conductors are safety-critical fixed wiring — correct sizing, termination, and continuity testing must be carried out by a licensed electrician in accordance with UAE wiring regulations (based on BS 7671\/IEC 60364), including verification of earth continuity and loop impedance before the installation is energised.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44128252952675,"sku":"RR-SCE-4.0-YG","price":16.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/GYEARTH1_s_dbdd488f-d777-4727-8e35-25a8c012b559.jpg?v=1786966148"},{"product_id":"rr-single-core-earth-wire-6-0mm","title":"RR Kabel 6mm² Single-Core Earth Wire — Green\/Yellow PVC","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Single Core Earth Wire 6.0mm²\u003c\/h2\u003e\n\u003cp\u003eThe RR Single Core Earth Wire 6.0mm² is a robust Yellow\/Green earth conductor for main protective earth connections, main bonding conductors, and high fault-current earth paths in UAE commercial and industrial installations. Sold per metre for accurate earthing system project quantities.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e6.0mm² conductor for main protective earth and primary bonding\u003c\/li\u003e\n\u003cli\u003eYellow\/Green insulation for compliant earth conductor identification\u003c\/li\u003e\n\u003cli\u003eHigher fault current capacity than 4mm² earth wire\u003c\/li\u003e\n\u003cli\u003ePVC insulation for conduit and trunking installations\u003c\/li\u003e\n\u003cli\u003eSold per metre for project precision\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e6.0mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eYellow\/Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003ePlain annealed copper, stranded (Class 2), per BS EN 60228 \/ IEC 60228\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e450\/750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6004 (now BS EN 50525-2-31 – H07V-R design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain protective earth conductors in distribution boards\u003c\/li\u003e\n\u003cli\u003eMain equipotential bonding to gas, water, and structural services\u003c\/li\u003e\n\u003cli\u003eEarth conductor in sub-main wiring systems\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial earthing system installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy is this wire green\/yellow, and does the colour-coding actually matter?\u003c\/strong\u003e\u003cbr\u003eGreen\/yellow dual-colour insulation is the internationally recognised marking (IEC 60446, carried through into BS 7671 and UAE wiring regulations) reserved exclusively for protective earth (PE) and bonding conductors — no other core in an installation is permitted to use this colour combination. That matters beyond labelling: fast, unambiguous identification during installation, inspection, and fault-finding prevents an earth conductor being confused with a live or neutral core, which is one of the most common causes of a miswired protective connection. The bonding function itself depends on it — every exposed metal enclosure, gland, and extraneous conductive part (structural steel, pipework) must be traced back to the main earthing terminal to form a continuous, low-impedance path, so that under a fault an RCD or circuit breaker trips fast enough to clear the touch-voltage hazard. A conductor that is hard to identify is one that is easy to omit, damage, or disconnect during future works — the colour is what keeps that path intact and verifiable at every stage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6.0mm² rating mean, and how do I size the earth conductor for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe 6.0mm² figure is the copper conductor's cross-sectional area, which determines how much fault current it can carry momentarily without overheating before the protective device (fuse, MCB, or RCD) clears the fault. As a general principle under IEC 60364-5-54 \/ BS 7671 Table 54.7 — the basis for UAE wiring regulations — the protective\/earth conductor is sized relative to the associated line conductor: matching cross-section up to 16mm² of line conductor, then roughly half (minimum 16mm²) for larger line conductors. In this catalogue, this 6.0mm² size is typically specified for main protective earth connections and main equipotential bonding in commercial and industrial distribution boards. Always confirm the exact size against your specific circuit design, fault-current calculation, and local wiring regulations — a qualified electrical engineer or electrician should verify the value for your project.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this earth wire is sold per metre, so you can order any length to match your run (for example 37m or 158m). The listed price is per metre; enter the quantity in metres you need and we cut and supply that exact length. For large or full-reel quantities, contact us for coil pricing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this Earth Wire and RR Kabel's Single-Core Building Wire (line\/neutral) range?\u003c\/strong\u003e\u003cbr\u003eBoth share the same underlying construction — single-core, stranded plain annealed copper, PVC insulated, rated 450\/750V to the H07V-R design (BS EN 50525-2-31, the harmonised successor to BS 6004). The difference is purely the insulation colour and its designated function: the Building Wire range (single colours — red, blue, black, yellow) carries line and neutral conductors, while this Green\/Yellow product is manufactured and colour-coded exclusively as the protective earth\/bonding conductor. The two should never be substituted for one another on site.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by a licensed electrician?\u003c\/strong\u003e\u003cbr\u003eYes. Earthing and bonding conductors are safety-critical fixed wiring — correct sizing, termination, and continuity testing must be carried out by a licensed electrician in accordance with UAE wiring regulations (based on BS 7671\/IEC 60364), including verification of earth continuity and loop impedance before the installation is energised.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44128255705187,"sku":"RR-SCE-6.0-YG","price":16.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/GYEARTH1_s_dbdd488f-d777-4727-8e35-25a8c012b559.jpg?v=1786966148"},{"product_id":"rr-single-core-earth-wire-16mm","title":"RR Kabel 16mm² Single-Core Earth Wire — Green\/Yellow PVC","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Single Core Earth Wire 16mm²\u003c\/h2\u003e\n\u003cp\u003eThe RR Single Core Earth Wire 16mm² is a large-section Yellow\/Green earth conductor for main incoming earth connections, high-capacity bonding conductors, and heavy-duty earthing system runs in UAE large commercial and industrial installations. Its 16mm² cross-section handles substantial fault currents for main distribution earthing. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16mm² conductor for main incoming earth and heavy bonding applications\u003c\/li\u003e\n\u003cli\u003eYellow\/Green insulation for compliant earth conductor identification\u003c\/li\u003e\n\u003cli\u003eHigh fault current capacity for large commercial earthing systems\u003c\/li\u003e\n\u003cli\u003ePVC insulation for cable tray and trunking installations\u003c\/li\u003e\n\u003cli\u003eSold per metre for large-project earthing system quantities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e16mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eYellow\/Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003ePlain annealed copper, stranded (Class 2), per BS EN 60228 \/ IEC 60228\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e450\/750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6004 (now BS EN 50525-2-31 – H07V-R design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain incoming earth conductor at main distribution boards\u003c\/li\u003e\n\u003cli\u003eHeavy equipotential bonding in large commercial buildings\u003c\/li\u003e\n\u003cli\u003eIndustrial plant main earthing system runs\u003c\/li\u003e\n\u003cli\u003eMDB and sub-main distribution earth conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy is this wire green\/yellow, and does the colour-coding actually matter?\u003c\/strong\u003e\u003cbr\u003eGreen\/yellow dual-colour insulation is the internationally recognised marking (IEC 60446, carried through into BS 7671 and UAE wiring regulations) reserved exclusively for protective earth (PE) and bonding conductors — no other core in an installation is permitted to use this colour combination. That matters beyond labelling: fast, unambiguous identification during installation, inspection, and fault-finding prevents an earth conductor being confused with a live or neutral core, which is one of the most common causes of a miswired protective connection. The bonding function itself depends on it — every exposed metal enclosure, gland, and extraneous conductive part (structural steel, pipework) must be traced back to the main earthing terminal to form a continuous, low-impedance path, so that under a fault an RCD or circuit breaker trips fast enough to clear the touch-voltage hazard. A conductor that is hard to identify is one that is easy to omit, damage, or disconnect during future works — the colour is what keeps that path intact and verifiable at every stage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 16mm² rating mean, and how do I size the earth conductor for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe 16mm² figure is the copper conductor's cross-sectional area, which determines how much fault current it can carry momentarily without overheating before the protective device (fuse, MCB, or RCD) clears the fault. As a general principle under IEC 60364-5-54 \/ BS 7671 Table 54.7 — the basis for UAE wiring regulations — the protective\/earth conductor is sized relative to the associated line conductor: matching cross-section up to 16mm² of line conductor, then roughly half (minimum 16mm²) for larger line conductors. In this catalogue, this 16mm² size is typically specified for main incoming earth connections and heavy bonding runs at main distribution boards (MDB) in larger installations. Always confirm the exact size against your specific circuit design, fault-current calculation, and local wiring regulations — a qualified electrical engineer or electrician should verify the value for your project.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this earth wire is sold per metre, so you can order any length to match your run (for example 37m or 158m). The listed price is per metre; enter the quantity in metres you need and we cut and supply that exact length. For large or full-reel quantities, contact us for coil pricing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this Earth Wire and RR Kabel's Single-Core Building Wire (line\/neutral) range?\u003c\/strong\u003e\u003cbr\u003eBoth share the same underlying construction — single-core, stranded plain annealed copper, PVC insulated, rated 450\/750V to the H07V-R design (BS EN 50525-2-31, the harmonised successor to BS 6004). The difference is purely the insulation colour and its designated function: the Building Wire range (single colours — red, blue, black, yellow) carries line and neutral conductors, while this Green\/Yellow product is manufactured and colour-coded exclusively as the protective earth\/bonding conductor. The two should never be substituted for one another on site.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by a licensed electrician?\u003c\/strong\u003e\u003cbr\u003eYes. Earthing and bonding conductors are safety-critical fixed wiring — correct sizing, termination, and continuity testing must be carried out by a licensed electrician in accordance with UAE wiring regulations (based on BS 7671\/IEC 60364), including verification of earth continuity and loop impedance before the installation is energised.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44128259670115,"sku":"RR-SCE-16-YG","price":20.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/GYEARTH1_s_dbdd488f-d777-4727-8e35-25a8c012b559.jpg?v=1786966148"},{"product_id":"rr-single-core-earth-wire-50mm","title":"RR Kabel 50mm² Single-Core Earth Wire — Green\/Yellow PVC","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Single Core Earth Wire 50mm²\u003c\/h2\u003e\n\u003cp\u003eThe RR Single Core Earth Wire 50mm² is a very large-section Yellow\/Green earth conductor for main incoming earthing, high-capacity bonding bars, and major industrial earthing systems in UAE large-scale commercial and industrial projects. Its 50mm² cross-section provides exceptional fault current capacity for the most demanding earthing applications. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e50mm² conductor for main incoming earth and major bonding applications\u003c\/li\u003e\n\u003cli\u003eYellow\/Green insulation for compliant earth identification\u003c\/li\u003e\n\u003cli\u003eExceptional fault current capacity for large industrial earthing systems\u003c\/li\u003e\n\u003cli\u003ePVC insulation for cable tray and large trunking installations\u003c\/li\u003e\n\u003cli\u003eSold per metre for precise large-project quantities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e50mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eYellow\/Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003ePlain annealed copper, stranded (Class 2), per BS EN 60228 \/ IEC 60228\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e450\/750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6004 (now BS EN 50525-2-31 – H07V-R design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain incoming earth at large MDB and switchgear\u003c\/li\u003e\n\u003cli\u003eMajor industrial earthing grid and bonding bar connections\u003c\/li\u003e\n\u003cli\u003eData centre and critical infrastructure main earth conductors\u003c\/li\u003e\n\u003cli\u003eLarge transformer and generator earthing connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy is this wire green\/yellow, and does the colour-coding actually matter?\u003c\/strong\u003e\u003cbr\u003eGreen\/yellow dual-colour insulation is the internationally recognised marking (IEC 60446, carried through into BS 7671 and UAE wiring regulations) reserved exclusively for protective earth (PE) and bonding conductors — no other core in an installation is permitted to use this colour combination. That matters beyond labelling: fast, unambiguous identification during installation, inspection, and fault-finding prevents an earth conductor being confused with a live or neutral core, which is one of the most common causes of a miswired protective connection. The bonding function itself depends on it — every exposed metal enclosure, gland, and extraneous conductive part (structural steel, pipework) must be traced back to the main earthing terminal to form a continuous, low-impedance path, so that under a fault an RCD or circuit breaker trips fast enough to clear the touch-voltage hazard. A conductor that is hard to identify is one that is easy to omit, damage, or disconnect during future works — the colour is what keeps that path intact and verifiable at every stage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 50mm² rating mean, and how do I size the earth conductor for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe 50mm² figure is the copper conductor's cross-sectional area, which determines how much fault current it can carry momentarily without overheating before the protective device (fuse, MCB, or RCD) clears the fault. As a general principle under IEC 60364-5-54 \/ BS 7671 Table 54.7 — the basis for UAE wiring regulations — the protective\/earth conductor is sized relative to the associated line conductor: matching cross-section up to 16mm² of line conductor, then roughly half (minimum 16mm²) for larger line conductors. In this catalogue, this 50mm² size is typically specified for main incoming earth at large switchgear\/MDB installations and major industrial earthing grids. Always confirm the exact size against your specific circuit design, fault-current calculation, and local wiring regulations — a qualified electrical engineer or electrician should verify the value for your project.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this earth wire is sold per metre, so you can order any length to match your run (for example 37m or 158m). The listed price is per metre; enter the quantity in metres you need and we cut and supply that exact length. For large or full-reel quantities, contact us for coil pricing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this Earth Wire and RR Kabel's Single-Core Building Wire (line\/neutral) range?\u003c\/strong\u003e\u003cbr\u003eBoth share the same underlying construction — single-core, stranded plain annealed copper, PVC insulated, rated 450\/750V to the H07V-R design (BS EN 50525-2-31, the harmonised successor to BS 6004). The difference is purely the insulation colour and its designated function: the Building Wire range (single colours — red, blue, black, yellow) carries line and neutral conductors, while this Green\/Yellow product is manufactured and colour-coded exclusively as the protective earth\/bonding conductor. The two should never be substituted for one another on site.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by a licensed electrician?\u003c\/strong\u003e\u003cbr\u003eYes. Earthing and bonding conductors are safety-critical fixed wiring — correct sizing, termination, and continuity testing must be carried out by a licensed electrician in accordance with UAE wiring regulations (based on BS 7671\/IEC 60364), including verification of earth continuity and loop impedance before the installation is energised.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44128259702883,"sku":"RR-SCE-50-YG","price":45.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/GYEARTH1_s_dbdd488f-d777-4727-8e35-25a8c012b559.jpg?v=1786966148"},{"product_id":"rr-single-core-earth-wire-70mm","title":"RR Kabel 70mm² Single-Core Earth Wire — Green\/Yellow PVC","description":"\u003cdiv\u003e\n\u003ch2\u003eRR Single Core Earth Wire 70mm²\u003c\/h2\u003e\n\u003cp\u003eThe RR Single Core Earth Wire 70mm² is a premium large-section Yellow\/Green earth conductor for the most demanding main incoming earthing systems, transformer earthing, and major industrial bonding applications in UAE large commercial and industrial projects. Its 70mm² cross-section provides maximum fault current capacity for critical earthing installations. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e70mm² conductor for critical main earthing and transformer bonding\u003c\/li\u003e\n\u003cli\u003eYellow\/Green insulation for compliant earth conductor identification\u003c\/li\u003e\n\u003cli\u003eMaximum fault current capacity for large incoming earthing systems\u003c\/li\u003e\n\u003cli\u003ePVC insulation for cable tray installations\u003c\/li\u003e\n\u003cli\u003eSold per metre for large critical infrastructure projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e70mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eYellow\/Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003ePlain annealed copper, stranded (Class 2), per BS EN 60228 \/ IEC 60228\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e450\/750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 6004 (now BS EN 50525-2-31 – H07V-R design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain incoming earth at HV\/LV transformer substations\u003c\/li\u003e\n\u003cli\u003eCritical infrastructure and data centre main earth conductors\u003c\/li\u003e\n\u003cli\u003eMajor industrial earthing grid connections\u003c\/li\u003e\n\u003cli\u003eGenerator and large UPS system earthing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy is this wire green\/yellow, and does the colour-coding actually matter?\u003c\/strong\u003e\u003cbr\u003eGreen\/yellow dual-colour insulation is the internationally recognised marking (IEC 60446, carried through into BS 7671 and UAE wiring regulations) reserved exclusively for protective earth (PE) and bonding conductors — no other core in an installation is permitted to use this colour combination. That matters beyond labelling: fast, unambiguous identification during installation, inspection, and fault-finding prevents an earth conductor being confused with a live or neutral core, which is one of the most common causes of a miswired protective connection. The bonding function itself depends on it — every exposed metal enclosure, gland, and extraneous conductive part (structural steel, pipework) must be traced back to the main earthing terminal to form a continuous, low-impedance path, so that under a fault an RCD or circuit breaker trips fast enough to clear the touch-voltage hazard. A conductor that is hard to identify is one that is easy to omit, damage, or disconnect during future works — the colour is what keeps that path intact and verifiable at every stage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 70mm² rating mean, and how do I size the earth conductor for my circuit?\u003c\/strong\u003e\u003cbr\u003eThe 70mm² figure is the copper conductor's cross-sectional area, which determines how much fault current it can carry momentarily without overheating before the protective device (fuse, MCB, or RCD) clears the fault. As a general principle under IEC 60364-5-54 \/ BS 7671 Table 54.7 — the basis for UAE wiring regulations — the protective\/earth conductor is sized relative to the associated line conductor: matching cross-section up to 16mm² of line conductor, then roughly half (minimum 16mm²) for larger line conductors. In this catalogue, this 70mm² size is typically specified for main incoming earth connections at transformer substations and other critical, high-fault-current installations. Always confirm the exact size against your specific circuit design, fault-current calculation, and local wiring regulations — a qualified electrical engineer or electrician should verify the value for your project.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this earth wire is sold per metre, so you can order any length to match your run (for example 37m or 158m). The listed price is per metre; enter the quantity in metres you need and we cut and supply that exact length. For large or full-reel quantities, contact us for coil pricing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat's the difference between this Earth Wire and RR Kabel's Single-Core Building Wire (line\/neutral) range?\u003c\/strong\u003e\u003cbr\u003eBoth share the same underlying construction — single-core, stranded plain annealed copper, PVC insulated, rated 450\/750V to the H07V-R design (BS EN 50525-2-31, the harmonised successor to BS 6004). The difference is purely the insulation colour and its designated function: the Building Wire range (single colours — red, blue, black, yellow) carries line and neutral conductors, while this Green\/Yellow product is manufactured and colour-coded exclusively as the protective earth\/bonding conductor. The two should never be substituted for one another on site.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this need to be installed by a licensed electrician?\u003c\/strong\u003e\u003cbr\u003eYes. Earthing and bonding conductors are safety-critical fixed wiring — correct sizing, termination, and continuity testing must be carried out by a licensed electrician in accordance with UAE wiring regulations (based on BS 7671\/IEC 60364), including verification of earth continuity and loop impedance before the installation is energised.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44128259735651,"sku":"RR-SCE-70-YG","price":50.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/GYEARTH1_s.jpg?v=1786966152"},{"product_id":"rr-xlpe-swa-armoured-cable-3c-x-4-0mm","title":"RR Kabel 3-Core 4.0mm² XLPE\/SWA Armoured Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR XLPE\/SWA Armoured Cable 3C x 4.0mm²\u003c\/h2\u003e\n\u003cp\u003eThe RR XLPE\/SWA Armoured Cable 3C x 4.0mm² is a steel wire armoured cable for underground, direct burial, and exposed installation in UAE commercial and industrial projects. Its XLPE insulation and PVC outer sheath provide excellent performance in the demanding temperature conditions of UAE outdoor and underground electrical distribution. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3-core 4.0mm² for three-phase or single-phase with earth power distribution\u003c\/li\u003e\n\u003cli\u003eSteel Wire Armour (SWA) for mechanical protection in underground and exposed runs\u003c\/li\u003e\n\u003cli\u003eXLPE insulation for elevated temperature performance\u003c\/li\u003e\n\u003cli\u003ePVC outer sheath for weather and UV resistance\u003c\/li\u003e\n\u003cli\u003eSold per metre for accurate project cable quantities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e4.0mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmour\u003c\/td\u003e\n\u003ctd\u003eSteel Wire Armour (SWA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Sheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e0.6\/1kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 5467\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUnderground direct burial power distribution\u003c\/li\u003e\n\u003cli\u003eOutdoor exposed cable runs in UAE industrial sites\u003c\/li\u003e\n\u003cli\u003eThree-phase power supply to buildings and plant\u003c\/li\u003e\n\u003cli\u003eSub-main distribution in commercial and residential projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 4.0mm² cross-section rating mean, and how do I pick the right size?\u003c\/strong\u003e\u003cbr\u003eThe 4.0mm² figure is the nominal cross-sectional area of each copper conductor, which determines the cable's current-carrying capacity and voltage drop over a given run length. Larger cross-sections carry higher loads over longer distances with less voltage drop. This 3-core 4.0mm² cable is sized for three-phase (without neutral) or single-phase-with-earth power distribution — always have your electrical consultant or a licensed electrician confirm the exact size against the circuit's load, run length, and installation method (buried, in duct, on tray, or in free air) before ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this cable is sold per metre, so you can order the exact length required for your run (plus a reasonable allowance for routing, terminations, and jointing). The listed price is per metre; simply set the quantity to the number of metres you need and the total is calculated automatically at checkout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow is XLPE\/SWA armoured cable different from RR Kabel's PVC Flexible Cable range?\u003c\/strong\u003e\u003cbr\u003ePVC Flexible Cable is an unarmoured, stranded-conductor cable meant for indoor wiring to fixed appliances and equipment where the cable is protected from mechanical damage. This XLPE\/SWA cable adds a galvanised steel wire armour layer and XLPE insulation rated for higher temperatures, making it suitable for underground, direct-burial, and exposed outdoor runs where mechanical protection and higher thermal performance are required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the SWA (Steel Wire Armour) layer protect against, and why is it needed for underground or direct-burial installation?\u003c\/strong\u003e\u003cbr\u003eThe galvanised steel wire armour sits between the inner PVC bedding and the outer PVC sheath, forming a mechanically robust layer around the insulated cores. It protects the cable against crushing, impact, and abrasion from backfill material, ground movement, and accidental damage from digging tools during and after installation — risks that an unarmoured cable cannot withstand underground. The armour also provides a continuous earth continuity conductor and some resistance to rodent damage. This is why SWA construction is specified for direct-in-ground burial, duct runs exposed to soil movement, and other installations where the cable cannot be visually inspected or easily protected by conduit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this cable need to be installed by a licensed electrician?\u003c\/strong\u003e\u003cbr\u003eYes. XLPE\/SWA armoured power cable is fixed electrical infrastructure and must be installed, terminated (including correct armour glanding and earthing), and connected by a licensed electrician in accordance with UAE wiring regulations and the relevant cable standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44128259768419,"sku":"RR-ARM-3C-4.0-NAT","price":20.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/3-core-35mm-swa-cable-logo_6c971503-6701-4c21-9343-6fa999febf51.jpg?v=1786966153"},{"product_id":"rr-xlpe-swa-armoured-cable-3c-x-6-0mm","title":"RR Kabel 3-Core 6.0mm² XLPE\/SWA Armoured Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR XLPE\/SWA Armoured Cable 3C x 6.0mm²\u003c\/h2\u003e\n\u003cp\u003eThe RR XLPE\/SWA Armoured Cable 3C x 6.0mm² is a mechanically protected steel wire armoured cable for underground, direct burial, and outdoor power distribution in UAE commercial and industrial installations. Its 6.0mm² three-core construction suits sub-main feeds and three-phase or single-phase distribution where mechanical damage protection is required. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3-core 6.0mm² for sub-main and three-phase distribution runs\u003c\/li\u003e\n\u003cli\u003eSteel Wire Armour (SWA) for mechanical damage protection\u003c\/li\u003e\n\u003cli\u003eXLPE insulation for superior temperature and electrical performance\u003c\/li\u003e\n\u003cli\u003ePVC outer sheath for UV and weather resistance in UAE conditions\u003c\/li\u003e\n\u003cli\u003eSold per metre for project-accurate quantities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e6.0mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmour\u003c\/td\u003e\n\u003ctd\u003eSteel Wire Armour (SWA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Sheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e0.6\/1kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 5467\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUnderground sub-main distribution runs\u003c\/li\u003e\n\u003cli\u003eOutdoor and exposed three-phase power cables\u003c\/li\u003e\n\u003cli\u003eBuilding-to-building power distribution in UAE projects\u003c\/li\u003e\n\u003cli\u003eIndustrial site sub-main and distribution feeders\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6.0mm² cross-section rating mean, and how do I pick the right size?\u003c\/strong\u003e\u003cbr\u003eThe 6.0mm² figure is the nominal cross-sectional area of each copper conductor, which determines the cable's current-carrying capacity and voltage drop over a given run length. Larger cross-sections carry higher loads over longer distances with less voltage drop. This 3-core 6.0mm² cable is sized for three-phase (without neutral) or single-phase-with-earth power distribution — always have your electrical consultant or a licensed electrician confirm the exact size against the circuit's load, run length, and installation method (buried, in duct, on tray, or in free air) before ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this cable is sold per metre, so you can order the exact length required for your run (plus a reasonable allowance for routing, terminations, and jointing). The listed price is per metre; simply set the quantity to the number of metres you need and the total is calculated automatically at checkout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow is XLPE\/SWA armoured cable different from RR Kabel's PVC Flexible Cable range?\u003c\/strong\u003e\u003cbr\u003ePVC Flexible Cable is an unarmoured, stranded-conductor cable meant for indoor wiring to fixed appliances and equipment where the cable is protected from mechanical damage. This XLPE\/SWA cable adds a galvanised steel wire armour layer and XLPE insulation rated for higher temperatures, making it suitable for underground, direct-burial, and exposed outdoor runs where mechanical protection and higher thermal performance are required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the SWA (Steel Wire Armour) layer protect against, and why is it needed for underground or direct-burial installation?\u003c\/strong\u003e\u003cbr\u003eThe galvanised steel wire armour sits between the inner PVC bedding and the outer PVC sheath, forming a mechanically robust layer around the insulated cores. It protects the cable against crushing, impact, and abrasion from backfill material, ground movement, and accidental damage from digging tools during and after installation — risks that an unarmoured cable cannot withstand underground. The armour also provides a continuous earth continuity conductor and some resistance to rodent damage. This is why SWA construction is specified for direct-in-ground burial, duct runs exposed to soil movement, and other installations where the cable cannot be visually inspected or easily protected by conduit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this cable need to be installed by a licensed electrician?\u003c\/strong\u003e\u003cbr\u003eYes. XLPE\/SWA armoured power cable is fixed electrical infrastructure and must be installed, terminated (including correct armour glanding and earthing), and connected by a licensed electrician in accordance with UAE wiring regulations and the relevant cable standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44128259801187,"sku":"RR-ARM-3C-6.0-NAT","price":22.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/3-core-35mm-swa-cable-logo.jpg?v=1786966154"},{"product_id":"rr-xlpe-swa-armoured-cable-4c-x-6-0mm","title":"RR Kabel 4-Core 6.0mm² XLPE\/SWA Armoured Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR XLPE\/SWA Armoured Cable 4C x 6.0mm²\u003c\/h2\u003e\n\u003cp\u003eThe RR XLPE\/SWA Armoured Cable 4C x 6.0mm² is a four-core steel wire armoured cable providing full three-phase with neutral in a mechanically protected construction for underground and outdoor distribution in UAE commercial, residential, and industrial projects. Ideal for sub-main feeds and building supply runs requiring armoured protection. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4-core 6.0mm² for complete three-phase plus neutral distribution\u003c\/li\u003e\n\u003cli\u003eSteel Wire Armour (SWA) for protection in underground and exposed runs\u003c\/li\u003e\n\u003cli\u003eXLPE insulation for high-temperature performance in UAE conditions\u003c\/li\u003e\n\u003cli\u003ePVC outer sheath for UV and moisture resistance\u003c\/li\u003e\n\u003cli\u003eSold per metre for precise project quantities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e6.0mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmour\u003c\/td\u003e\n\u003ctd\u003eSteel Wire Armour (SWA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Sheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e0.6\/1kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 5467\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUnderground three-phase sub-main distribution\u003c\/li\u003e\n\u003cli\u003eBuilding supply and incoming mains cables\u003c\/li\u003e\n\u003cli\u003eOutdoor exposed three-phase feeder runs\u003c\/li\u003e\n\u003cli\u003eCommercial and residential estate distribution networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 6.0mm² cross-section rating mean, and how do I pick the right size?\u003c\/strong\u003e\u003cbr\u003eThe 6.0mm² figure is the nominal cross-sectional area of each copper conductor, which determines the cable's current-carrying capacity and voltage drop over a given run length. Larger cross-sections carry higher loads over longer distances with less voltage drop. This 4-core 6.0mm² cable is sized for three-phase-plus-neutral power distribution — always have your electrical consultant or a licensed electrician confirm the exact size against the circuit's load, run length, and installation method (buried, in duct, on tray, or in free air) before ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this cable is sold per metre, so you can order the exact length required for your run (plus a reasonable allowance for routing, terminations, and jointing). The listed price is per metre; simply set the quantity to the number of metres you need and the total is calculated automatically at checkout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow is XLPE\/SWA armoured cable different from RR Kabel's PVC Flexible Cable range?\u003c\/strong\u003e\u003cbr\u003ePVC Flexible Cable is an unarmoured, stranded-conductor cable meant for indoor wiring to fixed appliances and equipment where the cable is protected from mechanical damage. This XLPE\/SWA cable adds a galvanised steel wire armour layer and XLPE insulation rated for higher temperatures, making it suitable for underground, direct-burial, and exposed outdoor runs where mechanical protection and higher thermal performance are required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the SWA (Steel Wire Armour) layer protect against, and why is it needed for underground or direct-burial installation?\u003c\/strong\u003e\u003cbr\u003eThe galvanised steel wire armour sits between the inner PVC bedding and the outer PVC sheath, forming a mechanically robust layer around the insulated cores. It protects the cable against crushing, impact, and abrasion from backfill material, ground movement, and accidental damage from digging tools during and after installation — risks that an unarmoured cable cannot withstand underground. The armour also provides a continuous earth continuity conductor and some resistance to rodent damage. This is why SWA construction is specified for direct-in-ground burial, duct runs exposed to soil movement, and other installations where the cable cannot be visually inspected or easily protected by conduit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this cable need to be installed by a licensed electrician?\u003c\/strong\u003e\u003cbr\u003eYes. XLPE\/SWA armoured power cable is fixed electrical infrastructure and must be installed, terminated (including correct armour glanding and earthing), and connected by a licensed electrician in accordance with UAE wiring regulations and the relevant cable standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44128259833955,"sku":"RR-ARM-4C-6.0-NAT","price":32.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_330de768-6ab0-470d-949a-57f5f33a8630.jpg?v=1786966161"},{"product_id":"rr-xlpe-swa-armoured-cable-4c-x-10mm","title":"RR Kabel 4-Core 10mm² XLPE\/SWA Armoured Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR XLPE\/SWA Armoured Cable 4C x 10mm²\u003c\/h2\u003e\n\u003cp\u003eThe RR XLPE\/SWA Armoured Cable 4C x 10mm² is a heavy-duty four-core armoured cable for underground mains distribution, building supply runs, and outdoor power installations across UAE commercial, residential, and industrial projects. Its 10mm² conductors deliver the current capacity required for main sub-station feeds and primary distribution runs. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4-core 10mm² for mains-level three-phase distribution runs\u003c\/li\u003e\n\u003cli\u003eSteel Wire Armour (SWA) for mechanical protection underground and outdoors\u003c\/li\u003e\n\u003cli\u003eXLPE insulation rated for elevated temperatures in UAE ground conditions\u003c\/li\u003e\n\u003cli\u003ePVC outer sheath for UV, weather, and chemical resistance\u003c\/li\u003e\n\u003cli\u003eSold per metre for accurate large-project cable runs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e10mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmour\u003c\/td\u003e\n\u003ctd\u003eSteel Wire Armour (SWA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Sheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e0.6\/1kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 5467\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUnderground mains distribution in UAE residential developments\u003c\/li\u003e\n\u003cli\u003eOutdoor incoming supply cables for buildings and facilities\u003c\/li\u003e\n\u003cli\u003eIndustrial site three-phase distribution networks\u003c\/li\u003e\n\u003cli\u003eCommercial estate and infrastructure power distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 10mm² cross-section rating mean, and how do I pick the right size?\u003c\/strong\u003e\u003cbr\u003eThe 10mm² figure is the nominal cross-sectional area of each copper conductor, which determines the cable's current-carrying capacity and voltage drop over a given run length. Larger cross-sections carry higher loads over longer distances with less voltage drop. This 4-core 10mm² cable is sized for three-phase-plus-neutral power distribution — always have your electrical consultant or a licensed electrician confirm the exact size against the circuit's load, run length, and installation method (buried, in duct, on tray, or in free air) before ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this cable is sold per metre, so you can order the exact length required for your run (plus a reasonable allowance for routing, terminations, and jointing). The listed price is per metre; simply set the quantity to the number of metres you need and the total is calculated automatically at checkout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow is XLPE\/SWA armoured cable different from RR Kabel's PVC Flexible Cable range?\u003c\/strong\u003e\u003cbr\u003ePVC Flexible Cable is an unarmoured, stranded-conductor cable meant for indoor wiring to fixed appliances and equipment where the cable is protected from mechanical damage. This XLPE\/SWA cable adds a galvanised steel wire armour layer and XLPE insulation rated for higher temperatures, making it suitable for underground, direct-burial, and exposed outdoor runs where mechanical protection and higher thermal performance are required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the SWA (Steel Wire Armour) layer protect against, and why is it needed for underground or direct-burial installation?\u003c\/strong\u003e\u003cbr\u003eThe galvanised steel wire armour sits between the inner PVC bedding and the outer PVC sheath, forming a mechanically robust layer around the insulated cores. It protects the cable against crushing, impact, and abrasion from backfill material, ground movement, and accidental damage from digging tools during and after installation — risks that an unarmoured cable cannot withstand underground. The armour also provides a continuous earth continuity conductor and some resistance to rodent damage. This is why SWA construction is specified for direct-in-ground burial, duct runs exposed to soil movement, and other installations where the cable cannot be visually inspected or easily protected by conduit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this cable need to be installed by a licensed electrician?\u003c\/strong\u003e\u003cbr\u003eYes. XLPE\/SWA armoured power cable is fixed electrical infrastructure and must be installed, terminated (including correct armour glanding and earthing), and connected by a licensed electrician in accordance with UAE wiring regulations and the relevant cable standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44128260227171,"sku":"RR-ARM-4C-10-NAT","price":40.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_330de768-6ab0-470d-949a-57f5f33a8630.jpg?v=1786966161"},{"product_id":"rr-xlpe-swa-armoured-cable-4c-x-25mm","title":"RR Kabel 4-Core 25mm² XLPE\/SWA Armoured Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR XLPE\/SWA Armoured Cable 4C x 25mm²\u003c\/h2\u003e\n\u003cp\u003eThe RR XLPE\/SWA Armoured Cable 4C x 25mm² is a high-capacity four-core armoured cable for main incoming supply, large sub-station feeders, and primary distribution networks in UAE large commercial, industrial, and infrastructure projects. Its 25mm² conductors handle substantial current loads in underground and outdoor installations. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4-core 25mm² for main incoming supply and primary distribution cables\u003c\/li\u003e\n\u003cli\u003eSteel Wire Armour (SWA) for heavy-duty mechanical protection\u003c\/li\u003e\n\u003cli\u003eXLPE insulation for high-temperature performance in UAE soil and outdoor conditions\u003c\/li\u003e\n\u003cli\u003ePVC outer sheath for long-term UV, weather, and ground resistance\u003c\/li\u003e\n\u003cli\u003eSold per metre for large-scale project ordering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e25mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmour\u003c\/td\u003e\n\u003ctd\u003eSteel Wire Armour (SWA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Sheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e0.6\/1kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 5467\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain incoming supply cables for large commercial buildings\u003c\/li\u003e\n\u003cli\u003eUnderground primary distribution networks in UAE developments\u003c\/li\u003e\n\u003cli\u003eIndustrial facility main power distribution runs\u003c\/li\u003e\n\u003cli\u003eSub-station to MDB primary feeder cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 25mm² cross-section rating mean, and how do I pick the right size?\u003c\/strong\u003e\u003cbr\u003eThe 25mm² figure is the nominal cross-sectional area of each copper conductor, which determines the cable's current-carrying capacity and voltage drop over a given run length. Larger cross-sections carry higher loads over longer distances with less voltage drop. This 4-core 25mm² cable is sized for three-phase-plus-neutral power distribution — always have your electrical consultant or a licensed electrician confirm the exact size against the circuit's load, run length, and installation method (buried, in duct, on tray, or in free air) before ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this cable is sold per metre, so you can order the exact length required for your run (plus a reasonable allowance for routing, terminations, and jointing). The listed price is per metre; simply set the quantity to the number of metres you need and the total is calculated automatically at checkout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow is XLPE\/SWA armoured cable different from RR Kabel's PVC Flexible Cable range?\u003c\/strong\u003e\u003cbr\u003ePVC Flexible Cable is an unarmoured, stranded-conductor cable meant for indoor wiring to fixed appliances and equipment where the cable is protected from mechanical damage. This XLPE\/SWA cable adds a galvanised steel wire armour layer and XLPE insulation rated for higher temperatures, making it suitable for underground, direct-burial, and exposed outdoor runs where mechanical protection and higher thermal performance are required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the SWA (Steel Wire Armour) layer protect against, and why is it needed for underground or direct-burial installation?\u003c\/strong\u003e\u003cbr\u003eThe galvanised steel wire armour sits between the inner PVC bedding and the outer PVC sheath, forming a mechanically robust layer around the insulated cores. It protects the cable against crushing, impact, and abrasion from backfill material, ground movement, and accidental damage from digging tools during and after installation — risks that an unarmoured cable cannot withstand underground. The armour also provides a continuous earth continuity conductor and some resistance to rodent damage. This is why SWA construction is specified for direct-in-ground burial, duct runs exposed to soil movement, and other installations where the cable cannot be visually inspected or easily protected by conduit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this cable need to be installed by a licensed electrician?\u003c\/strong\u003e\u003cbr\u003eYes. XLPE\/SWA armoured power cable is fixed electrical infrastructure and must be installed, terminated (including correct armour glanding and earthing), and connected by a licensed electrician in accordance with UAE wiring regulations and the relevant cable standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44128260391011,"sku":"RR-ARM-4C-25-NAT","price":78.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_330de768-6ab0-470d-949a-57f5f33a8630.jpg?v=1786966161"},{"product_id":"rr-xlpe-swa-armoured-cable-4c-x-35mm","title":"RR Kabel 4-Core 35mm² XLPE\/SWA Armoured Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR XLPE\/SWA Armoured Cable 4C x 35mm²\u003c\/h2\u003e\n\u003cp\u003eThe RR XLPE\/SWA Armoured Cable 4C x 35mm² is a large-section four-core armoured cable for primary distribution feeders, main incoming supply runs, and heavy industrial cable networks in UAE large-scale projects. Its 35mm² conductors provide the high current capacity required for major distribution runs in commercial, industrial, and infrastructure electrical systems. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4-core 35mm² for major distribution feeders and main incoming supply\u003c\/li\u003e\n\u003cli\u003eSteel Wire Armour (SWA) for heavy-duty mechanical damage protection\u003c\/li\u003e\n\u003cli\u003eXLPE insulation for extended thermal performance in UAE underground conditions\u003c\/li\u003e\n\u003cli\u003ePVC outer sheath for long-term durability in harsh outdoor environments\u003c\/li\u003e\n\u003cli\u003eSold per metre for large infrastructure project ordering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e35mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmour\u003c\/td\u003e\n\u003ctd\u003eSteel Wire Armour (SWA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Sheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e0.6\/1kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 5467\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary distribution feeders in UAE large commercial projects\u003c\/li\u003e\n\u003cli\u003eUnderground main supply cables for industrial facilities\u003c\/li\u003e\n\u003cli\u003eInfrastructure and utility distribution network cables\u003c\/li\u003e\n\u003cli\u003eLarge sub-station to switchgear primary feeder runs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 35mm² cross-section rating mean, and how do I pick the right size?\u003c\/strong\u003e\u003cbr\u003eThe 35mm² figure is the nominal cross-sectional area of each copper conductor, which determines the cable's current-carrying capacity and voltage drop over a given run length. Larger cross-sections carry higher loads over longer distances with less voltage drop. This 4-core 35mm² cable is sized for three-phase-plus-neutral power distribution — always have your electrical consultant or a licensed electrician confirm the exact size against the circuit's load, run length, and installation method (buried, in duct, on tray, or in free air) before ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this cable is sold per metre, so you can order the exact length required for your run (plus a reasonable allowance for routing, terminations, and jointing). The listed price is per metre; simply set the quantity to the number of metres you need and the total is calculated automatically at checkout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow is XLPE\/SWA armoured cable different from RR Kabel's PVC Flexible Cable range?\u003c\/strong\u003e\u003cbr\u003ePVC Flexible Cable is an unarmoured, stranded-conductor cable meant for indoor wiring to fixed appliances and equipment where the cable is protected from mechanical damage. This XLPE\/SWA cable adds a galvanised steel wire armour layer and XLPE insulation rated for higher temperatures, making it suitable for underground, direct-burial, and exposed outdoor runs where mechanical protection and higher thermal performance are required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the SWA (Steel Wire Armour) layer protect against, and why is it needed for underground or direct-burial installation?\u003c\/strong\u003e\u003cbr\u003eThe galvanised steel wire armour sits between the inner PVC bedding and the outer PVC sheath, forming a mechanically robust layer around the insulated cores. It protects the cable against crushing, impact, and abrasion from backfill material, ground movement, and accidental damage from digging tools during and after installation — risks that an unarmoured cable cannot withstand underground. The armour also provides a continuous earth continuity conductor and some resistance to rodent damage. This is why SWA construction is specified for direct-in-ground burial, duct runs exposed to soil movement, and other installations where the cable cannot be visually inspected or easily protected by conduit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this cable need to be installed by a licensed electrician?\u003c\/strong\u003e\u003cbr\u003eYes. XLPE\/SWA armoured power cable is fixed electrical infrastructure and must be installed, terminated (including correct armour glanding and earthing), and connected by a licensed electrician in accordance with UAE wiring regulations and the relevant cable standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44128260587619,"sku":"RR-ARM-4C-35-NAT","price":95.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_330de768-6ab0-470d-949a-57f5f33a8630.jpg?v=1786966161"},{"product_id":"rr-xlpe-swa-armoured-cable-4c-x-70mm","title":"RR Kabel 4-Core 70mm² XLPE\/SWA Armoured Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR XLPE\/SWA Armoured Cable 4C x 70mm²\u003c\/h2\u003e\n\u003cp\u003eThe RR XLPE\/SWA Armoured Cable 4C x 70mm² is a very large-section four-core armoured cable for main incoming supply, primary distribution networks, and high-capacity underground power runs in UAE large commercial and industrial infrastructure projects. Its 70mm² conductors are designed for the highest current loads in distribution network installations. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4-core 70mm² for high-capacity primary distribution and incoming supply\u003c\/li\u003e\n\u003cli\u003eSteel Wire Armour (SWA) for heavy-duty mechanical protection in hostile environments\u003c\/li\u003e\n\u003cli\u003eXLPE insulation for maximum thermal performance in UAE conditions\u003c\/li\u003e\n\u003cli\u003ePVC outer sheath for long-term environmental resistance\u003c\/li\u003e\n\u003cli\u003eSold per metre for large infrastructure project ordering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e70mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmour\u003c\/td\u003e\n\u003ctd\u003eSteel Wire Armour (SWA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Sheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e0.6\/1kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 5467\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUnderground main incoming supply runs for large industrial facilities\u003c\/li\u003e\n\u003cli\u003ePrimary distribution networks in UAE major infrastructure projects\u003c\/li\u003e\n\u003cli\u003eSub-station feeder cables for commercial developments\u003c\/li\u003e\n\u003cli\u003eHigh-capacity inter-building distribution cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 70mm² cross-section rating mean, and how do I pick the right size?\u003c\/strong\u003e\u003cbr\u003eThe 70mm² figure is the nominal cross-sectional area of each copper conductor, which determines the cable's current-carrying capacity and voltage drop over a given run length. Larger cross-sections carry higher loads over longer distances with less voltage drop. This 4-core 70mm² cable is sized for three-phase-plus-neutral power distribution — always have your electrical consultant or a licensed electrician confirm the exact size against the circuit's load, run length, and installation method (buried, in duct, on tray, or in free air) before ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this cable is sold per metre, so you can order the exact length required for your run (plus a reasonable allowance for routing, terminations, and jointing). The listed price is per metre; simply set the quantity to the number of metres you need and the total is calculated automatically at checkout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow is XLPE\/SWA armoured cable different from RR Kabel's PVC Flexible Cable range?\u003c\/strong\u003e\u003cbr\u003ePVC Flexible Cable is an unarmoured, stranded-conductor cable meant for indoor wiring to fixed appliances and equipment where the cable is protected from mechanical damage. This XLPE\/SWA cable adds a galvanised steel wire armour layer and XLPE insulation rated for higher temperatures, making it suitable for underground, direct-burial, and exposed outdoor runs where mechanical protection and higher thermal performance are required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the SWA (Steel Wire Armour) layer protect against, and why is it needed for underground or direct-burial installation?\u003c\/strong\u003e\u003cbr\u003eThe galvanised steel wire armour sits between the inner PVC bedding and the outer PVC sheath, forming a mechanically robust layer around the insulated cores. It protects the cable against crushing, impact, and abrasion from backfill material, ground movement, and accidental damage from digging tools during and after installation — risks that an unarmoured cable cannot withstand underground. The armour also provides a continuous earth continuity conductor and some resistance to rodent damage. This is why SWA construction is specified for direct-in-ground burial, duct runs exposed to soil movement, and other installations where the cable cannot be visually inspected or easily protected by conduit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this cable need to be installed by a licensed electrician?\u003c\/strong\u003e\u003cbr\u003eYes. XLPE\/SWA armoured power cable is fixed electrical infrastructure and must be installed, terminated (including correct armour glanding and earthing), and connected by a licensed electrician in accordance with UAE wiring regulations and the relevant cable standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44128260653155,"sku":"RR-ARM-4C-70-NAT","price":155.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_330de768-6ab0-470d-949a-57f5f33a8630.jpg?v=1786966161"},{"product_id":"rr-xlpe-swa-armoured-cable-4c-x-95mm","title":"RR Kabel 4-Core 95mm² XLPE\/SWA Armoured Cable","description":"\u003cdiv\u003e\n\u003ch2\u003eRR XLPE\/SWA Armoured Cable 4C x 95mm²\u003c\/h2\u003e\n\u003cp\u003eThe RR XLPE\/SWA Armoured Cable 4C x 95mm² is a premium very large-section four-core armoured cable for the most demanding main incoming supply and primary distribution applications in UAE large-scale industrial, commercial, and infrastructure projects. Its 95mm² conductors provide exceptional current-carrying capacity for high-power distribution networks. Sold per metre.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4-core 95mm² for the highest-capacity incoming supply and primary distribution\u003c\/li\u003e\n\u003cli\u003eSteel Wire Armour (SWA) for maximum mechanical protection underground and outdoors\u003c\/li\u003e\n\u003cli\u003eXLPE insulation for superior thermal and electrical performance in UAE conditions\u003c\/li\u003e\n\u003cli\u003ePVC outer sheath for long-term resistance to UV, moisture, and ground chemicals\u003c\/li\u003e\n\u003cli\u003eSold per metre for major infrastructure project ordering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRR Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCores\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e95mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eXLPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmour\u003c\/td\u003e\n\u003ctd\u003eSteel Wire Armour (SWA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Sheath\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e0.6\/1kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eBS 5467\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003ePer Metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain incoming supply for large industrial complexes and data centres\u003c\/li\u003e\n\u003cli\u003ePrimary distribution networks for UAE major infrastructure projects\u003c\/li\u003e\n\u003cli\u003eHigh-capacity sub-station to switchgear feeder cables\u003c\/li\u003e\n\u003cli\u003eLarge-scale commercial and mixed-use development power supply runs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the 95mm² cross-section rating mean, and how do I pick the right size?\u003c\/strong\u003e\u003cbr\u003eThe 95mm² figure is the nominal cross-sectional area of each copper conductor, which determines the cable's current-carrying capacity and voltage drop over a given run length. Larger cross-sections carry higher loads over longer distances with less voltage drop. This 4-core 95mm² cable is sized for three-phase-plus-neutral power distribution — always have your electrical consultant or a licensed electrician confirm the exact size against the circuit's load, run length, and installation method (buried, in duct, on tray, or in free air) before ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I order an exact length, and how is the price calculated?\u003c\/strong\u003e\u003cbr\u003eYes — this cable is sold per metre, so you can order the exact length required for your run (plus a reasonable allowance for routing, terminations, and jointing). The listed price is per metre; simply set the quantity to the number of metres you need and the total is calculated automatically at checkout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow is XLPE\/SWA armoured cable different from RR Kabel's PVC Flexible Cable range?\u003c\/strong\u003e\u003cbr\u003ePVC Flexible Cable is an unarmoured, stranded-conductor cable meant for indoor wiring to fixed appliances and equipment where the cable is protected from mechanical damage. This XLPE\/SWA cable adds a galvanised steel wire armour layer and XLPE insulation rated for higher temperatures, making it suitable for underground, direct-burial, and exposed outdoor runs where mechanical protection and higher thermal performance are required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the SWA (Steel Wire Armour) layer protect against, and why is it needed for underground or direct-burial installation?\u003c\/strong\u003e\u003cbr\u003eThe galvanised steel wire armour sits between the inner PVC bedding and the outer PVC sheath, forming a mechanically robust layer around the insulated cores. It protects the cable against crushing, impact, and abrasion from backfill material, ground movement, and accidental damage from digging tools during and after installation — risks that an unarmoured cable cannot withstand underground. The armour also provides a continuous earth continuity conductor and some resistance to rodent damage. This is why SWA construction is specified for direct-in-ground burial, duct runs exposed to soil movement, and other installations where the cable cannot be visually inspected or easily protected by conduit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this cable need to be installed by a licensed electrician?\u003c\/strong\u003e\u003cbr\u003eYes. XLPE\/SWA armoured power cable is fixed electrical infrastructure and must be installed, terminated (including correct armour glanding and earthing), and connected by a licensed electrician in accordance with UAE wiring regulations and the relevant cable standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"RRKabel","offers":[{"title":"Per Metre","offer_id":44128261177443,"sku":"RR-ARM-4C-95-NAT","price":295.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/rn-image_picker_lib_temp_330de768-6ab0-470d-949a-57f5f33a8630.jpg?v=1786966161"}],"url":"https:\/\/www.deluxeuae.com\/collections\/cable-wires.oembed","provider":"Deluxe Electricals","version":"1.0","type":"link"}